HAIDA INTERNATIONAL
Filter
Showing 91–120 of 205 results
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Environmental Chamber |
| Cooling Method | Air-Cooled |
| Temperature Range | 5–50 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Humidity Control | Not Specified (Uncontrolled / Optional Humidity Module Not Included) |
| Internal Chamber Dimensions | Customizable |
| Refrigerant | R134a (CFC-Free) |
| Interface | RS485 Port |
| Observation Port | Ø30 mm Access Port |
| Display | LED with Icon-Based UI |
| Safety | Independent Over-Temperature Cut-Off System |
| Control Algorithm | PID Temperature Regulation |
| Timer Function | Built-in Programmable Timer |
| Brand | Haida International |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | HD-E804-41B |
| Quotation | Upon Request |
| Exterior Material | Powder-Coated Cold-Rolled Steel |
| Interior Material | SUS304 Stainless Steel |
| Chamber Dimensions (W×D×H) | 300 × 300 × 276 mm |
| Temperature Range | Ambient +10°C to 250°C |
| Temperature Resolution | 0.1°C |
| Temperature Uniformity | ±1°C |
| Vacuum Level | ≤133 Pa (measured via imported mechanical vacuum gauge) |
| Power Supply | AC 220 V, 50 Hz |
| Input Power | 2100 W |
| Operating Environment | 5–40°C |
| Standard Compliance | JB/T 5520–1991, JB/T 9505–1999, JB 20033–2004 |
| Shelf Quantity | 2 pcs |
| Shelf Material | Anodized Aluminum (high-temp oxidation resistant, rapid thermal conduction) |
| Door Seal | Integrated Silicone Gasket with Adjustable Compression Mechanism |
| Control System | Microcomputer-Based PID Controller with LCD Interface, Menu-Driven Operation, Parameter Memory, Auto-Restart After Power Failure, Over-Temperature Alarm, and Calibration Offset Function |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Category | Domestic Laboratory Equipment |
| Model | HAIDA HD-E804-80A Vacuum Drying Oven |
| Quotation | Available Upon Request |
| Exterior Material | Powder-Coated Cold-Rolled Steel |
| Interior Material | SUS304 Stainless Steel |
| Temperature Range | Ambient (RT) to 250 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ±1 °C |
| Vacuum Level | ≤133 Pa |
| Power Supply | AC 220 V, 50 Hz |
| Input Power | 2100 W |
| Chamber Dimensions (W×D×H) | 300 × 300 × 276 mm |
| Shelf Capacity | 2 Adjustable Aluminum Shelves |
| Control System | LCD Microcomputer PID Controller with Menu-Driven Interface |
| Compliance Standards | JB/T 5520–1991, JB/T 9505–1999, JB 20033–2004 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HD-E808-120 |
| Spray Method | Adjustable |
| Fog Collection Rate | 1.0–2.0 mL/80 cm²/h (averaged over ≥16 h) |
| Nozzle Pressure | 1.00 ± 0.01 kgf/cm² |
| Test Chamber Temperature Range | RT to 50 °C |
| Internal Dimensions (L×W×H) | 1200 × 500 × 1000 mm |
| Nominal Volume | 600 L |
| Salt Solution Tank Capacity | 40 L |
| Power Supply | AC 220 V, Single-phase + PE, ±10% voltage tolerance, 50 ± 0.5 Hz |
| Max Current | 10 A |
| Temp. Control Accuracy | ±0.1 °C (PID digital controller) |
| Temp. Uniformity | ±1 °C |
| Temp. Fluctuation | ±0.5 °C |
| pH Range (Neutral) | 6.5–7.2 |
| pH Range (Acidic/CASS) | 3.1–3.3 |
| Compliance | GB/T 2423.17–2008, ISO 9227:2006, ASTM B117–2009, JIS H 8502, GB/T 10125–2012, GJB 150.11A–2009 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HD-E808-60A |
| Spray Method | Adjustable Continuous/Intermittent |
| Spray Rate | 1.0–2.0 mL/80 cm²/h (averaged over ≥16 h) |
