IMR
Filter
Showing all 4 results
| Brand | IMR |
|---|---|
| Origin | USA |
| Model | 2800P |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±2% FS |
| Response Time | <90 s |
| Drift Stability | <5% over 1 h |
| Measured Parameters | O₂, NO, NO₂, CO, SO₂, HC/CH₄, Flue Gas Temperature (TG), Ambient Temperature (TA) |
| Sensor Technology | Electrochemical (O₂, NO, NO₂, CO, SO₂, HC/CH₄) |
| Operating Temperature Range (Probe) | Up to 1200 °C (1600 °C optional) |
| Battery Life | 6 h (rechargeable Li-ion) |
| Compliance | Certified for official emission monitoring per German TA Luft and EU Directive 2010/75/EU (IED), supports ASTM D6522, EN 15267-3, and VDI 3862 |
| Data Output | RS232, USB |
| Display | Backlit LCD showing up to 8 parameters simultaneously |
| Built-in Printer | Yes (programmable, on-site thermal printout) |
| Fuel Database | 23 preloaded fuel types + 4 user-definable |
| Calculated Parameters | λ (excess air ratio), qA (dry flue gas loss), CO₂ (by ASME PTC 4.1 equation), NOₓ (as NO₂-equivalent) |
| Brand | IMR |
|---|---|
| Origin | USA |
| Model | IMR1400C |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | <2% FS |
| Repeatability | <2% FS |
| Response Time | 1 s |
| Stability | <2% FS over 8 h |
| Measurable Gases | O₂, NO, NO₂, CO, SO₂, HC/CH₄ |
| Optional Sensors | HCl, N₂O, Cl₂, H₂, NH₃, H₂S, CO₂ (IR) |
| Operating Temperature Range | –20 °C to +1200 °C (flue gas), –20 °C to +120 °C (ambient) |
| Dimensions | 305 × 228.6 × 117 mm |
| Weight | 2.9 kg |
| Battery Life | Up to 6 h (rechargeable Li-ion) |
| Communication Interfaces | RS232, USB |
| Compliance | Certified for official emissions monitoring per German TA-Luft and EU EN 15267-3 |
| Brand | IMR |
|---|---|
| Origin | USA |
| Model | IMR5000 |
| Instrument Type | Flue Gas CEMS |
| Measurement Accuracy | <2% FS |
| Repeatability | <2% FS |
| Stability | <2% FS |
| Response Time | Real-time |
| Measured Parameters | O₂, NO, NO₂, CO, SO₂, HC, CH₄, H₂S, HCl, NH₃, N₂O, O₃, PM |
| Sensor Technologies | Electrochemical (O₂, NO, NO₂, CO, SO₂, H₂S, NH₃, HCl, N₂O, O₃), NDIR (CH₄, CO₂*), Catalytic Bead (HC), Optional Paramagnetic (O₂), Thermal Conductivity (H₂), Optical Scattering (PM) |
| Brand | IMR |
|---|---|
| Origin | USA |
| Model | IMREX660 |
| Instrument Type | Portable Flue Gas Analyzer |
| Accuracy | <2% FS |
| Repeatability | <2% FS |
| Response Time (T90) | <30 s |
| Stability | <2% FS over 8 h |
| Operating Temperature | –20°C to +50°C (toxic gases) |
| Operating Humidity | <95% RH, non-condensing |
| Weight | 500 g |
| Dimensions | 168 × 91 × 45 mm |
| Data Storage Capacity | 100,000 records |
| Battery Life | Up to 30 h (rechargeable Li-ion) |
| Detection Methods | Electrochemical, Catalytic Bead, NDIR, PID, and Semiconductor Sensors |
| Gas Channels | Up to 6 simultaneous sensor modules (7 gas parameters concurrently) |
| Alarm Modes | Dual-stage audible (buzzer), visual (LED flash), and tactile (vibration) |
| Compliance | Certified per German TA-Luft emission guidelines |