Harvard Apparatus
Filter
Showing all 12 results
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Gemini SC2 |
| Waveforms | Square Wave & Exponential Decay Wave |
| Voltage Range (LV) | 5–500 V (1 V step), 505–3000 V (5 V step) |
| Voltage Range (HV) | 10–500 V (5 V step), 510–3000 V (10 V step) |
| Pulse Duration (Square, LV) | 10 µs–999 µs (1 µs), 1 ms–999 ms (1 ms) |
| Pulse Duration (Square, HV) | 10 µs–600 µs (1 µs) |
| Pulse Duration (Exponential, LV) | 1.25 ms–3.275 s (1.25 ms) |
| Pulse Duration (Exponential, HV) | 0.5 ms–50 ms (0.5 ms) |
| Pulse Number (Square) | 1–10 (LV), 1–3 (HV) |
| Pulse Number (Exponential) | 1–12 (R < 100 Ω), 1–24 (R > 100 Ω) |
| Pulse Interval | 0.1–10 s (Square), 5–30 s (Exponential) |
| Capacitance (LV) | 3775 µF (fixed) |
| Capacitance (HV) | 85 µF (fixed) |
| Capacitance (Exponential, LV) | 25–3275 µF (25 µF step) |
| Capacitance (Exponential, HV) | 10, 25, 50 µF (selectable) |
| Resistance Measurement Range | 25–1575 Ω (25 Ω step, LV) |
| Display | Touchscreen Interface |
| Preloaded Protocols | Yes |
| Arc Suppression | Active |
| Short-Circuit Protection | Integrated |
| Compliance | CE, RoHS, FDA-listed device (Class II) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Gemini X2 |
| Waveforms | Square Wave & Exponential Decay Wave |
| Voltage Range (LV) | 5–500 V (1 V step), 505–3000 V (5 V step) |
| Voltage Range (HV) | 505–3000 V (5 V step) |
| Pulse Duration (Square, LV) | 10 µs–999 µs (1 µs), 1 ms–999 ms (1 ms) |
| Pulse Duration (Square, HV) | 10 µs–600 µs (1 µs) |
| Pulse Duration (Exponential, LV) | 1 ms–5.158 s |
| Pulse Duration (Exponential, HV) | 0.5 ms–133.875 ms |
| Pulse Count (Square) | 1–10 (LV), 1–3 (HV) |
| Pulse Count (Exponential) | 1–12 (R < 100 Ω), 1–24 (R > 100 Ω) |
| Inter-Pulse Interval | 0.1–10 s (Square), 5–30 s (Exponential) |
| Capacitance (LV) | 3775 µF |
| Capacitance (HV) | 85 µF |
| Capacitance (Exponential, LV) | 25–3275 µF (25 µF step) |
| Capacitance (Exponential, HV) | 10, 25, 35, 50, 60, 75, 85 µF |
| Resistance Measurement Range | 25–1575 Ω (25 Ω step, LV), 50–1575 Ω (25 Ω step, HV) |
| Electrode Compatibility | BTX standard cuvettes, in vivo electrodes, MOS 96-well electroporation plates, footswitch |
| Software Control | USB and Ethernet interface for protocol download, storage, and remote execution |
| Safety Features | Arc suppression, short-circuit protection, real-time impedance monitoring |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | AS-01-006 |
| Oxygen Inlet Pressure | 50 PSI (fixed) |
| Max Oxygen Flow | 50 LPM (safety-limited) |
| Adjustable O₂ Flow Range | 0–4 LPM |
| Isoflurane Vaporizer Range | 0.5–5.0% |
| CO₂ Absorber Capacity | 3 lb (1.36 kg) |
| Dimensions (L×W×H) | 40 × 35.5 × 85 cm |
| Compliance | ASTM F2739, ISO 80601-2-13, USP <1211>, GLP-ready design |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | CDS 9000 |
| Certification | CE, ISO 13485 |
| Gas Flow Range | 0.2–4 L/min (O₂) |
| Vaporizer | Original 100 Series or TECH3 Isoflurane Vaporizer (≥250 mL, output accuracy ±0.5%) |
| CO₂ Absorbent Canister Capacity | ≥900 mL |
| Pressure Gauge Range | 0–60 cm H₂O |
| Circuit Type | Dual-path F-circuit with integrated Pop-off valve (2 cm H₂O constant negative pressure) |
| Construction | Anodized matte-finish aluminum chassis |
| Compliance | FDA-recognized materials (NASA-derived loop board), USP <1210> compatible design |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PLI-10 |
| Input Pressure Range | 480–720 kPa (70–105 psi) |
| Output Pressure Range | 2.8–413 kPa (0.2–60 psi), continuously adjustable |
| Pulse Width Resolution | 10 ms (0.01–0.99 s) |
| Injection Count Display | 0–9999 (digital LED) |
| Trigger Modes | Front-panel knob, foot switch, external TTL pulse via BNC input |
