OEM / Custom-Built
Filter
Showing 31–60 of 83 results
| Key | Brand: OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 300°C (customizable up to 500°C) |
| Control Accuracy | ±0.5°C |
| Temperature Uniformity | ±1.5°C |
| Interior Material | SUS#304 Stainless Steel |
| Exterior Material | Powder-Coated Cold-Rolled Steel |
| Heating System | 2 kW Nickel-Chromium Far-Infrared Heater |
| Control System | Microprocessor-Based PID Controller with SCR Power Regulation |
| Compliance | GB/T 2423.2 (High-Temperature Environmental Testing for Electrical and Electronic Products) |
| Power Supply | AC 220±5% V / 50 Hz or AC 380±5% V / 50 Hz |
| Internal Dimensions (OK-T-72) | 45×40×40 cm (W×H×D) |
| Internal Dimensions (OK-T-150) | 50×60×50 cm (W×H×D) |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (FOB) |
| Temperature Range | −70 °C to +150 °C |
| Rapid Thermal Cycling Range | −45 °C to +85 °C |
| Max Linear Ramp Rate | 15 °C/min |
| Humidity Range (Optional) | 5–98% RH |
| Temp. Resolution/Accuracy | 0.1 °C / ±0.5 °C |
| Humidity Resolution/Accuracy | 0.1% RH / ±2.5% RH |
| Uniformity | ±2.0 °C / ±3.0% RH |
| Construction | Interior & Exterior – SUS304 Stainless Steel (Brushed Finish) |
| Insulation | High-Density Polyurethane Foam with Closed-Cell Structure |
| Cooling Options | Air-Cooled or Water-Cooled Condensing System |
| Refrigerant | R-404A & R-507 (EPA SNAP-Approved, Non-Ozone-Depleting) |
| Compressor | Tecumseh (France) |
| Control Interface | LCD Touchscreen with Multi-Segment Programmable Logic |
| Compliance | ASTM D3574, IEC 60068-2-1/2/14/30, MIL-STD-810H (Thermal Shock), ISO 16750-4 |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,500 (FOB) |
| Compliance | IEC 60529, ISO 20653, SAE J575, GB/T 4208 |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,500 (FOB) |
| Compliance | IPX5, IPX6 per IEC 60529, ISO 20653, GB/T 4208, MIL-STD-810G Method 512.6, ASTM D7706 |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price Reference | USD 3,100 (ex-works, subject to configuration and certification requirements) |
| Compliance | GB/T 5170.2–1996, GB/T 10592–2008, GB/T 2423.2–2008 (IEC 60068-2-2), GJB 150.3A–2009, GJB 150.4A–2009, MIL-STD-810H |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (FOB) |
| Compliance | GB/T 2423.1–2023, GB/T 2423.2–2023, IEC 60068-2-1, IEC 60068-2-2, GJB 1032A–2019, MIL-STD-2164A |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,800–3,200 (FOB) |
| Temperature Range | –40 °C to +150 °C (standard) |
| Humidity Range | 30–98 % RH (standard) |
| Temp. Resolution | 0.01 °C |
| Humidity Resolution | 0.1 % RH |
| Temp. Uniformity | ±0.5 °C |
| Temp. Deviation | ≤ ±2 °C |
| Humidity Deviation | ≤ ±2.5 % RH |
| Heating Rate | 2.0–3.0 °C/min |
| Cooling Rate | 0.7–1.0 °C/min |
| Control System | TEMI880 color LCD touchscreen controller with programmable ramp-soak profiles |
| Power Supply | 380 V ±5 %, 50 Hz, 3P+N+G (custom 220 V available) |
| Interior Material | SUS304 stainless steel |
| Exterior Material | SUS304 stainless steel or A3 steel with epoxy powder coating |
| Compliance | GB10589, GB10592, GB11158, GB/T5170.2, GB/T5170.5, GB2423.1, GB2423.2, GB2423.22, GB2424.1 |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Program Groups | 120 |
| Total Program Segments | 1,200 |
