Animal Husbandry Specialized Instruments
Filter
Showing 1–30 of 36 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A220 |
| Pricing | Available Upon Request |
| Sample Capacity | 24 positions |
| Throughput | ≥96 samples per day |
| Operating Temperature | 100 °C |
| Power Supply | 220 V, 50/60 Hz, 1500 W |
| Weight | 20 kg (45 lbs) |
| Filter Bag Pore Size | 30 µm |
| Chemical Resistance | Compatible with 75% sulfuric acid and neutral/basic detergents |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | FBS6 |
| Price Range | USD 2,700 – 6,800 (FOB Hamburg) |
| Heating Capacity | 1 position |
| Sample Throughput | 6 samples per run |
| Max Temperature | 425 °C |
| Power Supply | 230 V AC, 50–60 Hz |
| Power Consumption | 450 W |
| Dimensions (W×D×H) | 250 × 230 × 600 mm |
| Net Weight | 12 kg |
| Method Principle | Filter Bag-Based Acid-Base Digestion per AOAC 962.09 and ISO 6865 |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | FT12 |
| Price Range | USD 25,000 – 50,000 |
| Sample Capacity | 1–12 samples per batch |
| Heating System | Crystalline ceramic heater |
| Programmable Methods | 10 |
| Reagent Dispensing | Automated acid/alkali/water/waste handling |
| Filtration | Pneumatically controlled FibreBag® filtration |
| Safety Features | Closed-system operation, audible/visual error alerts |
| Cooling Water Requirement | 5 L/min (on-demand) |
| Power Supply | 230 V AC, 50 Hz |
| Power Consumption | 1900 W |
| Dimensions | 330 × 650 × 860 mm |
| Weight | 42 kg |
| Brand | Distell |
|---|---|
| Origin | United Kingdom |
| Model | FFM-992 |
| Measurement Principle | Microwave Dielectric Sensing (2.0 GHz ±20 MHz, 2 mW) |
| Sensor Dimensions | 195 × 100 × 40 mm (housing), 80 × 25 × 10 mm (electrode probe) |
| Electrode Material | Carbon outer electrode, stainless steel inner electrode |
| Display | 2-line × 12-character LCD |
| Processor | Embedded microprocessor with firmware supporting up to 80 user-defined calibrations |
| Battery | Rechargeable NiMH pack (integrated, no external connectors) |
| Weight | 725 g (including battery) |
| Enclosure Material | ABS plastic |
| Ingress Protection | IP65 |
| Fat/Oil Measurement Range | 1–80% (w/w, species-dependent) |
| Preloaded Calibrations | >60 standard marine and farmed fish species |
| Data Modes | Real-time measurement mode & research mode with audit-ready logging |
| Software | PC-based data management suite for batch analysis, statistical reporting, and calibration file export |
| Compliance | Designed for GLP-compliant field and lab use |
| Brand | Distell |
|---|---|
| Origin | United Kingdom |
| Model | MFM-992/1092 |
| Sensor Type | Microstrip Transmission Microwave |
| Frequency | 2.0 GHz (±20 MHz) |
| Microwave Power | 2 mW |
| Display | LCD, 2×12 characters |
| Housing Material | Stainless steel & PTFE sensor head |
| IP Rating | IP65 |
| Dimensions | 195 mm × 100 mm × 40 mm |
| Weight | 725 g (with NiMH battery) |
| Onboard Memory | Up to 80 calibration sets |
| Data Interface | RS-232 serial port for real-time and historical data transfer |
| Software | Dedicated FatMeter Data Management Suite |
| Power Supply | 9 V DC, 1.2 A (via universal AC adapter: 110 V AC, 50–60 Hz) |
| Battery | Rechargeable NiMH |
| Brand | Fengtu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | FT-P108 |
| Price | USD 4,500 (FOB Qingdao) |
| Sample Capacity | 8 × 0.2 mL tubes |
| Temperature Range | 4–99 °C |
| Thermal Accuracy | ±0.1 °C |
| Temperature Uniformity | ≤±0.25 °C |
| Max Heating/Cooling Rate | 5.5 / 5.0 °C/s |
| Excitation Wavelength | 460–480 nm |
| Emission Detection Range | 505–525 nm |
| Sensitivity | Single-copy DNA detection |
