| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Models | 42i, 42i-HL, 42i-TLE, 42i-LS |
| Measurement Principle | Chemiluminescence Detection (CLD) |
| Detection Range (42i) | 0–100 ppm / 0–150 mg/m³ |
| Zero Noise (42i) | 0.20 ppb RMS (60 s avg) |
| LOD (42i) | 0.40 ppb (60 s avg) |
| Zero Drift (24 h) | <0.40 ppb |
| Span Drift (24 h) | ±1% of full scale |
| Detection Range (42i-HL) | 0–5000 ppm / 0–7500 mg/m³ |
| Zero Noise (42i-HL) | 25 ppb |
| LOD (42i-HL) | 50 ppb |
| Detection Range (42i-TLE) | 0–1000 ppb / 0–2000 µg/m³ |
| Zero Noise (42i-TLE) | <25 ppt RMS (120 s avg) |
| LOD (42i-TLE) | 50 ppt (120 s avg) |
| Detection Range (42i-LS) | 0–500 ppm / 0–750 µg/m³ |
| Zero Noise (42i-LS) | <0.005 ppm RMS (120 s avg) |
| LOD (42i-LS) | 0.01 ppm (60 s avg) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | 48i |
| Configuration | Online Gas Analyzer |
| Target Analyte | Carbon Monoxide (CO), Single-Component |
| Measurement Range | 0–1 to 0–10,000 ppm (also available in mg/m³ equivalents) |
| Response Time (T90) | 60 s (with 30-s averaging) |
| Zero Drift (24 h) | < 0.1 ppm |
| Span Drift (24 h) | ±1% of full scale |
| Zero Noise | 0.02 ppm RMS (30-s average) |
| Limit of Detection | 0.04 ppm |
| Linearity Error | < ±1% of reading across full range |
| Data Storage | Flash memory with expanded capacity |
| Connectivity | Ethernet-enabled for remote access and control |
| Display | High-resolution backlit LCD with multi-tier menu interface |
| Soft-key Customization | User-definable function keys for rapid navigation |
| Compliance | Designed to meet EPA Performance Specification PS-1 (for ambient CO monitoring), ISO 9001-certified manufacturing, supports GLP/GMP data integrity requirements (audit trail, user authentication, electronic signature readiness per 21 CFR Part 11) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 49i |
| Pricing | Upon Request |
| Measurement Principle | UV Photometry (254 nm) |
| Detection Range | 0–200 ppm / 0–400 mg/m³ (selectable dual-range or auto-ranging) |
| Zero Noise | 0.25 ppb RMS (60-sec average) |
| Limit of Detection | 0.50 ppb |
| 24-hr Zero Drift | <1.0 ppb |
| Monthly Span Drift | <1% of full scale |
| Response Time (T90) | ≤20 seconds |
| Compliance | EPA EQOA-01, ISO 13964, ASTM D5012, US EPA Reference Method for O₃ |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 49i |
| Instrument Type | Online Continuous Monitor |
| Measurement Range | 0–0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ppm |
| Lower Detection Limit | 0.5 ppb |
| Response Time (T₉₀) | 20 s |
| Zero Drift (24 h) | <1.0 ppb |
| Span Drift (30 days) | <1% of full scale |
| Resolution | 1.0 ppb |
| Zero Noise | 0.25 ppb RMS (60-s averaging) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 49i-PS |
| Instrument Type | Online Calibrator |
| Measurement Range | 0–0.05, 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 ppm |
| Detection Limit | 1.0 ppb |
| Response Time | 20 s |
| Zero Drift | 0.25 ppb RMS (60-s averaging) |
| Resolution | 1.0 ppb |
| Ozone Source Output | 0.25–1.000 ppm at 3–4 L/min |
| Ozone Source Stability | ±4 ppb or ±1% of reading (whichever is lower) |
| Linearity | ±1% of full scale |
| Accuracy | ±1.0 ppb |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 5020i |
| Measurement Principle | Pulsed Ultraviolet Fluorescence (PUVF) |
| Measured Parameter | Ambient Air Sulfate Aerosol Mass Concentration (as SO₄²⁻) |
