| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYJ-201SP2 |
| Principle | Colorimetric Method (Acetylacetone for Formaldehyde |
| Measurement Range | Formaldehyde: 0.0–125.0 mg/kg |
| Hexavalent Chromium | 0.0–50.0 mg/kg |
| Detection Limits | Formaldehyde: 5.0 mg/kg |
| Cr(VI) | 1.5 mg/kg |
| Accuracy | ±5% |
| Operating Temperature | 10–40 °C |
| Power Supply | 220 V, 50/60 Hz |
| Dimensions | 465 × 280 × 160 mm |
| Weight | 3.0 kg |
| Interface | USB |
| Integrated Thermal Printer | Yes |
| Prepackaged Sample Prep Kit | Yes |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYK-208SA |
| Price Range | USD 700–1,400 (FOB) |
| Measurement Principle | Colorimetric Method (Acetylacetone Derivatization) |
| Measurement Range | 0.00–1.00 mg/m³ (6 L air sample) |
| Detection Limit | 0.01 mg/m³ |
| Optical Source | High-Brightness LED |
| Wavelength | 635 nm |
| Accuracy | ±5% FS |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Rechargeable Battery | 7.4 V, 900 mAh |
| Brand | Jiada Xiaotianshe |
|---|---|
| Model | GDYK-301S |
| Type | Portable Gas Analyzer |
| Measurement Principle | Nessler’s Reagent Colorimetric Method (GB/T 18204.25–2000) |
| Detection Limit | 0.1 mg/m³ |
| Range | 0.0–5.0 mg/m³ |
| Accuracy | ±5% FS |
| Compliance | GB/T 18204.25–2000 |
| Sample Throughput | One analysis in ≤10 minutes |
| Kit Configuration | Integrated pre-treatment module + single-use reagent cartridges |
| Power Supply | Rechargeable Li-ion battery (≥8 h operation) |
| Operating Environment | 5–40 °C, RH ≤85% non-condensing |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYK-800M |
| Instrument Type | Portable |
| Measurement Principle | Spectrophotometry |
| Display | 12-inch multi-touch LCD |
| Connectivity | Ethernet, USB, Wi-Fi, 4G |
| Power Supply | AC/DC dual-mode |
| Light Source | High-brightness LED |
| Wavelengths | 630 nm (formaldehyde, TVOC), 430 nm (ammonia), 465 nm (benzene & homologues, TVOC) |
| Detection Limits | Formaldehyde 0.01 mg/m³, Ammonia 0.10 mg/m³, Benzene & Homologues 0.05 mg/m³, TVOC 0.05 mg/m³ |
| Measurement Ranges | Formaldehyde 0.00–2.00 mg/m³, Ammonia 0.00–5.00 mg/m³, Benzene & Homologues 0.00–1.00 mg/m³, TVOC 0.00–4.00 mg/m³ |
| Accuracy | ±5% |
| Sample Cell | 19 mm cylindrical glass cuvette and 50 mm rectangular glass cuvette |
| Operating Temperature | 5–40 °C |
| Built-in Thermal Printer | Yes |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYN-1016SD |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% inhibition rate |
| Number of Channels | 16 |
| Measurement Error | ±5% |
| Limit of Detection (LOD) | 0.01–3.0 mg/kg |
| Light Source | High-brightness LED |
| Wavelength | 405 nm |
| Optical Stability | ±0.005 A/20 min |
| Operating Temperature | 5–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz / Built-in Rechargeable Li-ion Battery |
| Data Storage | 32 GB internal + MicroSD expansion |
| Connectivity | Micro-USB, Micro-HDMI, Wi-Fi, GPRS/EDGE |
| OS | Embedded Windows-based interface |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GDYN-1024SC |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 24 |
| Measurement Error | ±6% |
| Limit of Detection (LOD) | 0.01–3.0 mg/kg |
| Light Source | Silicon Photodiode |
| Wavelength | 405 nm |
| Absorbance Range | 0.000–2.000 Abs |
| Inhibition Rate Range | 0–100% |
| Precision | ±6% |
| Detection Limit | 0.01–3.0 mg/kg |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDYN-1096SC |
| Detection Method | Enzyme Inhibition Assay |
| Number of Channels | 96 |
| Limit of Detection (LOD) | 0.01–3.0 mg/kg |
| Inhibition Range | 0–100% |
| Inhibition Accuracy | ±6% (at 50% inhibition) |
| Throughput | Up to 192 samples per hour |
| Data Storage Capacity | 1024 records |
| Interface | RS-232 / USB |
| Display | Full-Text LCD (Chinese) |
| Reagent Compatibility | Imported cholinesterase-based reagents (500-test kit included) |
| Optical Architecture | Solid-state array light source and detector per channel |
