Thermo Fisher Scientific
Filter
Showing 1–30 of 64 results
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | COUNTESS® II FL |
| Price Range | USD 7,000 – 14,000 (FOB US) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | CryoMed Programmable Cooling System |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ICS-4000 ED |
| Application Environment | Laboratory-Based |
| Detection Modes | DC Amperometry, Pulsed Amperometric Detection (PAD), Integrated Pulsed Amperometric Detection (IPAD) |
| Electrode Compatibility | pH-Ag/AgCl, Ag/AgCl, Palladium-Hydrogen (PdH) Reference Electrodes |
| Control Interface | Chromeleon Chromatography Data System (CDS) via Ethernet |
| Thermal Stability | Engineered for minimal thermal drift in detector electronics and flow cell housing |
| Electrical Architecture | Fully integrated flow cell and detector electronics with optimized shielding, galvanic isolation, and low-noise signal conditioning |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Instrument |
| Model | ICS-4000 QD |
| Pump Pressure Rating | 6000 psi |
| Flow Rate Range | 0.001–0.100 mL/min |
| Eluent Flow Rate | 0.001–0.100 mL/min |
| Maximum Operating Pressure | 6000 psi |
| Operating Temperature Range | 10–40 °C |
| Temperature Reproducibility | ±0.2 °C |
| Eluent Concentration Range | 0.1–200 mM |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | HAAKE MiniCTW |
| Motor Power | 400 W |
| Speed Range | 1–360 rpm |
| Max Temperature | 300 °C |
| Max Pressure | 200 bar |
| Screw Geometry | Conical Twin-Screw |
| Screw Rotation | Co-rotating or Counter-rotating Configurable |
| Screw Material | Stainless Steel 1.4122 (X46Cr13) |
| Barrel Material | High-Performance Plastic Mold Steel (ASSAB M340) |
| Heating Time | < 10 min (80–240 °C) |
| Feeding Method | Manual Feeder (Optional: HAAKE Forced Feeder) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | MiniCTW |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Laboratory-Scale Co-Rotating Twin-Screw Extruder |
| Screw Diameter | 11 mm |
| L/D Ratio | 40:1 |
| Drive Power | 1.25 kW |
| Speed Range | 10–1000 rpm (infinitely variable) |
| Max Operating Pressure | 100 bar (with integrated safety monitoring) |
| Temperature Range | Ambient to 350 °C (optional up to 450 °C) |
| Barrel Zones | 8 (1 cooling feed zone + 7 independently heated zones) |
| Footprint | 82 × 48 × 34 cm (L × W × H) |
| Throughput | Up to 2.5 kg/h |
| Minimum Sample Requirement | ~20 g |
| Screw Design | Modular, segmentable for customizable configuration |
| Barrel Configuration | Horizontally split, top barrel section removable |
| Control Interface | Integrated color touchscreen |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Benchtop Controlled-Stress/Controlled-Rate Rotational Rheometer |
| Model | RS 1 |
| Drive System | Air-bearing motor |
| Minimum Rotational Speed | 1.0 × 10⁻³ rpm |
| Maximum Rotational Speed | 1200 rpm |
| Angular Frequency Range (Oscillatory Mode) | 1.0 × 10⁻⁴ – 100 rad/s |
| Maximum Torque | 100 mN·m |
| Torque Resolution | 5 nN·m |
| Angular Displacement Resolution | 0.012 µrad |
| Motor Inertia | 11 µN·m·s² |
| Normal Force Range | Not specified |
| Normal Force Resolution | Not specified |
| Temperature Control Options | Peltier (–40 to +180 °C), Electric Heating (+20 to +200 °C), Liquid Circulator (–40 to +180 °C) |
| Optional Accessories | Star Geometry, SHRP Asphalt Testing System, Anti-Slip System |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Model | VT1 Plus / VT2 Plus |
| Instrument Type | Battery-Powered Rotational Viscometer |
| Viscosity Range | VT1 Plus: 1.5–330 mPa·s |
| VT2 Plus | 0.3–4000 dPa·s |
| Temperature Capability | Up to 150 °C |
| Rotational Speed | 62.5 rpm |
| Repeatability | ±1% of Full Scale Deflection (FSD) |
| Standard Accuracy | ±5% FSD |
| Display | Digital LCD |
| Power | 4 × AA batteries (included), with optional charger |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | NanoDrop Eight |
| Optical Design | Dual-beam |
| Detector | CCD Array |
| Wavelength Range | 190–850 nm |
| Wavelength Automation | Fully Automatic |
| Spectral Bandwidth | ≤1.8 nm |
| Wavelength Accuracy | ±1 nm |
| Stray Light | ≤0.01% T |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Radiation and Contraband Detection System |
| Model | RadEye CD |
| Detector Type | RadEye SX with NaI(Tl) Scintillation Detector |
| Measurement Capability | Simultaneous detection of concealed contraband (e.g., tobacco, explosives, alcohol) and radioactive materials |
| Measurement Range | 5–10 cps (background), 50–100 cps (contraband presence) |
| Sensitivity | ≥5 cps minimum detectable signal above background |
