Shanda
Filter
Showing all 19 results
| Brand | Shanda |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FERRITE-CHECK 140 |
| Price | USD 4,200 (approx.) |
| Measurement Range | 1–100 Fe% / 1–140 Ferrite Number (FN) |
| Accuracy | ±<5% of reading |
| Operating Temperature | 0–50 °C |
| Calibration Standards | Three NIST-traceable ferrite reference standards |
| Power Supply | Rechargeable lithium-ion battery |
| Compliance | DIN EN ISO 8249:2018 |
| Brand | Shanda |
|---|---|
| Model | SD-0SB |
| Origin | Shandong, China |
| Heating Power | 1.2 kW |
| Max Temperature | 400 °C |
| Temperature Uniformity | ±1 °C |
| Display | Intelligent Digital LED |
| Heating Surface | 300 × 200 mm |
| Panel Thickness | 12 mm |
| Voltage | 220 V AC |
| Control Accuracy | ±0.1 °C (PID-controlled) |
| Insulation | Dual-layer (air gap + ceramic fiber) |
| Brand | Shanda |
|---|---|
| Model | SD-2TA |
| Type | Manual Hydraulic Powder Press |
| Maximum Pressure | 2 Ton (25 MPa) |
| Piston Diameter | Ø32 mm |
| Max Piston Stroke | <30 mm |
| Pressure Gauge | Analog Dual-Scale (MPa & Ton), Accuracy: ±1 MPa |
| Pressure Stability | ≤1 MPa/10 min |
| Worktable Diameter | Ø70 mm |
| Working Space | 90 × 120 mm |
| Overall Dimensions | 210 × 170 × 370 mm |
| Net Weight | ~11 kg |
| Compliance | Designed for GLP-aligned lab environments |
| Brand | Shanda |
|---|---|
| Origin | Shandong, China |
| Model | SD-CL9 |
| Measurement Principle | Coulometric Titration (per GB/T 214–2007) |
| Sample Types | Coal, Coke, Activated Carbon, Petroleum Coke |
| Temperature Control | Microprocessor-regulated High-Temperature Furnace (up to 1150 °C) |
| Electrolytic Cell | Integrated Dual-Platinum Electrode Cell |
| Display | 7-inch TFT LCD Touch Interface |
| Power Supply | AC (220 ± 22) V, 50 Hz |
| Max Power Consumption | ≤3 kW |
| Safety Features | Automatic Silicon Carbide Tube Protection, Overcurrent Protection, Real-time Temperature Compensation |
| Data Management | Non-volatile Memory Storage, USB Export, Print Support (via RS232 or USB thermal printer) |
| Compliance | Designed to meet requirements of GB/T 214–2007, ASTM D3177, ISO 4293, and supports GLP-compliant audit trails when paired with optional PC software |
| Brand | Shanda |
|---|---|
| Model | SD-FP7450 |
| Origin | Shandong, China |
| Detection Elements | K, Na, Li, Ca, Ba |
| Number of Channels | 5 |
| Measurement Range | 0.000–999.9 / 0–65535 (arbitrary units) |
| Detection Limits (mmol/L) | K ≤ 0.004, Na ≤ 0.008, Li ≤ 0.015, Ca ≤ 0.050, Ba ≤ 0.044 |
| Linearity Error (mmol/L) | K ≤ 0.005, Na ≤ 0.03, Li ≤ 0.021, Ca ≤ 0.075, Ba ≤ 0.066 |
| Response Time | ≤ 8 s |
| Nebulization Rate | < 6 mL/min |
| Stability | ≤ 3% RSD over 15 s |
| Repeatability | ≤ 3% RSD |
| Display | 7-inch capacitive color touchscreen |
| Output | Concentration values and relative emission intensity |
| Data Output | Built-in Bluetooth thermal printer, USB interface, optional PC software |
| Graphical Display | Real-time calibration curve and signal trend plotting |
| Compliance | Designed for routine quantitative analysis in accordance with ISO 11097:2010 (Water quality — Determination of sodium and potassium — Flame photometric method) and ASTM D1293 (Standard Test Methods for Electrical Conductivity and pH of Water) |