| Max Repetitions per Command | 999 |
| Segment Duration Range | 0–99 h 59 min |
| Power-Failure Recovery | Yes, auto-resume with state retention |
| Real-Time Graphical Curve Display | Yes |
| PID Parameter Sets | 9 independent groups |
| Saturation Chamber | Heated, oil-filtered, humidity-conditioned air supply |
| Spray Mode | Pneumatic atomization (continuous or intermittent) |
| Compressed Air Control | Regulated via precision pressure-reducing valve + solenoid shut-off valve |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Power Supply | AC 220 V ±10% / 50 Hz or AC 380 V ±10% / 50 Hz |
| Operating Ambient | 5–30 °C, ≤85% RH |
| Chamber Construction | Fiberglass-Reinforced Polymer (FRP) Monolithic Body |
| Sealing Method | Water-Seal Lid Design |
| Safety Protections | Overtemperature, Leakage Current, Short-Circuit, Low-Water Level, Overcurrent, End-of-Test Auto-Shutdown |
| Standard Accessories | V-Type Sample Racks (2 pcs), Dual Nozzles, Calibration Funnel & Graduated Cylinder, Water Filter on Brine Suction Line, Preheated Brine Delivery System |
| Compliance Standards | GB/T 2423.17–2022, IEC 60068-2-11, ASTM B117, ISO 9227, MIL-STD-810H (Method 509.6), DIN 50021 |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Chamber Models | SH-60 (W1300×D850×H600 mm), SH-80 (W1600×D850×H600 mm), SH-120 (W2000×D900×H600 mm) |
| Temperature Range | +10°C to +50°C |
| Humidity Range | 85–98% RH |
| Temp. Uniformity | ≤2°C |
| Temp. Stability | ±0.5°C |
| SO₂/H₂S Delivery | High-Purity Gas Cylinder System |
| Gas Concentration Control | 0.1–1.0 vol% (adjustable via mass flow controller) |
| Salt Spray Modes | Continuous (ASTM B117), Cyclic (GB/T 9789–1988, DIN 50018) |
| Saturation Tank Temp. | 47°C (NSS), 63°C (Corrosion Mode) |
| Controller | PID-Based Digital Display with ±0.1°C Accuracy |
| Safety Features | Dual Over-Temperature Protection, Auto-Water Replenishment, Low-Water Level Alarm |
| Key | Brand: OEM / Custom-Built |
|---|---|
| Origin | Imported (Global Sourcing) |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (FOB) |
| Control System Options | TIME880 Color Touchscreen Controller (Korea), TIME300 Digital Film-Button Controller (Korea), OYO 8227 PID Touch Controller (Japan) |
| Sensor | PT100 Platinum Resistance Thermometer |
| Refrigeration | Hermetic Tecumseh or Semi-Hermetic Copeland Scroll Compressor |
| Heating | Independent Ni-Cr Alloy Sheathed Heater |
| Insulation | 80–100 mm High-Density Glass Fiber Blanket |
| Viewing Window | 300 × 400 mm Tempered Double-Glazed with Integrated Heating Element |
| Test Port | Ø50 mm Left-Side Penetration Port |
| Sealing | Dual-Layer High-Tensile Silicone Gasket (–70°C to +150°C Operational Range) |
| Compliance | Designed to Support ASTM D3418, IEC 60068-2-14, MIL-STD-810H Method 503.7 Protocols |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Max Payload Capacity | 500 kg |
| Max Sinusoidal Force | 2000 kgf |
| Frequency Range | 1–5000 Hz (±0.1%) |
| Peak Acceleration | 0–20 g (0–196.13 m/s²) |
| Displacement (p-p) | 0–5 mm |
| Ambient Operating Range | −10°C to +60°C, 10–95% RH |
| Noise Level | ≤60 dB(A) |
| Magnetic Field Emission | ≤110 mG at 1 m |
| Power Supply | 220 V ±20%, 50/60 Hz, 10 A, 2.2 kW |
| Cooling | Natural Air-Cooled |
