METTLER TOLEDO
Filter
Showing 331–360 of 403 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA2 |
| Temperature Range | RT to 1100 °C |
| Balance Sensitivity | 0.1 µg / 1 µg (depending on balance module) |
| Heating/Cooling Rate | 0.02 to 150 K/min |
| Temperature Accuracy | ±1 K |
| Blank Curve Repeatability | < ±10 µg across full temperature range |
| Sensor Type | Single-pan SDTA (Simultaneous Differential Thermal Analysis) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA2 |
| Temperature Range | 30 °C – 1,100 °C |
| Sampling Rate | 10 data points/second |
| Atmosphere Control | Integrated Mass Flow Controller (MFC) for programmable gas switching |
| Buoyancy Correction | Automatic, model-based, no blank required |
| One-Click Method Launch | Yes |
| Optional Couplings | FTIR, MS, Micro GC, GC/MS |
| Sensor Output | Mass & Temperature |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Product Type | Technical Reference Handbook |
| Model | Thermal Analysis Application Handbook – Evolved Gas Analysis |
| Compliance | Compatible with TGA-FTIR and TGA-MS coupling configurations per ISO 11358, ASTM E1131, and USP <1031> guidelines |
| Format | Printed and digital PDF (English edition) |
| Intended Use | Method development & interpretation support for thermal decomposition gas-phase characterization |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Distribution Type | Authorized Distributor |
| Product Category | Thermal Analyzer Accessory / Reference Publication |
| Model | Thermal Analysis Application Handbook Series – Thermoplastic Polymers |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Thermal Analysis Application Handbook Series – Thermosetting Resins |
| Price | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Product Type | Technical Reference Handbook |
| Model | Thermal Analysis Applications Handbook – Elastomers |
| Language | English |
| Format | Printed Book + Digital PDF (upon request) |
| Compliance | Aligned with ISO 11357, ISO 11358, ASTM D3418, ASTM E1356, USP <1159> |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | 2300Na |
| Measurement Range | 0.001–100,000 ppb Na⁺ |
| Calibration | Unattended 3-point incremental or manual 1-/2-point |
| Dimensions | 900 × 450 × 190 mm |
| Analog Outputs | (4) 0/4–20 mA |
| Electrode Activation | Automatic during calibration |
| Enclosure Options | Fully enclosed locked cabinet or semi-enclosed with service door |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | 2800Si |
| Detection Limit | 0.8 ppb |
| Measurement Range | 0–5000 ppb |
| Accuracy | ±5% of reading or ±1 ppb (whichever is greater) |
| Cycle Time | Adjustable, typically 20 minutes |
| Maximum Sample Pressure | <7 bar (100 psig) |
| Compliance | Designed for ASTM D4582, ASTM D5116, ISO 14687-2, and power plant water chemistry guidelines per EPRI TR-102328 & IAPWS RP-7 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | 4000TOCe |
| Instrument Type | Online TOC Analyzer |
| Measurement Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photolysis (185 nm) |
| Measurement Range | 0.05–1000 ppb C |
| Accuracy | ±0.1 ppb (TOC < 2 ppb) |
| Resolution | 0.001 ppb |
| Detection Limit | 0.025 ppb |
| Repeatability | ±0.05 ppb (<5 ppb) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | 450TOC |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Measurement |
| Oxidation Method | UV Photolysis (185 nm) |
| Measurement Range | 0.05 – 1000 ppb C (μg C/L) |
| Accuracy | ±0.1 ppb C for TOC < 2.0 ppb |
| Resolution | 0.001 ppb C (μg C/L) |
| Detection Limit | 0.025 ppb C |
| Repeatability | ±0.05 ppb C (< 5 ppb), ±1.0% (> 5 ppb) |
| Sample Temperature | 0–70 °C |
| Particle Size Limit | < 100 µm |
| Conductivity Requirement | ≥0.5 MΩ·cm (≤2 µS/cm) |
| pH Limit | < 7.5 |
| Flow Rate | 20 mL/min |
| Inlet Pressure | 4–85 psig (0.3–5.8 bar) |
| Dimensions | 334 × 185 × 324 mm |
| Weight (with base) | 7.0 kg |
| Enclosure Material | UL 94 V-0 Flame-Retardant Polystyrene |
| Wetted Materials | 316 Stainless Steel, Quartz, PEEK, Titanium, PTFE, Silicone, FFKM, EPDM |
| Environmental Operating Range | 5–50 °C / 5–80% RH (non-condensing) |
| Power | 100–240 VAC, 50/60 Hz, max. 40 W |
| Certifications | CE, cULus |
| Traceability | NIST-traceable conductivity & temperature sensors per ASTM D1125 and D5391 |
| Compliance | ASTM D5173, USP <643>, EP 2.2.44, JP 2.59, ChP 0912 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | 770MAX |
