Schmidt + Haensch (S+H)
Filter
Showing all 11 results
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | ATR-BR |
| Product Type | In-line / Laboratory Refractometer |
| Temperature Control | Integrated Peltier-free prism temperature sensing |
| Digital Display | Backlit LCD (16×16 characters) |
| Measurement Range | 1.32000–1.54000 RI / 0–100 %Brix |
| Resolution | 0.00001 RI / 0.01 %Brix |
| Accuracy | ±0.00002 RI / ±0.01 %Brix (1.32–1.44), ±0.00003 RI / ±0.01 %Brix (1.44–1.54) |
| Repeatability | 0.00001 RI / 0.01 %Brix |
| Temperature Sensing | NTC sensor embedded in sapphire prism, accuracy ±0.03 °C, repeatability ±0.02 °C |
| Sample Volume | 0.3 mL |
| Prism Material | Sapphire |
| Light Source | LED with integrated interference filter, λ = 589 nm |
| Interfaces | RS-232C (bidirectional), Centronics parallel port, USB (optional) |
| Compliance | ASTM D1218, DIN 51757, ISO 21542, USP <781>, ICUMSA Method GS2/3-13, AOAC 932.12, FDA 21 CFR Part 11 (with optional audit trail software) |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | ATR-L |
| Product Type | In-line Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 1.33200–1.70000 RI / 0–100% Brix |
| Measurement Accuracy | ±0.00001 RI / ±0.01 Brix |
| Temperature Control Range | 10–80 °C |
| Temperature Accuracy | ±0.03 °C |
| Wavelengths | 400, 450, 490, 525, 589, 660, 700 nm (LED-based) |
| Prism Material | YAG |
| Detection Principle | Critical Angle of Total Internal Reflection (ATR) |
| Sensor | CCD array |
| Compliance | ASTM, ISO, AOAC, DIN, ICUMSA, USP, FDA 21 CFR Part 11 (software-enabled), GLP/GMP-ready |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Country of Origin | Germany |
| Model | AutoDosage |
| Maximum Weighing Capacity | 610 g / 1500 g / 2200 g (selectable) |
| Weighing Resolution | 0.1 g or 0.01 g |
| Interface | RS-232 serial port |
| Control Interface | Integrated aluminum-finished controller housing with backlit LCD display and membrane keypad |
| Actuation | Solenoid valves with adjustable nozzles for coarse, medium, and fine dispensing |
| Software | PC-based formulation editor with recipe storage (up to 70 protocols), calibration management, and audit-ready log export |
| Structural Base | Vertical-adjustable balance support plate with mounting baseplate |
| Power Supply | 24 V DC unit included |
| Connectivity | Ethernet-ready (optional), standard network cable provided |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AutoFilt |
| Pricing | Available Upon Request |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AutoFilt Z |
| Pricing | Upon Request |
| Max. Filtration Pressure | 5 bar (0.5 MPa) |
| Typical Filtration Volume | ~250 mL |
| Measured Sample Volume | 50 mL |
| Operating Temperature Range | +10 °C to +40 °C |
| Power Supply | 100–240 VAC, 47–63 Hz, 40 W |
| Compressed Air Requirement | ≤10 bar (1.0 MPa), oil-free, Ø outer diameter 6 mm |
| Waste Tube | Ø inner diameter 16 mm |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | DHR |
| Type | Digital handheld refractometer |
| Temperature control | Yes (ATC) |
| Digital display | Yes (5-digit LCD) |
| Measurement range | 0–95 °Brix / 1.3300–1.5400 RI |
| Resolution | 0.1 °Brix / 0.0001 RI |
| Accuracy | ±0.2 °Brix / ±0.0003 RI |
| Operating sample temperature | 5–60 °C |
| Ambient temperature range | 5–40 °C |
| ATC compensation range | 5–70 °C |
| IP rating | IP65 |
| Compliance | CE, RoHS |
| Power | 2×AAA batteries |
| Dimensions (L×W×H) | 115×54×30 mm |
| Weight | 85 g (without batteries) |
| Prism material | Optical glass |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Country of Origin | Germany |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principles | Conductivity-based Ash Determination, Photometric Colorimetry at 420 nm (ICUMSA), Nephelometric Turbidity |
| Accuracy | ±1 IU (Color, ≤30 IU), ±10% (Turbidity), ±0.001% (Ash), ±0.1 °Brix (Brix) |
| Compliance | ICUMSA Method GS5/8/9-1, ASTM D1209, ISO 7027, USP <731> |