| Dynamic Range | 10¹–10¹⁰ copies |
| Linearity (R²) | ≥0.999 |
| Inter-well CV | <1% |
| Supported Chemistries | SYBR Green I, FAM |
| Optical System | High-power LED + Photodiode detector |
| Control Interface | Built-in Android touchscreen + PC software |
| Data Export | CSV, PDF, Excel |
| Compliance | CE-marked, ISO 13485-aligned design principles |
| Brand | Fengtu |
|---|---|
| Origin | Shandong, China |
| Model | FT-ZW108 |
| Channel Configuration | Single-channel (8-well) |
| Temperature Range | 4–99 °C |
| Thermal Accuracy | ±0.1 °C |
| Temperature Uniformity | ≤±0.25 °C |
| Max Heating/Cooling Rate | 5.5 °C/s / 5 °C/s |
| Excitation Wavelength | 460–480 nm |
| Emission Detection Range | 505–525 nm |
| Sensitivity | Single-copy DNA detection |
| Dynamic Range | 10¹–10¹⁰ copies |
| Linearity (R²) | ≥0.999 |
| Inter-well CV | <1% |
| Supported Chemistries | FAM, SYBR Green I |
| Sample Format | 0.2 mL tubes or 8-tube strips |
| Power Supply | 220 V AC, max 550 W |
| Dimensions | 320 × 314 × 206 mm |
| Weight | 4.2 kg |
| Operating System | Embedded Android (dual-language UI) |
| Data Export | CSV, PDF, Excel |
| Connectivity | USB, Wi-Fi |
| Noise Level | ≤60 dB(A) |
| Brand | Fujihira Industrial Co., Ltd. / FHK |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 001 |
| Price | Upon Request |
| Measurement Range | 0–5.0 kgf (0–50.0 N, 0–10.0 lbf) |
| Display Resolution | 0.001 kgf |
| Sampling Rate | 1,000 Hz |
| Peak Hold Function | Yes (patented stop-on-fracture mechanism) |
| Output Interfaces | RS-232C, USB |
| Power Supply | AC 100 V |
| Net Weight | 6.5 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | F2000 |
| Sample Capacity | 24+ positions per batch |
| Temperature Control Accuracy | ±0.1°C |
| Repeatability | ≤0.5% RSD |
| Daily Throughput | ≥96 samples (4 batches) |
| Power Supply | AC 220±10 V, 50±1 Hz |
| Rated Power | 2000 W |
| Dimensions (L×W×H) | 520 × 450 × 510 mm |
| Net Weight | 52 kg |
| Compliance | GB/T 6434-2006, GB/T 20805-2006, GB/T 20806-2006, GB/T 5515-2008, GB/T 8310-2013, GB/T 5009.10-2003 |
| Brand | Hanon |
|---|---|
| Model | F800 |
| Origin | Shandong, China |
| Type | Semi-Automatic Fiber Analyzer |
| Compliance | GB/T 5515, GB/T 6434 |
| Sample Capacity | 6 samples/batch |
| Sample Weight Range | 0.5–3 g |
| Detection Range | 0.1–100% |
| Repeatability | ≤0.4% (for crude fiber <10%), ≤1% (for crude fiber ≥10%) |
| Heating Method | Integrated Infrared Heating |
| Preheating Time (Distilled Water) | 10–12 min |
| Boiling Time | 13–15 min |
| Rated Power | 2.2 kW |
| Voltage/Frequency | 220 VAC ±10%, 50 Hz |
| Dimensions | 776 × 476 × 644 mm |
| Optional Accessory | F800-B Cold Extraction Unit |
| Brand | Hengmei |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HM-CXW |
| Price | USD 3,500 (FOB Qingdao) |
| Detection Range | 0–100% |
| Sample Mass | 0.5–3.0 g |
| Batch Capacity | 6 samples |
| Temperature Control Accuracy | ±0.1 °C |
| Repeatability | ≤0.4% (crude fiber <10%) |
| Heating Element | Semi-circular silicon carbide heater |
| Display | 7-inch color TFT touchscreen |
| Liquid Delivery | Programmable, fully automated acid/alkali reagent injection |
| Filtration System | High-suction corrosion-resistant diaphragm pump with integrated back-blow function |
| Safety Features | Overflow prevention logic, dry-run protection, external reagent preheating reservoir |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Total Power | 1500 W (main unit) + 1200 W (digestion block) |
| Dimensions (W×D×H) | 620 × 440 × 655 mm |
| Weight | 45 kg |
| Brand | Hongweiliangzi |
|---|---|
| Origin | Shandong, China |
| Model | HW-CXW |
