METTLER TOLEDO
Filter
Showing 301–330 of 567 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | MR6001 Precision Balance |
| IP Rating | IP43 |
| Construction | Full-metal housing |
| Overload Protection | Yes |
| Power Management | Configurable energy-saving mode |
| Connectivity | RS232, USB, Ethernet (MT-SICS compliant) |
| User Management | Role-based access control with configurable profiles |
| Compliance | Designed for GLP/GMP environments |
| Software Integration | Compatible with PLC, MES, and LIMS via standard protocols |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | MR6002 Precision Balance |
| IP Rating | IP43 |
| Construction | Full-metal housing with chemical-resistant surfaces |
| Overload Protection | Integrated sensor protection against mechanical shock and pan drop |
| Power Management | Configurable energy-saving mode |
| Connectivity | RS232, USB, Ethernet (optional), MT-SICS command protocol compliant |
| User Management | Role-based access control with customizable user groups and application visibility |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | MR603 Precision Balance |
| IP Rating | IP43 |
| Construction | Full-metal housing with dust- and chemical-resistant components |
| Overload Protection | Integrated sensor protection against mechanical shock and pan drop |
| Power Management | Configurable energy-saving mode |
| Connectivity | RS232, USB, Ethernet |
| User Management | Role-based access control with customizable profiles |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MS Precision Balance |
| Instrument Type | Precision Balance |
| Maximum Capacity | ≥5000 g |
| Readability | 1 mg (0.001 g) to 1 g |
| Sensor Technology | MonoBloc® single-module weighing cell |
| Repeatability (sd) | 0.001–0.5 mg (model-dependent) |
| Linearity Error | 0.002–0.3 mg (model-dependent) |
| Pan Dimensions | 127×127 mm to 351×245 mm |
| Calibration | FACT™ automatic internal calibration or external calibration (models ending in “E”) |
| Connectivity | RS232 and USB interfaces |
| Display | High-Contrast Display (HCD) |
| Leveling | Front-access leveling feet with integrated bubble level indicator |
| Draft Shield | QuickLock™ removable glass draft shield (dishwasher-safe for 0.001 g models) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MS Semi-Micro Balance |
| Readability | 0.01 mg (10 µg) |
| Max Capacity | up to 220 g (dual-range models) |
| Repeatability (sd) | as low as 0.02 mg |
| Linearity Error | ≤ 0.2 mg |
| Pan Diameter | Ø80 mm |
| Calibration Technology | FACT (Fully Automatic Calibration Technology) with internal dual-weight system |
| Display | High-Contrast Display (HCD) |
| Draft Shield | QuickLock modular glass draft shield with ErgoDoor left/right reversible door mechanism |
| Connectivity | RS232 and USB interfaces |
| Built-in Applications | Weighing, Statistics, Piece Counting, Percentage Weighing, Density Determination, Dynamic Weighing, Checkweighing, Value Recall |
| Compliance | Designed and manufactured in accordance with ISO 9001, ISO/IEC 17025, and GLP/GMP documentation requirements |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MS-TS |
| Type | Precision Balance |
| Capacity | ≥5000 g |
| Readability | 0.001 g |
| Display | 7-inch full-color TFT touchscreen |
| Character height | 18 mm |
| Leveling system | 3 fixed feet + 2 locking leveling feet |
| Calibration | FACT fully automatic internal calibration |
| Sensor technology | MonoBloc single-module weighing cell |
| MinWeigh function | visual red alert when sample mass falls below user-defined minimum weighing value |
| Sample ID tracking | up to 4 identifiers per weighing (e.g., operator, sample ID, batch, date) |
| LevelControl | real-time tilt detection with on-screen leveling guidance |
| Overload protection | built-in mechanical and electronic protection |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Type | Precision Balance |
| Model | MS-TS |
| Compliance | ISO/IEC 17025-compatible operation |
| Calibration | FACT (Fully Automatic Calibration Technology) with internal calibration weights |
| Sensor | MonoBloc single-module high-resolution electromagnetic force compensation sensor |