| Automation Level | Fully Automated Sample Handling, Dilution, Filtration, Measurement, and System Rinse |
| Software Integration | LIMS-ready with audit-trail-capable data acquisition, FDA 21 CFR Part 11–compliant optional module |
| Sample Throughput | ~3 samples/hour |
| Sample Format | Pre-weighed white sugar solids (barcoded) |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | Saccharomat V |
| Product Type | Automatic Polarimeter |
| Temperature Control | Yes (external or Peltier-based) |
| Digital Display | Yes |
| Light Source | LED |
| Measurement Range | −35 to +105 °Z |
| Measurement Resolution | 0.01 °Z |
| Accuracy | ±0.01 °Z |
| Photometric Sensitivity | up to OD 5 |
| Response Time | ~4 s |
| Wavelength Options | 587.6 nm (D-line), 882.6 nm (NIR), or dual-wavelength configuration |
| Temperature Control Range (with thermostatted cell) | 18–40 °C |
| Temperature Accuracy (with T-Cell) | ±0.03 °C |
| Repeatability | 0.01 °Z |
| Optical Path Length | up to 200 mm |
| Display | 7″ TFT touchscreen (800 × 480 px, 16-bit color) |
| Interfaces | RS232 ×1, USB-A ×4, USB-B ×1, Ethernet ×1, Analog output, optional WLAN/LAN |
| Compliance | GLP/GMP-ready, FDA 21 CFR Part 11–compatible software architecture |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | VariDens |
| Instrument Type | Benchtop Laboratory Digital Density Meter |
| Measurement Principle | Oscillating U-tube (vibrating tube) densitometry |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0005 g/cm³ (VariDens C), ±0.00005 g/cm³ (VariDens B) |
| Density Repeatability | ±0.0002 g/cm³ (VariDens C), ±0.00002 g/cm³ (VariDens B) |
| Density Resolution | 0.0001 g/cm³ (VariDens C), 0.00001 g/cm³ (VariDens B) |
| Temperature Control Range | 10–95 °C (Peltier-based electronic thermostating) |
| Temperature Accuracy | ±0.05 °C (VariDens C), ±0.03 °C (VariDens B) |
| Temperature Repeatability | ±0.02 °C (VariDens C), ±0.01 °C (VariDens B) |
| Temperature Resolution | 0.01 °C (VariDens C), 0.001 °C (VariDens B) |
| Pressure Rating | 0–10 bar (0–145 psi) |
| Measurement Time | <30 s per sample |
| Bubble Detection | Automatic dual-mode (optical + electronic) |
| Display | 7" color TFT touchscreen |
| Interfaces | SuH-Connector, RS232 serial, 2× USB, Ethernet, optional WLAN |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | VariPol |
| Product Type | Automated Polarimeter |
| Temperature Control | Peltier-regulated |
| Display | Digital Touchscreen |
| Light Source | LED with Interference Filter |
| Temperature Range | 10–40 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Optical Rotation Accuracy | ±0.01° (VariPol C), ±0.005° (VariPol B) |
| Optical Rotation Resolution | 0.001° |
| Repeatability | ±0.01° (VariPol C), ±0.005° (VariPol B) |
| Wavelength | Standard 589 nm (Na-D line), customizable between 365–882 nm |
| Measurement Time | 6–8 s |
| Optical Path Length Compatibility | Up to 100 mm |
| Detector Dynamic Range | OD 3 |
| Interface Options | 3× USB, 1× RS-232, 1× Ethernet (LAN), optional Modbus, CAN bus, WLAN |
| Dimensions | 430 × 300 × 160 mm (W × D × H) |
| Compliance | 21 CFR Part 11, USP <781>, Ph. Eur. 2.2.7, JP 2.03 |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | VariRef A / B / C |
| Product Type | Inline Refractometer |
| Temperature Control | Dual-isolated Peltier system |
| Digital Display | 5" or 7" capacitive touchscreen (800 × 480 px, 16-bit color) |
| Measurement Range | 1.320000–1.580000 RI / 100% Brix (VariRef A) |
| Accuracy | ±0.00002 RI / ±0.02% Brix |
| Resolution | 0.00001 RI / 0.01% Brix |
| Repeatability | ±0.00001 RI / ±0.01% Brix |
| Temperature Control Range | +5°C to +100°C (VariRef B, customizable) |
| Temperature Accuracy | ±0.03°C |
| Prism Material | Sapphire (A & C), Sapphire/YAG (B) |
| Light Source | LED with integrated 589 nm interference filter |
| Compliance | ASTM D1218, ISO 2160, USP <781>, Ph. Eur. 2.2.12, ICUMSA Methods GS2/3-13, AOAC 932.12, DIN 51757, FDA 21 CFR Part 11 (software-enabled), GLP/GMP audit trail support |