Shimadzu
Filter
Showing 121–150 of 182 results
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Nexera UC Prep |
| Instrument Type | Semi-Preparative |
| Flow Rate Range | Up to 150.0 mL/min |
| Detector Options | UV, Photodiode Array (PDA), Mass Spectrometer (MS) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Nexera UC |
| Instrument Type | Analytical |
| Detector Options | UV, Photodiode Array (PDA), Mass Spectrometer (MS) |
| Maximum Operating Pressure | 66 MPa |
| Flow Rate Range | 0.0001–5.0000 mL/min |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Nexera XS inert |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Bioanalytical LC |
| Flow Rate Range | 0.0001–10.0000 mL/min |
| Maximum Operating Pressure | 105 MPa |
| Flow Precision | ≤0.06% RSD or ≤0.02 min SD (whichever is greater) |
| Injection Volume Range | 0.1–50 µL |
| Autosampler Capacity | 252 positions (1 mL vials) / 162 positions (1.5–2 mL vials) / 84 positions (4 mL vials) |
| Column Oven Temperature Range | Ambient −10 °C to 100 °C (85 °C for high-stability operation) |
| UV-Vis Wavelength Range | SPD-40 detector: 190–700 nm |
| SPD-40V detector | 190–1000 nm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Nexera-e |
| Instrument Type | Comprehensive 2D-LC System |
| Flow Rate Range | Not Applicable (Modular Dual-Flow Architecture) |
| Maximum System Pressure | 130 MPa (2nd Dimension) |
| Sample Injection Positions | Dual Sample Loops with Alternating Switching |
| Injection Volume Range | Configurable via Loop Selection (e.g., 1–100 µL) |
| Column Oven Temperature Range | Ambient to 85 °C |
| Wavelength Range (DAD) | 190–800 nm |
| Data Acquisition Rate | Up to 125 Hz (SPD-M30A), 20,000 u/sec (LCMS-IT-TOF) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | CAGC-2030 |
| Price Range | USD 42,000 – 70,000 |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | Nexis GC-2030 Enhanced Edition |
| Price Range | USD 42,000 – 70,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient +2 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cooling Rate | 450 °C → 50 °C in ≤3.4 min (at 22 °C ambient) |
| Carrier Gas Flow Control Range | 0–1250 mL/min (7 programmable segments) |
| Carrier Gas Pressure Control Range | 0–1035 kPa (7 programmable segments) |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Total Injector Flow Setting Range | 0–1300 mL/min (He or H₂), 0–600 mL/min (N₂) |
| Key | Brand: Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analysis |
| Oven Temperature Range | Ambient +2 °C to 450 °C |
| Oven Ramp Rate | 0.01–250 °C/min |
| Oven Cool-Down Time | ~3.4 min (450 °C → 50 °C) |
| Carrier Gas Flow Control | 0–1300 mL/min He |
| Carrier Gas Pressure Control | 0–1035 kPa (7 programmable segments) |
| Injector Max Temp | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Injector Total Flow Setting Range | 0–1300 mL/min He |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Nexis SCD-2030 |
| Instrument Category | Sulfur-Specific Chromatographic Detector |
| Flow Path Design | Horizontal Combustion Chamber with Ultra-Short Reaction Pathway |
| Maintenance Interval | Ceramic Reactor Tube Replacement in ≤5 Minutes |
| Automation Level | Fully Automated Startup, Vacuum Initiation, Gas Flow Optimization, Baseline Stabilization, Analysis Execution, and Shutdown Sequence |
| Compliance Ready | Designed for GLP/GMP environments with audit-trail-capable software integration |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Nexlock |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | NOA-7000 / CGT-7000 / SOA-7000 |
| Pricing | Available Upon Request |
| Measurement Accuracy | ±0.5% of Full Scale |
| Weight | ~14.5–15 kg |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Online Fixed-Mount Analyzer |
| Model | NSA-3080A |
| Measurement Principle | Non-Dispersive Infrared (NDIR) + Electrochemical (EC) + Paramagnetic (O₂) |
| Gas Components | SO₂, NOₓ, CO, CO₂, O₂ (up to 5 simultaneously) |
| Detection Ranges | NOₓ (100–2500 ppm), SO₂ (100–5000 ppm), CO (100 ppm–1 vol%), CO₂ (5–20 vol%), O₂ (0–25 vol%) |
| Calibration | Automated hourly or weekly zero/span correction |
| Operating Ambient Temperature | −5 to 40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz, ~700 VA |
| Data Storage | Removable SD card interface |
| Compliance | Designed for continuous emissions monitoring (CEMS) per Chinese HJ 75/76 standards |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CEMS |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Core Analyzers | NSA-3080A Online Gas Analyzer, RBV-DUST/II In-Situ Dust Monitor, VPT511BF-A Volumetric Flow Meter |
| Data Acquisition | Integrated DAQ & Reporting Platform |
| Regulatory Alignment | Designed for compliance with HJ 75–2017, HJ 76–2017, EPA Method 1–4, 6C, 7E, 10, and ISO 12141, ISO 15712 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Off-Flavor Analyzer |
| Instrument Type | Triple Quadrupole Mass Spectrometer (GC-MS/MS) |
| Mass Range | 2–1090 u |
| Resolution | Unit Mass Resolution |
| Sensitivity | >20,000:1 (S/N, using chlorobenzene, m/z 112) |
| Scan Speed | 20,000 u/s |
| Chromatographic Configuration | Multi-column switching platform (three polarities: DB-5ms, DB-WAX, InertCap Pure-WAX) |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | PDA-5000 |