| Nozzle Pressure | 1.00 ± 0.01 kgf/cm² |
| Test Chamber Temperature Range | RT to 50 °C |
| Temperature Uniformity | ±2 °C |
| Temperature Stability | ±1 °C |
| Temperature Resolution | 0.1 °C |
| Chamber Volume | 108 L |
| Internal Dimensions (L×W×H) | 60 × 45 × 40 cm |
| External Dimensions (L×W×H) | ~110 × 65 × 110 cm |
| Weight | ~60 kg |
| Max Power | 2.2 kW |
| Supply | 1Ø AC 220 V, 10 A |
| Compliance | ASTM B117, ISO 9227, GB/T 10125, JIS H8502, IEC 60068-2-11, GJB 150.11A |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HAIDA HD-E809 Combined Temperature-Humidity-Vibration Test System |
| Temperature Range | −40 °C to +150 °C |
| Humidity Range | 30–95 %RH |
| Temperature Ramp Rate | ≥3 °C/min (heating, no-load, average) / 0.7–1 °C/min (cooling, no-load, average) |
| Temperature Uniformity | ≤2.0 °C |
| Temperature Fluctuation | ≤±0.5 °C |
| Humidity Fluctuation | ≤±2 %RH |
| Humidity Accuracy | ±5 %RH (≤75 %RH), ±3 %RH (>75 %RH) |
| Vibration Force | 1000 kgf peak (sine), 1000 kgf rms (random), 2000 kgf peak (shock) |
| Frequency Range | 2–3000 Hz |
| Max Displacement | 51 mm p-p |
| Max Velocity | 2 m/s |
| Max Acceleration | 100 g (980 m/s², unloaded) |
| Payload Capacity | 200 kg |
| Shaker Coil Diameter | Ø200 mm |
| Coil Mass | 12 kg |
| Table Fixtures | 17 × M10 stainless steel threaded inserts |
| Magnetic Leakage | <10 Gauss |
| Eccentric Moment Tolerance | 100 N·m |
| Vertical Extension Table | 300 × 300 mm aluminum alloy, hard-anodized surface |
| Horizontal Oil-Film Slip Table | 300 × 300 mm aluminum alloy, hard-anodized, 100 × 100 mm grid M10 inserts |
| Internal Chamber Dimensions | 1200 × 1200 × 800 mm (W × D × H) |
| Test Port | One Ø100 mm port on left side |
| Refrigeration | Cascade dual-stage compression |
| Temperature Control Algorithm | PID + BTC (Balance Temperature Control) + DCC (Dynamic Cooling Capacity Control) + DEC (Dynamic Electrical Control) |
| Temperature Resolution | 0.01 °C |
| Humidity Resolution | 0.1 %RH |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | HAIDA HD-F701 Mattress Conformity & Hardness Comprehensive Analyzer |
| Load Capacity | 2 kN |
| Load Cell Accuracy | ≤ ±0.5% FS |
| Actuator Stroke | 500 mm |
| Servo Motor Power | 400 W (Panasonic) |
| Servo Driver | 400 W (Panasonic) |
| Lead Screw | Precision Ball Screw |
| Control System | Windows-based PC with Proprietary Closed-Loop Control Software |
| Speed Range | 0.1–250 mm/s (adjustable) |
| Displacement Measurement | Three Panasonic Laser Displacement Sensors |
| Displacement Accuracy | ±1 mm |
| Test Count Setting | 1–999,999 cycles (programmable) |
| Stop Conditions | Predefined cycle count, stroke limit, or test completion |
| Dimensions (L×W×H) | Approx. 2200 × 2800 × 2300 mm |
| Max Sample Size (L×W×H) | 2000 × 1800 × 400 mm |
| Weight | Approx. 1000 kg |
| Power Consumption | 2 kW |
| Power Supply | 1-phase AC 220 V |
| Primary Test Functions | Mattress Conformity Assessment, Mattress Hardness Profiling (Surface/Core/Base/Total), Hysteresis Loss Rate Calculation |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | HAIDA HD-F731 Chair Rotational Durability Tester |
| Quotation | Upon Request |
| Load Capacity | 2 kN |
| Force Sensor Range | 0.2–1.8 kN (±5% accuracy) |
| Standard Load Values | 1.24 kN (BIFMA 5.1-2017), 1.02 kN (QB/T 2280-2016), 1.13 kN (BIFMA 5.1-2017 alternate), 950 N (EN 1335-2:2018) |
