| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | Gene Pulser Xcell |
| High Voltage Range | 3000 V |
| Low Voltage Range | 10 V |
| Pulse Duration | 0.05–10 ms (0.05 ms increments) for 10–500 V |
| Number of Pulses | 1–10 (0.1–10 s interval for 10–500 V) |
| Capacitance | 25–3275 µF (25 µF increments) at 10–500 V |
| Resistance | 50–1000 Ω (50 Ω increments) + ∞ |
| Brand | Bio-Rad |
|---|---|
| Model | Helios |
| Origin | USA |
| Type | Handheld Particle-Mediated Gene Delivery System |
| Operating Pressure Range | 100–600 psi |
| Safety Relief Valve Setpoint | 700 ± 35 psi |
| Max. Helium Pressure Adjustment | 800 psi |
| Power Supply | 9 V Alkaline Battery (rechargeable optional) |
| Battery Life | ≥1,000 discharges |
| Max. Discharge Current | 10 mA (gun unit) |
| Input Voltage | 100–120 V or 220–240 V AC, 50/60 Hz |
| Cartridge Spinning Speed | 30 rpm |
| Gold Particle Diameters | 0.6, 1.0, and 1.6 µm |
| PVP Coating Mass | 0.5 g per kit |
| Desiccant | Spherical drying agent (5 units) |
| Cartridge Capacity | 12 firings per chamber |
| Kit Contents | 1,000 pre-loaded cartridges, 50 ft (~26 m) gold-coated tubing, 5 gene storage vials |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | MicroPulser |
| High Voltage Range | 300–3000 V |
| Low Voltage Range | 200–2500 V |
| Pulse Duration | 0.1–5.0 ms (adjustable in 0.1 ms increments) |
| Capacitance Settings | 100, 250, 500, and 1000 µF |
| Internal Resistance | Fixed ~100 Ω (optimized for standard electroporation cuvettes) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | PDS-1000/HE |
| Helium Pressure Range | 450–2200 psi |
| Vacuum Chamber | Adjustable to ≤29 inHg (737 mmHg) |
| Carrier Disk Diameter | 13 mm |
| Stopping Screen Material | Stainless Steel Mesh (100 µm pore) |
| Microprojectile Size Compatibility | 0.6–1.6 µm (Au or W) |
| Pulse Duration | <1 ms (transient helium shockwave) |
| Capacitance | Not applicable (gas-driven, non-electrical acceleration) |
| Resistance | Not applicable (pneumatic system) |
| Brand | BLS |
|---|---|
| Origin | EU-manufactured |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | European Union |
| Model | CF150B |
| Pricing | Available upon Request |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | ECM 830 |
| High Voltage Range | 505–3000 V |
| Low Voltage Range | 5–500 V |
| Pulse Duration | 10 ms–10 s |
| Capacitance | 111 µF |
| Resistance | 25 Ω |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | ECM2001 |
| Type | Dual-Mode Electroporator/Electrofusion Instrument |
| Compliance | Designed for GLP-compliant cell manipulation workflows |
| Software Interface | Analog control with manual pulse parameter adjustment |
| Pulse Modes | AC pre-alignment, DC square-wave fusion, AC post-aggregation |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | ECM2001+ |
| High-Voltage Range | 505–3000 V |
| Low-Voltage Range | 5–500 V |
| Pulse Duration | 10 µs–999 ms |
| Resistance Setting | 1 Ω |
| Compliance | CE, FDA-listed device for research use only |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | ECM399 |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ECM630 |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | ECM830 |
| High-Voltage Mode | 50–3000 V (5 V step), 56 Ω, 111 µF, pulse width 10–600 µs (1 µs resolution) |
| Low-Voltage Mode | 5–500 V (1 V step), 56 Ω, 4000 µF, pulse width 10–999 µs / 1–999 ms / 1–10 s (1 µs / 1 ms / 0.1 s resolution) |
| Pulse Number | 1–99 |
| Inter-Pulse Interval | 100 ms–10 s |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Gemini SC |
| Price Range | USD 68,000 – 109,000 |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Gemini SC2 |
| Waveforms | Square Wave & Exponential Decay Wave |
| Voltage Range (LV) | 5–500 V (1 V step), 505–3000 V (5 V step) |
| Voltage Range (HV) | 10–500 V (5 V step), 510–3000 V (10 V step) |
| Pulse Duration (Square, LV) | 10 µs–999 µs (1 µs), 1 ms–999 ms (1 ms) |
| Pulse Duration (Square, HV) | 10 µs–600 µs (1 µs) |
