SANXIN
Filter
Showing all 9 results
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | 5041 |
| Measurement Range | ±100 mV |
| Resolution | 1 mV |
| Accuracy | ±0.5% FS |
| Power Supply | Two AAA batteries (1.5 V × 2) |
| Dimensions | 39 × 25 × 176 mm |
| Weight | 95 g |
| IP Rating | IP57 |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Model | LabSen873 |
| Instrument Type | Pen-Style Electrode |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 1–13 pH |
| Resolution | 0.1 pH |
| Accuracy | ±0.1 pH |
| Calibration Buffers | pH 4.00, 7.00, 10.00 |
| Temperature Range | 0–80 °C |
| Body Material | Lead-Free Glass |
| Bulb Shape | Cylindrical |
| Reference System | Ag/AgCl |
| Junction Type | Dual-Liquid Junction with Movable Sleeve |
| Internal Reference Electrolyte | 3 M KCl (Gelled) |
| Salt Bridge Solution | 1 M LiCl |
| Soaking Solution | 3 M KCl |
| Dimensions | Φ12 × 130 mm |
| Connector | BNC |
| Cable | Φ3 mm × 1 m |
| Integrated Temperature Sensor | Yes (for Automatic Temperature Compensation) |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Model | MP512 |
| Instrument Type | Benchtop |
| Parameter Type | Single-Parameter (pH/mV/°C) |
| pH Range | −2.000 to 19.999 pH |
| pH Resolution | 0.001 pH |
| pH Accuracy | ±0.002 pH |
| mV Range | −1999.9 to +1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.03% FS |
| Temperature Range | −10 to 110 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.4 °C |
| Input Impedance | ≥3 × 10¹² Ω |
| Input Current | ≤1 × 10⁻¹² A |
| Stability | ±0.002 pH / 3 h |
| ATC Range | 0 to 110 °C |
| Data Storage | 600 sets |
| Storage Content | Measurement ID, pH/mV value, temperature, ATC/MTC status, date & time |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| IP Rating | IP54 |
| Certifications | ISO 9001:2000, CE, CMC |
| Operating Environment | 15–30 °C (for 0.001-level accuracy), ≤75% RH |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Model | MP523-01 |
| Instrument Type | Benchtop |
| Measurement Range | pH: −2.000–19.999 |
| Ion Concentration | 0.00–14.00 pX (equivalent to 0.01 mg/L–1000 mg/L depending on ion valence and selectivity) |
| Temperature | −10–110 °C |
| Detection Limit | 0.01 mg/L (typical for monovalent ions) |
| Response Time | ≤60 s (for ion concentration stabilization) |
| Accuracy | pH: ±0.002 pH |
| Ion | ±0.5% of reading (monovalent), ±1.0% of reading (divalent) |
| Temperature | ±0.4 °C |
| Temperature Compensation | Automatic, 0–100 °C (pH), 0–60 °C (ion) |
| Data Storage | 900 sets |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions & Weight | 160 × 190 × 70 mm / 880 g |
| IP Rating | IP54 |
| Compliance | GLP-compliant architecture with audit-trail-capable data logging |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Model | PHB-3 |
| Instrument Type | Pen-style pH Meter |
| Measurement Range | 0.0–14.0 pH |
| Resolution | 0.1 pH |
| Accuracy | ±0.01 pH |
| Calibration | Single-point (pH 7.00) |
| Temperature Compensation | None |
| Power Supply | Two AAA batteries (1.5 V × 2) |
| Dimensions | 176 × 25 × 39 mm |
| Weight | 95 g |
| IP Rating | IP57 |
| Calibration Solution Compatibility | USA-standard pH buffers (e.g., pH 4.01, 7.00, 10.01) |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Model | SX650 |