| Input Channels | 6 (up to 16 measured parameters) |
| Sensor Types Supported | 8 (e.g., conductivity/resistivity, pH/ORP, dissolved oxygen, ozone, TOC, flow, temperature, pressure, level) |
| Output Options | 4 or 8 × 0/4–20 mA analog outputs |
| Communication | RS232 serial interface |
| Relay Outputs | 4 (optional) |
| Display | Multi-line scrolling LCD with customizable parameter naming |
| Power Supply | Universal 100–240 VAC, 50–60 Hz |
| Enclosure | 1/4 DIN, IP65-rated with sealed rear cover |
| Calibration Support | NIST-traceable verification via optional 1875 Smart Calibrator |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | 770MAX |
| Input Channels | 6 (up to 16 measurement results) |
| Sensor Types Supported | 8 (including pH/ORP, conductivity/resistivity, dissolved oxygen, ozone, TOC, flow, temperature, pressure, level) |
| Output Options | 4 or 8 analog outputs (0/4–20 mA), RS232 serial interface, up to 4 relay outputs (optional) |
| Display | Multi-line scrolling LCD with customizable parameter labeling |
| Power Supply | Universal AC 100–240 V, 50–60 Hz |
| Enclosure | 1/4 DIN, IP65-rated front panel, sealed rear cover |
| Calibration | NIST-traceable verification & calibration via optional 1875 Smart Calibrator |
| Smart Sensor Compatibility | Thornton intelligent sensors with embedded NVRAM for auto-recognition, calibration data storage, and plug-and-play operation |
| Measurement Units | 35 configurable units across parameters |
| Temperature Compensation | Integrated, parameter-specific algorithms |
| Data Timestamping | Internal real-time clock for all measurements and calibration events |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | InPro7250 Series |
| Sensor Principle | Toroidal (Electrodeless) Induction |
| Measurement Parameters | Conductivity, Resistivity, Salinity (TDS-derived), Temperature |
| Output Protocols | HART, PROFIBUS PA, FOUNDATION Fieldbus |
| Enclosure Rating | IP66/IP67, ATEX/IECEx Certified Options Available |
| Channel Configuration | Single- or Dual-Channel Transmitter Options |
| Compliance | FDA 21 CFR Part 11 (with ISM software), ASTM D1125, ISO 7888, USP <645>, EP 2.2.38 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TMA/SDTA 2+ IC/600 / LF/1100 / LN/600 |
| Temperature Range | –80 to 600 °C |
| Temperature Accuracy | ±0.005 °C |
| Force Range | –0.1 to 1 N |
| Displacement Resolution | 0.5 nm |
| Frequency Range | 0.01–1 Hz |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | LF/1100, HT/1600, IC600, LN600 |
| Temperature Range | –150 °C to 1600 °C |
| Temperature Accuracy | ±0.005 °C |
| Force Resolution | 0.01–1 Hz (dynamic frequency range) |
| Displacement Range | 20 mm |
| Length Resolution | 0.5 nm |
| Operating Modes | Compression, Tension, Penetration, Expansion |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TMA/SDTA840, TMA/SDTA841e |
| Temperature Range | −150–600 °C (TMA/SDTA841e), RT–1100 °C (TMA/SDTA840) |
| Temperature Accuracy | ±0.25 °C |
| TMA Resolution | 1 nm (TMA/SDTA841e), 10 nm (TMA/SDTA840) |
| Measurement Modes | Expansion, Penetration, Bending, Tension, Dynamic Load TMA (DLTMA) |
| SDTA Capability | Yes |
| Environmental Control | Hermetic sample chamber |
| Coupling Options | MS, FTIR |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TOPEM™ TMDSC |
| Category | Imported Instrument |
| Distributor Type | Authorized General Distributor |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TT DMA |
| Temperature Range | −190 °C to 600 °C |
| Frequency Range | 0.001 Hz to 1000 Hz |
| Fixture Configurations | Dual-cantilever, single-cantilever, 3-point bending, shear, tension, compression |
| Operating Modes | Creep, constant-force (TMA), stress–strain, stress relaxation, isothermal, step-isothermal, multi-ramp thermal profiles |
| Environmental Options | Humidity chamber (up to 85 °C / 85 % RH), liquid immersion cell, gas purge (N₂, air, Ar) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Laboratory Service |
| Service Model | Customized Training & Process Consulting |
| Training Experience | 10+ Years |
| Equipment Scope | Laboratory Weighing, In-line Process Analytics, Calibration & Metrology Systems |
| Pricing | Upon Consultation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | UV-DSC1 |
| Temperature Range | −150 to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating Rate | 0.02–300 °C/min |
