Generic
Filter
Showing 721–750 of 1032 results
| Origin | China (manufactured in Shaoxing) |
|---|---|
| Supplier type | Authorized distributor |
| Import status | Domestic production with international-standard engineering |
| Price | USD 14,000–18,000 (FOB Shaoxing, subject to configuration) |
| Origin | Russia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SHATOX SX-300 |
| Pricing | Available Upon Request |
| Key | Origin: Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | LD-3C |
| Measurement Principle | Light Scattering (Laser Nephelometry) |
| Safety Rating | Non-explosion-proof |
| Range (Low) | 0.01–100 mg/m³ |
| Range (High) | 0.001–10 mg/m³ |
| Sensitivity (L) | 1 CPM = 0.01 mg/m³ |
| Sensitivity (H) | 1 CPM = 0.001 mg/m³ |
| Sampling Time Options | 0.1, 1, 2, 5, 10 min + manual mode |
| Accuracy | ±10% |
| Dimensions | 192 × 69 × 140 mm |
| Weight | 1.4 kg |
| Compliance | WS/T 206–2001, LD 98–1996, TB/T 2323–92 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Distributor |
| Product Origin | Domestic (China) |
| Model | FastnessGrade |
| Price Range | USD 28,000 – 42,500 |
| Instrument Type | Benchtop Spectrophotometer |
| Optical Geometry | 0/45° Integrating Sphere |
| Illuminant | LED Array |
| Spectral Range | 350–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Origin | Japan |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | BL Series |
| Quotation | Upon Request |
| Instrument Type | Precision Balance |
| Capacity | 3200 g |
| Minimum Display | 10 mg |
| Standard Deviation | 0.01 g |
| Linearity | ±0.02 g |
| Operating Temperature | 5–40 °C |
| Interface | RS-232C (with IFB-102A interface board), EP-50/EP-80 printer support |
| Sensitivity Drift (10–30 °C) | ±3 ppm/°C (PSC OFF) |
| Units | g, kg, %, pcs, ct, mom, oz, ozt, liang (HK/SG/TW/MY), dwt, gn |
| Pan Dimensions | 160 × 124 mm |
| Body Dimensions | 170 × 240 × 75 mm (W×D×H) |
| Weight | 2.2 kg |
| Power Supply | AC 220 V / DC 12 V, 1 A |
| Standard Accessories | Dust Cover |
| Sensor Type | Electromagnetic Force Compensation |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GC-2014 |
| Price Range | USD 21,000 – 28,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient +10°C to 420°C (–50°C to 420°C with liquid CO₂ cooling) |
| Maximum Ramp Rate | 250°C/min |
| Cooling Rate | 300°C → 50°C in <6 min |
| Carrier Gas Flow Range & Control | 0–1250 mL/min |
| Carrier Gas Pressure Range & Control | 0–1035 kPa |
| Injector Max Operating Temperature | 420°C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Injector Total Flow Setting Range | 0–1250 mL/min |
| Oven Program Segments | Up to 20 (including cooling ramps) |
| Injector Simultaneous Installation | Up to 3 units |
| Detector Simultaneous Installation | Up to 4 units |
| Detector Compatibility | FID, TCD, ECD, FPD, FTD (capillary & packed column variants) |
| Display | 240 × 320-pixel graphical LCD (30 chars × 60 lines) |
| Dimensions (GC Main Unit) | 400 × 690 × 607 mm (W × H × D) |
| Weight | 48 kg (GC-2014AF configuration) |
| Power Supply | AC 200 V, 1800 VA, 50/60 Hz |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MXF-2400 |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SALD-2300 |
| Price Range | USD 27,000–41,000 (approx.) |
| Dispersion Method | Dry & Wet |
| Measurement Range | 0.017–2500 µm |
| Repeatability | <1% RSD |
| Measurement Time | 10–15 s per analysis |
| Key | Max Load Capacity: 50–800 kg |
|---|---|
| Peak Acceleration Range | 30–1000 m/s² |
| Pulse Duration | 20–230 ms |
| Repetition Rate | 10–60 impacts/min |
| Table Surface Dimensions | 500×700 to 1000×1000 mm |
| Drop Height Range | 0–800 mm |
| Continuous Operation Time | 8 h |
| Compliance | GB/T 2423.5–1995, GB/T 2423.6–1995, IEC 60068-2-27, IEC 60068-2-29, JJG 497–2000 |
| Key | Table Surface Dimension: 200 × 200 mm |
|---|---|
| Max Payload | 10 kg |
| Pulse Duration Range | 0.6–20 ms (programmable, auto-controlled) |
| Peak Acceleration Range | 150–20,000 m/s² |
| Pulse Waveform | Half-sine |
| Shock Direction | Vertical |
| Secondary Impact Prevention | Hydraulic-friction braking system |
| Height Control | Digital preset + hydraulic lifting |
| Control & Measurement System | Integrated |
| Table Mass | 2800 kg |
| Overall Dimensions | 750 × 2600 × 1000 mm |