| Expected Service Life | >10 years |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYN-110SA |
| Detection Method | Enzyme Inhibition Assay |
| Number of Channels | 10 |
| Temperature Display Accuracy | ±0.5 °C |
| Colorimetric Timing Precision | ±1 s |
| Standard Reaction Time | 3 min |
| Input Voltage | 100–240 V AC |
| Rechargeable Battery Runtime | 100–150 min |
| Adjustable Incubation Time Range | 1–99 min |
| Operating Environment | Indoor & Vehicle-Mounted |
| Operating Temperature Range | 0–40 °C |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYN-501MA |
| Detection Method | Thin-layer Chromatography (TLC) |
| Measurement Range | Organophosphates: 0.03–20 mg/kg |
| Carbamates | 0.03–20 mg/kg |
| Pyrethroids | 0.10–30 mg/kg |
| Organochlorines | 0.10–10 mg/kg |
| Light Source | 254 nm UV lamp |
| Warm-up Time | ≤5 min |
| Irradiance | ≥1000 µW/cm² |
| Lamp Lifetime | ≥12,000 h |
| Wavelength Repeatability | ±1 nm |
| Wavelength Accuracy | ±5 nm |
| Filter Transmittance | ≥95% |
| Spot Spacing | 5–30 mm |
| Sample Volume | 2.5–15 µL |
| Spot Diameter | ≤2.0 mm |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 10–85% RH |
| Data Interface | USB 2.0 |
| Power Supply | 220 V ±22 V, 50 Hz ±1 Hz |
| Software Platform | Windows XP |
| Detection Modes | Transmission & Reflectance |
| Dimensions | 580 × 360 × 260 mm |
| Weight | 15.8 kg |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-1100M |
| Price Range | USD 1,400 – 7,200 |
| Detection Parameters | Moisture (0.0–27.0%), Fructose + Glucose (0.0–76.0%), Sucrose (0.0–12.0%), Acidity (0.0–100.0 mL/kg), Hydroxymethylfurfural (HMF) (0.0–100.0 mg/kg), Diastase Activity (0.0–25.0 mL/(g·h)) |
| LOD | Moisture: 12.0%, Fructose + Glucose: 13.0%, Sucrose: 3.0%, Acidity: 4.0 mL/kg, HMF: 1.0 mg/kg, Diastase Activity: 1.0 mL/(g·h) |
| Accuracy | ±2% |
| Interface | RS-232 / USB |
| Display | Backlit LCD with Chinese UI |
| Data Handling | Onboard storage, PC connectivity, statistical analysis |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-110SU |
| Function Type | Single-Analyte Quantitative Detection |
| Sample Type | Dedicated to Wheat Flour Matrix |
| Wavelength | 538 nm |
| Detection Limit | 5.0 mg/kg |
| Measurement Range | 5.0–100.0 mg/kg |
| Accuracy | ±5% |
| Light Source | High-Brightness LED |
| Power Supply | DC 9 V |
| Dimensions | 190 × 110 × 95 mm |
| Weight | 0.4 kg |
| Included | Sample Pretreatment Kit (1 set), Reagent Kit (50 assays) |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-1400S |
| Function Type | Single-Analyte Immunoassay Platform |
| Sample Versatility | Multi-sample Compatible (Liquid Food Matrices) |
| Wavelength Range | 400–700 nm |
| Throughput | 96-well plate in 5 seconds |
| Optical Resolution | 0.001 A (display), 0.0001 A (internal calculation) |
| Photometric Linearity | ±1% (0.000–2.000 A) |
| Absorbance Measurement Range | 0.0000–4.0000 A |
| Plate Formats | Standard 96-well and 48-well microplates |
| Filter Positions | Fixed 405 nm, 450 nm, 492 nm, 630 nm + 4 configurable slots |
| Detection Methodology | Single-, Dual-, and Multi-wavelength ELISA photometry |
| Data Processing Algorithms | Linear, Semi-log, 4PL, 5PL, Polynomial, Parabolic, Spline Curve Fitting |
| Plate Shaking | Adjustable speed and duration |
| Interface | RS232 serial port, parallel port |
| Power Supply | AC 220 V / 110 V ±22 V, 50 Hz / 60 Hz ±1 Hz |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-2000S |
| Detection Limit | 0.3 mmol/kg |
| Measurement Range | 0.0–11.0 mmol/kg |
| Accuracy | ±2% |
| Analysis Time | ≤5 min per sample |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded MCU with data logging, USB connectivity, and on-board statistical processing |
| Sample Prep | Integrated proprietary pre-treatment module + single-use reagent kits |
| Compliance | Modified GB/T 5009.37–2003 method |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-210SD |
| Function Type | Single-Analyte Detection System |
