Sundhy
Filter
Showing all 9 results
| Brand | Sundhy |
|---|---|
| Model | SDAF1000 |
| Origin | Hunan, China |
| Sample Capacity | 1–5 specimens per run |
| Atmosphere Control | Oxidizing and weakly reducing (carbon-sealing method) |
| Temperature Range | Ambient to 1600 °C |
| Temperature Resolution | 1 °C |
| Temperature Stability | ±1 °C |
| Max. Power Consumption | 4.2 kW |
| Supply Voltage | AC 220 V ±10 %, 50 Hz ±1 Hz |
| Compliance | GB/T 219–2008, GB/T 30726–2014 |
| Brand | Sundhy |
|---|---|
| Origin | Hunan, China |
| Model | SDAF1200(a/b) |
| Sample Capacity | 1–10 specimens |
| Temperature Range | Ambient to 1600 °C |
| Temperature Resolution | 1 °C |
| Temperature Control Accuracy | ±1 °C |
| Atmosphere Control | Oxidizing / Weakly Reducing (SDAF1200a: Carbon-Sealing Method only |
| SDAF1200b | Carbon-Sealing + Gas-Flow Method with CO/CO₂ or H₂/CO₂ mixtures) |
| Max. Power | 4.2 kW |
| Supply Voltage | AC 220 V ±10%, 50 Hz ±1 Hz |
| Dimensions (W×D×H) | 850 mm × 550 mm × 843 mm |
| Net Weight | ~108 kg |
| Compliance | GB/T 219–2008, GB/T 30726–2014 |
| Brand | Sundhy |
|---|---|
| Model | SDCHN636 |
| Origin | Hunan, China |
| Measurement Principle | Infrared Absorption (for C/H) & Thermal Conductivity Detection (for N) |
| Sample Capacity | 36 positions (single tray) / 72 positions (dual tray) |
| Carbon Range | 0.005–100 wt% |
| Hydrogen Range | 0.01–50 wt% |
| Nitrogen Range | 0.01–50 wt% |
| Sample Mass | 75–105 mg (recommended: 100 mg) |
| Repeatability | Compliant with GB/T 30733-2014 and ASTM D5373-08 |
| Analysis Time per Sample | 6–8 min |
| Power Consumption | ≤4.5 kW |
| Supply Voltage | AC 220 V ±10%, 50 Hz ±1 Hz |
| Gas Requirements | O₂ (≥99.99%, ≥1 MPa) |
| Dimensions (L×W×H) | 710 × 660 × 1045 mm |
| Weight | ~140 kg |
| Brand | Sundhy |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | SDIAS |
| Pricing | Available Upon Request |
| Brand | Sundhy |
|---|---|
| Model | SDIS401 |
| Measurement Principle | Ultraviolet-Fluorescence (UVF) with Infrared Detection |
| Standard Compliance | GB/T 25214–2010, ISO 19579:2006, ASTM D4239–2018 |
| Test Range | 0.01–50 wt% (extendable) |
| Analysis Time | ~120 s per sample |
| Combustion Temperature | 1250–1350 °C (recommended: 1300 °C) |
| Sample Mass | 200 mg (nominal) |
| Furnace Power | 4 kW |
| Dimensions (L×W×H) | 760 × 434 × 752 mm |
| Weight | ~80 kg |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Sample Capacity | 1 position (manual loading) |
| Detector Type | Low-drift infrared absorption cell |
| Gas Conditioning | Integrated desiccant and particulate filtration |
| Gas Path Design | Patented low-dead-volume, temperature-stabilized flow path |
| Brand | Sundhy |
|---|---|
| Origin | Hunan, China |
| Model | SDLOI2000 |
| Sample Capacity | 20 positions |
| Sample Mass Range | 0.1–10 g (user-definable) |
| Temperature Range | Ambient to 1050 °C |
| Temperature Control Accuracy | ±2 °C |
| Balance Resolution | 0.0001 g |
| Maximum Power Consumption | 4 kW |
| Dimensions (L×W×H) | 550 × 590 × 530 mm |
| Net Weight | ~70 kg |
| Power Supply | AC 220 V ±10 %, 50 Hz ±1 Hz |
| Brand | Sundhy |
|---|---|
| Model | SDS720 |
| Principle | Coulometric Titration |
| Origin | Hunan, China |
| Measuring Range | 0.01–40% S |
| Sulfur Resolution | 0.001% |
| Temperature Control Accuracy | ±1°C |
| Sample Mass | ~50 mg (adjustable) |
| Combustion Furnace Temperature | (1150±5)°C for coal & coke |
| Max. Sample Capacity | 21 positions |
| Avg. Analysis Time | ~200 s per sample |
| Max. Power Consumption | 4 kW |
| Supply Voltage | AC 220 V ±10%, 50 Hz ±1 Hz |
| Dimensions (W×D×H) | 610 × 890 × 410 mm |
| Net Weight | ~81 kg |
| Compliance | GB/T 214–2007, JJG 1006–2005 |
| Brand | Sundhy |
|---|---|
| Origin | Hunan, China |
| Model | SDTGA1200 |
| Sample Mass Range | 0.5–1.1 g (user-definable) |
| Furnace Temperature Range | Ambient to 1000 °C |
| Number of Samples per Run | 18 |
| Temperature Control Accuracy | ±2 °C |
| Full Industrial Analysis Cycle Time | ≤8 h for 54 samples (3 batches) |
| Max Power Consumption | 5.5 kW |
| Supply Voltage | AC 220 V ±10 %, 50 Hz ±1 Hz |
| Balance Resolution | 0.1 mg |
| Compliance | GB/T 212–2008, GB/T 30732–2014, ASTM D5142–2009 |
| Brand | Sundhy |
|---|---|
| Origin | Hunan, China |
| Model | SDTGA6000 / SDTGA6001 / SDTGA6002 |
| Sample Mass Range | 0.5–10 g (user-definable) |
| Balance Resolution | 0.0001 g |
| Water/Ash Capacity | SDTGA6000/6002: 20 samples |
| SDTGA6001 | 16 samples |
| Volatile Matter Capacity | 26 samples |
| Furnace Temperature Range | Ambient to 1000 °C |
| Temperature Control Accuracy | ±2 °C |
| Power Supply | AC 220 V ±10 %, 50 Hz ±1 Hz |
| Max. Power Consumption | Water/Ash Module: 4 kW |
| Volatile Matter Module | 2.5 kW |
| Typical Test Duration | Water/Ash (fast method): ~100 min |
| Volatile Matter | ~130 min |