Malvern PANalytical
Filter
Showing 31–51 of 51 results
| Brand | Malvern Panalytical |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Omega/Theta |
| Instrument Type | Single-Crystal X-ray Diffractometer |
| Orientation Accuracy (1σ) | <0.003° (rocking angle), <0.03° (in-plane direction) |
| Measurement Time | ≤10 s per orientation determination |
| Maximum Sample Weight | 30 kg |
| Maximum Sample Length | 450 mm |
| Goniometer Configuration | Omega/Theta (θ–2θ coupled or independent scanning) |
| Brand | Malvern PANalytical |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Revontium |
| Form Factor | Benchtop/Floor-standing |
| Instrument Type | Conventional ED-XRF |
| Application Scope | General-purpose |
| Elemental Range | Na to Am (Z = 11 to Z = 95) |
| Energy Resolution | <145 eV at Mn Kα |
| Detectors | Four simultaneous silicon drift detectors (SDDs) |
| Brand | Malvern Panalytical |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | SDCOM |
| Instrument Type | Single-Crystal X-ray Diffractometer |
| X-ray Source | 30 W air-cooled Cu-anode microfocus X-ray tube |
| Measurement Speed | Full orientation determination in ≤10 s per sample rotation |
| Sample Diameter Range | 1–200 mm |
| Angular Precision (Si 100) | Tilt magnitude < 0.01°, tilt direction < 0.03° |
| Uptime | >99% |
| Theta Scan Capability | Yes |
| Multi-crystal Transfer | Up to 6 oriented crystals per collimated beam |
| MES Integration | Compatible with SECS/GEM-compliant manufacturing execution systems |
| Brand | Malvern Panalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Spraytec |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.5 µm @ 150 mm path length |
| Repeatability | Dv50 better than ±1% COV (NIST-traceable latex standards) |
| Measurement Duration | Fast Mode: 30 seconds |
| Continuous Mode | up to 60 minutes |
| Brand | Malvern Panalytical |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Wafer XRD |
| Instrument Type | Single-Crystal X-ray Diffractometer |
| Sample Size Compatibility | 3-inch to 8-inch wafers (custom FOUPs, carriers, or single-wafer stages available) |
| Measurement Speed | <10 seconds per wafer |
| Typical Standard Deviation (Tilt Angle) | <0.003° for Si(100) |
| X-ray Source Options | Air-cooled microfocus Cu-target tube (30 W) or water-cooled fine-focus Cu-target tube (1.5 kW) |
| Safety Compliance | Fully CE-compliant with integrated interlock and three-color tower light status indication |
| Interface Protocols | SEMI-compliant MES and SECS/GEM |
| Optional Modules | Resistivity measurement (0.01–0.020 Ω·cm), automated matrix/QR/barcode recognition, unpolished & mirror-surface distance metrology |
| Material Support | Si, SiC, GaAs, GaN, Sapphire (Al₂O₃), Ge, AlN, Quartz, InP, and >100 additional crystalline semiconductor substrates |
| Brand | Malvern PANalytical |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | WAVEdelta |
| Instrument Principle | Grating-Coupled Interferometry (GCI) |
| Channel Configuration | Multi-channel |
| Detection Range | pM to mM |
| Sample Format Support | Dual microplate carriers (96-well or 384-well, standard or deep-well) or 48-position 1.5 mL vial rack |
| Injection Volume | < 450 µL (typical: 100 µL) |
| Assay Duration | 0–120 h |
| Temperature Control Range | 4 °C – 45 °C |
| Brand | Malvern PANalytical |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | X’Pert3 MRD (XL) |
| Instrument Type | Powder X-ray Diffractometer |
| Power Supply | Not Specified |
| Brand | Malvern Panalytical |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Crystal Orientation |
| Instrument Type | Single-Crystal X-ray Diffractometer |