| Brand | Shanda |
|---|---|
| Model | SD-FS800Z |
| Measurement Principle | Closed-path infrared gas analysis (IRGA) with dual-wavelength CO₂ sensor |
| CO₂ Range | 0–2000 ppm |
| CO₂ Resolution | ≤0.1 ppm |
| CO₂ Accuracy | ±1.5% of reading (temperature-compensated) |
| Air Temperature Range | −20 °C to +60 °C |
| Relative Humidity Range | 0–85% RH (non-condensing) |
| Leaf Temperature Sensor | Thermistor, ±0.2 °C accuracy |
| PAR (Photosynthetically Active Radiation) Sensor | Silicon photodiode, 0–3000 µmol·m⁻²·s⁻¹, ±5% |
| Flow Rate Control | Adjustable 0–1.0 L·min⁻¹, stability ±1% FS |
| Power Supply | Rechargeable 8.4 V DC Li-ion battery, 15 h continuous operation (no external light source) |
| Display | 3.5″ TFT color LCD, 800×480 resolution |
| Data Storage | Internal 16 GB flash memory (expandable to 32 GB) |
| Interface | USB 2.0 for data export |
| Dimensions | 260 × 260 × 130 mm |
| Weight | 3.25 kg |
| Leaf Chamber Standard Size | 55 × 20 mm (customizable) |
| Operating Environment | −20 °C to +60 °C, 0–85% RH |
| Brand | Shanda |
|---|---|
| Model | SD-FSX |
| Origin | Shandong, China |
| Category | Rubber & Plastic Industry–Specific Instrument |
| Compliance | GB/T 6030–2006 |
| Imaging Sensor | 5 MP CMOS |
| Resolution Options | 640×480, 1024×768, 1280×1024, 2592×1944 |
| Interface | USB 2.0 |
| Calibration | Integrated micrometer scale with pixel-to-µm mapping |
| Output Formats | PDF, PNG/JPEG, Excel (.xlsx) |
| Software Compatibility | Windows XP/7/10 (32/64-bit) |
| Image Segmentation Modes | Automated thresholding + manual ROI selection |
| Standard Reference Libraries | ISO-aligned carbon black dispersion image library + user-customizable library |
| Data Export | Particle count, equivalent circular diameter (µm), projected area (µm²), grayscale histogram, particle size distribution curve, dispersion rating (0–10 scale per GB/T 6030) |
| Brand | Shanda |
|---|---|
| Model | SD-GCT-28A |
| Sample Capacity | 28 positions |
| Power Supply | 220–230 V, 50 Hz |
| Operating Temperature Range | 5–40 °C |
| Relative Humidity | 10–85% |
| Temperature Control Accuracy | 25 °C ± 2 °C |
| Software | PC-based workstation software with real-time hardware monitoring, error code display, Excel export, color-coded batch labeling, and historical data retrieval |
| Optional Accessories | Rice sample preparation mill, dedicated PC, water-cooling unit |
| Brand | Shanda |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Model | SD-HQMG |
| Price | USD 1,390 (FOB) |
| Function Type | Multi-analyte Detection Platform |
| Sample Scope | Universal for Cereals, Oilseeds, Feed Matrices, and Processed Food Commodities |
| Main Controller | ARM Cortex-A7 |
| Detection Channels | ≥12 independent optical channels |
| Display | 10.1-inch HD vertical capacitive touchscreen (1280×800) |
| Communication Interfaces | Integrated Wi-Fi (802.11 b/g/n), RJ45 Ethernet port, USB 2.0 host/device |
| Power Supply | DC 12 V — compatible with vehicle power outlets |
| Data Storage | Internal eMMC (16 GB) + USB flash drive support (FAT32/exFAT) |
| Dimensions (W×D×H) | 430 × 350 × 190 mm |