| Operating Mode | Timed pulse or continuous gate-controlled duration |
| Pressure Release | Multi-turn manual regulator with bidirectional control |
| Compliance | Designed for GLP-compliant electrophysiology and microinjection workflows |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PP35-2P |
| Type | Adherent-cell-specific electroporation electrode |
| Compatibility | Standard 35 mm Petri dishes with 2 mm gap electrodes |
| Application | In situ transfection of monolayer-cultured mammalian cells |
| Configuration | Dual parallel plate electrode assembly |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Pump 11 Elite Nanomite |
| Type | Micro-syringe Pump |
| Accuracy | ±0.5% |
| Flow Rate Range | 3.66 pL/min to 3.82 mL/min |
| Maximum Linear Force | 5 kg (11 lbf) |
| Syringe Volume Range | 0.5 µL to 1 mL |
| Display | 4.3" WQVGA TFT Color Touchscreen |
| Interfaces | RS-485, USB Type B, Digital I/O (15-pin D-Sub), Footswitch Input (3.5 mm audio jack) |
| Power Input | 12–30 VDC |
| Regulatory Certifications | CE, ETL (UL/CSA), WEEE, RoHS, CB Scheme |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Pump 11 Pico Plus Elite |
| Type | Programmable dual-channel infusion/withdrawal syringe pump |
| Accuracy | ±0.35% |
| Flow Rate Range (single-channel) | 0.54 pL/min to 39.77 mL/min |
| Flow Rate Range (dual-channel) | 0.54 pL/min to 11.70 mL/min |
| Syringe Capacity (single) | 0.5 µL – 60 mL |
| Syringe Capacity (dual) | 0.5 µL – 10 mL |
| Max Linear Force | 16 kg (35 lb) |
| Display | 4.3" WQVGA TFT color touchscreen |
| Interfaces | RS-485, USB Type B, 15-pin D-Sub I/O & TTL, footswitch input, optional RS-232 (RJ-11) |
| Power Input | 12–30 VDC |
| AC adapter | 100–240 VAC, 50/60 Hz, 18 W |
| Dimensions (H×L×W) | 22.6 × 17.78 × 15 cm |
| Weight | 2.1 kg |
| Certifications | CE, ETL (UL/CSA), WEEE, EU RoHS, CB Scheme |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Table Top |
| Gas Delivery System | Non-rebreathing, single-circuit |
| Vaporizer Type | TECH3 Isoflurane/Sevoflurane |
| Flow Range | 0–1000 mL/min (O₂) |
| Vapor Output Range | 0.5–5% |
| Weight | ~10 kg (unit + vaporizer) |
| Safety Features | Vaporizer lockout, visual drug level window, activated carbon scavenging system |
| Compliance | ASTM F2749-22 (Anesthetic Equipment), ISO 80601-2-13:2021 (Medical Electrical Equipment – Particular Requirements for Anesthetic Workstations) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | TC-3000 |
| Input Channels | Single or Triple Thermocouple |
| Temperature Range (Single-Channel) | 25.0–45.0 °C (0.1 °C resolution, Celsius only) |
| Temperature Range (Triple-Channel) | −10.0 to +60.0 °C (14.0 to 140.0 °F), 0.1 °C resolution |
| Sampling Rate | 3 Hz per channel |
| Power Supply | 4 × C-cell batteries (included) |
| Output | Analog voltage output (0–5 V DC, proportional to temperature) |
| Display | Front-panel LCD with manual channel selection |
| Compliance | CE-marked, RoHS-compliant, designed for laboratory use under GLP conditions |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE8815 / LE8816 |
| External Dimensions | 450 × 450 × 200 mm or 220 × 220 × 200 mm |
| Infrared Frame Options | 450 × 450 mm (32 sensors, 25 mm spacing) or 250 × 250 mm (32 sensors, 13 mm spacing) |
| IR Wavelength | 950 nm |
| Sampling Frequency | 40 Hz |
| Software | Acti-Track v5.x |
| Max Concurrent Channels | 32 |
| Configurable Zones | Single-animal or dual-animal (split-zone) mode |
| Behavioral Metrics | Distance traveled, velocity profiles (max/min/mean), time-in-zone, zone entries, rearing count & duration, rotation counts, trajectory-based path analysis, nose-poke detection (threshold-defined), ambulation classification (fast/slow/immobility) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SurgiVet V6004 |
| Pricing | Available Upon Request |