| Power Supply | AC 380 V ±10%, 50 Hz, 3 kVA |
| Repetition Rate | 0–100 shocks/min (±1% accuracy) |
| Sampling Rate | 200 kHz |
| Signal Conditioning | Analog filtering + 160 dB/oct digital anti-aliasing filter |
| Compliance Standards | IEC 60068-2-27, GB/T 2423.5, GJB 150.18A, GJB 360B, JJG 497 |
| Software Platform | Windows XP-based with DAO engine, automated Word report generation, real-time display of lift height, acceleration amplitude, pulse width, and Δv |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HV-RW |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Flow Rate Options | 100 / 700 L/min (quartz fiber filter + dual PU foam) or 556 / 1000 L/min (glass fiber filter) |
| Adjustable Flow Range | 100–1200 L/min |
| Flow Detection Method | Differential Pressure Sensing |
| Flow Accuracy | ±5% of setpoint |
| Pump Type | Brushless Centrifugal Blower |
| Display | Touchscreen LCD |
| Power Supply | 100 V AC (90–132 V), 220 V AC (180–264 V), 50/60 Hz |
| Operating Environment | 0–40 °C, 10–90% RH (non-condensing) |
| Filter Format | 8″ × 10″ (203 mm × 254 mm) rectangular |
| PU Foam Cartridge | Φ90 mm × 50 mm |
| Housing Material | Foldable aluminum |
| Dimensions (operational) | 575 W × 575 D × 1420 H mm |
| (folded) | 575 W × 575 D × 960 H mm |
| Sampling Inlet Height | 1210 mm above base |
| Net Weight | ~31 kg |
| Standard Kit Includes | 1 filter cassette holder, 1 straight sampling tube (for particulate), 1 shuttle tube (for dioxins), 10 quartz filters, 10 PU foam cartridges |
| Note | Filters and foam cartridges are consumables — sold separately |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SIG Series |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SN-01 |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SIS-5100 |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | UAV-Mounted Integrated Sensor Payload |
| Price Range | USD 140,000 – 210,000 |
| Product Category | Atmospheric Heavy Metal & Particulate Matter Online Analyzer |
| Measurement Principle | Laser Scattering (PM), Electrochemical (SO₂, NO₂, CO, O₃), Photoionization (VOC), Optical Absorption (optional heavy metal speciation via integrated micro-XRF or LIBS module*) |
| Measurement Range | TSP, PM₁₀ (0–1999 µg/m³), PM₂.₅ (0–999 µg/m³), O₃/SO₂/NO₂ (0–1 ppm), CO (0–200 ppm), VOC (0–50 ppm) |
| Detection Limit | 1–10 ppb (gas species) |
| Filter Replacement Interval | 30 days (under typical urban ambient conditions) |
| Operating Temperature | −30 °C to +60 °C |
| Operating Humidity | 15–95% RH (non-condensing) |
| Ambient Pressure Range | 80–106 kPa |
| Power Supply | 12–24 V DC |
| Weight | 950 g (7-parameter standard configuration) |
| Dimensions | 220 × 145 × 60 mm |
| Battery Endurance | ≥10 h continuous operation (with onboard LiPo power management) |
| Data Transmission | Dual-mode GPRS + 2.4 GHz RF telemetry (AES-128 encrypted) |
| Compliance | ISO 9001-certified manufacturing |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SKZ-1000B |
| Price Range | USD 140–1,400 (FOB) |
| Maximum Test Load | 10 kN |
| Load Application Rate | 5–700 N/s (digitally adjustable) |
| Platen Spacing | 100 mm |
| Platen Dimensions | 1000 × 1000 mm |
| Specimen Size Range | 50 × 60 mm to 1000 × 1000 mm |
| Load Measurement Accuracy | ±0.5% of full scale |
| Power Supply | 220 V AC, 0.8 kW |
| Loading Mode | Constant-rate motor-driven displacement control with real-time digital speed display |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SL-2 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | SL10 |
| Pricing | Upon Request |
| Sealing Temperature Range | Ambient to 400 °C |
| Temperature Resolution | ±0.1 °C |
| Temperature Accuracy | ±0.15 °C |
| Temperature Control Stability | ±0.2 °C |
| Sealing Pressure Range | 5–700 psi (34.5–4830 kPa) |
| Pressure Resolution | 1 psi (7 kPa) |
| Sealing Time Range | 100 ms to 99 s |
| Time Resolution | 10 ms |
| Time Accuracy | ±1 ms |
| Time Repeatability | ±2 ms |
| Dual Load Cells (Left/Right) | Combined Capacity 362 kg (1000 lbf), Accuracy ≤0.09 kg (0.2 lbf), Repeatability ≤0.09 kg (0.2 lbf), Calibrated per ASTM E4 |
| Peel Load Cell | 11.34 kg (25 lbf) capacity, 0.1% FS accuracy, ASTM E4 calibrated |
| Seal Jaw Length Options | 50.8 mm (2 in) for hot tack or 127 mm (5 in) with auto-feed turntable |
