| Brand | Instec |
|---|---|
| Origin | USA |
| Model | AirAware |
| Enclosure Rating | NEMA 4 |
| Power Supply | 12–24 VDC (optional 110/120 VAC adapter with North American plug) |
| Operating Temperature | −20 °C to 50 °C (−4 °F to 122 °F) |
| Humidity Range | 0–99% RH (non-condensing |
| Dimensions | 18.29 cm × 14.22 cm × 4.06 cm (7.2″ × 5.6″ × 1.6″) |
| Weight | 454 g (16 oz) |
| Sensor Technology | Electrochemical |
| Gas Detection Capabilities | CO (0–999 ppm, 1 ppm res), H₂S (0–999 ppm, 1 ppm res), NO (0–999 ppm, 1 ppm res), NH₃ (0–200 ppm, 1 ppm res), O₂ (0–30% vol, 0.1% res), SO₂ (0.2–99.9 ppm, 0.1 ppm res), NO₂ (0.2–99.9 ppm, 0.1 ppm res), Cl₂ (0.2–50 ppm, 0.1 ppm res), ClO₂ (0–1 ppm, 0.01 ppm res), HCN (0.2–30 ppm, 0.1 ppm res), HCl (0.2–30 ppm, 0.1 ppm res), PH₃ (0–1 ppm, 0.01 ppm res) |
| Output Options | 4–20 mA analog output, Modbus RTU (RS-485), configurable relay outputs (SPDT), local audible alarm (user-enabled/disabled), dual-intensity visual alarm LEDs |
| Calibration | Non-intrusive, tool-free span calibration using certified gas standards |
| Housing | Epoxy-coated aluminum with RF interference shielding |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCC602S |
| Temperature Range | −60 °C to +200 °C |
| Temperature Stability | ±0.1 °C (at steady state) |
| Heating Rate | up to +120 °C/min |
| Cooling Rate | up to −30 °C/min |
| Stage Dimensions | 100 mm × 62 mm × 32.55 mm |
| Sample Area | Ø5 mm to Ø50 mm |
| Mass | 0.5 kg |
| Max Power Consumption | 150 W (heating mode) |
| Interface | USB 3.0, RS485 |
| Compatible Controller | mK2000B Multi-Stage PID Temperature Controller |
| Optional Accessories | K-type thermocouple, gas purge module, external water-cooling jacket |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCD301 |
| Temperature Range | −80 °C to +250 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C at 100 °C |
| Min. Heating/Cooling Rate | ±0.01 °C/h |
| Max. Heating Rate | +100 °C/min at 100 °C |
| Max. Cooling Rate | −50 °C/min at 100 °C |
| Control Method | Switching PID (LVDC PID optional) |
| Sensor | 100 Ω Platinum RTD |
| Working Distance | 6.2 mm (min. 3.5 mm with outer window removed) |
| Condenser Distance | 11.6 mm |
| Sample Area | 22 mm × 25 mm |
| Chamber Height | 5.0 mm (up to 12.5 mm with spacers) |
| Viewing Aperture Options | 2, 5, 8, and 10 mm |
| Optional X-Y Micropositioner | 10 µm resolution |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCP621G-PM |
| Temperature Range | -190 °C to 600 °C (LN₂ required for sub-ambient operation) |
| Heating/Cooling Rate | +80 °C/min (heating at 100 °C), -50 °C/min (cooling at 100 °C) |
| Temperature Stability | ±0.05 °C (>25 °C), ±0.1 °C (<25 °C) |
| Temperature Resolution | 0.01 °C |
| Control Sensor | 100 Ω Pt RTD |
| Control Method | PID with LVDC low-noise power supply |
| Heating Area | 28 mm × 30 mm |
| Sealing | Hermetic chamber (N₂ or inert gas compatible) |
| Optical Access | Removable φ38 mm viewport, ±60.7° viewing angle, 8.5 mm objective working distance |
| Electrical Interface | Standard BNC, optional triaxial for pA-level measurements |
| Probe Type | Manual lever-actuated Re-W bent probes |
| Sample Stage Grounding | Default grounded, optional floating or triaxial back-electrode configuration |
| Optional Modifications | Non-magnetic construction, internal feedthroughs, transmission-mode optical port, in-chamber wiring posts |
| Operation Mode | Manual probe positioning |
| Compliance | Designed for ASTM F1528, ISO/IEC 17025-aligned lab environments, supports GLP/GMP traceability via software SDK |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCS302 |
| Temperature Range | −190 °C to 400 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.01 °C at 100 °C |
| Max Heating Rate | +100 °C/min at 100 °C |
| Max Cooling Rate | −100 °C/min at 100 °C |
| Min Working Distance | 3.3 mm (outer window removed) |
| Operating Working Distance | 5.6 mm |
| Condenser Distance | 10.0 mm |
| Sample Area | 38 mm × 50 mm |
| Chamber Height | 2.0–12.5 mm (with optional spacers) |
| Viewing Aperture Options | 2 / 5 / 8 / 10 mm |
| Optional X-Y Micropositioner | 10 µm resolution |
| Temperature Sensor | 100 Ω Platinum RTD |
| Control Method | Switching PID (LVDC PID optional) |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCS402 |
| Temperature Range | -190 °C to 400 °C |
| Cooling Medium | Liquid Nitrogen (LN₂) |
| Heating Configuration | Dual-Zone Resistive Heating |
| Temp. Stability | ±0.5 °C at 100 °C |
| Temp. Accuracy | ±0.1 °C (full range) |