| Analysis Channels | Dual-channel spectral analysis |
| Typical Background Count Rate | 5 cps |
| Effective Measurement Time | 1 second per acquisition |
| Regulatory Compliance | Designed for customs, border security, and port-of-entry applications in accordance with IAEA TS-G-1.2 and ANSI N42.34 standards |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | SPECTRONIC 200 |
| Instrument Architecture | Single-beam |
| Detector Type | Photodiode Array |
| Wavelength Range | 340 nm – 1000 nm |
| Wavelength Scanning | Motorized Auto-wavelength Selection |
| Spectral Bandwidth | < 4 nm |
| Wavelength Accuracy | ±1.0 nm (typical, per ASTM E275) |
| Stray Light | < 0.1% T at 340 nm (as measured per ISO 9050) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Model | PrintMate AS |
| Capacity Options | 150 (2-slot), 450 (6-slot), 900 (12-slot) |
| Cassette Load per Slot | 75 |
| Input Mechanism | Rotary Magazine Feeding |
| Compatible Cassette Type | Standard 45°-angled plastic tissue cassettes |
| Printing Technology | Thermal Foil Transfer with High-Durability Ribbons |
| Barcode/QR Support | Code 128, Code 39, Data Matrix, QR Code |
| Character Set | Unicode-compliant (Latin, Cyrillic, Greek, CJK Unified Ideographs), Windows TrueType Fonts |
| Interface | HL7, ASTM LIS/HIS Integration |
| Compliance | ISO 15189, CLIA, CAP, FDA 21 CFR Part 11 (audit trail & electronic signature ready) |
| Optional Module | Smart Sorting Drawer System (100-cassette simultaneous collection) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | ASE350 |
| Extraction Type | Solid-phase accelerated solvent extraction (ASE) |
| Pressure Range | 1500 psi |
| Temperature Range | Up to 200 °C |
| Flow Rate | 70 mL/min |
| Extraction Cell Volumes | 1, 5, 10, 22, 34, 66, and 100 mL |
| Solvent Options | Up to 3 solvents programmable per method |
| Solvent Consumption | <50 mL per 20 g sample (typical) |
| Automation Capacity | Up to 24 samples unattended |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Continuum XL |
| Pricing | Available upon request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Corona Veo |
| Instrument Type | Universal Chromatographic Detector |
| Flow Rate Range | 0.01–2.0 mL/min |
| Detection Principle | Charged Aerosol Detection (CAD) |
| Sensitivity | Sub-nanogram |
| Linear Dynamic Range | >4 orders of magnitude |
| Compatibility | HPLC, UHPLC, microLC, capillary LC |
| Software Drivers | Chromeleon CDS, ChemStation, EZChrom, OpenLab, Empower 2/3 |
| Regulatory Compliance | Supports 21 CFR Part 11 audit trails, GLP/GMP-compliant data integrity workflows |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Dionex ICS-6000 |
| Operating Pressure | Up to 5000 psi (34.5 MPa) |
| Column Compatibility | Capillary and Analytical Format (e.g., 4 µm particle size columns) |
| Detector Options | DC Conductivity Detector (dual-zone temperature control), ED Electrochemical Detector, VWD/PDA UV-Vis Detector |
| Software | Dionex Chromeleon Chromatography Data System (CDS) |
| Compliance | Designed for GLP/GMP environments |
| Typical Service Life | ~10 years (refurbished & validated) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Dispersive Raman Spectrometer (not FT-Raman) |
| Spectral Range | 50–6000 cm⁻¹ |
| Spectral Resolution | <2 cm⁻¹ |
| Spatial Resolution | Micron-level |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ±0.2 cm⁻¹ |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | EASY-nLC 1000 |
| Instrument Type | Nanoflow Liquid Chromatography System |
| Column ID | 50 µm |
| Packing Particle Size | 1.9 µm |
| Maximum Operating Pressure | Up to 1000 bar |
| Gradient Precision | <0.2% RSD |
| Flow Rate Range | 50–1000 nL/min |
| Injection Volume Precision | <1% RSD |
| System Dead Volume | <100 nL |
| Software Platform | Thermo Scientific Xcalibur |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Temp JKT |
| Price | Upon Request |
| Thermocouple Types | J, K, T |
| Temperature Range | –250 °C to 1372 °C (K-type), –250 °C to 400 °C (T-type), –2.00 °C to 1000 °C (J-type) |
| Resolution | 0.1 °C (–99.9 °C to 299.9 °C) |
| Accuracy | ±0.2% of reading + 0.5 °C (t > –99.9 °C) |
| Offset Adjustment | ±10 °C |
| Display | LCD |
| Power | 4 × 1.5 V AAA alkaline batteries |
| Battery Life | >200 hours |
| Operating Temperature | –10 °C to 50 °C |
| Dimensions (unit) | 140 × 70 × 35 mm |
| Weight (unit) | 200 g |
| Input Connector | 2-pin ANSI mini thermocouple interface |
| Data Hold | Yes |
| Auto Power-Off | Yes |
| Low-Battery Indicator | Yes |
| Factory-Calibrated | Yes |
| Self-Diagnostic Functions | Yes |
| Key-Based Calibration | Yes |
