REMEX (Xi’an Remex Instrument Co., Ltd.)
Filter
Showing all 5 results
| Brand | REMEX (Xi’an Remex Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | IFFM-E |
| Pump Speed Range | 0–99 digital steps |
| Dilution Ratio | 1:99 |
| High-Voltage Input | −100 to −1000 V (stability < 0.01%) |
| Spectral Response Range | 300–650 nm (peak sensitivity at 420 nm) |
| Photomultiplier Gain | 1×, 2×, 4×, 8×, 16× |
| Filter Cutoff Frequency | 10–100 Hz |
| Sampling Rate | 1–100 samples/s |
| Analog Signal Input Range | 0–5 V |
| Software | REMEX Chemiluminescence Data Acquisition & Kinetic Analysis Suite (fully localized Chinese UI) |
| Brand | REMEX (Xi’an Remex Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | MPI-E |
| Current Range | ±250 mA |
| Potential Range | −10 V to +10 V |
| Reference Electrode Input Impedance | 10 MΩ |
| Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 auto-ranging decades) |
| Input Bias Current | <50 pA |
| Potential Increment | 1 mV |
| Scan Rate | 0.001–65 V/s |
| Luminescence Detection Dynamic Range | >5 decades |
| Photomultiplier Tube (PMT) High Voltage | −100 V to −1000 V |
| Emission Wavelength Range | 300–650 nm (Peak Sensitivity at 420 nm) |
| PMT Spectral Responsivity | >1000 A/lm |
| Brand | REMEX (Xi’an Remex Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | RFL-1 |
| Dynamic Range | >6 orders of magnitude |
| PMT High-Voltage Supply | −100 V to −1000 V (stability ≤0.05%, current ≥5 mA) |
| Amplifier Gains | 1×, 10×, 100×, 1000× |
| Filter Frequencies | 10 Hz, 20 Hz, 50 Hz, 100 Hz |
| Signal Noise | ≤0.5 mV (p-p, 1× gain) |
| Input Impedance | ≥10 MΩ |
| Integration Time | 0.01–1000 s |
| Sampling Rate | 1–1000 Hz |
| Spectral Response | 300–650 nm (λₘₐₓ = 420 nm) |
| Radiant Sensitivity | >1000 A/lm |
| Software Features | Real-time zero calibration, auto-gain control, peak/area quantitation, ASCII data export, serial communication interface |
| Brand | REMEX (Xi’an Remex Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | RFL-II |
| Detector Type | Electrochemical Luminescence Analyzer with Integrated Spectral Photomultiplier Module |
| High-Voltage Power Supply | −100 V to −1000 V (stability ±0.05%, output current ≥5 mA) |
| Gain Settings | 1×, 10×, 100×, 1000× |
| Filter Frequencies | 10 Hz, 20 Hz, 50 Hz, 100 Hz |
| Signal Noise | ≤0.5 mV<sub>P-P</sub> (at 1× gain) |
| Input Impedance | ≥10 MΩ |
| Integration Time Range | 0.01–1000 s |
| Sampling Rate | 1–1000 Hz |
| Spectral Response | 230–920 nm (peak sensitivity at 630 nm) |
| Anode Sensitivity | >2000 A/lm |
| Software Functions | Real-time signal acquisition, auto-zero calibration, AGC (Automatic Gain Control), peak/area quantification, spectral export (TXT), VFD-based local parameter display |
| Brand | REMEX (Xi’an Remex Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | RPEC-A |
| Light Source | 300 W Xenon Arc Lamp |
| Spectral Range | 200–1000 nm |
| Wavelength Accuracy | ±0.25 nm |
| Wavelength Repeatability | ±0.1 nm |
| Minimum Wavelength Step | 0.01 nm |
| Spectral Bandwidth | 0.054–16.2 nm (adjustable slit: 10 µm–3 mm) |
| Electrochemical Potential Range | −10 V to +10 V |
| Current Range | ±250 mA |
| Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades) |
| Input Bias Current | <50 pA |
| Scan Rate | 0.001–65 V/s |
| Reference Electrode Input Impedance | 10 MΩ |
| Operating System | Windows-based Dedicated Software |