| Range | 0–5, 10, 25, 50, or 100 μg/m³ (user-selectable) |
| Zero Noise | 0.20 μg/m³ (15-min average) |
| Limit of Detection (LOD) | 0.5 μg/m³ (15-min average) |
| Span Drift (24 h) | ±1% of full scale |
| Response Time (t₉₀) | 90 seconds |
| Sample Flow Rate | 0.4–0.5 L/min |
| Operating Temperature | 20–30 °C |
| Denuder Lifetime | 30 days (replaceable) |
| Converter Lifetime | >6 months (replaceable) |
| Dimensions (Analyzer/Converter) | 426 mm (W) × 219 mm (H) × 584 mm (D) |
| Weight (Analyzer) | ~20 kg (detector module) |
| (Converter) | ~17 kg (sample conditioning module) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Model | 5030i (SHARP) |
| Measurement Method | Beta-ray attenuation with simultaneous optical scattering |
| Measured Parameters | PM₁₀ and PM₂.₅ |
| Measurement Ranges | 0–100, 0–1000, 0–2000, 0–3000, 0–5000, 0–10000 µg/m³ |
| Sampling Flow Rate | 16.67 L/min (1.0 m³/h) |
| Minimum Detection Limit | 1 µg/m³ (1-hour average) |
| Accuracy | ±2 µg/m³ for concentrations <80 µg/m³ |
| Flow Stability | ±5% (calibrated against NIST-traceable diaphragm standards) |
| Data Output Interval | 1 second |
| Beta Source | ¹⁴C, activity <3.7 MBq (<100 µCi) |
| Optical Source | IR LED, 6 mW, 880 nm |
| Heating System | Dynamic heated inlet (programmable temperature control) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 5030iQ and 5014iQ Next-Generation Ambient Air PM Continuous Monitors |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 51i |
| Pricing | Available upon Request |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | 0–1 to 0–10,000 ppmC |
| Zero Noise | 0.025 ppmC RMS (10-sec avg) |
| LOD | 0.050 ppmC (10-sec avg) |
| Zero Drift (24 h) | < 0.50 ppmC |
| Span Drift (24 h) | < 2% of full scale or 0.20 ppmC (whichever is greater) |
| T90 Response Time | 15 s (1-sec avg) |
| Accuracy | ±2.0% of reading or ±0.1 ppmC (whichever is greater) |
| Linearity | ±2% of span (10–150% of span) |
| Sample Flow Rate | 0.75–1.50 L/min |
| Combustion Air Flow | 150–300 mL/min |
| Hydrocarbon-Free Air Flow | 10–35 mL/min (H₂) or 50–120 mL/min (H₂/He mixture) |
| Operating Temperature | 15–35 °C |
| Power Supply | 100/115/220–240 VAC ±10%, 50/60 Hz, 420 W |
| Dimensions (W×H×D) | 425 × 219 × 584 mm |
| Weight | 22.7 kg |
| Output Options | Isolated 0–20 mA / 4–20 mA, RS232/RS485, TCP/IP Ethernet, 10 status relays, power-fail indication |
| Input Options | 16 digital inputs (standard), 8 channels 0–10 VDC analog inputs (optional) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 55i |
| Detection Principle | Back-Flush Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Measurement Range Options | 0–5 / 50 / 500 ppm, 0–10 / 100 / 1000 ppm, 0–20 / 200 / 2000 ppm, or 0–50 / 500 / 5000 ppm (as propane-equivalent NMHC) |
| LOD (300-s avg) | 0.050 ppm for CH₄ and NMHC |
| Zero Noise | 0.025 ppm RMS |
| Response Time (t₉₀) | ~70 s |
| Precision | ±2.0% of reading or ±50 ppb (whichever is greater) |
| Linearity | ±2% of span (10–100% full scale) |
| Sample Flow Rate | ≥0.5 L/min |
| Carrier Gas | N₂, 25–50 mL/min |
| Hydrogen Fuel Gas | 25–50 mL/min (or 100–150 mL/min H₂/He blend) |
| Air for FID | 275–350 mL/min |
| Operating Temperature | 15–35 °C |
| Power | 100–240 VAC ±10%, 50/60 Hz, 420 W |
| Dimensions | 42.5 × 21.9 × 58.4 cm (W×H×D) |
| Weight | 27.2 kg |
| Data Output | Analog (0–20/4–20 mA), RS232/RS485, TCP/IP, 10 relay status channels, power-fail indicator |
| Digital Inputs | 16-bit standard |