| Test Speed | 10 ± 5 rpm (compliant with BIFMA 5.1 & QB/T 2280: 5–15 rpm) |
| Cycle Count | 60,000 unidirectional cycles or 120,000 total reversals (60,000 forward + 60,000 reverse) |
| Rotation Angle Adjustment | 0–360° continuous |
| Effective Test Height | 300–850 mm |
| Max Base Diameter | ≤750 mm |
| Dimensions (L×W×H) | 1400 × 1100 × 2150 mm |
| Weight | ≈320 kg |
| Power Supply | 1∮ AC 220 V |
| Power Consumption | ≈850 W |
| Data Output | USB interface |
| Compliance Standards | BIFMA 5.1-2017 (Sections 8.1–8.5), BIFMA 5.4-2020 (Section 19), QB/T 2280-2016 (Section 6.6.11), BS EN 1335-2:2018 (Annex A3) |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HAIDA HD-F731-1 Chair Rotational Durability Tester |
| Frequency Range | 1–999,999 cycles (user-definable) |
| Host Weight | ~620 kg |
| Motor | 750 W servo motor ×1 + 400 W vertical reduction motor ×1 |
| Control System | PLC-based with touchscreen HMI |
| Cycle Count Range | 1–999,999 |
| Test Speed | 5–15 cycles/min |
| Rotation Angle | 0–360° (adjustable) |
| Effective Test Height | 250–700 mm |
| Max Base Diameter | ≤750 mm |
| Dimensions (L×W×H) | 1850 × 1200 × 2400 mm |
| Power Supply | 1-phase AC 220 V |
| Total Power Consumption | ~1250 W |
| Data Output | USB interface |
| Compliance Standard | BIFMA 5.1–2017 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HAIDA HD-F732 Office Chair Caster Abrasion Tester |
| Instrument Type | Reciprocating Tribological Tester |
| Maximum Applied Load | 122 kg |
| Operating Temperature | Ambient (23 ± 5 °C) |
| Control System | PLC-based |
| Display Interface | 7-inch TFT Touchscreen |
| Adjustable Seat Height Range | 260–400 mm |
| Test Frequency | 10 ± 2 cycles/min |
| Programmable Cycle Count | 1–999,999 cycles |
| BIFMA Load Capacity | 122 kg (including chair structural components) |
| QB/T Load Capacity | 113 kg (including chair structural components) |
| Cylinder Stroke | 800 mm (standard stroke: 762 ± 50 mm) |
| Max Base Diameter | ≤ 780 mm |
| Dimensions (L×W×H) | 2950 × 1050 × 1600 mm |
| Net Weight | ~500 kg (including standard weights) |
| Power Supply | 1∮ AC 220 V, 50/60 Hz |
| Rated Power | ~100 W |
| Data Output | USB 2.0 interface |
| Compliance Standards | BIFMA X5.1-2017 (Sections 16.1–16.2.5), QB/T 2280–2016 (Section 6.6.6) |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HD-F732-1 |
| Instrument Type | Reciprocating Tribological Tester |
| Operating Temperature | Ambient |
| Load Capacity | 122 kg (standard weight set) |
| Test Speed | 10 ± 2 cycles/min |
| Cycle Count Range | 1–999,999 (user-definable) |
| Power Supply | AC 220 V, 20 A, 50 Hz |
| Power Consumption | 0.8 kW |
| Dimensions (L×W×H) | 2400 × 1600 × 1300 mm |
| Control System | PLC-based with Touchscreen Interface |
| Motion Mechanism | Motor-driven chain-and-sprocket linear reciprocation |
| Weight Loading Method | Pin-mounted砝码 tray with quick-insert safety pins |
| Compliance Standard | BIFMA X5.1-2017 Sections 16.1–16.2 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | HAIDA HD-F733 Office Chair Base Vertical Static Load Tester |
| Maximum Test Force | 1–30 kN |
| Crosshead Speed Range | 0.1–120 mm/min (adjustable) |
| Host Weight | ~300 kg |
| Force Resolution | 1/200,000 |
| Force Accuracy | ≤ ±0.5% FS |
| Effective Test Height | 650 mm (excluding fixtures) |
| Max Sample Diameter | 750 mm |
| Dimensions (L×W×H) | 1100 × 1100 × 1650 mm |