| Leveling System | 3 fixed feet + 2 locking leveling feet with LevelControl real-time tilt monitoring |
| Overload Protection | Integrated mechanical and electronic overload safeguard |
| Readability | Typically 0.1 mg to 1 mg (model-dependent) |
| Repeatability | ≤ ±0.0002 g (at full capacity, per ISO 9001 verification protocol) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MS104TS |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 120.0 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Minimum Weight (USP <41> typical) | 160.0 mg |
| Calibration | Internal |
| Display | 7-inch full-color capacitive touchscreen |
| Connectivity | USB Host, USB Device, RS232, Bluetooth (optional) |
| Draft Shield | QuickLock removable without tools |
| Security | Password-protected access for calibration and configuration |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | MS104TS/02 |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 120 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg (at 100 g) |
| Minimum Weight (USP) | 0.16 g (typical) |
| Stabilization Time | 2 s |
| Pan Diameter | 90 mm |
| Calibration | Internal / FACT |
| Interface | RS232, USB Device, USB Host, Bluetooth (optional) |
| Housing Material | Die-cast aluminum |
| Dimensions (H×W×D) | 347 × 347 × 204 mm |
| Legal for Trade | No |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MS105 |
| Maximum Capacity | 120 g |
| Readability | 0.01 mg |
| Repeatability | 1 mg |
| Calibration | Internal FACT (Fully Automatic Calibration Technology) |
| Sensor Technology | MonoBloc Single-Module Weighing Cell |
| Processor | 280 MIPS CPU with 72 MHz Bus Speed |
| Display | High-Contrast Display (HCD) with SmartTrac Dynamic Range Indicator |
| Keypad | Three Programmable SmartKeys + Oversized Tare Key |
| Readability Adjustment | 1/10d Mode for Rapid Stabilization |
| Environmental Compensation | Real-Time Dynamic Temperature Compensation & Multi-Stage Digital Filtering |
| Built-in Diagnostics | Keyboard Test, Repeatability Test, and Self-Maintenance Routines |
| Compliance | Designed to Support GLP/GMP Documentation Requirements, ASTM E899, ISO/IEC 17025 Traceability Framework |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Series | MS105 / MS105DU / MS205DU / MS104S / MS204S / MS304S |
| Readability | 0.01 mg / 0.1 mg (model-dependent) |
| Max Capacity | 42 g to 320 g (model-dependent) |
| Repeatability (sd) | 0.02 mg to 0.1 mg |
| Linearity Error | 0.1 mg to 0.3 mg |
| Pan Diameter | Φ80 mm |
| Clearance Above Pan | 225 mm |
| Sensor Technology | MonoBloc® High-Performance Single-Module Load Cell |
| Calibration | Fully Automatic FACT (Frequency Adaptive Calibration Technology) |
| Display | High-Contrast Display (HCD) with SmartTrac™ Dynamic Range Indicator |
| Processor | 280 MIPS CPU, 72 MHz Bus Speed |
| Operating Environment | Temperature-compensated, multi-stage digital filtering, self-diagnostics |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MS204TS |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg (at 200 g) |
| Internal Calibration | FACT (Fully Automatic Calibration Technology) |
| Minimum Weight (USP <1251>, 0.1% RSD) | 0.24 g |
| Weighing Pan Diameter | 90 mm |
| Display | 7" Color TFT Touchscreen |
| Stabilization Time | 2 s |
| Linearity Error (typ.) | ±0.2 mg |
| Temperature Drift Compensation | ±1.5 ppm/°C |
| Construction | Die-cast Aluminum Housing with Full Metal Frame |
| Connectivity | RS232, USB Device, USB Host |
| Power Supply | AC Adapter Included |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MS303TS |
| Maximum Capacity | 320 g |
| Readability | 1 mg |
| Repeatability (typ.) | 0.7 mg |
| Minimum Weight (USP <0.1% RSD, k=2) | 1.4 g |
| Linearity (typ.) | 0.6 mg |
| Settling Time | 1.5 s |
| Weighing Pan Dimensions | 127 mm × 127 mm |
| Display | 7" color TFT touchscreen |
| Interfaces | RS232, USB Device, USB Host |
| Housing | Die-cast aluminum |
| Temperature Stability | ±3 ppm/°C |
| Power Supply | AC |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MS303TS |
| Instrument Type | Precision Balance |
| Maximum Capacity | 320 g |