| Portability | Pen-type |
| Application | Laboratory & Field Use |
| Conductivity Range | 0–50.0 mS/cm |
| TDS Range | 0–35.0 g/L |
| Resistivity Range | 0–20.0 MΩ·cm |
| Salinity Range | 0–25.0 ppt |
| Temperature Range | 0–50.0 °C |
| Accuracy | ±1.0% FS (Conductivity), ±0.5 °C (Temperature) |
| Resolution | 0.1 µS/cm |
| Auto-Temperature Compensation | 0–50 °C (2.0%/°C) |
| Calibration | Single-point (1413 µS/cm) |
| Power | Two CR2032 batteries (≥100 h operation) |
| Dimensions | 148 × 29 × 14 mm |
| Weight | 38 g |
| IP Rating | IP57 |
| Certifications | ISO 9001:2000, CE |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Portable |
| Parameter Types | pH, ORP, Conductivity, TDS, Salinity, Resistivity, Dissolved Oxygen, Temperature |
| pH Range | −2.00 to 19.999 |
| pH Resolution | 0.1 / 0.01 |
| pH Accuracy | ±0.01 |
| Conductivity Range | 0–200 mS/cm (5 segments) |
| Conductivity Accuracy | ±1.0% FS |
| DO Range | 0–40.00 mg/L, 0–199.9% saturation |
| DO Accuracy | ±0.10% FS |
| Temperature Compensation | Automatic (0–100 °C for pH |
| Calibration | Auto-recognition of 13 pH buffers (US, NIST, Chinese series) |
| Data Storage | 100–400 sets |
| Power | 2 × AA batteries (1.5 V), >100 h life |
| Dimensions (meter) | 65 × 120 × 31 mm |
| Weight (meter) | 180 g |
| Ingress Protection | IP57 |
| Certifications | ISO 9001:2000, CE, CMC |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Model | SX711 |
| Instrument Type | Portable (not benchtop — corrected per product reality) |
| Parameter Type | Single-parameter (pH/mV) |
| pH Range | –2.00 to 19.99 pH |
| pH Resolution | 0.1 / 0.01 pH |
| pH Accuracy | ±0.01 pH |
| mV Range | ±1999 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±0.1% FS |
| Temperature Range | –10 to 110 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Input Impedance | ≥1 × 10¹² Ω |
| Input Current | ≤2 × 10⁻¹² A |
| Stability | ±0.01 pH / 3 h |
| Auto-Temperature Compensation (ATC) | 0 to 100 °C |
| Calibration Buffers | Auto-recognized (13 standard buffers across Chinese, NIST, and European series) |
| Memory Capacity | 200 data sets (ID, pH/mV value, unit, temperature) |
| Power | Two AA batteries (1.5 V × 2) |
| Dimensions (meter) | 65 × 120 × 31 mm |
| Weight (meter) | 180 g |
| IP Rating | IP57 |
| Certifications | ISO 9001:2000, CE, CMC |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Model | TN150 |
| Type | Portable |
| Measurement Range | 0–1000 NTU (FNU), auto-ranging across three sub-ranges: 0.01–19.99 NTU (FNU), 20.0–99.9 NTU (FNU), 100–1000 NTU (FNU) |
| Resolution | 0.01 / 0.1 / 1 NTU (FNU) |
| Operating Temperature | 0–50 °C |
| Accuracy | ≤ ±8% |
| IP Rating | IP67 |
| Display | TFT color screen |
| Light Source | Tungsten filament lamp (400–600 nm) |
| Detection Principle | 90° nephelometric scattering |
| Compliance | HJ 1075–2019, EPA Method 180.1, ASTM D6508, ISO 7027–1:2016 (white light mode) |
| Calibration Standards | Certified polymer standards (0, 20, 100, 400, 800 NTU/FNU), EPA- and ASTM-compliant, 1-year shelf life |
| Battery | Rechargeable 3.7 V Li-ion (7 V system equivalent), >20 h continuous operation |
| Dimensions (instrument) | 90 × 203 × 80 mm |
| Weight (instrument) | 385 g |
| Certifications | ISO 9001:2015, CE |