| Instrument Type | Floor-standing |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 600 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 120–800 nm |
| Maximum Number of Channels | 24 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Floor-Standing |
| Excitation Source | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 600 mm |
| Groove Density | 2400 lines/mm |
| Wavelength Range | 120–800 nm |
| Maximum Channel Count | 64 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | PDA-8000 |
| Configuration | Floor-standing |
| Excitation Source | Spark Discharge |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 1000 mm |
| Wavelength Range | 120–800 nm |
| Maximum Channel Count | 64 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Peakintelligence |
| Chromatography Type | Conventional Gas Chromatography–Mass Spectrometry (GC-MS) |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Petrochemical Accessories Kit |
| Instrument Type | Laboratory Gas Chromatograph Accessories |
| Application Field | Petroleum & Petrochemical Industry |
| Key Components | G-VAPORIZER Flash Vaporizer |
| Compliance | Designed for ASTM D1319, D5769, D6730, ISO 6974, and USP <467> residual solvent methods |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PPSQ-51A / PPSQ-53A |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | Shimadzu PR-1000 |
| Temperature Range | Ambient |
| Reaction Tubing Material | FEP (Fluorinated Ethylene Propylene) |
| UV Source Lifetime | 9,000 hours |
| Derivatization Flow Path | Passive (No Pump-Driven Reagent Delivery) |
| UV Leakage Protection | Integrated Shielding with UV-Blocking View Window |
| Delay Volume | Optimized for Minimal Extra-Column Dispersion |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Detection Modes | Suppressed and Non-Suppressed Conductivity Detection |
| Application Scope | Trace Anion and Cation Analysis in Environmental, Pharmaceutical, Food, and Industrial Samples |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | Prominence Plus LC-20A |
| Instrument Category | Fast Liquid Chromatography System |
| Application Scope | General-purpose HPLC analysis |
| Maximum Operating Pressure | 44 MPa (LC-20AT) / 66 MPa (LC-20ADXR) |
| Flow Rate Precision | ≤0.06% RSD or ≤0.02 min SD |
| Injection Volume Range | 0.1–50 µL (standard), 0.1–2000 µL (optional) |
| Sample Tray Capacity | 175 positions (1 mL vials) |
| Column Oven Temperature Range | Ambient +10 °C to 85 °C (standard) |
| UV-Vis Detection Wavelength Range | 190–700 nm |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Prominence Plus LC-30A |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Analytical Platform |
| Flow Rate Range | 0.0001–10.0000 mL/min |
| Maximum Operating Pressure | 130 MPa |
| Flow Rate Precision | <0.06% RSD or 0.02 min SD (whichever is greater) |
| Injection Volume Range | 0.1–50 µL |
| Sample Capacity | 175 positions (1 mL vials) |
| Column Oven Temperature Range | Ambient ±10 °C to 85 °C |
| UV-Vis Detection Wavelength Range | 190–700 nm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Prominence UFLC |
| Instrument Type | Ultra-Fast Liquid Chromatograph |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Prominence UFPLC |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Py-Screener |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Chromatography Type | Pyrolysis-Gas Chromatography Coupled with Mass Spectrometry (Py-GC/MS) |
| Mass Range | 1.5–1090 u |
| Resolution | Unit Mass Resolution |
| Sensitivity | >1500:1 (Signal-to-Noise Ratio, S/N) |
| Scan Speed | 20,000 u/s |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | RF-6000 |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Bandwidth (Slit Width) | 1.0–20.0 nm |
| Optical Resolution | 1.0 nm |
| Sensitivity (S/N Ratio) | ≥1000:1 (RMS) |
| Wavelength Range | Excitation 200–900 nm, Emission 200–900 nm |
| Scan Speed | Up to 60,000 nm/min |
| Light Source | Long-life Xenon Lamp (2000 h typical lifetime) |
| Detector | Broadband Photomultiplier Tube (PMT), extended to 900 nm |
| Dispersion Element | Dual grating + interference filter system |
| Quantum Yield Measurement | Supported (absolute and relative) |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RM-3000 |
| Instrument Type | Handheld Portable Raman Spectrometer |
| Spectral Range | 200–3000 cm⁻¹ |
| Spectral Resolution | 4 cm⁻¹ |
| Spatial Resolution | 0.22 mm |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Repeatability | <1 cm⁻¹ |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SEM-SERVO |
| Instrument Type | Electro-Hydraulic Servo Fatigue Testing System |
| Maximum Test Load | 10 kN |
| Frequency Range | 0.001–5 Hz (sine wave) |
| Operating Temperature Range | Ambient to +800 °C (optional high-temperature chamber) |
| SEM Resolution | 3 nm at 30 kV |
| SEM Magnification Range | ×5 to ×300,000 (digital display) |
| In-situ Observation Area | 6 mm × 16 mm (X-Y motorized stage) |
| Load-Triggered Static Imaging Capability | Optional (synchronized deformation freeze) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SFE-40P |
| Pricing | Available Upon Request |