| Analog Inputs | 8–10 V (optional) |
| Internal Storage | Flash memory |
| Connectivity | Ethernet port for remote control, data export, and firmware updates |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 5800 VOCs CEMS |
| Detection Principle | Gas Chromatography–Flame Ionization Detection (GC-FID) |
| Instrument Type | Online Continuous Analyzer |
| Typical Configuration | Multi-component VOC Analyzer |
| Target Compounds | Up to 90 Volatile Organic Compounds |
| Resolution | 0.05 ppm |
| Accuracy | ±1% of full scale or ±0.1 ppm (whichever is greater) |
| Response Time | 1 minute (for methane/non-methane hydrocarbons) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Gas Chromatography |
| Mass Range | 1.2–1100 amu |
| Resolution | Unit Mass Resolution across Full Mass Range (EI Full Scan) |
| Instrument Detection Limit (IDL) | ≤2 fg (octafluoronaphthalene, 1 pg/µL) |
| Sensitivity | Unit mass resolution maintained across entire mass range |
| Scan Speed | 20,000 u/s |
| Sample Introduction | Online Cryogenic Thermal Desorption with Dual-Trap Architecture |
| Detection Limits | ≤0.02 ppb (propylene, C₂–C₅), ≤0.01 ppb (benzene, C₆–C₁₂ |
| Analysis Cycle Time | ≤60 min |
| GC Oven Temperature Range | 3 °C above ambient to 450 °C (0.1 °C control precision) |
| Pressure Control | Electronic Pneumatic Control (EPC), 0–1000 kPa, ±0.001 psi accuracy |
| Carrier Gas | Ultra-high-purity helium (99.9995%) |
| Data System | Embedded industrial PC (Intel CPU, 32 GB RAM), fully automated 7×24 operation with self-calibration, aging, and diagnostic routines |
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | 88881004 |
| Speed Range | Adjustable, Typically 2–80 rpm |
| Construction | Corrosion-Resistant Anodized Aluminum Frame with Stainless Steel Rollers |
| Environmental Rating | Suitable for Humid Environments and CO₂ Incubators (5–95% RH, 5–50 °C) |
| Tube/Bottle Compatibility | Adjustable Roller Spacing for Tubes (10–50 mm OD) and Bottles (up to 250 mL) |
| Stacking Capability | Dual-unit vertical stacking supported via optional stack kit |
| Timer Function | Integrated digital timer (0.1–99.9 h) with auto-shutoff |
| Remote Control | Optional IR remote for operation inside incubators |
| Sealing Integrity | Includes silicone O-rings for secure, wobble-free rotation of capped tubes |
| Warranty | 90-day limited warranty from date of shipment per Thermo Fisher’s standard Terms and Conditions |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | alpha-CON2000 |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | alpha-DO2000 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | alpha-pH2000D |
| Pricing | Upon Request |
| pH Range | −2.00 to 16.00 pH |
| pH Resolution/Accuracy | 0.01 pH / ±0.01 pH |
| Supported Buffer Standards | pH 1.01, 4.01, 6.86, 7.00, 9.00, 9.18, 10.01 |
| ORP Range | 0–100% or −2000 to +2000 mV |
| ORP Resolution/Accuracy | 0.1% of full scale or 1 mV / ±2 mV |
| Temperature Range | 0–100 °C |
| Temperature Resolution/Accuracy | 0.1 °C / ±0.5 °C |
| ATC Sensor | 300 Ω NTC thermistor |
| Control Modes | On/Off, Proportional (P), Proportional-Integral-Derivative (PID) |
| Power Supply | 80–250 VAC, 48–62 Hz or DC |
| Enclosure Size | 1/2 DIN (144 mm × 144 mm) |
| Ingress Protection | NEMA 4X |
| Mounting | Panel-mount (with optional wall-mount bracket kit) |
| Analog Outputs | Two isolated 0/4–20 mA outputs (configurable for pH/ORP and temperature) |