| Power Supply | 1-phase AC 220 V |
| Rated Power | ~850 W |
| Compliance Standards | BIFMA 5.1 Appendix C, QB/T 2280–2016 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HAIDA HD-F733-1 Office Chair Base Vertical Load Tester |
| Max Test Force | 1–30 kN |
| Speed Range | 0.1–120 mm/min (adjustable) |
| Host Weight | ~300 kg |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HD-F735 |
| Max Test Force | 200 kg × 3 (simultaneous) |
| Frequency Range | 10–30 cycles/min |
| Stroke Control | Motorized Vertical Adjustment |
| Force Actuation | Servo-Proportional Pneumatic Valve |
| Load Sensing | Three 200 kg Load Cells |
| Test Count Range | 1–999,999 cycles (user-defined) |
| Sample Height Range | 500–750 mm |
| Test Table Width | 800 mm |
| Power Supply | AC 220 V, 5 A, 50 Hz |
| Air Supply Requirement | ≥0.6 MPa (6 bar) |
| Rated Power | 200 W |
| Dimensions (L×W×H) | 2400 × 1000 × 1950 mm |
| Compliance Standards | GB 10357.3, QB/T 2280-2007, EN 1335:2009, EN 12520:2010 / EN 1728:2012, BIFMA 5.1-2017 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HAIDA HD-F736-2 Mattress Impact Testing Machine |
| Instrument Type | Drop-weight Impact Tester |
| Impact Energy | 25 kg Standard Impact Hammer (mass only |
| Max Specimen Dimensions | 2200 × 2000 × 400 mm (L × W × H) |
| Control System | 7-inch HMI Touchscreen + INOVANCE PLC |
| Power Supply | AC 220 V, 50 Hz, 180 W |
| Pneumatic Requirement | 6–8 bar |
| Standard Fixture | One 25 kg Calibrated Impact Hammer |
| Overall Dimensions | 3100 × 1000 × 2600 mm (L × W × H) |
| Controller Unit | 350 × 350 × 1100 mm |
| Weight | 500 kg |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HAIDA HD-F736-A Office Chair Drop Impact Tester |
| Instrument Type | Drop Weight Impact Tester |
| Impact Energies | 57 kg, 102 kg, 136 kg |
| Impact Frequency | 10–30 cycles/min |
| Adjustable Pendulum Moment Arm | 200–600 mm |
| Load Cell Range | 300 mm |
| Maximum Lift Heights | 30 mm, 36 mm, 152 mm |
| Control System | PLC-based |
| Display | Touchscreen HMI |
| Cylinder Stroke | 300 mm |
| Seat Height Adjustment Range | 200–600 mm |
| Test Count Setting Range | 1–999,999 cycles |
| Approx. Weight | 500 kg |
| Power Supply | 1∮ AC 220 V |
| Rated Power | ~200 W |
| Data Output | USB interface |
| Max. Specimen Dimensions | 1000 mm × 1000 mm (L×W) |
| Overall Dimensions | 1200 mm × 1450 mm × 2600 mm (L×W×H) |
| Compliance Standards | BIFMA X5.1-2017, QB/T 2280-2016 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | HAIDA HD-F743 Chair Structural Strength Tester |
| Load Capacity | 2 kN (durability), 5 kN (strength) |
| Force Range | 445 N–1.9 kN |
| Test Speed | 5–20 cycles/min (fatigue), 450 mm/min (static strength) |
| Load Application | Pneumatic cylinder (fatigue), servo motor (static strength) |
| Compliance Standards | QB/T 2280–2016, ANSI/BIFMA X5.1–2017 |
| Fixture Set | Seat base clamp, vertical armrest clamp, backrest pull clamp, foot block, webbing block |
| Weight | ~250 kg |
| Dimensions (L×W×H) | 2450 × 1000 × 2250 mm |
| Power Supply | 1∮ AC 220 V, ~200 W |
| Air Supply | ≥0.6 MPa |
| Control System | PLC + 7-inch HMI touchscreen |
| Data Retention | Power-loss memory with auto-resume |
| Safety Features | Mechanical stroke limiters, electrical leakage protection, emergency stop, overload cutoff |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | HD-F745 |
| Horizontal Stroke | 500 mm |