| Readability | 1 mg |
| Repeatability | 1 mg |
| Calibration | Internal |
| Compliance | ISO/IEC 17025, USP Chapter 41 & 1251, ASTM E898, GLP/GMP-ready |
| Construction | Die-cast aluminum housing with stainless steel pan |
| Display | 7-inch full-color capacitive touchscreen (1280 × 800 px), 18 mm character height |
| Environmental Protection | IP54-rated enclosure |
| Leveling System | Three fixed feet + two LevelLock™ locking leveling feet with LevelControl™ real-time guidance |
| Overload Protection | Integrated mechanical and electronic overload safeguards |
| MinWeigh® Function | Configurable minimum weight enforcement with visual red/green status indicator |
| Operating Temperature Range | 10–30 °C |
| Humidity Range | 10–80 % RH (non-condensing) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MS304TS/02 |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 320 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg (at 100 g) |
| Minimum Weight (USP) | 0.16 g |
| Stabilization Time | 3 s |
| Pan Diameter | 90 mm |
| Calibration | Internal / FACT |
| Interface | RS232, USB Device, USB Host, Bluetooth (optional) |
| Housing Material | Die-cast aluminum |
| Dimensions (D×H×W) | 347 × 347 × 204 mm |
| Legal for Trade | No |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MT5 / MX5 |
| Age | 3–4 years |
| Warranty | 6 months |
| Compliance | CE, ISO/IEC 17025-compatible operation |
| Calibration | Factory-tested and verified per internal QA protocol |
| Configuration | Complete system with draft shield, calibration weights, power supply, and user documentation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MultiMax |
| Type | Reaction Calorimeter (Heat Flow Calorimetry System) |
| Configuration | Modular Parallel Reactor Platform with Independent Temperature, Agitation & Dosing Control |
| Thermal Measurement Principle | Heat Flow Calorimetry (HFC) |
| Compliance | Designed for GLP/GMP-aligned process development environments |
| Software Integration | iC Safety & iC DataCenter (21 CFR Part 11 compliant audit trail, electronic signatures) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MX Precision |
| Readability | 0.01 mg to 1 g |
| Max Capacity | 320 g to 32.2 kg |
| Repeatability (5% load) | 0.5 mg to 400 mg |
| Linearity | 0.6 mg to 300 mg |
| Stabilization Time | 0.8 s to 1.5 s |
| Dimensions (W × D × H) | 194–354 mm × 379–380 mm × 100–353 mm |
| Pan Size | 127 × 127 mm to 352 × 246 mm |
| Certifications | OIML, NTEP, USP-compliant minimum weight validation |
| Interface | USB-A, USB-C, Ethernet, optional Bluetooth |
| Software | MT-SICS, EasyDirect™ |
| Environmental Rating | IP54 |
| Construction | Full-metal housing with QuickLock draft shield |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MX Series (MX105, MX105DU, MX205DU, MX104, MX204, MX304) |
| Maximum Capacity | 120 g / 220 g / 320 g |
| Readability | 0.01 mg to 0.1 mg |
| Repeatability (at 5% load) | 0.0125–0.1 mg |
| Linearity | 0.06–0.3 mg |
| Stabilization Time | 2 s |
| Pan Diameter | 80–90 mm |
| Dimensions (W × D × H) | 222 × 379 × 353 mm |
| Certifications | OIML R76, NTEP Class I, USP <41> & <1251> compliant |
| Interface Options | USB-A, USB-C, Ethernet, Bluetooth (optional) |
| Software | MT-SICS, EasyDirect™ |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | MX104 |
| Maximum Capacity | 104 g |
| Readability | 0.01 mg |
| Calibration | Internal & External |
| Compliance | GxP, ISO/IEC 17025, USP <41>, ASTM E898 |
| Connectivity | RS232, USB, Ethernet (optional), Bluetooth (optional) |
| Draft Shield | Motorized ErgoDoor with Backlit Glass |
| Power Mode | EcoMode with Auto Standby |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | MX104/A |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 120 g |
| Readability | 0.1 mg |
| Repeatability (typical) | 0.05 mg |
| Minimum Weight (U=1%, k=2, typical) | 10 mg |
| Stabilization Time | 2 s |
| Calibration | Internal (fully automatic FACT) |
| Display | 7-inch color TFT touchscreen |
| Pan Diameter | 90 mm |
| Dimensions (H×W×D) | 353 mm × 222 mm × 379 mm |
| Protection Class | IP41 |
| Certified Readability | 1 mg |