| Detection Range | 0–100% |
| Sample Weight | 0.5–3.0 g |
| Batch Capacity | 6 samples |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Element | Semi-circular Silicon Carbide Heater |
| Repeatability | ≤0.4% (crude fiber <10%), ≤1% (crude fiber ≥10%) |
| Display | 7-inch Color Touchscreen |
| Liquid Delivery | Programmable Automatic Dispensing |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Total Power | 1500 W (main unit) + 1200 W (anti-dry-boil digestion vessel) |
| Dimensions | 620 × 440 × 655 mm |
| Weight | 45 kg |
| Brand | Hongweiliangzi |
|---|---|
| Model | HW-DWYB |
| Origin | Shandong, China |
| Power Supply | 12 V DC |
| Display | 7-inch capacitive touchscreen |
| Data Storage | 200,000 test records |
| Connectivity | Wi-Fi, USB 2.0 |
| Printer | Integrated thermal printer |
| Dimensions (L×W×H) | 550 × 245 × 375 mm |
| Weight | 6.8 kg |
| Regulatory Compliance | Meets GB/T 27404–2008 (Laboratory Quality Control for Food Microbiology), compatible with national veterinary residue limit standards (e.g., NY 468–2001, GB 29690–2013) |
| Brand | OPISIS |
|---|---|
| Origin | Sweden |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | FB-120 |
| Price | Upon Request |
| Capacity | 6 samples per batch |
| Dimensions (W×H×D) | 655 × 325 × 475 mm |
| Weight | 25 kg |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80 % RH |
| Voltage | 190–240 VAC, 50–60 Hz |
| Max. Power Consumption | 2000 W |
| Fiber Method | Crude Fiber (CF) per Weende and AOAC/ISO-compliant protocols |
| Hydrolysis Compatibility | Samples with fat content 0.1–100 %, sample mass 0.5–3 g |
| Brand | Opsis |
|---|---|
| Origin | Sweden |
| Model | FB-300 |
| Sample Capacity | 27 per batch |
| Throughput | 108 CF / 135 NDF / 162 ADF samples per day |
| Sample Mass Range | 0.1–2.0 g |
| Measurement Range | 0–100% |
| Repeatability | ≤ 0.5% |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Accuracy | ±0.1 °C |
| Display | Color LCD touchscreen with bilingual (EN/CN) interface |
| Programmable Methods | Up to 50 user-defined protocols |
| Compliance | AOAC 978.10, AOAC 2002.04, AOAC 962.09, AACC 32–25, USP <281>, GB/T 6434–2006, GB/T 20806–2006, AAFCO Official Methods |
| Safety Systems | Dual liquid-level sensors, real-time temperature & pressure monitoring, mechanical pressure relief valve, lid interlock sensor |
| Software Integration | LabConnect LIMS-ready, optional balance & barcode scanner interface |
| Power Supply | 230 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 720 × 650 × 780 mm |
| Weight | 85 kg |
| Brand | Opsis |
|---|---|
| Origin | Sweden |
| Model | FB-310 |
| Sample Capacity | 27 per batch |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Repeatability | ≤0.5% RSD |
| Measurement Range | 0–100% |
| Display | Color LCD touchscreen with bilingual (English/Chinese) interface |
| Programmable Methods | Up to 50 user-defined protocols |
| Reagent Ports | 4 independent external connections (acid, base, neutral detergent, acid detergent) + dedicated amylase reservoir |
| Compliance | AOAC 978.10, AOAC 2002.04, AOAC 962.09, AACC 32–25, USP <281>, GB/T 6434–2006, GB/T 20806–2006, AAFCO Official Methods |
| Brand | Harold |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Model | LI-II |
| Pricing | Available Upon Request |
| Brand | Shanda |
|---|---|
| Model | SD-Z08P |
| Origin | Shandong, China |
| Regulatory Approval | Approved by Ministry of Agriculture and Rural Affairs (MARA), P.R. China |
| Detection Principle | Real-Time Fluorescent Quantitative Polymerase Chain Reaction (qPCR) |
| Target Analyte | African Swine Fever Virus (ASFV) Genomic DNA |