| Table Dimensions | 500 × 500 × 6 mm (L×W×H) with 25 × M10 threaded mounting holes |
| Base Dimensions | 50 × 50 × 45 cm (L×W×H) |
| Compliance | Designed for ASTM D999, ISO 13373-1, IEC 60068-2-6, MIL-STD-810H Method 514.8, and GB/T 2423.10 |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | Not Specified |
| Model | OK-S-20 |
| Price | USD 14,000 (approx.) |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported (Global Sourcing) |
| Manufacturer Type | Authorized Distributor |
| Model | OK-TH-800 |
| Temperature Range | −65 °C to +150 °C |
| Humidity Range | 20–95 % RH |
| Temp. Uniformity | ±2.0 °C |
| Temp. Stability | ±0.5 °C |
| Humidity Uniformity | ±3.0 % RH |
| Humidity Stability | ±1.5 % RH |
| Heating Rate | ≥2.5 °C/min (from 20 °C to 85 °C in ≤60 min) |
| Cooling Rate | ≥1.0 °C/min (from 20 °C to −40 °C in ≤70 min) |
| Refrigeration System | Dual-stage mechanical refrigeration (hermetic compressors, R23/R404A) |
| Internal Material | Mirror-finish SUS304 stainless steel |
| Insulation | 100 mm high-density glass fiber + polyurethane foam |
| Control System | TEMI880 color touchscreen PID controller with data logging, alarm history, and curve visualization |
| Compliance | GB/T 2423.1–4, GB 5170.2–6, IEC 60068-2-1, -2, -3, -30 |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range (Test Zone) | A: 0 °C to −40 °C |
| B | −10 °C to −55 °C |
| C | −10 °C to −65 °C |
| High-Temp Zone | +60 °C to +200 °C |
| Low-Temp Zone | A: −10 °C to −40 °C |
| B | −10 °C to −60 °C |
| C | −10 °C to −70 °C |
| Temperature Uniformity | ±3 °C |
| Temperature Stability | ±0.5 °C |
| Temperature Transition Time (Hot ↔ Cold) | ≤15 s |
| Recovery Time (to Setpoint) | 3–5 min |
| Heating Rate (High-Temp Chamber) | ~5 °C/min (avg.) |
| Cooling Rate (Low-Temp Chamber) | ~1.5 °C/min (avg.) |
| Dwell Time per Phase | ≥30 min |
| Test Port | Ø50 mm (left side) |
| Control System | PLC-based PID controller with 7″ color LCD HMI |
| Programmable Cycles | 1–999 |
| Soak Duration | up to 999 h 59 min |
| Predefined Test Standards | 96 built-in profiles |
| Compliance | Designed for ASTM D5229, ISO 16750-4, MIL-STD-810H Method 503.5, JESD22-A104, IEC 60068-2-14 |
| Key | Brand: OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 6,300 (FOB) |
| Chamber Volume | 80 L / 225 L / 500 L / 1000 L |
| Internal Dimensions (W×H×D, cm) | 40×50×40 |
| External Dimensions (W×H×D, cm) | 100×170×90 |
| Temperature Range | 25–40 °C |
| Temp. Uniformity | ±0.5 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Monitoring | Imported UV Absorption Analyzer with 4–20 mA Output & RS232 Interface |
| Sample Rack | Motor-Driven, 360° Continuous Rotation (1 rpm), Cycloidal Trajectory Compliance |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weintek Color Touchscreen + Siemens S7-1200 PLC |
| Safety Protections | Leakage Current, Short-Circuit, Over-Temperature, Motor Overheat, Over-Current |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 14,200 (FOB) |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price Range | USD 14,000–16,500 (FOB) |
| Temperature Range (High Zone) | +80°C to +200°C |
| Temperature Range (Low Zone) | −10°C to −70°C |
| Operational Test Range | −40°C to +150°C |
| Control Accuracy | ±2.0°C |
| Resolution | 0.01°C |
| High-Zone Ramp Rate (RT → +150°C) | ≤40 min |