| Net Weight | 5.1 kg |
| Light Source | Precision imported quad-wavelength cold LED source (450 nm, 520 nm, 590 nm, 630 nm) |
| Processor | Rockchip RK3288 (ARM Cortex-A17 quad-core, 1.8 GHz) |
| Brand | Shanda |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SD-L2 |
| Sample Capacity | Multi-sample simultaneous measurement |
| Instrument Type | Heat-Flow DSC |
| Temperature Range | −100 °C to 600 °C |
| Programmable Temperature Control | Heating, Isothermal, Cooling |
| Heating/Cooling Rate | 0.1–100 K/min |
| Scan Modes | Dynamic heating, dynamic cooling, isothermal hold |
| Temperature Accuracy | ±0.01 °C (typical, calibrated per ASTM E794 & ISO 11357-1) |
| Baseline Stability | <0.5 µW over 30 min at 50 °C |
| Sensor Resolution | 0.01 µW |
| Temperature Sensing | Dual independent platinum RTD sensors (furnace + sample) |
| Control Algorithm | Adaptive dynamic PID with FTC/STC dual-mode selection |
| Data Acquisition | 1–10 Hz user-selectable sampling rate |
| Communication Interface | USB 2.0 with auto-reconnect protocol |
| Atmosphere Control | Dual independent gas channels (N₂, O₂, Ar, air), software-switched via solenoid valves |
| Calibration Standards | Indium, Zinc, Tin, and Sapphire (per ISO 11357-2) |
| Brand | Shanda |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | General Distributor |
| Country of Origin | China |
| Model | SD-MS04 |
| Price | USD 630 (approx.) |
| Touchscreen | 5-inch color capacitive touchscreen |
| Operating System | Android-based embedded UI |
| Temperature Control | PID algorithm |
| Temp Range | Ambient to 260 °C |
| Temp Accuracy | ±1 °C |
| Temp Segments | 1–5 programmable segments |
| Heating Method | Quartz infrared heating tubes |
| Graphite Block | High-density graphite core with PTFE coating |
| Well Dimensions | Ø30 mm × 160 mm depth |
| External Dimensions | 387 mm (W) × 371 mm (D) × 168 mm (H) |
| Power Supply | AC 220 V, 50 ±1 Hz |
| Rated Power | 1000 W |
| Brand | Shanda |
|---|---|
| Origin | Shandong, China |
| Model | SD-ND600 |
| Wavelength Range | 185–910 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Resolution | ≤1.8 nm (FWHM at Hg 546 nm) |
| Absorbance Accuracy | ±1% (7.332 Abs at 260 nm) |
| Absorbance Precision | 0.002 Abs |
| Sample Volume | 0.5–2.0 µL |
| Pathlength Options | 0.02, 0.05, 0.1, 0.5, and 1.0 mm (automatically selected) |
| Measurement Time | ≤5 s per sample |
| Cuvette Mode OD600 Range | 0–4 A |
| dsDNA Quantitation Range | 2–38,880 ng/µL |
| BSA Protein Range | 0.06–820 mg/mL |
| Light Source | Pulsed Xenon Lamp (10-year lifetime) |
| Detector | 3648-pixel Linear CCD Array |
| Display | 7-inch Capacitive Touchscreen (Android OS) |
| Data Export | USB flash drive, SD-RAM card |
| Optional Fluorescence Module | Ex 460 nm / Em 525 nm |
| Dimensions (W×D×H) | 270 × 210 × 196 mm |
| Weight | 3.5 kg |
| Brand | Shanda |
|---|---|
| Model | SD-NIR-AC |
| Housing Material | 304 Stainless Steel |
| Measurement Principle | Near-Infrared Reflectance Spectroscopy (NIRS) at Water-Absorbing Wavelengths (e.g., 1450 nm, 1940 nm) |
| Moisture Range | 0–100% w/w |
| Accuracy | ±0.2% w/w (under stable composition conditions) |
| Temperature Compensation | Built-in, automatic |