| Sample Compatibility | Multi-Matrix Food Samples |
| Detection Limit | 50.0 mg/kg |
| Quantification Range | 0.0–2000.0 mg/kg |
| Measurement Accuracy | ±5% (relative standard deviation under controlled conditions) |
| Control System | Embedded MCU-based platform |
| Data Interface | RS-232 and USB 2.0 |
| Display | Backlit LCD with Chinese UI |
| Portability | Handheld form factor, <1.2 kg |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Manufacture | Domestic (China) |
| Model | GDYQ-210SP |
| Price Range | USD 2,800–4,200 (FOB) |
| Functionality | Single-Analyte Quantitative Detection |
| Sample Compatibility | Multi-Sample Universal Design |
| Detection Range | 10.0%–50.0% (adulteration level) |
| Limit of Detection | 10.0% (adulteration level) |
| Power Supply | 220 V ±20 V, 50–60 Hz |
| Operating Ambient Temperature | 10–30 °C |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDYQ-500M |
| Price Range | USD 4,200 – 7,000 |
| Function Type | Multi-analyte Detection Platform |
| Sample Compatibility | Universal for Solid, Semi-solid, and Liquid Food Matrices |
| Detection Principles | UV-Vis Absorbance (Transmission/Reflection), Fluorescence Spectrometry |
| Wavelength Accuracy | ±5 nm |
| Wavelength Repeatability | ±1 nm |
| Detection Modes | Transmission, Reflectance, Fluorescence |
| Quantification Method | External Standard Calibration |
| Regulatory Compliance | GB/T 5009.28–2003, GB/T 5009.29–2003, GB/T 5009.35–2003, GB/T 5009.141–2003, GB 2760–2011 |
| Software | Dedicated PC-based Workstation with Chromatogram-like Peak Visualization, Automatic Integration, and Audit-Trail-Ready Data Export |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | GDYQ-6000S |
| Function Type | Single-Analyte Quantitative Detection |
| Sample Versatility | Multi-Sample Compatible |
| Optical Detection Wavelength | 400 nm |
| Detection Channels | 1 |
| Lower Detection Limit | 10.0 mg/kg |
| Quantification Range | 0.0–1000.0 mg/kg |
| Measurement Accuracy | ±2% |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (PRC) |
| Model | GDYQ-900M |
| Price Range | USD 7,000–14,000 (FOB) |
| Functionality | Multi-analyte (simultaneous detection of >20 food safety parameters) |
| Sample Versatility | Universal for solid, liquid, and semi-solid food matrices |
| Optical Detection Range | 495–530 nm |
| Repeatability | ≤ ±5% CV or ±5 RLUs |
| Detection Channels | 16 independent optical/analytical channels |
| Power Supply | AC/DC dual-mode |
| Display | 10.1" capacitive touchscreen, 1024 × 768 resolution |
| Data Storage | Internal SSD (≥64 GB) |
| Connectivity | Wi-Fi 802.11 b/g/n, Ethernet (RJ45), USB 2.0 × 2 |
| Output | Integrated thermal printer + external printer support via USB/Ethernet |
| Operating System | Windows Embedded Standard 7 |
| Software | Proprietary modular detection platform with remote OTA and local USB firmware update capability |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | GDYQ-901SC2 |
| Function Type | Single-Analyte Detection |
| Sample Versatility | Multi-Sample Compatible |
| Optical Wavelength | 538 nm |
| Detection Channels | 1 |
| Detection Limit | 2.0 mg/kg |
| Measurement Range | 0.0–200.0 mg/kg |
| Accuracy | ±2% |
| Regulatory Method | Modified GB/T 5009.33–2003 |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-RS1101 |
| Function Type | Single-parameter Moisture Determination |
| Sample Scope | Multi-sample Universal (Fresh Mammalian & Poultry Muscle Tissue) |
| Measurement Range | 65–85% w/w |
| Sampling Time | <1 s per acquisition |
| Output Interval | One result per 10 acquisitions or per single acquisition (configurable) |
| Accuracy (70–80% range) | ±1.0% w/w |
| Repeatability (70–80% range) | ≤0.5% w/w |
| Operating Temperature | 0–40 °C |
| Power Alert | Yes |
| Auto-shutdown | Yes |
| Data Storage | Onboard memory with total count display and recall |