| Jaw Width Options | 6.35–25.4 mm (0.25–1.00 in) |
| Jaw Surface Configurations | Flat, Grooved, Custom, or Standard Geometric Profiles |
| Power Supply | 230 V / 50 Hz |
| Compressed Air Requirement | 80–120 psi (recommended 90 psi), integrated pressure switch |
| Dimensions (W×D×H) | 584.2 × 508 × 794 mm |
| Weight | 79.3 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SolarSIM-D2 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 50-0.22 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Lanbo |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sonoscan D9650 C-SAM |
| Instrument Type | Digital |
| Compliance | ASTM E1783, ISO/IEC 17025-compatible workflow support, GLP/GMP-ready audit trail (via Sonolytics software) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-425 |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Measurement Ranges | 0–1%, 0–5%, 0–10%, 0–25%, 0–100% O₂ (selectable) |
| Accuracy | < ±1% FS |
| Sensor Type | Miniaturized Electrochemical Fuel Cell |
| Operating Temperature | –10 to +50 °C |
| Temperature Compensation | Built-in |
| Enclosure Dimensions | 241 × 165 × 96 mm |
| Power Supply | 12–24 VDC, 25 mA |
| Output Signals | 4–20 mA, 0–10 VDC, MODBUS RS485 (ASCII, bi-directional) |
| Sample Flow Rate | 230–2500 mL/min |
| Certified | CE |
| Warranty | 12 months |
| Compatible Gases | N₂, Ar, He, H₂, hydrocarbon streams, and other inert or reducing atmospheres |
| Acid-Gas Option | Available with corrosion-resistant sensor for CO₂, H₂S, or SO₂-containing streams |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AC-6 |
| Quotation | Upon Request |
| Chamber Volume | Not Applicable |
| Heating Power | Not Applicable |
| Wash Temperature | Not Applicable |
| Cleaning Solution Type | Not Applicable |
| External Dimensions (L×W×D) | Not Specified |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EVW-60 / EVW-100 / High-Capacity External Washer |
| Capacity | 100–500 vials/min |
| Vial Size Range | 2–500 mL |
| Sealing Mechanism | Dual Opposing Conveyor Belt with Watertight Aluminum Cap Seal |
| Cleaning Method | Pressurized Spray (External Surface Only) |
| Compliance | Designed in Conformance with cGMP, FDA 21 CFR Part 11 (Audit Trail Ready), ISO 13485 Supportable |
| Footprint | Custom-Configurable (No Fixed Dimensions Provided) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RW-Series (RW-250 / RW-500 / RW-800 / RW-1150) |
| Quotation | Upon Request |
| Chamber Volume | Not Applicable (Modular Conveyor-Based Design) |
| Heating Power | Not Integrated (External Rinse/Preheat Options Available) |
| Wash Temperature | Ambient to 85 °C (Configurable via External Hot Water Supply) |
| Wash Liquid Compatibility | Aqueous Detergents, Sterile Water, WFI, Purified Water |
| External Dimensions (L×W×D) | Model-Dependent (RW-250: ~1,800 × 900 × 1,200 mm |
| RW-1150 | ~3,200 × 1,300 × 1,450 mm) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FS(C) Series Sterile Filling & Stoppering System |
| Pricing | Available Upon Request |
| Chamber Volume | Not Applicable (Inline Continuous-Flow System) |
| Heating Power | Not Applicable (No Integrated Heating Element) |
| Wash Temperature | Not Applicable (Not a Washing Device) |
| Cleaning Solution Type | Not Applicable |
| External Dimensions (L×W×D) | Custom-Configurable per Line Integration |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Sterilization Tunnel |
| Quotation | Upon Request |
| Chamber Volume | Not Applicable |
| Heating Power | Not Specified |
| Wash Temperature | Not Applicable |
| Cleaning Solution Type | Not Applicable |
| External Dimensions (L×W×D) | Not Specified |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TL-100, TL-200, HSTL-200 |
| Capacity | Up to 500 vials/min (HSTL-200, dependent on vial geometry and tray configuration) |
| Vial Compatibility | 2–500 mL serum vials & reagent bottles |
| Control System | PLC-based menu-driven HMI with auto-configurable changeover logic |
| Nesting | Fully automatic nested tray loading |
| Dimensions (L×W×D) | Custom-engineered per integration requirements |
| Compliance | Designed in accordance with cGMP, ISO 13485-aligned architecture, FDA 21 CFR Part 11–ready data handling infrastructure |