| Pulse Duration (Exponential, LV) | 1.25 ms–3.275 s (1.25 ms) |
| Pulse Duration (Exponential, HV) | 0.5 ms–50 ms (0.5 ms) |
| Pulse Number (Square) | 1–10 (LV), 1–3 (HV) |
| Pulse Number (Exponential) | 1–12 (R < 100 Ω), 1–24 (R > 100 Ω) |
| Pulse Interval | 0.1–10 s (Square), 5–30 s (Exponential) |
| Capacitance (LV) | 3775 µF (fixed) |
| Capacitance (HV) | 85 µF (fixed) |
| Capacitance (Exponential, LV) | 25–3275 µF (25 µF step) |
| Capacitance (Exponential, HV) | 10, 25, 50 µF (selectable) |
| Resistance Measurement Range | 25–1575 Ω (25 Ω step, LV) |
| Display | Touchscreen Interface |
| Preloaded Protocols | Yes |
| Arc Suppression | Active |
| Short-Circuit Protection | Integrated |
| Compliance | CE, RoHS, FDA-listed device (Class II) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Gemini X2 |
| Waveforms | Square Wave & Exponential Decay Wave |
| Voltage Range (LV) | 5–500 V (1 V step), 505–3000 V (5 V step) |
| Voltage Range (HV) | 505–3000 V (5 V step) |
| Pulse Duration (Square, LV) | 10 µs–999 µs (1 µs), 1 ms–999 ms (1 ms) |
| Pulse Duration (Square, HV) | 10 µs–600 µs (1 µs) |
| Pulse Duration (Exponential, LV) | 1 ms–5.158 s |
| Pulse Duration (Exponential, HV) | 0.5 ms–133.875 ms |
| Pulse Count (Square) | 1–10 (LV), 1–3 (HV) |
| Pulse Count (Exponential) | 1–12 (R < 100 Ω), 1–24 (R > 100 Ω) |
| Inter-Pulse Interval | 0.1–10 s (Square), 5–30 s (Exponential) |
| Capacitance (LV) | 3775 µF |
| Capacitance (HV) | 85 µF |
| Capacitance (Exponential, LV) | 25–3275 µF (25 µF step) |
| Capacitance (Exponential, HV) | 10, 25, 35, 50, 60, 75, 85 µF |
| Resistance Measurement Range | 25–1575 Ω (25 Ω step, LV), 50–1575 Ω (25 Ω step, HV) |
| Electrode Compatibility | BTX standard cuvettes, in vivo electrodes, MOS 96-well electroporation plates, footswitch |
| Software Control | USB and Ethernet interface for protocol download, storage, and remote execution |
| Safety Features | Arc suppression, short-circuit protection, real-time impedance monitoring |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | Gemini X2 |
| High-Voltage Range | ±3000 V |
| Low-Voltage Range | 5 V |
| Pulse Duration | 10 µs – 999 ms |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MOS High-Throughput Multiwell Electroporation System |
| Quotation | Available Upon Request |
| Pulse Generator Compatibility | ECM630 & ECM830 |
| MOS Plate Formats | 25-well & 96-well |
| MOS Plate Processor Models | HT-100 (manual column-by-column pulsing) & HT-200 (automated sequential column pulsing) |
| Voltage Range | 0–3000 V DC |
| Pulse Duration | 10 µs – 10 s |
| Number of Pulses | 1–99 |
| Electrode Architecture | Patented composite electrode array with cross-contamination mitigation design |
| Included Accessories | Sterile plate lid for contamination control |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | BTX Hybrimune |
| Capacity Options | 2 mL (microscope-compatible transparent chamber) & 9 mL fusion chambers |
| AC Pre-Fusion Pulse | 0.2–2.0 MHz (0.2 MHz step), 5–75 V (0.1 V step), 0–60 s (1 s step), non-sinusoidal ramp-up waveform |
| AC Post-Fusion Pulse | same frequency/voltage range, ramp-down waveform |
| DC Fusion Pulse | square wave, 100–1000 V (5 V step), 20–1000 µs (10 µs step), 0–10 pulses, 0.125–10 s inter-pulse interval |
| Cycles | 1–10 sets |
| Operating Temperature | 20–30 °C |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Hybrimune Large-Scale Fusion System |
| Pricing | Available Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | BTX MAX Transfection System |
| Pricing | Available Upon Request |
| Electroporation Chamber Gap | 4 mm |
| Sample Volume Range | 2–6 mL |
| Voltage Range | 50–1200 V |
| Pulse Duration | 0.05–10 ms |
| Inter-Pulse Interval | 0.2–1000 ms (1 Hz–5 kHz) |
| Data Interface | USB Flash Drive Support |
| Control Interface | Capacitive Touchscreen |
| Brand | Calibre |
|---|---|
| Origin | Germany |
| Model | Eporator |
| Voltage Presets | P1 = 1700 V, P2 = 2500 V |