| Vertical Stroke | 300 mm |
| Impact Mass | 25 kg |
| Load Cell Capacity | 2 kN (per axis) |
| Static Force Accuracy | ±5% FS |
| Dynamic Force Accuracy | ±2% FS |
| Test Speed | 5–30 cycles/min (adjustable) |
| Max. Cycles | 0–999,999 (programmable) |
| Frame Dimensions (L×W×H) | 3200 × 2800 × 3000 mm |
| Control System | PLC + 10-inch HMI touchscreen |
| Compliance Standards | QB/T 4460–2013, ANSI/BIFMA X5.5, GB/T 3325–2008, GB/T 10357.1–2013 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HAIDA HD-F749 Drawer and Cabinet Door Fatigue Tester (Pneumatic Cylinder) |
| Actuation | Pneumatic cylinder with servo-assisted vertical positioning |
| Motor | 90 W induction motor |
| Control System | PLC-based embedded controller |
| Display | 7-inch color touchscreen HMI |
| Cylinder Stroke | 800 mm |
| Cycle Frequency | Adjustable 5–20 cycles/min |
| Vertical Travel Range | 150–1000 mm (motorized height adjustment) |
| Drawer Extension Limit | 1/3 of internal rail length or ≥100 mm residual insertion |
| Cabinet Door Opening Angle | 0–130° (adjustable via angular stop mechanism) |
| Max Test Cycles | 1–999,999 (programmable) |
| Power Supply | 1∮ AC 220 V, ~120 W |
| Weight | ~200 kg |
| Overall Dimensions (L×W×H) | ~2000 × 600 × 1600 mm |
| Data Interface | USB 2.0 for test log export |
| Compliance | GB/T 10357.5-2013 (Furniture — Strength and Durability Tests — Part 5: Drawers and Sliding Doors) |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HD-F750-1A |
| Max Test Force | 1–1300 N |
| Fatigue Frequency | 70 ± 5 cycles/min (per GB/T 18941-2003 & ISO 3385:2014) |
| Host Weight | ~80 kg |
| Max Specimen Dimensions | 380 × 380 × 150 mm (L×W×H) |
| Standard Specimen Size (GB/ISO) | 380 × 380 × 50 mm |
| ASTM Standard Specimen Size | 380 × 380 × 100 mm |
| Cycle Count Range | 1–999,999 (user-definable) |
| Indentation Speed | 100 ± 20 mm/min (per GB/T 12825-2003, ISO 2439:2008, GB/T 10807-2006) |
| Fatigue Stroke Speed | 250 ± 25 mm/min (per ASTM D3574, Test Point I3) |
| Hardness Test Stroke | 180 mm |
| Effective Force Range | 1–1300 N |
| Overall Dimensions | 600 × 500 × 1080 mm (L×W×H) |
| Power Supply | 1∮ AC 220 V |
| Rated Power | ~850 W |
| Control Interface | Touchscreen |
| Load Cell Control | Integrated PCB-based closed-loop control |
| Fixture Mounting | Magnetic coupling for rapid tool change |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HAIDA HD-F750-5 Foam Indentation Recovery Time Tester |
| Quotation | Upon Request |
| Load Capacity | 2 kN |
| Control System | PLC-based |
| Display | Touchscreen HMI |
| Test Speed Range | 20–2000 mm/min |
| Load Resolution | 1/250,000 FS |
| Load Accuracy | ≤ ±0.5% FS |
| Maximum Test Stroke | 350 mm |
| Sample Dimensions (L×W×H) | ~380 × 380 × 100 mm |
| Overall Dimensions (L×W×H) | ~600 × 500 × 1600 mm |
| Weight | ~40 kg |
| Power Supply | 1∮ AC 220 V |
| Power Consumption | ~300 W |
| Data Interface | USB |
| Output Format | Standardized test reports (CSV/PDF) |
| Compliant Standards | GB/T 26392–2011 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | HAIDA HD-F750-6 Sponge Rolling Fatigue Tester |
| Max Test Load | 1 kN |
| Frequency Range | 1–999,999 cycles (user-definable) |
| Host Weight | ~500 kg |
| Sample Dimensions | 380 mm × 380 mm × 50 mm (L×W×H) |
| Roller Diameter | 76 ± 1.3 mm × 457 mm (L) |
| Roller Weight | ≤110 N |
| Stroke Length | 300 mm |