| Heat Flow Sensitivity | 0.04 µW (FRS5 sensor) / 0.01 µW (HSS8 sensor) |
| UV Wavelength Range | 240–400 nm (optional extension to 400–700 nm, visible) |
| UV Irradiance | 4500 mW/cm² (at 365 nm) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | UV5, UV7 |
| Optical Design | Single-beam with pulsed xenon lamp |
| Detector | 2048-pixel CCD array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1.0 nm (UV5), ±0.8 nm (UV7) |
| Stray Light | <0.01% T at 198 nm (KCl) |
| Scan Speed | Full spectrum in ≤1 s |
| Photometric Accuracy | ±0.01 A (K₂Cr₂O₇) |
| Wavelength Resolution (toluene in n-hexane) | >1.5 nm (UV5), >1.9 nm (UV7) |
| Display | 7″ QVGA color TFT touchscreen (400 × 800 px) |
| Dimensions (L×W×H, without controller) | 208 × 255 × 228 mm |
| Weight (with controller) | 6.4 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | UV5 / UV7 / UV5Bio |
| Detector Type | CCD (Charge-Coupled Device) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.9 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | <0.03% T (at 220 nm, KI solution) |
| Automation Level | Automatic Wavelength Selection |
| Lamp Type | Xenon Flash Lamp |
| Warm-up Time | None |
| Dimensions | Compact footprint (~A4 size) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | UV5Bio / UV5Nano |
| Optical Design | Dual-wavelength |
| Detector | CCD array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Stray Light (at 198 nm, KCl) | >2.0 A |
| Scan Time (full spectrum) | 1 s |
| Automation | Automatic wavelength selection, integrated cuvette changer, FillPalMini peristaltic pump |
| Compliance | ASTM E275, ISO 6425, USP <857>, FDA 21 CFR Part 11 ready (via LabX®) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | UV5Nano |
| Detector Type | CCD (Charge-Coupled Device) |
| Wavelength Range | 190 nm – 1,100 nm |
| Wavelength Automation | Automatic |
| Spectral Bandwidth | 1.5 nm |
| Wavelength Accuracy | ±0.9 nm |
| Stray Light | <0.03% T (at 220 nm, KI solution) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | V20S |
| Titration Method | Volumetric Karl Fischer |
| Display | 7-inch full-color capacitive touchscreen |
| User Interface Languages | Chinese, English, German, French, Spanish, Italian, Russian, Polish, Korean, Portuguese |
| Connectivity | USB, Ethernet (TCP/IP), LabX PC software compatible |
| Preloaded Methods | Up to 5 user-defined methods |
| Customizable One Click™ shortcuts | Up to 12 per user |
| Compliance | Designed for ISO/IEC 17025, ASTM E203, USP <921>, EP 2.5.12, and FDA 21 CFR Part 11-ready environments (when used with LabX) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Titration Mode | Fully Automated |
| Measurement Resolution | 0.1 mV |
| Water Content Range | 10 ppm to 100% (w/w) |
| Accuracy | ±0.3% (for samples containing >10 mg H₂O) |
| Minimum Dispensing Volume | 0.05 µL |
| Titration Drive Precision | 20,000 steps per revolution |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automated |
| Moisture Range | 10 ppm to 100% |
| Resolution | 0.1 µL (burette resolution) |
| One-Click Method Shortcuts | 12 (V20S), 4 (V30S), 12 (C10S), 12 (C20S), 12 (C30S) |
| Solvent Manager | Hardware-integrated, hot-pluggable |
| Smart Burette | RFID-enabled, auto-recognized |
| User Management | 4-level permission system with password protection |
| Software Integration | LabX Express / LabX Server via USB or TCP/IP |
| GLP-Compliant Printing | USB printer or METTLER TOLEDO P25 thermal printer |
| Optional Automation | InMotion KF Heated Autosampler |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.1 mV |
| Moisture Range | 10 ppm to 100% (w/w) |
| Accuracy | ±0.3% (for samples containing >10 mg H₂O) |
| Minimum Dispensing Volume | 0.05 µL |
| Titration Control Precision | 20,000 steps |
| Supported Languages | 10 (English, German, French, Italian, Spanish, Chinese, Russian, Polish, Korean, Portuguese) |
| Preloaded Methods | 11 METTLER TOLEDO Expert Methods |
| User-Defined Methods | Up to 100 |
| Task Queue Capacity | 10 tasks |
| Optional Dryer | DO308 (manual) or Stromboli (automated, 14-position) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model Series | WMC / PDX / FWC |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Country of Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X12 X-ray Inspection System User Guide |
| Training Experience | 10+ Years |
| Instrument Type | Physical Property Testing Instrument |
