Showing 5731–5736 of 5736 results
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ZYET-5100 |
| Price Range | USD 1,400 – 7,000 |
| Instrument Type | Portable Flue Gas Analyzer |
| Indication Error | ≤ ±5% FS |
| Repeatability | ≤ 2% RSD |
| Response Time | ≤ 90 s (T₉₀) |
| Stability | ≤ ±5% FS/8 h |
| Measurement Principles | Electrochemical (O₂, NO, NO₂, SO₂, CO) |
| O₂ Range | 0–20.9 vol% |
| NO | 0–1000 ppm |
| NO₂ | 0–100 ppm |
| SO₂ | 0–2000 ppm |
| CO | 0–2000 ppm |
| Ambient Temp | 0–200 °C |
| Flue Gas Temp | 0–400 °C |
| Static Pressure | −30 to +30 kPa |
| Differential Pressure | 0–2.5 kPa |
| Resolution | O₂: 0.1 vol% |
| Gases | 1 ppm |
| Temp | 1 °C |
| Pressure | 0.01 kPa (Static), 1 Pa (Differential) |
| Accuracy | O₂: ±0.5% FS |
| Gases | ±5% FS |
| Temp | ±1% (Ambient), ±2% (Flue) |
| Pressure | ±3% FS |
| Data Storage | 500 measurement sets |
| Power | Internal 6 V × 2 rechargeable battery |
| Dimensions (W×D×H) | 417 × 234 × 318 mm |
| Weight | ~10 kg (configuration-dependent) |
| Operating Environment | −0°C to +40°C |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ZYET-5101 |
| Price Range | USD 1,400 – 7,000 |
| Instrument Type | Portable Flue Gas & Particulate Analyzer |
| Indication Error | ≤5% FS |
| Repeatability | ≤2% RSD |
| Response Time | ≤90 s |
| Stability | ≤5% drift over 2 hours |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | ZYKX |
| Price Range | USD 14,000 – 28,000 |
| CO₂ Range | 0–3000 ppm |
| Accuracy | ±(1% FS + 1.5% RDG) |
| Channel Capacity | 1–16 configurable |
| Data Logging Interval | 1–60 min adjustable |
| Operating Temp | −20 to +60 °C |
| Operating Humidity | 0–100% RH (non-condensing) |
| Power Supply | 12 VDC |
| Chamber Dimensions | Ø160 mm × 170 mm H |
| Cable & Tubing Length | Standard 5 m (customizable) |
| Display | LCD |
| Memory | 2 MB standard (expandable) |
| Communication | USB / RS-232 / GPRS (SIM card & data plan not included) |
| Chamber Actuation | Motor-driven slow-close mechanism with pressure compensation |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S7000 |
| Price | USD 3,850 (FOB) |
| Origin | Shenzhen, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | μChem NIA 2000 |
| Price Range | USD 28,000 – 35,000 |
| Measured Parameters | Total Nitrogen (TN), Total Phosphorus (TP) |
| Instrument Type | Online Analyzer |
| Measurement Principle | Spectrophotometry (UV-Vis) |
| Detection Limit | 0.001 mg/L |
| Accuracy | ±3% of reading |
| Resolution | 0.001 mg/L |
| Power Consumption | 8 W (operational), 1.2 W (standby) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | YC-1800 |
| Price | USD 12,000 (FOB Shanghai) |
| Sample Type | Aqueous solutions only |
| Max Feed Rate | 1000–1500 mL/h |
| Inlet Air Temperature Range | 105–200 °C |
| Particle Size Distribution | 1–25 µm |