| Power-Save Mode | Yes |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Origin Category | Imported |
| Model | ELEMENT 2 |
| Instrument Type | Magnetic Sector ICP-MS (not quadrupole) |
| Sensitivity | >10⁹ cps/ppm for In |
| Resolution | 300, 4,000, and 10,000 (10% valley definition) |
| Dynamic Range | >10⁹ (linear) |
| Background Equivalent Concentration (BEC) | <0.2 cps |
| Detection Mode | Simultaneous multi-element detection for transient signals |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | ES01 |
| Service Fee | USD 7,000–14,000 (quoted per project) |
| Industry Experience | >10 years |
| Emergency Response Time | ≤12 hours |
| Scope | Cross-brand, multi-sector full-laboratory relocation |
| Service Coverage | Nationwide (China) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ESCALAB Xi+ |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | F1600 / F1700 / F1800 |
| Temperature Range | 150–1360 °C |
| Chamber Volume | 5.7–41.4 L |
| Construction | Heavy-duty refractory brick lining + reinforced steel cabinet |
| Heating Element Configuration | Four-wall embedded in refractory cement |
| Standard Floor Protection | Ceramic hearth plate |
| Power Supply | Requires external hardwiring |
| Controller | Sold separately |
| Safety Design | Top-hinged door with heat-shielded orientation (hot surface directed away from operator) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | F30400 |
| Temperature Range | 100–1093 °C (up to 1200 °C short-term) |
| Chamber Volume | 45 L |
| Heating Element Layout | Top, Bottom, Left & Right Walls |
| Safety | 35 A Circuit Breaker + Interlocked Door Switch |
| Control Options | B1 (Single-Setpoint), C1 (8-Step Single Program), D1 (16-Step × 4 Programs, RS232) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | F31700 |
| Temperature Range | 150–1093 °C |
| Chamber Volume | 254.4 L |
| Maximum Sample Load | 227 kg |
| Heating Rate (no load) | 0–870 °C in ≤120 min |
| Door Opening Mechanism | Gas Spring-Assisted Upward-Lifting |
| Safety Interlock | Automatic Power Cut-off Upon Door Opening |
| Heating Element Embedment | Refractory Cement |
| Floor Lining | Silicon Carbide Hearth |
| Base Support | Refractory Brick Bed |
| Structural Frame | Welded Steel Stand (Standard) |
| Controller | External (Not Included) |
| Electrical Connection | Required External Wiring |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | F47900 (2 L) / F48000 (5.8 L) |
| Temperature Range | 100–1200 °C |
| Chamber Volume | 2 L or 5.8 L |
| Heating Element Layout | Dual-side mounted |
| Max. Operating Temperature | 1200 °C |
| Rear Port Diameter | 9.5 mm |
| Control Options | A1 (single-setpoint), B1 (delayed ramp), C1 (8-segment single program), D1 (16-segment × 4 programs, RS232 interface) |
| Venting | Integrated exhaust port |
| Construction | Heat-treated ceramic chamber lining |
| Compliance | Designed for GLP-compliant thermal processing in analytical and materials laboratories |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | F6000 |
| Temperature Range | 100–1200 °C |
| Chamber Volume | 15 L |
| Heating Element Layout | Top, Bottom, Left & Right Walls |
| Standard Exhaust Port | 0.95 cm Diameter |
| Door Safety Interlock | Yes |
| Thermocouple Fault Protection | Yes |
| Control Options | A1 (Single Setpoint), B1 (Setpoint + Ramp Delay), C1 (8-Step Single Program), D1 (4 × 16-Step Programs with RS232) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | FD1500 |
| Temperature Range | 100–1200 °C |
| Chamber Volume | 2.2 L |
| Heating Elements | 4 independent embedded in refractory cement |
| Safety Features | Door-activated power cutoff, dual overtemperature protection (mechanical relay + thermocouple fault detection), adjustable audible alarm |
| Interface Options | B1 (single-setpoint digital controller with ramp delay) or C1 (8-segment programmable digital controller) |
| Rear Port | 0.95 cm diameter for external temperature monitoring |
| Construction | Refractory brick-lined chamber with firebrick door seal |
| Power Cord | Included |
| Compliance | Designed for GLP-compliant weight loss and ashing workflows per ASTM E1868, ISO 1171, and USP <281> |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | FH40G |
| Instrument Class | Dose Rate / Ambient Dose Equivalent Rate Meter |
| Form Factor | Portable |
| Measurable Radiation Types | X-ray, Gamma (γ), Neutron (n), Alpha (α), Beta (β) |
| Detector Types Supported | Scintillation, GM Tube, Ionization Chamber, Proportional Counter, He-3 Neutron Detector |
| Measurement Quantities | Ambient Dose Equivalent Rate H*(10), Personal Dose Equivalent Hₚ(10), Contamination (Bq/cm²), Count Rate (cps) |