| Connectivity | USB-A, USB-C, Ethernet (LAN), Bluetooth (optional) |
| Compliance | GxP, USP <41>, <1251>, ISO/IEC 17025, FDA 21 CFR Part 11 (with LabX software) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | MX105 Analytical Balance |
| Readability | 0.01 mg |
| Pan Size | 90 mm diameter |
| Stabilization Time | ≤2 s (typical) |
| Interface Options | RS232, USB, Ethernet (optional) |
| Compliance | GxP-ready, ISO/IEC 17025 support, FDA 21 CFR Part 11 compatible (with LabX software) |
| Built-in Quality Assurance | FACT automatic internal calibration, StatusLight, SmartPan anti-vibration weighing pan, ErgoDoor draft shield |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | MX105/A |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 120 g |
| Readability | 0.01 mg |
| Repeatability (typ.) | 0.0125 mg |
| Minimum Weight (U=1%, k=2, typ.) | 2.5 mg |
| Stabilization Time | 2 s |
| Calibration | Internal (fully automatic FACT) |
| Display | 7-inch color TFT touchscreen |
| Pan Diameter | 80 mm |
| Dimensions (H×W×D) | 353 mm × 222 mm × 379 mm |
| Connectivity | USB-A, USB-C, Ethernet (LAN), Bluetooth (optional) |
| Compliance | GxP, USP <41>, <1251>, ISO/IEC 17025, FDA 21 CFR Part 11 (with appropriate software configuration) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | MX105DU Analytical Balance |
| Maximum Capacity | 105 g |
| Readability | 0.01 mg |
| Repeatability (sd) | ≤ 0.01 mg |
| Linearity | ± 0.02 mg |
| Stabilization Time | ≤ 2 s |
| Internal Calibration | Yes (motorized, temperature-compensated) |
| Connectivity | RS232, USB, Ethernet, Bluetooth (optional) |
| Compliance | ISO/IEC 17025, USP <41>, <1251>, ASTM E898, FDA 21 CFR Part 11 ready (with LabX software) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | MX105DU/A |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 42 g / 120 g |
| Readability | 0.01 mg / 0.1 mg |
| Repeatability (typ.) | 0.0125 mg |
| Minimum Weight (USP <41>, k=2, 0.1% tolerance, typ.) | 25 mg |
| Minimum Weight (uncertainty U=1%, k=2, typ.) | 2.5 mg |
| Stabilization Time | 2 s |
| Calibration | Internal (fully automatic FACT) |
| Display | 7-inch color TFT touchscreen |
| Pan Diameter | 80 mm |
| Dimensions (H×W×D) | 353 mm × 222 mm × 379 mm |
| Interfaces | USB-A, USB-C, Ethernet (LAN), Bluetooth (optional) |
| Certified Readability | 1 mg |
| Compliance | GxP-ready, USP <41>, ISO/IEC 17025 support, FDA 21 CFR Part 11 audit trail capable |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | MX12001L Precision Balance |
| Max Capacity | 32 kg |
| Readability | 1 mg |
| IP Rating | IP54 |
| Compliance | GxP-ready, FDA 21 CFR Part 11–compatible data handling (via optional software), GLP/GMP traceability support |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | MX12002 Precision Balance |
| Maximum Capacity | 32 kg |
| Readability | 1 mg |
| Protection Class | IP54 |
| Compliance | GxP-ready, FDA 21 CFR Part 11 compatible (with optional software), GLP/GMP audit trail support |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | MX1203 Precision Balance |
| Max Capacity | 32 kg |
| Readability | 1 mg |
| IP Rating | IP54 |
| Compliance | GxP-ready, FDA 21 CFR Part 11 compatible (with optional software), GLP/GMP audit trail support |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | MX1203/A |
| Instrument Type | Precision Balance |
| Maximum Capacity | 1,220 g |
| Readability | 1 mg |
| Minimum Weight (U=1%, k=2) | 100 mg (typical) |
| Minimum Weight (USP <41>, 0.1% tolerance) | 1 g (typical) |
| Repeatability | 0.5 mg (typical) |
| Stabilization Time | 1.5 s |
| Calibration | Internal (fully automatic FACT technology) |
| Pan Dimensions (W×D) | 127 mm × 127 mm |
| Display | 7-inch color TFT touchscreen |
| Interfaces | USB-A, USB-C, Ethernet (LAN), Bluetooth (optional) |
| Protection Class | IP41 |
| Verification Division Value | 0.01 g |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | MX1203N Precision Balance |
| Maximum Capacity | 32 kg |
| Readability | 1 mg |
| Protection Class | IP54 |
| Compliance | GxP-ready, FDA 21 CFR Part 11 compatible (with optional software), GLP/GMP audit trail capable |
