Jenway
Filter
Showing all 8 results
| Brand | Jenway |
|---|---|
| Origin | United Kingdom |
| Model | 3510 |
| Instrument Type | Benchtop |
| Parameter Type | Single-parameter (pH/mV/°C) |
| pH Range | –2.000 to +19.999 |
| pH Resolution | 0.001 / 0.01 / 0.1 |
| pH Accuracy | ±0.003 |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 / 1 mV |
| mV Accuracy | ±0.2 mV |
| Temperature Range | –10 to +105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| ATC Range | 0 to 100 °C |
| Calibration Options | 1-, 2-, or 3-point with auto-buffer recognition (Jenway, DIN, NIST, JIS standards) |
| Data Storage | Up to 32 measurement records |
| Interface | RS232 (DataWay compatible) |
| Power Supply | 9 V AC ±10%, 50/60 Hz |
| Dimensions (L×W×D) | 210 × 250 × 55 mm |
| Weight | 850 g |
| Brand | Jenway |
|---|---|
| Origin | United Kingdom |
| Model | 3540 |
| Instrument Type | Benchtop |
| Parameter Types | Dual (pH & Conductivity) |
| pH Range | -2.000 to 20.000 |
| pH Resolution | 0.001 / 0.01 / 0.1 |
| pH Accuracy | ±0.003 |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.2 mV |
| Conductivity Range | Auto-ranging from 0.01 µS to 1.999 S |
| Conductivity Resolution | 0.01 µS to 1 mS |
| Conductivity Accuracy | ±0.5% ±2 digits |
| Temperature Range | -10 to 105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| ATC Range | 0 to 100 °C |
| Temperature Coefficient | 0.00 to 4.00 %/°C |
| Reference Temperatures | 18, 20, 25 °C |
| Calibration Points | 1–3 point auto-calibration (pH), 1–3 point auto-calibration (conductivity) |
| Data Storage | 500 readings (250 per mode) |
| Interfaces | BNC (pH), 7-pin DIN (conductivity), RS232, IrDA, analog output |
| Power Supply | 9 V AC ±10%, 50/60 Hz |
| Dimensions (L×W×D) | 210 × 250 × 55 mm |
| Weight | 850 g |
| Brand | Jenway |
|---|---|
| Origin | United Kingdom |
| Model | 4510 |
| Form Factor | Benchtop |
| Conductivity Range | 0–1999 mS/cm (6 auto-ranging scales) |
| TDS Range | 0–1999 g/L |
| Temperature Range | –10 to 105 °C |
| Conductivity Accuracy | ±0.5% ±2 digits |
| TDS Accuracy | ±0.5% ±2 digits |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Conductivity Resolution | 0.01 µS/cm to 1 mS/cm |
| TDS Resolution | 0.01 mg/L to 1 g/L |
| Cell Constant Range | 0.010–19.999 cm⁻¹ |
| Temperature Coefficient | 0.00–4.00 %/°C |
| Reference Temperatures | 18 °C, 20 °C, or 25 °C |
| Auto Standard Recognition | 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm |
| Data Storage | 32 readings |
| Interface | RS232 (7-pin DIN), analog output |
| Power | 9 V AC ±10%, 50/60 Hz |
| Dimensions (L×W×D) | 210 × 250 × 55 mm |
| Weight | 850 g |
| Brand | Jenway |
|---|---|
| Origin | United Kingdom |
| Model | 4520 |
| Form Factor | Benchtop |
| Conductivity Range | 0 to 19.99 S |
| TDS Range | 0–1999 g/L |
| Resistivity Range | 0–20 MΩ·cm |
| Salinity Range | 0–99.9 g/L |
| Temperature Range | –10 to 105 °C |
| Accuracy | ±0.5% ±2 digits |
| Minimum Resolution | 0.01 µS (in low-range modes) |
| Calibration | 1-, 2-, or 3-point auto-recognized (10 µS, 84 µS, 1413 µS, 12.88 mS) |
| Cell Constant Support | 0.010–19.999 cm⁻¹ |
| GLP Compliance | Yes (calibration log, timestamped records, security codes) |
| Data Storage | 500 measurements with date/time stamp |
| Interfaces | RS232, IrDA, analog output |
| Power | 9 V AC adapter (230 V, 50/60 Hz) |
| Dimensions | 210 × 250 × 55 mm |
| Weight | 850 g |
| Brand | Jenway |
|---|---|
| Origin | France |
| Model | 570 |
| Instrument Type | Portable |
| Parameter Types | pH / mV / Temperature |
| pH Range | -2 to 16 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.02 |
| mV Range | -1000 to +1000 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±1 mV |
| Temperature Range | -39.9 to 149.9 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.4 °C (-10 to 70 °C) |
| Calibration Points | 2-point |
| Auto Buffer Recognition | Yes |
| ATC Range | 0 to 100 °C |
| IP Rating | IP66/IP67 |
| Auto Power-Off | 10 min |
| Battery Life | 2500 hours |
| Dimensions (L×W×D) | 141 × 71 × 32 mm |
| Weight | 230 g |
| pH Input | BNC |
| Temperature Input | Lumberg screw-lock connector |
| Brand | Jenway |
|---|---|
| Origin | United Kingdom |
| Model | 6850 |
| Optical Design | Double Beam |
| Detector Type | Silicon Photodiode |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm (at 0.5/1 nm SBW), ±0.5 nm (at 2/4/5 nm SBW) |
| Wavelength Repeatability | ±0.2 nm |
| Spectral Bandwidth | Variable (0.5, 1, 2, 4, 5 nm) |
| Stray Light | <0.05% T at 220 nm and 360 nm |
| Photometric Range | –0.3 to 3.0 A / 0 to 200% T |
| Photometric Accuracy | ±0.002 A (0–0.5 A), ±0.3% T (0–100% T) |
| Photometric Repeatability | ±0.001 A (0–0.5 A), ±0.002 A (0.5–1.0 A), ±0.15% T (0–100% T) |
| Noise | 0.0005 A |
| Baseline Stability | ±0.001 A/h at 500 nm after 15 min warm-up |
| Data Interfaces | USB, Parallel |
| Power Supply | 220/110 V, 50/60 Hz, 120 VA |
| Dimensions (W×D×H) | 600 × 450 × 200 mm |
| Weight | 22 kg |
| Brand | Jenway |
|---|---|
| Origin | United Kingdom |
| Model | 7410 |
| Wavelength Range | 320–1000 nm |
| Display | 7-inch full-color capacitive touchscreen |
| Sample Chamber | Light-tight dome design with large access lid |
| Standard Cuvette Holder | 10 × 10 mm (3 mL capacity) |
| Memory | 10 GB internal storage |
| Connectivity | Ethernet, dual USB-A ports |
| Software Platform | CPLive™ cloud-enabled suite |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Jenway |
|---|---|
| Origin | United Kingdom |
| Model | 7415 Nano |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Range | 198–1000 nm |