| Compatible Assays | MARA-registered ASFV fluorescent qPCR kits (e.g., SD-ASF-KIT series) |
| Operational Modes | Laboratory-based and field-deployable (battery-supported operation optional) |
| Throughput | 8 samples per run |
| Thermal Cycling Range | 4–105 °C |
| Fluorescence Channels | 4-channel excitation/emission detection (FAM, HEX/VIC, ROX, CY5) |
| Data Output | Ct values, amplification curves, qualitative/quantitative reports compliant with MARA diagnostic guidelines |
| Brand | Sonnen |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | F20 |
| Pricing | Available Upon Request |
| Measurement Principle | Acid-Base Digestion per National Standards (GB/T 6434, GB/T 5515, GB/T 10378, GB 5009.10) |
| Filtration Technology | Disposable Filter Bag System (Standard Pore Size: 25 µm |
| Optional | 15 µm or 10 µm) |
| Batch Capacity | 1–30 samples/batch |
| Daily Throughput | 90–180 samples |
| Temperature Range | Ambient to 100 °C |
| Sample Mass per Bag | 0.1–5.0 g |
| Temperature Control Accuracy | ±0.1 °C |
| Stirring Mechanism | Patented Intermittent Agitation (15 rpm, 1-min cycle) |
| Repeatability | ≤0.5% RSD |
| Power Supply | AC 220 V / 50 Hz |
| Safety Design | High-pressure sealed digestion chamber, no cooling water required, no internal glass components, lab-bench compatible (no fume hood needed) |
| Brand | Sonnen |
|---|---|
| Model | F22 |
| Application | Crude Fiber, Neutral Detergent Fiber (NDF), Acid Detergent Fiber (ADF), Acid Detergent Lignin (ADL), and Insoluble Dietary Fiber analysis |
| Principle | Standardized acid-base digestion (AOAC 978.10, AOAC 2002.04, ISO 13906, GB/T 6434–2022) |
| Filtration Technology | 25 µm pore-size filter bags (optional 15 µm or 10 µm) |
| Batch Capacity | 30 samples per run |
| Temperature Range | Ambient to 100 °C |
| Sample Mass per Bag | 0.1–5.0 g |
| Repeatability | ≤0.5% RSD |
| Temperature Control Accuracy | ±0.1 °C |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (W×D×H) | 373 × 500 × 450 mm |
| Weight | 25 kg |
| Safety | High-pressure sealed digestion chamber, no cooling water required, no glass components, operational in standard lab environment without fume hood |
| Brand | Tianhe (Shandong Tianhe Instrument Co., Ltd.) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TH-ZW216 |
| Price | USD 4,200 (approx. based on ¥30,000) |
| Sample Capacity | 16 × 0.2 mL tubes or 8-tube strips |
| Reaction Volume | 5–120 µL |
| Temperature Range | 4–99 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity | ±0.1 °C |
| Max. Heating Rate | 7 °C/s |
| Max. Cooling Rate | 5 °C/s |
| Optical Excitation Range | 400–700 nm |
| Detection Channels | 2 (FAM/SYBR Green I and VIC/HEX) |
| Data Acquisition | Full-plate capture in 3 s |
| Thermal Control | Peltier-based with PT1000 sensor and resistive edge compensation |
| Noise Level | <45 dB |
| Touch Interface | Capacitive touchscreen |
| Heat Lid | Auto-pressure-adjusting thermal lid |
| Software | Integrated qPCR analysis suite supporting standard curve quantification, melt curve analysis, ΔΔCt, multi-channel overlay, and baseline/noise threshold adjustment |
| Brand | Tianhe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | TH-ZW108 |
| Price | USD 3,650 (approx.) |
| Sample Capacity | 8 × 0.2 mL tubes |
| Reaction Volume | 5–120 µL |
| Temperature Range | 4–99 °C |
| Max. Heating Rate | 7 °C/s |
| Max. Cooling Rate | 5 °C/s |
| Temp. Uniformity | ≤ ±0.2 °C |
| Temp. Accuracy | ≤ ±0.1 °C |
| Detection Channels | 1 (FAM/SYBR Green I) |
| Excitation Wavelength | 400–700 nm |
| Detection Method | LED excitation + imported photodetector |
| Screen | 7-inch HD capacitive touchscreen |
| Dimensions (L×W×H) | 355 × 200 × 124 mm |