| Test Speed | 15 ± 1.5 cycles/min |
| Vertical Travel Speed | 15 mm/min |
| Position Resolution | 1/250,000 |
| Load Accuracy | ≤±0.5% FS |
| Drive Motor | 400 W AC Servo Motor |
| Servo Driver | 400 W Digital AC Servo Drive |
| Actuation | Electric Linear Actuator |
| Control System | PLC + 7-inch Touchscreen HMI |
| Data Output | USB Interface |
| Power Supply | 1Ø AC 220 V, 5 A, 50 Hz |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | HAIDA HD-F750A Dual-Mode Foam Indentation & Tensile Testing Machine |
| Instrument Type | Electro-Hydraulic Servo Fatigue Testing Machine |
| Maximum Test Load | 500 kg Load Cell (Spoke-Type) |
| Speed Range | 0.1–500 mm/min (Computer-Controlled Adjustable) |
| Host Weight | Approx. 150 kg |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HAIDA HD-F753 Sofa Spring & Seat Cushion Fatigue Testing Machine |
| Instrument Type | Electro-Hydraulic Servo Fatigue Testing Machine |
| Maximum Test Load | 2 kN (single load cell) |
| Cycle Count Range | 1–999,999 cycles (user-definable) |
| Host Weight | ~100 kg |
| Motor | 400 W servo motor |
| Control System | PLC-based |
| Display | Touchscreen HMI |
| Test Speed | 1–80 mm/min |
| Actuator Stroke | 250 mm |
| Stroke Accuracy | ±0.25 mm |
| Power Supply | 1-phase AC 220 V |
| Total Power Consumption | ~450 W |
| Data Output | USB interface |
| Sample Dimensions (Foam) | Max. 400 × 400 × 120 mm (L×W×H) |
| Sample Dimensions (Serpentine Spring) | Width ≤70 mm |
| Overall Dimensions | 950 × 780 × 1550 mm (L×W×H) |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HD-F757-FB |
| Impact Energy | 50 lb (10 lb × 3 + 5 lb × 3 + 1 lb × 5) |
| Impact Frequency | 1–12 cycles/min (inversely proportional to stroke length) |
| Stroke Length | Up to 200 mm |
| Load Cell Range | Not specified (mechanical impact only |
| Test Width Capacity | 290–650 mm |
| Max Extended Sample Length | 1050 mm |
| Dimensions (L×W×H) | 1710 × 850 × 940 mm |
| Power Supply | 1∮ AC 220 V, ~100 W |
| Control System | PLC with 7-inch HMI touchscreen |
| Data Output | USB export (CSV format) |
| Cycle Count Range | 1–999,999 (user-definable) |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HAIDA HD-F761 Tri-Station Sofa Fatigue Testing Machine |
| Quotation | Upon Request |
| Load Capacity | 2 kN × 4 sensors |
| Force Range (Backrest) | 50–900 N |
| Force Range (Seat) | 100–1700 N |
| Static Load (Backrest, GB) | 410–700 N |
| Static Load (Backrest, EN) | 450 N |
| Static Load (Seat, GB/EN) | 1200–1600 N / 1300 N |
| Durability Load (Backrest, GB/EN) | 330 N / 300 N |
| Durability Load (Seat, GB/EN) | 950 N / 1000 N |
| Control System | PLC-based with HMI touchscreen interface |
| Max Sample Dimensions | 2500 × 1200 × 1200 mm (L×W×H) |
| Seat Height Adjustment Range | 280–500 mm |
| Test Frequency | 1–20 cycles/min (adjustable per dwell time requirement) |
| Cycle Count Setting Range | 1–999,999 cycles |
| Overall Dimensions | ~3000 × 1810 × 1830 mm (L×W×H) |
| Weight | 750 kg |
| Power Supply | 1∮ AC 220 V |
| Pneumatic Supply | ≥0.6 MPa |
| Total Power Consumption | ~200 W |
| Compliance Standards | BS EN 1335-3:2009, BS EN 12520:2015, EN 1728:2012, QB/T 2280–2016, GB 10357.3–2013, IKEA TEST METHOD 0028 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | HAIDA HD-F764 Mattress Rolling Endurance Tester |
| Capacity | 2 kN |
| Force Sensor | 1× high-precision load cell |
| Motor | 1.5 kW three-phase AC motor |