| PC Connectivity | USB interface for data export and post-processing |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYS-101SM2 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Analyte | Manganese |
| Detection Limit | 0.50 mg/L |
| Measurement Range | 0.00–4.00 mg/L |
| Accuracy | ±5% |
| Compliance Standard | GB/T 5750.6–2006 |
| Analysis Time | ≤10 minutes per sample |
| Reagent Format | Single-use proprietary test kit |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Model | GDYS-101SN4 |
| Measurement Principle | Colorimetric Method (DPD-based) |
| Measured Parameters | Residual Chlorine, Total Chlorine |
| Range | Residual Chlorine: 0.00–2.50 mg/L |
| Total Chlorine | 0.00–2.50 mg/L |
| Accuracy | ±5% of reading |
| Detection Limit | 0.01 mg/L for both residual and total chlorine |
| Light Source | High-brightness LED |
| Wavelength | 520 nm |
| Power Supply | DC 9 V |
| Dimensions | 190 × 110 × 95 mm |
| Weight | 0.4 kg |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Measurement Principle | Potassium Dichromate Digestion Method (On-site Compatible) |
| Wavelengths | 410 nm and 630 nm |
| Measurement Ranges | Range 1: 0–100 mg/L |
| Range 2 | 50–1000 mg/L |
| Range 3 | 500–3000 mg/L |
| Accuracy | ±5% |
| Detection Limit | 4 mg/L |
| Light Source | High-Brightness LED |
| Power Supply | DC 9 V |
| Dimensions | 200 × 105 × 95 mm |
| Weight | 0.4 kg |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYS-101SR |
| Pricing | Available Upon Request |
| Detection Method | DL Colorimetric Method |
| Detection Time | 3 minutes |
| Lower Detection Limit | 0.1 mg/L |
| Measurement Range | 0.0–10.0 mg/L |
| Accuracy | ±5% |
| Reagent Format | Single-use dedicated reagent kit |
| Sample Types | Distilled water, drinking water, domestic water, aquaculture water, seawater, surface water, wastewater |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYS-101SV |
| Pricing | Available Upon Request |
| Detection Limit | 0.02 mg/L |
| Measurement Range | 0.00–1.00 mg/L |
| Accuracy | ±5% |
| Compliance | GB/T 5750.5–2006 |
| Analysis Time | ≤10 minutes per sample |
| Reagent Format | Single-use, pre-packaged test kits |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYS-101SX3 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measured Parameter | Nitrite-Nitrogen (NO₂⁻-N) |
| Detection Limit | 0.001 mg/L |
| Measurement Range | 0.000–0.100 mg/L |
| Accuracy | ±5% |
| Compliance | GB/T 5750.5–2006 |
| Display | LCD with Microcontroller Control |
| Design | Compact, Lightweight, Field-Deployable |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYS-101SZ2 |
| Pricing | Available Upon Request |
| Detection Limit | 0.5 NTU |
| Measurement Range | 0.0–60.0 NTU |
| Accuracy | ±5% of reading |
| Compliance | GB/T 5750.4–2006 |
| Analysis Time | ≤3 minutes per sample |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYS-102SL |
| Pricing | Upon Request |
| Detection Limit | 20.0 mg/L |
| Measurement Range | 0.0–500.0 mg/L |
| Accuracy | ±5% |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Volatile Phenol Analyzer |
| Model | GDYS-103SK |
| Detection Limit | 0.1 mg/L |
| Measurement Range | 0.0–5.0 mg/L |
| Accuracy | ±5% |
| Analysis Time | ≤10 minutes |
| Reagent Format | Single-use, pre-packaged test kit |
| Compliance | Designed for field-deployable water quality screening per standard colorimetric phenol detection protocols |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GDYS-201M (65 Parameters) |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Detection Capabilities | 65 Quantitative Parameters Including Free Chlorine, Fluoride, Iron, Chloride, etc. |
| Measurement Time | 5–30 Minutes per Parameter |
| Display | Large Backlit LCD with Chinese Interface |
| Control System | Embedded Microcontroller with Interactive GUI |
| Data Functions | Real-time Measurement, Parameter Configuration, Onboard Storage, Statistical Analysis, USB Export |
| Compliance | Designed to Align with GB/T Standards (China National Standards) for Environmental Water Testing |