| Brand | Raypa |
|---|---|
| Origin | Spain |
| Model | DNP-3000 |
| Instrument Type | Quartz Glass Kjeldahl Distillation Apparatus |
| Nitrogen Measurement Range | 0.1–200 mg |
| Recovery Rate | 99.5% |
| Repeatability | ±1% |
| Distillation Time (100 mL) | 4 min |
| Cooling Water Consumption | 70 L/h |
| Power Rating | 2000 W |
| Programmable Parameters | Dilution Water (0–200 mL), NaOH Volume (0–200 mL), H₃BO₃ Volume (0–200 mL), Reaction Time (0–30 min), Digestion Time (0–30 min), Steam Intensity (30–100%) |
| Titration Resolution | 0.01 pH, 1 mV, 0.1 °C |
| Temperature Compensation | CAT Pt100 probe |
| Predefined Programs | 3 fixed + 20 user-definable |
| Safety Features | Open-tube detection, digestion tube presence sensor, overtemperature cut-off thermostat |
| Brand | Raypa |
|---|---|
| Origin | Spain |
| Model | FLOC-4P |
| Speed Range | 20–200 rpm |
| Timer Range | 0–60 min |
| Positions | 4 |
| Power Supply | 12 V DC (cigarette lighter socket) |
| Stirrer Height Adjustment | Yes |
| Noise Level | Low |
| Application | Bench-scale coagulation/flocculation jar testing for water and wastewater analysis |
| Brand | Raypa |
|---|---|
| Origin | Spain |
| Model | SOXTEST |
| Extraction Chamber Volume | 50 mL |
| Receiver Flask Volume | 6 mL |
| Temperature Range | RT + 5 °C to 250 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Number of Channels | 6 |
| Solvent Recovery Rate | 60–70% |
| Sample Capacity | up to 25 mL |
| Reproducibility | ±1% |
| Extraction Thimble Dimensions | Ø26 × 60 mm |
| Boiling Extraction Time | 0–500 h |
| Rinsing Extraction Time | 0–99 h |
| Compatible Solvents & Max Recommended Extraction Temperatures | Diethyl Ether (100 °C), Petroleum Ether (100 °C), Hexane (140 °C), Chloroform (150 °C), Vinyl Chloride (190 °C), Methanol (200 °C), Ethanol (200 °C), Toluene (200 °C) |
| Brand | Raypa |
|---|---|
| Origin | Spain |
| Model | UCI-75 |
| Capacity | 3 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 300 W |
| Power Adjustment | Fixed (300 W) |
| Temperature Range | Ambient to 80 °C |
| Timer Range | 0–15 min |
| Tank Material | AISI 304 stainless steel (18/10 grade) |
| External Housing | AISI 304 stainless steel |
| Lid Type | Hinged sound-dampening cover |
| Drain Valve | Manual |
| Dimensions (L×W×H) | 320 × 265 × 165 mm (external) / 110 × 230 × 135 mm (internal) |
| Weight | 6 kg |
| Brand | Raypa |
|---|---|
| Origin | Spain |
| Model | VACUTERM |
| Instrument Type | Vacuum Oven |
| Temperature Range | 35–200 °C |
| Temperature Uniformity | ±4 °C |
| Temperature Stability | ±1 °C |
| Temperature Display Accuracy | ±2 °C |
| Maximum Vacuum Level | 0.01 mbar |
| Chamber Dimensions (W×D×H) | 34 × 32 × 32 cm |
| External Dimensions (W×D×H) | 62 × 53 × 49 cm |
| Chamber Material | AISI 304 Stainless Steel |
| Door & Interior Trim | AISI 304 Stainless Steel |
| Shelving | 2 Perforated Aluminum Shelves (Epoxy-Coated) |
| Heating Method | Forced-Air Circulation |
| Safety Compliance | EN 61010-1, EN 61010-2-010 |
| Temperature Sensor | PT100 Platinum Resistance Thermometer |
| Controller | Digital Microprocessor-Based Time-Temperature Controller |
| Safety Features | Dual-Level Independent Temperature Limiter, Tempered Double-Glazed Safety Glass Door, Silicone Sealing Gasket |