| Low-Zone Ramp Rate (RT → −70°C) | ≤100 min |
| Test Zone Temperature Recovery Time | 3–5 min |
| Internal Dimensions (W×H×D) | 600 × 500 × 500 mm |
| External Dimensions (W×H×D) | 1500 × 2100 × 2250 mm |
| Construction | Dual-chamber (hot/cold) + test chamber |
| Inner/Outer Material | SUS304 stainless steel (polished finish) |
| Insulation | High-density glass wool + rigid polyurethane (PU) foam |
| Anti-sweat System | K-type thermocouple-based thermal energy redistribution |
| Sealing | High-tensile elastomeric packing (−200°C to +400°C) |
| Actuation | Pneumatic damper control for zone isolation |
| Accessories | Two adjustable stainless-steel test shelves |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price Reference | USD 3,600 (ex-works, indicative only) |
| Turntable Dimensions | 500 × 500 mm |
| Turntable Speed | 1–17 rpm (infinitely variable via inverter drive) |
| Turntable Tilt Angle | 30°–90° adjustable |
| Drip Tank Height Adjustment | 200–2000 mm |
| Chamber Internal Dimensions | Customizable per client specification |
| Operating Temperature Range | Ambient to 100 °C (PID-controlled heating optional) |
| Spray Pressure Range | 0.3–0.76 MPa (adjustable via calibrated pressure regulator) |
| Oscillating Pipe Swing Angles | 90°–270° or 360° continuous |
| Oscillating Pipe Radius | 200 mm (standard), customizable |
| Pipe Diameter | Ø16 mm |
| Nozzle Orifice Diameter | Ø0.4 mm (for IPX1–IPX3) or Ø1.2 mm (for IPX4–IPX6) |
| Nozzle Spacing | 12.5 mm (per IEC 60529 & ISO 20653) |
| Compliance | Fully configurable to meet IEC 60529 (IP Code), ISO 20653, SAE J575, GB/T 4208, and MIL-STD-810H Method 512.5 |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,500 (FOB) |
| Compliance | IPX3, IPX4 per IEC 60529, ISO 20653, GB/T 4208, GJB 150.8, GB/T 2423.38, IEC 60068-2-68 |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 29,800 (FOB Shanghai) |
| Temperature Range | −65 °C to +150 °C |
| Humidity Range | 20–95 % RH |
| Temp. Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Temp. Fluctuation | ±0.5 °C |
| Humidity Fluctuation | ±1.5 % RH |
| Heating Rate (20 °C → 85 °C) | <60 min (no-load, non-linear) |
| Cooling Rate (20 °C → −40 °C) | <70 min (no-load, non-linear) |
| Power Supply | 3-phase 5-wire AC 380 V, 50 Hz, PE grounded |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 29,500 (FOB Shanghai) |
| Temperature Range | −65 °C to +150 °C |
| Humidity Range | 20–95 % RH |
| Temp. Uniformity | ±2.0 °C |
| Temp. Stability | ±0.5 °C |
| Humidity Uniformity | ±3.0 % RH |
| Humidity Stability | ±1.5 % RH |
| Heating Rate (20 °C → 85 °C) | <60 min (unloaded, non-linear) |
| Cooling Rate (20 °C → −40 °C) | <70 min (unloaded, non-linear) |
| Airflow Cooling | Water-cooled (inlet water temp. 10–28 °C, pressure 0.1–0.3 MPa) |
| Power Supply | 3-phase 5-wire AC 380 V, 50 Hz, PE grounded |
| Compliance | GB10589, GB10592, GB11158, GB/T 5170.2 & 5170.5, GB 2423.1/2/22, GB 2424.1 |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,100 (FOB) |
| Temperature Range | −40 °C to +150 °C (standard) |
| Humidity Range | 30–98 % RH (standard) |
| Temp. Resolution | 0.01 °C |
| Humidity Resolution | 0.1 % RH |
| Temp. Uniformity | ±0.5 °C |
| Temp. Deviation | ≤ ±2 °C |
| Humidity Deviation | ≤ ±2.5 % RH |
