Shimadzu
Filter
Showing 91–120 of 182 results
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC-manufactured) |
| Model | LCMS-8050RX |
| Price Range | USD 480,000 – 620,000 (FOB Jiangsu) |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Application Scope | General-purpose LC-MS/MS analysis |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC-manufactured) |
| Model | LCMS-8060RX |
| Price Range | USD 63,000 – 77,000 (FOB) |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Application Scope | General-purpose Quantitative and Qualitative Analysis in Regulated and Research Laboratories |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LCMS-8065XE |
| Instrument Type | Triple Quadrupole (TQ) |
| Application Scope | General-Purpose Quantitative Analysis |
| Key Technologies | StreamFocus ESI Ion Source, 4th-Generation UFsweeper™ Collision Cell |
| Compliance | Designed for GLP/GMP environments |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | LCMS-9030 |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Mass Range | 10–40,000 m/z |
| Sensitivity | S/N ≥ 50,000 (1 pg reserpine, ESI+) |
| Resolution | >40,000 (FWHM at m/z 609) |
| Mass Accuracy | <1 ppm (internal calibration, 24-h stability) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | LCMS-9050 |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Mass Range | 10–40,000 m/z |
| Sensitivity | S/N ≥ 50,000 (1 pg reserpine in ESI+ mode) |
| Resolution | >50,000 (FWHM at m/z 609) |
| Mass Accuracy | <1 ppm (internal calibration, 24-h stability) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | LEXT |
| Instrument Type | Liquid-Liquid Extraction System |
| Temperature Range | 0–130 °C |
| Pressure Condition | Ambient (Atmospheric) |
| Extraction Cell Volume | 15 mL |
| Typical Extraction Cycle Time | 10 min |
| Dimensions (W×D×H) | 600 mm × 585 mm × 570 mm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LEXT OLS4500 |
| Pricing | Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PQY-01 |
| Wavelength Range | 250–800 nm |
| Detection System | Photodiode Array (PDA) |
| Optical Configuration | Dual-Wavelength Simultaneous Acquisition |
| Automation Level | Fully Automated Wavelength Scanning & Photonic Flux Calibration |
| Photon Flux Calibration Standard | NIST-Traceable Radiometric Power Meter |
| Measurement Throughput | <10 min per sample for absorbed photon quantification |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | LSV-S |
| Instrument Type | Gas Chromatography (GC) Liquid Injector |
| Purge Method | Heated Purge |
| Viewports | Dual Integrated Borosilicate Glass Viewports with LED Illumination |
| Filtration | Integrated Stainless-Steel Sintered Filter Module (5 µm nominal pore size) |
| Compatibility | Shimadzu Nexis GC-2030, GC-2014/2014C, GC-2010 Pro |
| Brand | Shimadzu |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model Series | MALDI EasyCare |
| Instrument Type | Time-of-Flight (TOF) Mass Spectrometer |
| Resolution | >5000 FWHM in Linear Mode |
| Application Scope | General-Purpose Biomolecular and Small-Molecule Analysis |
| Form Factor | Benchtop |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | MALDImini-1 |
| Instrument Type | Ion Trap–Time-of-Flight (IT-TOF) Hybrid |
| Resolution | >4000 (FWHM at m/z 500) |
| Sensitivity | Low-femtomole (fmol) level for peptides and small molecules |
| Stability | High long-term signal stability under continuous operation |
| Acquisition Rate | 0.6 spectra/s |
| Mass Accuracy | ±200 ppm (external calibration, typical for MALDI-MS in linear mode) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | MCE-202 MultiNA |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MCT Series |
| Load Range | 9.8–1961 mN / 9.8–4903 mN |
| Load Accuracy | ±1% of set or displayed load (whichever is greater) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | MDGC/GCMS |
| Application Scope | General-Purpose Analytical Chemistry |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Method Scouting System |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Flow Rate Range | Not Applicable (System-Level Automation Platform) |
| Maximum Pressure Rating | Not Applicable |
| Autosampler Positions | Not Applicable |
| Injection Volume Range | Not Applicable |
| Column Oven Temperature Range | Not Applicable |
| UV/VIS Wavelength Range | Not Applicable |
| Data Acquisition Frequency | Not Applicable |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Micro Methanizer |
| Instrument Type | Laboratory Gas Chromatograph Accessory |
| Application Scope | Universal for Carbon-Containing Compound Analysis |
| Core Configuration | FID-Integrated Catalytic Converter (Jetanizer & Polyarc Reactor Options) |
| Catalyst Chemistry | Nickel-Free for Jetanizer |
| Linear Dynamic Range | ppm to % (CO/CO₂) |
| Installation Time | <5 min (FID nozzle replacement only) |
| Oxygen Tolerance | Up to 21% O₂ in carrier gas stream |
| Sulfur Resistance | Stable operation with ≤100 ppb H₂S |
| Conversion Efficiency | ≥99% for >200 carbon-containing species including aldehydes, carboxylic acids, halocarbons, and heteroatom-containing compounds |
| Regulatory Alignment | Compatible with USP <621>, ASTM D1945, ISO 8573-5, and GLP-compliant data integrity workflows |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Micro-ESI 9030 |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MIV-X |
| Pricing | Available upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MMT Series |
| Quotation | Upon Request |
| Instrument Category | Specialized Electromagnetic Fatigue Testing Machine |
