| Brand | PREMOSYS |
|---|---|
| Origin | Germany |
| Model | PR-0104-S |
| Product Type | Color Difference Meter |
| Instrument Type | In-Line |
| Optical Geometry | 45/0° |
| Light Source | 6500 K LED |
| Spectral Range | 400–700 nm |
| Repeatability | ±0.5 ΔE (CIE Lab) |
| Brand | PREMOSYS |
|---|---|
| Origin | Germany |
| Model | PR-0130K |
| Product Type | Color Difference Meter |
| Instrument Type | In-Line |
| Optical Geometry | 45/0° |
| Light Source | 6500 K LED |
| Spectral Range | 400–700 nm |
| Repeatability | 0.5 ΔE (CIE Lab) |
| Brand | PREMOSYS |
|---|---|
| Origin | Germany |
| Model | PR-0228 |
| Product Type | Online Color Difference Meter |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | 6500 K LED |
| Spectral Range | 400–700 nm |
| Repeatability | ±0.5 ΔE* CIELAB |
| Compliance | ISO 7724, ISO 11664, ASTM E308, CIE No. 15 |
| Brand | PREMOSYS |
|---|---|
| Origin | Germany |
| Model | PR 0084 |
| Field of View | ±2° |
| Calibration | PTB-traceable |
| Flicker Measurement | Compliant with VESA standards |
| Interfaces | USB 2.0, RS232, RS232-TTL |
| Power Supply | 4.7–5.25 V DC via interface |
| Factory Presets | 8 |
| User-defined Presets | 30 |
| Max. Measurement Rate | 10 Hz (low sensitivity), 4 Hz (high sensitivity) |
| Temperature Compensation Range | 20–40 °C |
| Dimensions (L×W×H) | 61 × 26 × 17 mm (excl. mounting interface) |
| Weight | ~80 g |
| Luminance Range | 0.05–2500 cd/m² |
| Chromaticity Accuracy (relative to Illuminant D65) | ±0.002 |
| CCT Accuracy (4000–15000 K) | ±250 K |
| Chromaticity Accuracy (other spectra) | ±0.0065 |
| Luminance Accuracy | ±2% + 1 digit (1–500 cd/m²) |
| Brand | PREMOSYS |
|---|---|
| Origin | Germany |
| Model | PR0086-S |
| Product Type | Color Difference Meter |
| Instrument Type | Online |
| Light Source | 6500 K LED |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE ≤ 0.05 |
| Absolute Accuracy | ~1.6 ΔE (avg.) |
| Inter-system Relative Accuracy | < ±0.5 ΔE |
| Operating Distance | 70 mm |
| Measurement Area | Ø70 mm at 70 mm distance |
| Measurement Frequency | 10 Hz |
| Power Supply | 24 V DC |
| Interface | RS485 |
| Temperature Compensation Range | 10–55 °C |
| Housing | 2 mm stainless steel with anti-dust coating |
| Output Data | CIELAB, chromaticity coordinates, tristimulus values (X, Y, Z) |
| Software Support | WIN32 DLL |
| Brand | PREMOSYS |
|---|---|
| Origin | Germany |
| Model | PR0120 |
| Optical Detection Range | 400–700 nm |
| Sampling Rate | 2 kHz |
| Color Space | CIELAB (L*a*b*) |
| Long-Term Color Stability | ΔE < 0.2 |
| Color Resolution | < 0.1 ΔE |
| Repeatability | < 0.2 ΔE |
| Gain Stages per Channel | 11 |
| ADC Resolution | 16-bit |
| Communication Interfaces | 100 Mbps Ethernet (UDP), RS-232 |
| Power Supply | 24 V DC |
| Light Source | Dual-Power Adjustable High-Intensity LED |
| Brand | PREMOSYS |
|---|---|
| Origin | Germany |
| Model | PR0128 |
| Product Type | Online Color Difference Meter |
| Optical Geometry | 45°/0° |
| Light Source | 6500 K LED |
| Spectral Range | 400–700 nm |
| Repeatability | ≤ 0.5 ΔE* (CIELAB) |
| Operating Temperature Compensation | 18–55 °C |
| Power Supply | 24 V DC |
| Housing | Anodized Aluminum |
| Interface | RS-232 / Parallel (simultaneous) |
| Color Resolution | < 0.1 ΔE* |
| Gain Calibration | Automatic, User-Initiated |
| Max. Switching Frequency | 500 Hz |
| Supported Color Spaces | CIE L*a*b*, L*C*h*, XYZ, RGB (derived) |
| Inter-Instrument Agreement | < 1% ΔE* (under controlled conditions) |
| Brand | PREMOSYS |
|---|---|
| Origin | Germany |
| Model | PR126-C |
| Light Source | White LED (5600 K) |
| Spectral Range | 400–700 nm |
| Output Interface | Serial and Parallel (simultaneous) |
| Power Supply | 24 V DC |
| Housing | Anodized Aluminum |
| Color Space | CIELAB (L*, a*, b*) |
| Chromatic Resolution | < 0.1 ΔE |
| Repeatability | < 0.5 ΔE |
| Inter-instrument Agreement | < 1% ΔE |
| Operating Temperature Range | 18–55 °C |
| Temperature Compensation | Automatic |
| Measurement Frequency | 500 Hz |
| Gain Calibration | Auto and User-Adjustable |
| Onboard Storage | Up to 7 product definitions (PR126-C7) or 4 (PR126-C4) with background operation |
| Software | Multilingual configuration and ΔE calculation suite |
| Compliance | Designed for industrial QA/QC in regulated environments (supports GLP/GMP-aligned documentation workflows) |
| Brand | PREMOSYS |
|---|---|
| Origin | Germany |
| Model | PR190 |
| Sensitivity Range | 3.5–10,000,000 lux |
| Measurement Wavelength Range | 400–700 nm |
| Resolution | xy < 0.001, Dominant Wavelength: 1 nm, Correlated Color Temperature (CCT): 1 K |
| Measurement Time | ~25 ms per cycle |
| Gain Stages | 8 auto-ranging levels |
| ADC Resolution | 12-bit |
| Stored Configurations | 3 product profiles |
| Input Voltage | 12–27 VDC (≤3 A at 12 V) |
| Interface | Onboard serial and digital I/O |
| Calibration | User-executable illuminance & white-point calibration |
| Accuracy (White Reference) | xy ±0.0015, Relative Intensity ±2%, CCT ±100 K, Monochromatic LED Dominant Wavelength ±4 nm |
| Brand | PREMOSYS |
|---|---|
| Origin | Germany |
| Model | QuickMatch |
| Operating Temperature | Up to 400 °C |
| Measurement Principle | Reflectance/Transmittance Spectrophotometry (400–700 nm) |
| Sampling Rate | 2 kHz |
| Color Resolution | <0.1 ΔE |
| Repeatability | <0.2 ΔE |
| Optical Interface | Sapphire-tipped probe with configurable lens options |
| Output Interface | 100 Mbps Ethernet (UDP), RS-232, WIN32 DLL |
| Power Supply | 24 V DC |
| Compliance | FDA-compliant probe materials available (food-grade variant), CE-marked |