| Optical Path | Non-contact, reflective configuration |
| Spot Diameter | 60–75 mm |
| Measurement Height | 350 mm ± 100 mm |
| Optical Window | High-borosilicate quartz glass |
| Light Source | Imported high-stability NIR LED/Laser |
| Signal Processing | Full digital signal processing with adaptive digital filtering |
| Output Interfaces | RS485, 4–20 mA, RS232, Ethernet (LAN), LoRa wireless |
| Power Supply | 220 VAC / 50 Hz |
| Power Consumption | 60 W |
| Operating Environment | −40 °C to +70 °C, 5–95% RH (non-condensing) |
| Ingress Protection | IP65 |
| Optional Features | Integrated temperature sensing (0–500 °C), multi-channel spectral acquisition (50 channels) |
| Brand | Shanda |
|---|---|
| Model | SD-PE-T |
| Type | Electronic Farinograph |
| Power Supply | 220 V AC, 50 Hz |
| Motor Power | 300 W |
| Rotational Speed Range | 2–200 ±1 rpm (adjustable, real-time display) |
| Speed Ratio (Fast/Slow Blades) | 1.5:1 |
| Torque Measurement Range | 0–20 N·m |
| Torque Sensor Accuracy | ≤0.3% FS |
| Bowl Capacity | 300 g |
| Torque Unit Calibration | (9.8 ± 0.2) mN·m per Farinograph Unit (FU) |
| Measuring Range | 0–2000 FU |
| Water Addition Accuracy | ±0.2 mL (for 300 g dough) |
| Water Bath Pressure | ≤340 mbar |
| Water Circulation Flow Rate | 15 L/min (auto-fill enabled) |
| Dough Temperature Control | 30 ± 0.2 °C (PID-controlled water jacket) |
| Temperature Setting Range (Incubation Chamber) | 20–50 °C |
| Chamber Temperature Stability | ±0.2 °C |
| Chamber Power | 1200 W |
| Chamber Display | 5-inch embedded LCD touch screen |
| Safety Features | Overload protection (bowl), mechanical/electrical interlock (mixer), real-time heating element monitoring, automatic alarm on anomaly |
| Material | Imported stainless steel (bowl & blades), corrosion-resistant surface-treated structural components |
| Compliance Standards | ICC 115/1, AACC 54-21, ISO 5530-1, GB/T 14614 |
| Data Handling | Multi-file curve overlay (unlimited), custom color/name assignment, cross-brand farinogram import (legacy formats), real-time interruption & interim calculation, encrypted storage, export to CSV/Excel, GLP-compliant audit trail (via Smart Pbox integration) |
| Software | Windows 7/10 native, perpetual license, free lifetime updates |
| Service | Annual certified standard-sample calibration (with CNAS-accredited reference material certificate), two free post-warranty calibration & maintenance visits (Years 2–3), third-party performance evaluation report issued by national metrology institute |
| Connectivity | Real-time multi-terminal data viewing (requires Smart Pbox gateway) |
| Brand | Shanda |
|---|---|
| Model | SD-QY04 |
| Type | Manual Core Sampler |
| Origin | Shandong, China |
| Sampling Depth | Up to 2 m |
| Standard Configuration | Four interchangeable coring bits (clay, loam, sand, peat), two 100 cm extension rods, one 50 cm extension rod, T-handle, soil scraper, dual wrenches, 3 m steel tape measure, protective gloves, aluminum carrying case |
| Brand | Shanda |
|---|---|
| Model | SD-RXS |
| Origin | Shandong, China |
| Measurement Principle | Compression-based Gravimetric Method (NY/T 821–2004) |
| Force Range | 0–3000 N |
| Resolution | 0.1 N |