| Display | Color LCD Interface |
| Safety | Integrated Electrode Slot with Leakage Protection |
| Compliance | GLP-Compliant Data Logging via USB |
| Dimensions | Compact Benchtop Form Factor |
| Regulatory Status | Import-Class Life Science Instrument for Transfection and Cell Fusion Applications |
| Brand | Calibre |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PiezoXpert |
| Pricing | Upon Request |
| Brand | Calibre |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | TransferMan 4r |
| Price Range | USD 13,500 – 40,500 (est. based on EUR/¥ conversion) |
| High-Voltage Range | Not applicable |
| Low-Voltage Range | Not applicable |
| Pulse Duration | Not applicable |
| Capacitance (µF) | Not applicable |
| Resistance | Not applicable |
| Brand | Chengmeng |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MEP Microelectrode-Based Electroporation System |
| High-Voltage Range | 0–1200 V (adjustable) |
| Low-Voltage Range | 0–50 V (for pre-pulse stabilization) |
| Capacitance Range | 1–100 µF (selectable) |
| Pulse Duration | 1–100 ms (adjustable) |
| Number of Pulses | 1–99 per cycle |
| Pulse Interval | 100 ms–5 s (programmable) |
| Output Waveform | Exponential decay and square-wave modes |
| Internal Resistance | <50 Ω (system-optimized for microelectrode coupling) |
| Electrode Compatibility | Standard 1.0 mm OD borosilicate capillaries (Sutter BF150-86-10, World Precision Instruments TW-100F, etc.) |
| Embryo Survival Rate (Mouse 2-cell stage) | 80–85% post-electroporation |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | CellTram |
| Pricing | Contact Authorized Distributor |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Model | Eporator |
| Voltage Range | 200–2500 V |
| Pulse Duration | 5 ms |
| Capacitance | 10 µF |
| Resistance | 600 Ω |
| Pulse Waveform | Exponential Decay |
| Dimensions (W×D×H) | 19 × 27.5 × 12.5 cm |
| Weight | 3.2 kg |
| Power Supply | 100–240 V, 50–60 Hz |
| Interface | USB 2.0 |
| Brand | Etta Biotech |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | X-Porator F1 |
| Price Range | USD 110,000 – 138,000 (FOB) |
| High-Voltage Range | 30–600 VDC |
| Low-Voltage Range | 30–600 VDC |
| Output Waveform | Square Wave |
| Cell Processing Volume | 3–250 mL per run |
| Cell Capacity | 1.5×10⁷–1.0×10¹⁰ viable eukaryotic cells per run |
| Recommended Cell Density | 1×10⁸ cells/mL |
| Compatible Vessels | Corning 15 mL, 50 mL, and 250 mL conical centrifuge tubes |
| Flow Rate | 1–50 mL/min |
| Input Voltage | 210–240 VAC |
| Operating System | Embedded Linux |
| Dimensions (W×D×H) | 623 × 452 × 325 mm |
| Weight | 28 kg |
| Brand | Etta Biotech |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | X-Porator H1 |
| High-Voltage Range | 30–600 VDC |
| Low-Voltage Range | 30–600 VDC |
| Output Waveform | Square Wave |
| Cell Throughput | 3–250 mL per run |
| Recommended Cell Density | 1 × 10⁸ cells/mL |
| Compatible Vessels | Corning 15 mL, 50 mL, and 250 mL centrifuge tubes |
| Flow Rate | 1–50 mL/min |
| Input Voltage | 210–240 VAC |
| Control Software | X-Porator F1 (Linux-based) |
| Dimensions (W × D × H) | 623 × 452 × 325 mm |
| Weight | 28 kg |
| Brand | Etta Biotech |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | X-Porator M1 |
| Output Waveform | Square Wave |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BTX 384L |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | BTX Electrofusion Electrodes |
| Voltage Range | 0–500 V DC (Microslides), 0–480 V DC / 0–16 V AC (Meander & Flat Chambers) |
| Pulse Duration | 1 µs – 99 ms |
| Pulse Count | 1–99 |
| Electrode Gaps | 0.2 mm (Meander), 0.5 / 1.0 / 3.2 / 10.0 mm (Microslides), 1.0 mm (Flat Chamber) |
| Field Uniformity | Non-uniform (Microslides, Meander, Flat in fusion mode), Uniform (Flat in electroporation mode) |
| Sample Volume Capacity | 20–2200 µL (Microslides), 5–20 µL (Meander), 500 µL (Flat Chamber) |
| Compatible Systems | ECM830, ECM2001 |
| Reusability | Yes (with mild cleaning) |