| Min. Temp. Resolution | 0.01 °C |
| Max. Heating Rate | +130 °C/min at 100 °C |
| Max. Cooling Rate | -80 °C/min at 100 °C (with LN2-P4 accessory) |
| Working Distance | ≥7.7 mm (objective), ≥10.0 mm (condenser) |
| Sample Area | 38 × 50 mm |
| Transmission Aperture Options | 2, 5, 8, or 10 mm diameter |
| Controller | STC200 (RS232 interface, 230 V input) |
| Optional Accessories | XY-A-01 Precision Positioner (10 µm resolution), LN2-P2UF2 Cryogenic Kit (2 L dewar + dual-stage pump), WP230C Recirculating Water Pump |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCS410 |
| Temperature Range | –60 °C to 400 °C |
| Temp. Resolution | 0.01 °C |
| Temp. Stability | ±0.02 °C at 100 °C |
| Max. Heating Rate | +50 °C/min |
| Max. Cooling Rate | –50 °C/min |
| Control Method | Switching PID (LVDC PID optional) |
| Sensor | 100 Ω Platinum RTD |
| Sample Area | 38 mm × 50 mm |
| Chamber Height | 2.0 mm / 6.0 mm (w/ spacers) |
| Viewing Aperture | 5 mm |
| Working Distance | 6.5 mm |
| Condenser Distance | 13 mm |
| X-Y Micropositioner (optional) | 10 µm resolution |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCS60 |
| Temperature Range | 5 °C to 60 °C (optional up to 95 °C) |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C at 37 °C |
| Max. Heating Rate | +50 °C/min at 37 °C |
| Max. Cooling Rate | −50 °C/min at 37 °C |
| Min. Heating/Cooling Rate | ±0.1 °C/hour |
| Control Method | PID with Variable Bipolar DC Control |
| Sensor | 100 Ω Platinum RTD |
| Working Distance | 5.6 mm (with optional insert) |
| Condenser Distance | 19.1 mm |
| Sample Area | 35 mm diameter |
| Chamber Height | 19 mm |
| Viewing Aperture | 13 mm (with insert), 20 mm (without insert) |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCS602 |
| Temperature Range | –190 °C to +600 °C (optional up to +700 °C) |
| Temperature Stability | ±0.1 °C at 100 °C |
| Minimum Temperature Resolution | 0.01 °C |
| Max Heating Rate | +200 °C/min at 100 °C |
| Max Cooling Rate | –130 °C/min at 100 °C (with LN2-P4 accessory) |
| Sample Area | 35 mm × 35 mm |
| Standard Optical Window | 20 mm × 20 mm |
| Optional Large Optical Window | 38 mm × 38 mm |
| Minimum Working Distance | Objective ≥ 5.3 mm, Condenser ≥ 10.0 mm |
| Controller | STC200 standalone unit with RS232 interface and Windows software |
| Software Support | LabVIEW drivers (IEEE-488 & RS232) included |
| Compliance | Designed for ASTM E2267, ISO 11357, and USP <1031> thermal microscopy applications |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCS622G |
| Temperature Range | −190 °C to +600 °C (optional up to +700 °C) |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.01 °C at 100 °C |
| Max. Heating Rate | 230 °C/min at 200 °C |
| Max. Cooling Rate | −130 °C/min at 200 °C |
| Min. Ramp Rate | ±0.1 °C/hour |
| Control Method | Switching PID (LVDC PID optional) |
| Sensor | 100 Ω Platinum RTD |
| Working Distance | 5.8 mm |
| Condenser Distance | 12.7 mm |
| Sample Area | 38 mm × 38 mm |
| Chamber Height | 0.76 mm (with inner cover) |
| Viewing Aperture | 26.5 mm (reflected light), 2.0 mm (transmitted light) |
| Vacuum Port | 1/8″ NPT female |
| Gauge Port | 1/8″ NPT female |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HSC302 |
| Temperature Range | −190 °C to +400 °C |
| Temperature Accuracy | ±0.1 °C (at 100 °C, 400 °C, and below ambient) |
| Temperature Stability | ±0.1 °C (at 100 °C) |
| Max Ramp Rate | ±100 °C/min |
| Min Ramp Rate | ±0.1 °C/h |
| Minimum Working Distance | >5.6 mm (objective), >10.0 mm (condenser) |
| Sample Size | 38 × 50 mm |
| Transmitted Light Aperture Options | 2, 5, 8, or 10 mm |
| Controller | STC200 (RS232 interface, 230 V input) |
| Accessories | XY Positioner (XY-A-01), Long Working Distance Polarizing Condenser (LWDC1, WD = 20 mm), 2 L LN₂ Cooling System (LN2-P2UF2), Circulating Water Pump (WP230C) |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | TSA02i |
| Temperature Range | –25°C to +60°C (optional extended range available) |
| Temperature Resolution | ±0.01°C at 37°C |
| Temperature Stability | ±0.1°C/hour |
| Max Heating Rate | +50°C/min at 37°C |
| Max Cooling Rate | –50°C/min at 37°C |
| Sample Area | 53 mm × 78 mm |
| Viewing Aperture | 17 mm (with sample plate), 40 mm (without sample plate) |
| Working Distance | 1.3 mm (standard), 2.8 mm (with sample plate), 14.6 mm (inner cover only) |
| Chamber Height | 12.8 mm (inner cover), 32 mm (outer cover) |
| Condenser Clearance | 35 mm (with outer cover), 14.6 mm (inner cover only) |