| Maximum Test Force | ±500 N |
| Frequency Range | 60–100 Hz |
| Host Weight | 80–150 kg |
| Load Capacity Options | ±10 N, ±100 N, ±250 N, ±500 N |
| Piston Stroke | ±2 mm / ±10 mm |
| Load Accuracy | ±0.5% of displayed value |
| Force Resolution | 0.01 N |
| Displacement Resolution | ±0.125 µm |
| Control Architecture | Dual-degree-of-freedom PID control with 24-bit DAC/ADC resolution |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | Shimadzu Mobile Laboratory |
| Pricing | Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MOC-120H |
| Pricing | Upon Request |
| Measurement Principle | Gravimetric Loss-on-Drying (Infrared Heating) |
| Sample Capacity | 0.5–120 g |
| Moisture Resolution | 0.1% or 0.01% (selectable) |
| Mass Resolution | 0.001 g |
| Moisture Range | 0–100% (w/w, solid moisture) |
| Repeatability (SD) | ≤0.05% (≥5 g sample), ≤0.02% (≥10 g sample) |
| Drying Modes | Auto-Stop, Timer-Stop (1–240 min or continuous up to 12 h), Rapid Dry, Gradual Dry, 5-Stage Programmable Ramp, Comparative Prediction Mode |
| Temperature Range | 30–180 °C (1 °C increments) |
| Heating Source | Medium-Wave Infrared Lamp (625 W max) |
| Power Supply | AC 100–120 V / 220–240 V, 50/60 Hz |
| Max Power Consumption | 640 W |
| Dimensions (W×D×H) | 220 × 415 × 190 mm |
| Weight | 4.5 kg |
| Sample Pan | Stainless Steel (Ø130 mm × 13 mm depth) |
| Display | LCD |
| Interface | RS-232C |
| Data Storage | 100 measurement records |
| Method Storage | 10 user-defined protocols |
| Operating Environment | 5–40 °C, ≤85% RH |
| Key Hardware | Monolithic Load Cell Sensor |
| Auto-Zero Compensation | Yes (real-time drift correction during heating) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MOC-120H |
| Price Range | USD 1,400 – 4,200 |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic |
| Model | MXF-N3 Plus |
| Price Range | USD 210,000 – 280,000 |
| Instrument Type | Simultaneous Multi-Channel |
| X-ray Tube Power | 3 kW |
| Elemental Range | Na (11) to U (92) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Nexera FV |
| Instrument Type | Ultra-High-Performance Liquid Chromatography (UHPLC)-Coupled Dissolution Testing System |
| Flow Rate Range | 0.0001–10 mL/min |
| Maximum Operating Pressure | 130 MPa (19,000 psi) |
| Autosampler Configuration | Integrated 8-position (standard) or 12-position (optional) flow-through vial rack |
| Temperature Control | Ambient to 45 °C (column oven & dissolution bath interface compatible) |
| Wavelength Range | Not applicable (system interfaces with external UV-Vis or PDA detector |
| Data Acquisition Frequency | Up to 100 Hz (synchronized with dissolution sampling events) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Nexera GPC System |
| Instrument Type | Conventional High-Performance Liquid Chromatography (HPLC) System for Gel Permeation Chromatography |
| Price Range | USD 70,000 – 140,000 (approx. based on ¥500,000–¥1,000,000 at current exchange rate) |
| Flow Rate Range | Not applicable (GPC-specific isocratic or low-gradient elution |
| Maximum Pressure Rating | Not specified in source (typical for GPC: ≤40 MPa) |
| Sample Injection Positions | Configurable via SIL-40 series autosampler (up to 216 vials standard) |
| Injection Volume Range | 0.1–100 µL (autosampler-dependent) |
| Column Oven Temperature Range | 4–85 °C (standard CTO-40 series column oven) |
| UV/VIS Wavelength Range | 190–800 nm (with SPD-M40 photodiode array detector or SPD-40V UV-Vis detector) |
| Data Acquisition Rate | Up to 100 Hz (detector-dependent) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer | Shimadzu Corporation |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum System Pressure | 130 MPa |
| Autosampler Capacity | Up to 16,800 positions (via microplate stacking) |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | –10°C to 85°C |
| UV-Vis Detector Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 100 Hz |
| Detector Options | SPD-40/SPD-40V UV-Vis, SPD-M40 Diode Array Detector (DAD) |
| Compliance | ASTM D7097, ISO 17025, USP <621>, FDA 21 CFR Part 11 (with LabSolutions™ CS audit trail enabled) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model Series | LC-40 |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Flow Rate Range | 0.0001–10 mL/min |
| Maximum System Pressure | 130 MPa |
| Autosampler Capacity | 162 positions (1.5 mL vials) |
| Injection Volume Range | 0.1–50 µL |
| Column Oven Temperature Range | (Ambient −10 °C) to 100 °C |
| UV-Vis Detection Wavelength Range | 190–1000 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Model | Nexera LC-40 |
| Application Scope | General-purpose analytical laboratory use |
| Flow Rate Range | Up to 5.0 mL/min |
| Maximum Operating Pressure | 130 MPa (1300 bar) |
| Flow Accuracy | ≤0.1% RSD |
| Injection Volume Range | 0.1–100 µL |
| Sample Tray Capacity | Up to 216 positions (with optional 2nd tray) |
| Column Oven Temperature Range | 4–85 °C |
| UV-Vis Detection Wavelength Range | 190–800 nm |
| Data Acquisition Rate | Up to 125 Hz |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LC/SFC Switching System |
| Instrument Type | Analytical |
| Detector Compatibility | UV, Photodiode Array (PDA), Mass Spectrometry (MS) |
| Maximum Operating Pressure | 66 MPa |
| Flow Rate Range | 0.4–5.0000 mL/min |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Nexera UC |
| Instrument Type | Analytical |
| Detector Types | UV, Photodiode Array (PDA), Mass Spectrometer (MS) |
| Maximum Operating Pressure | 66 MPa |
| Flow Rate Range | 0.0001–5.0000 mL/min |