| Electric Cylinder Stroke | 350 mm (max thrust: 1 kN) |
| Control System | PLC-based industrial controller |
| Display | 10.1″ capacitive touch HMI |
| Test Frequency | 1–20 cycles/min (GB/EN: 16 ± 2 cpm |
| ASTM F1566 | 20 cpm max) |
| Rolling Amplitude | GB/EN: ±250 mm from centerline |
| ASTM | total lateral travel = 70% of mattress width (≤965 mm) |
| Rolling Drive | Three-phase motor + precision roller chain transmission |
| Thickness & Compression Loss Measurement | displacement resolution ±0.1 mm |
| Firmness Testing Accuracy | displacement resolution ±0.1 mm |
| Roller Assembly | electric hoist-lifted cylindrical roller (static load: 1400 ± 7 N) or hexagonal roller (static load: 109 ± 4 kg) |
| Fatigue Cycles | cylindrical roller — up to 30,000 cycles |
| Data Export | USB 2.0 interface |
| Max Test Specimen Size | 2200 × 2000 × 400 mm (L×W×H) |
| Power Supply | 3-phase AC 380 V / 50 Hz |
| Total Power Consumption | ~1.8 kW |
| Dimensions (L×W×H) | 2800 × 2500 × 2500 mm |
| Weight | ~1500 kg |
| Compliance Standards | QB/T 1952.2–2011, GB/T 26706–2011, EN 1957:2012, ASTM F1566–2014 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HAIDA HD-F764-S Mattress Rolling Durability Tester (Touchscreen Tri-Function System) |
| Quotation | Upon Request |
| Force Sensor | 2 × 2 kN |
| Servo Motor Power | 0.4 kW (softness/thickness), 1.5 kW (rolling) |
| Electro-Cylinder Stroke | 450 mm, Max Thrust: 1.39 kN |
| Control System | Industrial PLC with HMI Touchscreen |
| Test Speed | 10–18 cycles/min (GB/EN: 16 ± 2 cpm |
| ASTM | ≤20 cpm) |
| Rolling Travel | GB/EN: ±250 mm from centerline |
| ASTM | min(70% mattress width, 965 mm) |
| Displacement Accuracy | ±0.1 mm |
| Loading Speed (Thickness/Softness) | 50–250 mm/min |
| Force Accuracy | 0.1–480 N (±0.1 N), 0.1–1300 N (±0.1 N) |
| Edge Durability Load | 1000 N × 5000 cycles (1–3 s dwell per cycle) |
| Roller Static Load | Cylindrical roller: (1400 ± 7) N |
| Hexagonal roller (optional) | 109 ± 4 kg |
| Rolling Fatigue Life | 30,000 cycles (cylindrical), 100,000 cycles (hexagonal) |
| Data Export | USB interface |
| Max Test Specimen | 2200 × 2000 × 400 mm (L×W×H) |
| Power Supply | 1-phase AC 220 V, 50 Hz |
| Total Power Consumption | ~2.2 kW |
| Required Air Pressure | ≥6 bar |
| Dimensions (L×W×H) | 2650 × 2340 × 2150 mm (height extends to 2670 mm with roller raised) |
| Net Weight | ~1400 kg |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HAIDA HD-F766 Cornell Mattress Durability Tester |
| Quotation | Upon Request |
| Load Capacity | 2 kN |
| Sensor Vertical Speed | 20–300 mm/min |
| Test Speed | 1–165 rpm |
| Force Range | 1 N–2 kN |
| Display | Touchscreen Interface |
| Control System | PLC-based Embedded Controller |
| Data Output | USB 2.0 Port |
| Cycle Count Range | 1–999,999 Cycles (User-Programmable) |
| Eccentric Cam Stroke Adjustment | 0–200 mm |
| Test Chamber Dimensions | 2200 mm × 2200 mm × 400 mm (L×W×H) |
| Overall Dimensions | Approx. 3620 mm × 2440 mm × 2700 mm (L×W×H) |
| Power Supply | Single-phase AC 220 V |
| Weight | Approx. 900 kg |
| Rated Power Consumption | ~1.3 kW |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HAIDA HD-F767 Sofa Drop Tester |
| Quotation | Available upon Request |
| Lift Height Adjustment Range | 75–300 mm |
| Cylinder Bore Diameter | 63 mm |
| Maximum Operating Pressure | 0.6 MPa |
| Overall Dimensions (L×W×H) | 1400 × 1200 × 1800 mm |