| Weight | 2.5 kg |
| Noise Level | <45 dB |
| Thermal Lid | Auto-pressure-adjusting |
| Data Interface | USB port for import/export |
| Software | Integrated qPCR analysis suite with real-time curve plotting, automatic positive/negative call, GLP-compliant audit trail logging |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Model | TY-ZW216 |
| Detection Principle | Real-Time Fluorescent Quantitative PCR (qPCR) |
| Channel Configuration | Dual-channel (FAM/VIC compatible) |
| Sample Capacity | 16 × 0.2 mL wells (supports single tubes & 8-tube strips) |
| Temperature Range | 4–99 °C |
| Thermal Accuracy | ±0.1 °C |
| Well-to-Well Uniformity | ≤±0.25 °C |
| Max Heating/Cooling Rate | 6 °C/s / 4 °C/s |
| Optical System | Dual high-intensity LED excitation sources (460–480 nm & 525–545 nm), dual photodiode detectors with narrow-band interference filters |
| Sensitivity | Single-copy DNA detection capability |
| Dynamic Range | 10 orders of magnitude (1–10¹⁰ copies/µL) |
| Linearity | R² ≥ 0.999 |
| Reproducibility | CV < 2% (fluorescence), CV < 2% (sample), CV < 3% (precision) |
| Data Output Formats | PDF, XLS, CSV, DOCX |
| Connectivity | USB 2.0, Wi-Fi (optional), Android-based onboard OS |
| Dimensions | 350 × 384 × 184.5 mm |
| Weight | 5.4 kg |
| Power | 220 V AC, max 300 W |
| Operating Environment | 18–35 °C, 0–85% RH (non-condensing) |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Producer |
| Country of Origin | China |
| Model | CXC-06 |
| Price | USD 1,300 (FOB) |
| Sample Capacity | 6 samples per run |
| Repeatability Error | ≤0.4% absolute (for crude fiber content <10%) |
| Total Digestion & Filtration Time | ~100 min (acid digestion: 40 min |
| alkaline digestion | 40 min |
| filtration & washing | ~20 min) |
| Power Supply | AC 220 V / 50 Hz |
| Rated Power | 2800 W |
| Cooling Water Requirement | inlet water temperature <20 °C |
| Dimensions (W×D×H) | 670 mm × 450 mm × 670 mm |
| Net Weight | 30 kg |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CXC-06 |
| Power | 2800 W |
| Voltage/Frequency | AC 220 V / 50 Hz |
| Dimensions (W×D×H) | 670 × 450 × 670 mm |
| Weight | 30 kg |
| Sample Capacity | 6 samples per run |
| Analyte | Crude fiber content in feed, grain, forage, food, and agricultural products |
| Digestion Time | ~100 min per batch (acid digestion: 40 min |
| alkaline digestion | 40 min |
| filtration & washing | ~20 min) |
| Repeatability | ≤0.4% absolute error for samples with crude fiber <10% |
| Cooling Water Requirement | Inlet water temperature <20 °C |
| Compliance Basis | AOAC 962.09, ISO 5498:2022, GB/T 6434–2006 |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SLQ-6 |
| Sample Capacity | 6 positions |
| Sample Mass Range | 0.5–3 g |
| Measurement Range | 0–100% (w/w) |
| Accuracy | Relative deviation ≤4%, Parallel deviation ≤0.4% |
| Total Cycle Time | ≤90 min (acid digestion: 30 min, alkaline digestion: 30 min, filtration & rinsing: ~30 min) |
| Heating System | Six independent semi-spherical ceramic heating elements with individual temperature control per crucible |
| Temperature Range | Ambient to 400 °C |
| Sealing Mechanism | Dual-layer PTFE isolation gasket (top and bottom) |
| Rated Power | 2 kW |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Dimensions (W×D×H) | 570 × 470 × 750 mm |
| Weight | 30 kg |
| Brand | Tianwei Environmental (TW) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TW-ZW108 |
| Price | USD 3,650 (approx.) |
| Sample Capacity | 8 × 0.2 mL tubes |
| Reaction Volume | 5–120 µL |
| Temperature Range | 4–99 °C |
| Max Heating/Cooling Rate | 7 °C/s (heat), 5 °C/s (cool) |
| Temperature Uniformity | ≤ ±0.2 °C |