| Accuracy | ±1% FS |
| Compression Speed | 1–300 mm/min |
| Dwell Time | 1–3600 s |
| Deformation Range | 1–70 mm |
| Platen Diameter | 110 mm |
| Parallelism | <0.05 mm |
| Dimensions | 450 × 450 × 680 mm |
| Weight | ~45 kg |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Shanda |
|---|---|
| Model | SD-SW |
| Instrument Type | Multifunctional Soil Analyzer |
| Display | Large Backlit Chinese LCD |
| Power Supply | Rechargeable Lithium Battery or AC Adapter |
| Dimensions | 204 × 100 × 36 mm |
| Measurement Principle | Frequency Domain Reflectometry (FDR) |
| Soil Volumetric Water Content Range | 0–100% (m³/m³) |
| Accuracy | ±2% (0–50%), ±3% (50–100%) |
| Resolution | 0.1% (moisture), 0.1°C (temperature) |
| Temp. Range | −40 to +120°C |
| Temp. Accuracy | ±0.2°C |
| Response Time | <1 s |
| Stabilization Time | ~10 s |
| Sensing Volume | 90% influence within a 3 cm diameter × 6 cm length cylinder centered on probe |
| Communication | USB 2.0 |
| Data Logging | Manual/Automatic (configurable interval) |
| Optional Connectivity | 4G module for cloud upload to web-based agricultural platform |
| Software | Free PC-based data management suite (Excel export, curve plotting, GLP-compliant audit trail) |
| Brand | Shanda |
|---|---|
| Model | SD-XB |
| Instrument Type | Multi-Function Microplate Washer |
| Wash Head Configuration | 8-channel or 12-channel dual-row removable wash head |
| Wash Fluid Channels | 1 standard (up to 4 optional) |
| Soaking Time Range | 0–24 h (hh:mm:ss adjustable) |
| Wash Cycles | 0–99 |
| Residual Volume per Well | ≤1 µL |
| Plate Compatibility | Standard 96-well flat-bottom, U-bottom, V-bottom, and C-bottom microplates |
| Wash Row Selection | 1–12 rows (including skip-row configuration) |
| Liquid Delivery Pressure | 5 adjustable levels |
| Aspiration/Dispense Time | 0–9 s (extendable) |
| Plate Shaking | 0–24 h (hh:mm:ss), 3 intensity levels |
| Cleaning Modes | Center wash, dual-point wash |
| Program Storage | 200 user-defined protocols + 20 pre-stored plate profiles |
| Liquid Level Monitoring | Waste bottle full-level alarm |
| Display & Interface | 5.6-inch color TFT touchscreen, 7×24 h continuous operation with auto power-saving mode |
| Power Input | AC 100–240 V, 50/60 Hz |
| Dimensions (L×W×H) | 380 × 330 × 222 mm |
| Net Weight | ~9 kg |
| Reagent Bottles | Three 2 L bottles included |
| Brand | Shanda |
|---|---|
| Model | SD-Z08P |
| Origin | Shandong, China |
| Regulatory Approval | Approved by Ministry of Agriculture and Rural Affairs (MARA), P.R. China |
| Detection Principle | Real-Time Fluorescent Quantitative Polymerase Chain Reaction (qPCR) |
| Target Analyte | African Swine Fever Virus (ASFV) Genomic DNA |
| Compatible Assays | MARA-registered ASFV fluorescent qPCR kits (e.g., SD-ASF-KIT series) |
| Operational Modes | Laboratory-based and field-deployable (battery-supported operation optional) |
| Throughput | 8 samples per run |
| Thermal Cycling Range | 4–105 °C |
| Fluorescence Channels | 4-channel excitation/emission detection (FAM, HEX/VIC, ROX, CY5) |
| Data Output | Ct values, amplification curves, qualitative/quantitative reports compliant with MARA diagnostic guidelines |