KPM AMS
Filter
Showing all 6 results
| Brand | KPM AMS |
|---|---|
| Origin | USA |
| Model | iCinac |
| Detection Parameters | pH, Temperature, Redox Potential (mV) |
| Channel Capacity | Up to 96 simultaneous channels (configurable as 16-, 32-, or 96-channel systems) |
| Automation Level | Semi-automatic with modular control outputs (up to 32 configurable digital/analog outputs) |
| Compliance | Fully compliant with ISO 26323:2021 — “Dairy products — Method for monitoring acidification behaviour by continuous pH measurement” |
| Sensor Technology | Digital multi-parameter ISM®-enabled electrodes (pH + temperature + redox in single probe per channel) |
| Software Platform | Integrated Windows®-compatible touchscreen interface with real-time data acquisition, automatic feature-point calculation, and GLP-compliant audit trail |
| Brand | KPM AMS |
|---|---|
| Origin | USA |
| Model | SmartChem 140 |
| Product Type | Discrete Chemistry Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | ≥50 positions |
| Reagent Positions | ≥20 |
| Cuvette Path Length | 6 mm |
| Light Source | Tungsten-halogen lamp (6 V / 10 W, 2000 h lifetime) |
| Absorbance Range | 0–3.5 OD |
| Resolution | 0.0001 Abs |
| Optical System | Dual-beam with 9-position filter wheel + blind position |
| Detection | Silicon photodiode |
| Analysis Speed | Up to 140 samples/hour |
| Sample Volume | 3–450 µL |
| Reagent Consumption per Test | ~300 µL |
| Sample Tube Dimensions | 16 mm × 100 mm (diameter × height) |
| Automatic Dilution | Yes |
| Standard Preparation | Automated serial dilution from single stock standard |
| Blank Correction | True sample blank subtraction |
| Calibration | Up to 6th-order polynomial regression |
| Data Output | Raw absorbance-time profiles with reprocessing capability |
| Compliance | ISO, AOAC, APHA, USEPA, AFNOR, COFRAC, BATF methods |
| Brand | KPM AMS |
|---|---|
| Origin | USA |
| Model | SmartChem 200 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Parameters | Nitrate, Nitrite, Ammonia-N, Phosphate, Sulfide, Cyanide, Volatile Phenols, Total Phosphorus, Total Nitrogen, Urea, Silicate, Sulfate, Borate, Formaldehyde, Chlorine, Chloride, Fluoride, Hexavalent Chromium, Copper, Aluminum, Iron, pH, Hardness, Conductivity, Volatile Acids |
| Sample Capacity | 126 positions per run |
| Reagent Positions | 16 |
| Optical Path Length | 10 mm |
| Minimum Reaction Volume | 180 µL |
| Temperature Control Range | Ambient to 45 °C (±0.1 °C) |
| Absorbance Range | 0–2.500 Abs |
| Detection Sensitivity | 0.0001 Abs |
| Filter Wheel | 12-position (340–880 nm), 9 filters + blind position |
| Measurement Modes | Endpoint, Fixed-Time, Kinetic, Differential-Time, Dual-Beam |
| Compliance | ASTM, ISO, AOAC, OIV, US EPA Method 353.2, AFNOR, COFRAC, BATF |
| Brand | KPM AMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | SmartChem 450 |
| Sample Capacity | 100 positions |
| Reagent Positions | 72 |
| Optical Path Length | 10 mm |
| Wavelength Range | 340–1100 nm |
| Light Source | Tungsten-Halogen and Deuterium (Dual) Photometric Source |
| Detection Resolution | 0.0001 Abs |
| Minimum Reaction Volume | 200 µL |
| Throughput | Up to 450 samples/hour |
| Filtration | 9-position motorized filter wheel |
| Compliance | ISO/IEC 17025, US EPA Methods (e.g., 353.2, 365.4), AOAC, OIV, AFNOR, COFRAC, BATF |
| Brand | KPM-AMS |
|---|---|
| Origin | USA |
| Model | Futura II |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340 nm – 1100 nm |
| Sample Capacity | 240 positions |
| Reagent Positions | 20 |
| Flow Cell Path Length | 10 mm – 5 m |
| Light Source | Photometric Lamp |
| Brand | KPM-AMS |
|---|---|
| Origin | USA |
| Model | Futura III |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–110 nm |
| Sample Capacity | ≥240 positions |
| Reagent Positions | 20 |
| Flow Cell Path Length | 10 mm to 5 m |
| Light Source | Photometric light source |