| Heating Rate | 2.0–3.0 °C/min |
| Cooling Rate | 0.7–1.0 °C/min |
| Control System | TEMI880 Color LCD Touchscreen Controller |
| Power Supply | 380 V ±5 %, 50 Hz, 3P+N+G |
| Internal Chamber Material | SUS304 Stainless Steel |
| Compliance | GB10589, GB10592, GB11158, GB/T5170.2, GB/T5170.5, GB2423.1/2/22, GB2424.1 |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,000 (FOB) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (Single) |
| Sample Rack Dimensions | 500 × 400 mm |
| Irradiation Geometry | Top-Mounted Reflector-Based Direct Illumination |
| Spectral Range | 295–450 nm |
| Irradiance Level | 200 ± 8 W/m² (at sample plane) |
| Irradiance Uniformity | ≥90% across rack surface |
| UV Monitoring | Integrated UV Spectral Irradiance Transmitter (developed by China Academy of Engineering Physics – Institute 622) |
| Filter System | Custom High-Borosilicate Glass + IR-Blocking Filter (removes ~30% infrared energy) |
| Control Interface | LCD-based Irradiance Accumulation Meter with Real-Time Dose Integration |
| Cooling Method | Internal Forced-Air Circulation System |
| Compliance | Designed per ISO 4892-2, ASTM G155, SAE J2527, and GB/T 16422.2 requirements |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Compliance | GB/T 2423.1–2008 (Test A), GB/T 2423.2–2008 (Test B), GB/T 10592–2008, GJB 150.3–1986, GJB 360A–1996 Method 107 |
| Cooling Medium | Eco-Friendly R404A/R23 Cascade Refrigerant |
| Control Interface | LCD Touchscreen with Dialog-Based UI |
| Construction | Stainless Steel + Pre-Painted Galvanized Steel Panels |
| Air Circulation | Horizontal Centrifugal Forced-Air System with Vertical Heat Exchange |
| Safety Features | Over-Temperature/Over-Current Protection, Power-Fail Memory, Real-Time Fault Logging & Diagnostic Guidance |
| Refrigeration Architecture | Dual-Stage Cascade Cryogenic System with Zone-Specific Compressor Optimization |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 14,200 (FOB) |
| Operating Ambient | 15–35 °C, ≤85% RH |
| Safety Protections | Overcurrent, Ground Fault, Overtemperature, Compressor High-Pressure & Overload Cut-off |
| Compliance | IEC 60068-2-14, MIL-STD-810H Method 503.7, GB/T 2423.22 |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Compliance | MIL-STD-810G, GJB 150.3A–2009 (High Temp), GJB 150.4A–2009 (Low Temp), IEC 60068-2-14 |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 11,200 (FOB) |
| Temperature Range | −65°C to +180°C |
| Transition Time (50°C to −50°C) | ≤15 s (typical, per IEC 60068-2-14) |
| Test Zone Volume | Standard 100 L (customizable: 30–500 L) |
| Control System | 7″ TFT Color Touchscreen HMI with PID Auto-Tuning |
| Cooling Method | Dual-Stage Cascade Refrigeration (R404A/R23) |
| Compliance | IEC 60068-2-14, MIL-STD-810H Method 503.5, DIN EN 60068-2-14, JIS C 60068-2-14 |
| Test Zone Configuration | Three-Chamber Static-Test Architecture (High-Temp Chamber / Low-Temp Chamber / Test Chamber) |
| Safety Features | Liquid Nitrogen (LN₂)–Free Operation, Oxygen Depletion Risk Eliminated, Over-Temp/Over-Pressure/Phase Failure Protection |
| Data Logging | Real-Time Curve Plotting, Event Timestamping, Audit-Trail-Ready Export (CSV/Excel) |
| Software | Embedded Firmware v4.2 with Optional PC-Based Remote Monitoring (USB/Ethernet) |