SciAps
Filter
Showing all 3 results
| Brand | SciAps |
|---|---|
| Origin | USA |
| Model | X-200 |
| Application | Handheld/Portable |
| Element Range | Pb, Hg, Cd, Br, Cr |
| Detector | 20 mm² Silicon Drift Detector (SDD), 135 eV FWHM resolution at 5.95 keV Mn Kα line |
| Excitation Source | Rh anode (6–40 kV, 200 µA) for alloy analysis |
| Weight | 1.5 kg (3.3 lbs) with battery |
| Display | 5-inch color capacitive touchscreen |
| Operating Temperature | −4 °C to +54 °C (25 °F to 130 °F) at 10% duty cycle |
| Certifications | CE, RoHS, US FDA Registered, Canada RED Act compliant |
| Brand | SciAps |
|---|---|
| Origin | USA |
| Model | X-550 |
| Detector | 20 mm² Silicon Drift Detector (SDD), 140 eV FWHM resolution at 5.95 keV Mn Kα |
| Excitation Source | Rh anode (40 kV / 200 µA for alloys |
| Elemental Range | Standard 32 elements (Mg–U), configurable per application |
| Sample Form | Solid, powdered, or coated surfaces (non-destructive) |
| Weight | 1.35 kg (2.98 lb) with battery |
| Dimensions | 216 × 241 × 61 mm (8.5 × 9.5 × 2.4 in) |
| Display | 2.7″ color capacitive touchscreen, sunlight-readable |
| Processor | 1.2 GHz quad-core ARM Cortex-A53 (64/32-bit), 2 GB LP-DDR3 RAM, 16 GB eMMC storage |
| Battery | Rechargeable Li-ion, hot-swappable (≤60 s swap time) |
| Regulatory Compliance | CE, RoHS, US FDA 21 CFR Part 820 registered, ISED Canada RED compliant |
| Operating Temperature | –4 °C to 54 °C (25 °F to 130 °F) at 10% duty cycle |
| Calibration Method | Fundamental Parameters (FP) with optional Compton normalization and empirical calibration |
| Filter Wheel | 4-position motorized filter wheel for beam optimization |
| Pulse Processor | 12-bit, 80 MSPS digitization rate, 8K-channel MCA, FPGA-based digital pulse shaping (20 ns – 24 µs peaking time) |
| Software | SciAps ProfileBuilder for library management and method development |
| Applications | Alloy PMI, geochemical exploration, environmental soil screening (EPA Method 6200), RoHS/Br/Cl compliance, catalyst analysis, precious metals assay, lead-based paint (HUD), and empirical custom analysis |
| Brand | SciAps |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Z-903 |
| Instrument Type | Handheld |
| Integration | Fully Integrated |
| Spectral Range | 190–950 nm |
| Detection Capability | H to U (All Elements) |
| Weight | 1.97 kg (4.35 lb) |
| Dimensions | 273 × 73 × 219 mm (10.75 × 2.875 × 8.625 in) |
| Operating System | Android™ (ARM Quad-Core Cortex-A53, 1.2 GHz) |
| Memory | 2 GB LPDDR3 RAM + 16 GB eMMC internal storage |
| Data Storage | 32 GB microSD card |
| Display | 3.5-inch high-brightness color touchscreen (rear-mounted) |
| Laser Class | Class 3B |
| Safety Compliance | CE, RoHS, US FDA Registered |
| Environmental Control | Integrated Opti-Purge™ argon purge system |
| Calibration Reference | Onboard 316 stainless steel validation standard |
| Grade Libraries | >500 preloaded alloy/geochemical libraries, user-editable and multi-library support |
| Connectivity | Wi-Fi (802.11b/g/n), Bluetooth BR/EDR + BLE, GPS, USB-C |
| Power | Rechargeable Li-ion battery (internal & external charging), AC adapter compatible |
| Sample Alignment | Integrated coaxial laser targeting + dual-camera system (wide-field + macro) |
| Drift Correction | Onboard auto-drift correction using factory or user-defined reference materials |
| Software | SciAps AnalyzAR™ suite with spectral comparison, quantitative calibration curve generation, and full parameter control (laser firing pattern, spectrometer integration time, lens cleaning protocol) |