| Orientation Speed | ≤10 s per measurement |
| Angular Accuracy | ±0.003° (Wafer XRD 200/300), ±0.01° (DDCOM/SDCOM) |
| Sample Diameter Range | 1–225 mm |
| Cooling Requirement | Air-cooled (no water cooling required) |
| Compliance | ASTM E975, ISO 18755, IEC 61000-6-3, CE, RoHS |
| Interface Options | Ethernet/IP, Profibus, Modbus TCP, SECS/GEM |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Options | Blue Label and Red Label configurations |
| Particle Size Range | 0.3 nm – 15 µm |
| Size Measurement Repeatability | ±2% |
| Temperature Control Range | 10–35 °C |
| Temperature Stability | ±0.1 °C |
| Detection Angle | 90° (Classical Dynamic Light Scattering) |
| Minimum Sample Volume | 3 µL |
| Sample Concentration Range | 0.1 mg/mL – 40% w/v |
| Zeta Potential Range | No practical lower or upper limit |
| Typical Measurement Time | 3–5 minutes per analysis |
| Molecular Weight Range | 980 Da – 20 MDa |
| Brand | Malvern Panalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Options | Blue Label and Red Label configurations |
| Particle Size Range | 0.3 nm – 10 µm |
| Size Measurement Repeatability | ±2% |
| Temperature Control Range | 10–35 °C |
| Temperature Stability | ±0.1 °C |
| Detection Principle | Non-Invasive Back Scatter (NIBS) Dynamic Light Scattering (DLS) |
| Minimum Sample Volume | 12 µL |
| Sample Concentration Range | 0.1 mg/mL – 40% w/v |
| Zeta Potential Range | No practical lower or upper limit under standard operational conditions |
| Typical Measurement Time | 3–5 minutes per analysis |
| Molecular Weight Range | 980 Da – 20 MDa |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Variants | Blue Label and Red Label |
| Particle Size Range | 0.3 nm – 15 µm |
| Size Measurement Repeatability | ±2% |
| Temperature Control Range | 10–35 °C |
| Temperature Stability | ±0.1 °C |
| Detection Method | Non-Invasive Back Scatter (NIBS) DLS and Multi-Angle Dynamic Light Scattering (MADLS®) |
| Minimum Sample Volume | 3 µL |
| Sample Concentration Range | 0.1 mg/mL – 40% w/v |
| Zeta Potential Range | No practical lower or upper limit |
| Typical Measurement Time | 3–5 minutes |
| Molecular Weight Range | 980 Da – 20 MDa |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Model | Blue Label and Red Label variants |
| Particle Size Range | 0.3 nm – 15 µm |
| Size Reproducibility | ±2% |
| Temperature Control Range | 10–35 °C |
| Temperature Stability | ±0.1 °C |
| Zeta Potential Range | No effective limit |
| Measurement Time | 3–5 min |
| Molecular Weight Range | 980 Da – 20 MDa |
| Concentration Range | 0.1 mg/mL – 40% w/v |
| Minimum Sample Volume | 3 µL |
| Particle Sizing Method | Non-Invasive Back Scatter (NIBS) DLS and Multi-Angle Dynamic Light Scattering (MADLS®) |
| Zeta Potential Method | M3-PALS (Phase Analysis Light Scattering) with Constant Current Mode |
| Software Compliance | FDA 21 CFR Part 11, GLP/GMP-ready audit trail |
| Optional Accessories | MPT-3 Auto-Titrator, Polarization/Fluorescence Filter Wheel, Disposable Capillary Cells |
| Brand | Malvern Panalytical |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Zetium |
| Instrument Type | Floor-standing |
| X-ray Tube Power | 2.4–4 kW |
| Elemental Range | 4Be to 95Am |
| Instrument Class | Scanning-type WDXRF |
| Brand | Malvern Panalytical |
|---|---|
| Origin | Netherlands |
| Instrument Type | Floor-standing |
| Excitation Source | High-power X-ray tube (2.4–4 kW) |
| Analytical Range | Be (4) to Am (95) |
| Configuration | Scanning-type WDXRF with integrated EDXRF core (SumXcore technology) |
| Software Platform | SuperQ with Virtual Analyst |