| Relay Functions | Dual control relays with adjustable hysteresis (0–2000 s delay), HOLD mode, cleaning cycle relay, password-protected configuration |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Czech Republic |
| Model | Apreo ChemiSEM |
| Instrument Type | Floor-standing High-Resolution FE-SEM |
| Electron Gun | Schottky Thermal Field Emission |
| Secondary Electron Resolution | 0.7 nm @ 30 kV |
| Backscattered Electron Resolution | 0.7 nm @ 30 kV |
| Magnification Range | 50× – 1,000,000× |
| Accelerating Voltage | 200 V – 30 kV |
| Landing Energy Range | 20 eV – 30 keV |
| Maximum Sample Size at 10 mm WD | 3 mm (min. mag. 29×) |
| Chamber Ports | 18 |
| Stage Travel | X = 110 mm, Y = 110 mm, Z = 65 mm, Tilt = −15° to +90°, Rotation = 360° continuous |
| Standard Detector System | Trinity In-lens Detection System (T1, T2, T3), TD, DBS |
| Optional Detectors | DBS-GAD, Low-Vacuum SE Detector, STEM 3+ Segmented Detector (BF/DF/HADF/HAADF), IR CCD, Thermo Scientific™ Nav-Cam™ Navigation Camera |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic Production |
| Model | Apreo |
| Instrument Type | Floor-Model High-Performance SEM |
| Electron Gun Type | Cold Field Emission (CFEG) |
| Microscope Class | Ultra-High-Resolution Field-Emission SEM |
| Secondary Electron Resolution | 1.0 nm at 1 kV (in-lens detection, no beam deceleration or monochromator) |
| Accelerating Voltage Range | 200 V – 30 kV |
| Backscattered Electron Resolution | ≤1.5 nm at 30 kV (T1 in-lens BSE detector) |
| Chamber Configuration | Triple EDS/WDS port capability |
| Vacuum System | Dual-mode (High Vacuum & Variable Pressure up to 500 Pa) |
| Software Platform | xT User Interface with SmartSCAN™, Drift Compensation Frame Integration (DCFI), and Charge Filtering Algorithms |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AQ4001 |
| Instrument Type | Benchtop/Field-Deployable Water Quality Analyzer |
| Key Components | AQ4000 Multi-Parameter Colorimeter, pH Meter, Conductivity Meter, Turbidimeter, Reagent Kits, Portable Carry Case |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | Aquilos 2 Cryo-FIB |
| Price Range | USD 1.3–2.0 million (FOB) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | LCM |
| Separation Method | Automated |
| Dimensions | Compact design (32% smaller footprint vs. comparable LCM platforms) |
| Laser Configuration | Dual-solid-state laser system (IR capture + UV cutting) |
| Software | Arcturus LCM Software (5-step workflow, full instrument control, QC-integrated imaging, audit-ready metadata logging) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Arke SO3 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) for Sulfur Trioxide |
| Accuracy (Indicated Value Error) | ±0 ppm |
| Repeatability | <0.2 ppm (300-s average) |
| Response Time (T90) | <15 s |
| Long-Term Stability (Zero Drift, 24 h) | <0.5 ppm |
| Span Drift | ≤2% of full scale |
| Linearity | ±1% of full scale |
| H₂O Interference | <1×10⁻⁵ (relative to SO₃ signal) |
| SO₂ Interference | <1×10⁻⁴ (relative to SO₃ signal) |
| Measurement Range | 0–200 ppm |
| Zero Noise (300-s avg) | 0.2 ppm |
| Limit of Detection (LOD, 300-s avg) | 0.4 ppm |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | ASE350 |
| Extraction Type | Solid-phase accelerated solvent extraction (ASE) |
| Pressure Range | 1500 psi |
| Temperature Range | Up to 200 °C |
| Flow Rate | 70 mL/min |
| Extraction Cell Volumes | 1, 5, 10, 22, 34, 66, and 100 mL |
| Solvent Options | Up to 3 solvents programmable per method |