| Temperature Accuracy | ≤ ±0.1 °C |
| Excitation Source | Maintenance-free LED (400–700 nm) |
| Detection Channel | 1 channel (FAM/SYBR Green I) |
| Display | 7-inch HD capacitive touchscreen |
| Dimensions (L×W×H) | 355 × 200 × 124 mm |
| Net Weight | 2.5 kg |
| Noise Level | <45 dB |
| Thermal Lid | Auto-pressure-adjusting |
| Data Interface | USB port for import/export |
| Compliance | Approved by Ministry of Agriculture and Rural Affairs (MARA) of PRC for ASF virus detection kits |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | FIWE ADVANCE |
| Application Standards | AOAC, AACC, ISO 6865, ISO 13906, ASTM D2974, EN ISO 12151 |
| Automation Level | Fully Automated Acid/Alkali Digestion, Filtration, Washing, and Residue Drying |
| Reagent Handling | Auto-dosing of H₂SO₄, NaOH, α-amylase, protease, ethanol, acetone, and antifoaming agent |
| Filtration System | Pressure-assisted vacuum filtration with programmable air-backflush |
| Control Interface | 7″ capacitive touchscreen (graphical UI, multilingual support) |
| Connectivity | Ethernet and Wi-Fi enabled for VELP Ermes Cloud Platform integration |
| Data Integrity | Audit trail, user access levels, electronic signatures compliant with FDA 21 CFR Part 11 requirements |
| Throughput | Up to 6 samples per run (batch mode), optional 24-position carousel for unattended operation |
| Safety Compliance | CE, UL/CSA certified, integrated fume extraction interface |
| Sample Capacity | 0.5–3.0 g (dry weight), compatible with standard Gooch crucibles or fiber bags (ANKOM-style) |
| Drying Module | Integrated infrared drying unit (60–150 °C, ±1 °C accuracy) |
| Waste Management | Dual-compartment acid/alkali waste collection with level sensors |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | FIWE ADVANCE |
| Sample Capacity | 6 positions |
| Throughput | up to 36 samples/day (Crude Fiber/Wende method), up to 60 samples/day (NDF/ADF/ADL) |
| Sample Mass | 0.5–3 g |
| Measurement Range | 0.1–100% fiber content |
| Repeatability | ±1% (at 5–30% fiber level) |
| Display | 7" color touchscreen |
| Reagent Delivery | Fully automated, pre-heated, precision dosing |
| Digestion Waste Handling | Integrated automatic collection |
| Safety | Closed-system reagent containment, no operator exposure to hot chemicals or fumes |
| Connectivity | LAN, USB (3×), Wi-Fi adapter optional |
| Power Supply | 230 V / 50–60 Hz |
| Power Consumption | 2100 W |
| Dimensions (W×D×H) | 735 × 420 × 666 mm |
| Weight | 57 kg |
| Water Consumption | 1.0 L/min |
| Method Library | 5 pre-installed standard methods (ISO, AOAC, GB) + 30 customizable methods |
| Barcode Scanner Support | Yes |
| Balance Integration | Yes |
| Cloud Platform Compatibility | Via LAN or USB Wi-Fi adapter |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | FIWE |
| Sample Capacity | 6 positions (independent operation per sample) |
| Measurement Principle | Gravimetric difference method after sequential acid/alkali digestion (AOAC 978.10, ISO 5498, ISO 6865, EN ISO 13906) |
| Repeatability (RSD) | ±1% |
| Sample Mass Range | 0.5–3 g |
| Reagent Preheating Units | Dual independent RC2 heaters (RT to 370 °C) |
| Filtration & Backflush | Integrated air pump with three-way valve control |
| Waste Handling | Precision peristaltic pump for residue collection and effluent evacuation |
| Safety System | Self-diagnostic routine with audible/visual alarm timer |
| Construction | Stainless steel housing with chemical-resistant coating |
| Display | LCD interface with programmable time (0–99 min) and temperature settings |
| Power | 1200 W |
| Ambient Operating Temperature Control | Electronic PID regulation |