Heineu (Jihepu)
Filter
Showing all 4 results
| Brand | Heineu (Jihepu) |
|---|---|
| Origin | Shandong, China |
| Model | LS-100HG |
| Sterilization Chamber Volume | 100 L (Φ440 × 650 mm) |
| Maximum Operating Temperature | 134 °C |
| Maximum Working Pressure | 0.22 MPa |
| Temperature Uniformity | ≤ ±1 °C |
| Timer Range | 0–99 min or 0–99 h 59 min |
| Temperature Setpoint Range | 0–134 °C (sterilization), 50–101 °C (boiling) |
| Power Supply | 4500 W / AC 220 V, 50 Hz |
| External Dimensions | 730 × 510 × 1270 mm |
| Net Weight | 110 kg |
| Safety Interlock | Door lock activated at >0.027 MPa internal pressure |
| Heating Method | External steam generator with dry-heating element |
| Steam Cycle | Internal recirculation (no external venting) |
| Compliance | Designed to meet ISO 17665-1:2019 (Moist heat sterilization), EN 285:2015 (Large steam sterilizers), and GLP/GMP-relevant operational safeguards |
| Brand | Heineu (Jihepu) |
|---|---|
| Origin | Shandong, China |
| Model | LS-120LD |
| Sterilization Chamber Volume | 120 L |
| Maximum Operating Temperature | 134 °C |
| Maximum Operating Pressure | 0.22 MPa |
| External Dimensions | 600 × 640 × 1140 mm |
| Heating Power | 6 kW |
| Supply Voltage | AC 220 V, 50 Hz |
| Temperature Uniformity | ≤ ±1 °C |
| Timer Range | 0–99 min |
| Temperature Control Range (Sterilization) | 105–134 °C |
| Temperature Control Range (Boiling Mode) | 50–101 °C |
| Safety Features | Dry-run overheat protection, pressure relief valve, current overload cutoff, earth leakage protection |
| Net Weight | 100 kg |
| Gross Weight | 125 kg |
| Brand | Heineu (Jihepu) |
|---|---|
| Origin | Shandong, China |
| Model | LS-120SV |
| Sterilizer Type | Vertical |
| Chamber Volume | 120 L |
| Max Operating Temperature | 134 °C |
| Max Working Pressure | 0.22 MPa |
| External Dimensions | 840 × 600 × 1060 mm |
| Net Weight | 295 kg |
| Gross Weight | 325 kg |
| Elevating Door Height (Raised) | 1565 mm |
| Temperature Uniformity | ≤ ±1 °C |
| Cycle Time Range | 0–99 min |
| Temperature Setpoint Range | 105–134 °C |
| Steam Generator Power | 3.6 kW |
| Drying Heater Power | 2.4 kW |
| Supply Voltage | AC 220 V, 50 Hz |
| Vacuum Limit | –0.080 MPa |
| Filter | Sartorius midisart® 2000, 0.20 µm hydrophobic membrane |
| PT/TT Test Port | Standard compliant |
| Steam Supply | Integrated electric steam generator |
| Air Replacement | Pulsed vacuum (downward exhaust with multi-cycle vacuum pulses) |
| Brand | Heineu (JIHEPU) |
|---|---|
| Origin | Shandong, China |
| Model | LS-60SV |
| Sterilization Chamber Volume | 60 L |
| Maximum Operating Temperature | 134 °C |
| Maximum Working Pressure | 0.22 MPa |
| External Dimensions | 686 × 556 × 913 mm |
| Net Weight | 180 kg |
| Power Supply | AC 220 V, 50 Hz |
| Steam Generator Power | 3 kW |
| Drying Heater Power | 2.4 kW |
| Temperature Uniformity | ≤ ±1 °C |
| Vacuum Level (Pulsed Cycle) | –0.080 MPa |
| Cycle Time Range | 0–99 min |
| Temperature Setpoint Range | 105–134 °C |
| Sterilization Mode | Saturated Steam with Pulsed Vacuum Pre-vacuum & Post-vacuum Drying |
| Control Interface | 7-inch Capacitive Touchscreen |
| Air Filtration | Sartorius midisart® 2000, 0.20 µm hydrophobic membrane filter |
| Compliance Interfaces | Standard PT/TT test ports per ISO 17665-1 and EN 285 |