| Compliance | Designed for ISO/IEC 17025, ASTM E1621, ASTM E2488, USP <233>, and GLP/GMP environments requiring audit trail and electronic signature support (21 CFR Part 11 ready) |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer | Micromeritics Instrument Corp. |
| Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static and Dynamic Gas Sorption |
| Number of Analysis Stations | 3 |
| Micropore Range | < 2 nm |
| Steam Adsorption Capability | Standard |
| Chemisorption Options | Static, Dynamic (TPR/TPO/TPD/TPSR), Pulse |
| Temperature Control Range | Up to 1100 °C (±1 °C) |
| Pressure Sensing | Ultra-low-range 0.1 Torr sensor for micropore analysis |
| Vacuum Performance | Metal-sealed manifold with ultra-low outgassing rate |
| Software | MicroActive™ Data Reduction Suite |
| Compliance | ASTM D3663, ISO 9277, ISO 15901, USP <846>, IUPAC Recommendations |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer | Micromeritics Instrument Corporation |
| Model | AccuPyc III 1350 |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop Laboratory System |
| Sample Type | Solid Materials |
| Density Range | 0.1–100 cm³ (sample volume) |
| Density Accuracy | ±0.02% |
| Temperature Control Range | 4 °C to 60 °C, stability ±0.025 °C |
| Repeatability | ±0.01% |
| Minimum Sample Volume | 0.1 cm³ |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer | Micromeritics Instrument Corp. |
| Model | ASAP 2460 Series |
| Analysis Stations | 2–6 (modular expansion) |
| Measurement Principle | Static gas adsorption (volumetric method) |
| Pore Size Range | 0.35–500 nm |
| Pressure Range | 0–1000 mmHg (absolute) |
| Theoretical Basis | BET, t-plot, Langmuir, DFT, NLDFT, BJH, HK, SF |
| Optional Configurations | Low-surface-area (Kr adsorption, 10 mmHg transducer) and micropore (1 mmHg transducer, N₂/Ar/CO₂/H₂ capability) |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer | Micromeritics Instrument Corp. |
| Model | AutoChem III |
| Gas Inlet Ports | 18 |
| Temperature Range | Ambient to 1200 °C |
| Ramp Rate | Up to 100 °C/min from –100 °C to 800 °C |
| Core Functions | Pulse Chemisorption, Temperature-Programmed Reduction (TPR), Single-Point BET Surface Area Analysis |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready software architecture |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer | Micromeritics Instrument Corp. |
| Model | Micromeritics ChemiSorb Auto |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Flow Method |
| Number of Gas Inlets | 8 (4 Carrier + 4 Loop) |
| Maximum Heating Temperature | 1000 °C |
| Programmable Heating Rate | 1–50 °C/min (with CryoCooler option enabling -100 °C to 1000 °C range) |
| Supported Techniques | Temperature-Programmed Reduction (TPR), Temperature-Programmed Oxidation (TPO), Temperature-Programmed Desorption (TPD), Pulse Chemisorption, TPSR, Strong Metal-Support Interaction (SMSI) analysis, Acid Site Strength Distribution (Lewis/Brønsted), BET Surface Area |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer | Micromeritics Instrument Corporation |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Number of Analysis Stations | 1–3 |
| Gas Options | N₂, Kr, Ar, CO₂, CH₄, C₄H₁₀ (non-corrosive) |
| Minimum Surface Area (N₂) | 0.01 m²/g |
| Minimum Surface Area (Kr) | 0.001 m²/g |
| Minimum Pore Volume | 4 × 10⁻⁶ cm³/g |
| Dewar Capacity | 2.75 L (optional 4 L) |
| Continuous Analysis Duration | up to 40 h |
| Data Points per Isotherm | up to 1000 |
| P₀ Measurement | integrated, continuous or manual input |
| Free Space Determination | measured, calculated, or user-defined |
| Brand | Malvern Panalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Zetasizer Sample Assistant |
| Pricing | Available Upon Request |