| Brand | Southland Sensing |
|---|---|
| Origin | Beijing, China |
| Model | FSR-600FB |
| Linear Error | ≤ ±1% F.S. |
| Repeatability | ≤ ±1% F.S. |
| Span Drift | ≤ ±1% F.S. / 7 days |
| Response Time (T90) | ≤ 1 s |
| Explosion Protection Rating | Ex d II C T6 |
| Sample Flow Rate | 0.3–0.5 L/min |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Temperature | −5 °C to +45 °C |
| Relative Humidity | ≤ 90% RH |
| Inlet Pressure Range | 0.05–0.1 MPa |
| Analog Output | 4–20 mA |
| Electrical Interface | 1/2 NPT |
| Sample Port | G1/2 |
| Zero Drift | ±1% F.S. / 7 days |
| Resolution | 0.01% vol |
| Warm-up Time | 10 min |
| MTBF | > 3 years |
| Brand | Southland Sensing |
|---|---|
| Model | MOMD-480 |
| Origin | USA (California) |
| Measurement Principle | Electrochemical Fuel Cell |
| Range Options | 0–1%, 0–5%, 0–10%, 0–25%, 0–100% O₂ (selectable) |
| Accuracy | < ±1% FS |
| Response Time | ≤10 s to T90 |
| Operating Temperature | 0–50 °C |
| Gas Pressure Range | 0–50 PSI (inlet) |
| Power | Rechargeable Li-ion battery + 100–240 VAC adapter |
| Dimensions | 8.80 × 7.50 × 3.90 in (223.5 × 190.5 × 99.1 mm) |
| Weight | 4.8 lb (2.18 kg) |
| Enclosure Material | Polypropylene |
| Sensor Lifetime | 60 months |
| Analog Output | 0–1 VDC |
| Data Logging | USB flash drive (up to 8 GB, supports >50 years of timestamped data at 1-min intervals) |
| Display | Backlit high-contrast LCD |
| Warranty | 12 months |
| Compliance | Designed for GLP-compliant field use |
| Brand | Southland Sensing |
|---|---|
| Model | OMD-525X |
| Origin | USA |
| Housing | ABS, IP65-rated |
| Sensor Types | TO2-1x (0–10 ppm), TO2-2x (0–10 ppm), PO2-160/24/1120 (0–100% O₂) |
| Measurement Range | 0.01 ppm–100% O₂ (selectable via hardware switch) |
| Accuracy | ±1% of reading |
| Response Time (t₉₀) | ≤15 s |
| Operating Temp. | 5–45°C (TO2), −20–45°C (PO2) |
| Pressure Range | 0–3 MPa inlet, ambient exhaust |
| Flow Rate | 0.25–2.5 L/min (recommended: 1 L/min) |
| Output | 4–20 mA analog + dual relay alarms |
| Power | 9–28 VDC |
| Display | Backlit LCD, 0.01 ppm resolution |
| Data Storage | 8 GB USB logging |
| Compensation | Automatic temperature & pressure |
| Calibration | Certified span gas (~80% of selected range) |
| Sensor Lifetime | 24 months at 25°C |
| Warranty | 12 months (instrument & sensor) |
| Enclosure Rating | IP65 |
| Sample Interface | 1/4" compression fittings |
| Linearity | >0.995 R² across full scale |
| Sensitivity | <0.5% FS |
| Sample Compatibility | N₂, Ar, He, H₂, CO₂, C₂H₂, C₂H₄, C₄H₆, hydrocarbons (CnHm), and inert or reducing matrices |
| Brand | Southland Sensing |
|---|---|
| Origin | Germany |
| Model | TMA-210-P-P |
| Product Type | Portable Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | −20 °C to +150 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm, 0–100 ppm, 0–1000 ppm, 0–2500 ppm (auto/manual range switching) |
| Display | Touchscreen with optional Chinese language interface |
| Output Signals | 4–20 mA (configurable), High/Low alarm relay outputs |
| Power Supply | Rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Power Consumption | 8 W |
| Enclosure Rating | IP20 |
| Dimensions | 363 mm (W) × 115 mm (H) × 377 mm (D) |
| Weight | ~6 kg |
| Intrinsic Safety | Integrated Zener barrier compliant with IEC/EN 60079-11 for hazardous area use |