| Solvent Consumption | <50 mL per 20 g sample (typical) |
| Automation Capacity | Up to 24 samples unattended |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | BF51732 / BF51841 / BF51842 |
| Instrument Type | Box Furnace |
| Temperature Range | 100 °C to 1200 °C |
| Door Mechanism | Vertically Lifting Lid |
| Chamber Volume | 16.4 L |
| Control System | Integrated Digital Controller |
| Voltage/Frequency | 208–240 V, 50/60 Hz |
| Power Rating | 4500 W |
| Internal Dimensions (H×D×W) | 177.8 × 279.4 × 330.2 mm |
| Transport Weight | Approx. 130 kg |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Biofuge Stratos |
| Instrument Type | Benchtop Centrifuge |
| Category | High-Speed Refrigerated Centrifuge (>30,000 rpm equivalent performance) |
| Max Speed | 23,300 rpm |
| Max RCF | 50,377 × g |
| Max Capacity | 4 × 180 mL |
| Temperature Range | −9 °C to +40 °C |
| Dimensions (H×W×D) | 395 × 640 × 595 mm |
| Drive System | Brushless Motor with Spindle Shaft Architecture |
| Acceleration/Deceleration Steps | 9 each |
| Programmable Protocols | 9 user programs + 1 pre-cool program |
| Noise Level | <60 dB(A) |
| Power Consumption | 1400 W (including 900 W refrigeration system) |
| Safety | Dual interlocked door system, real-time electronic imbalance detection, automatic rotor recognition |
| Control System | EASYcontrol™ II microprocessor-based interface |
| Rotor Compatibility | Fixed-angle, swing-bucket, microplate, and high-capacity vertical rotors (including bio-containment-certified variants) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | CellInsight CX7 LZR Pro |
| Pricing | Available Upon Request |
| Camera | Back-illuminated sCMOS with 95% peak QE and -20°C cooling |
| Objective Lens | Olympus X-line |
| Imaging Modes | Widefield + Confocal (laser-based) |
| Fluorescence Channels | 7-color laser-excited |
| Brightfield Channels | 5-color |
| Confocal Channels | 7-color |
| Excitation Wavelengths | UV to NIR (7 lines) |
| Plate Compatibility | SBS-standard microplates (6–1536-well) and microscope slides |
| Software | HCS Studio 5.0 with >40 validated life science applications |
| Auto-focus | Dual-mode (software + laser-based), label-agnostic |
| Throughput Features | EurekaScan Finder dual-pass detection for spheroids/tissues/rare events |
| Environmental Control Support | Optional live-cell incubation modules |
| Plate Handling | Compatible with Orbitor RS robotic plate handler (optional) |
| Regulatory Status | For Research Use Only (RUO) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Equipment |
| Model | Mono Direct / Maxi Direct |
| Instrument Type | Magnetic Stirrer |
| Maximum Stirring Volume | 3 L (Mono Direct) / 5 L (Maxi Direct) |
| Speed Range | 130–1200 rpm (Mono Direct) / 80–2000 rpm (Maxi Direct) |
| Temperature Operating Range | −10 °C to +40 °C |
| Enclosure Rating | IP64 (Maxi Direct only) |
| Construction | Powder-coated or seamless stainless steel housing |
| Control Interface | Analog knob (Mono Direct) / Digital LCD with microprocessor control (Maxi Direct) |
| Compliance | Designed for GLP-compliant environments |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Mobil 10 w/o Controller / Mobil 25 w/o Controller |
| Stirring Volume Capacity | 25 L |
| Speed Range | 100–1000 rpm |
| Temperature Operating Range | −10 °C to +121 °C |
| IP Rating | IP68 (Mobil 25 only) |
| Construction Material | Seamless Stainless Steel (316L-grade equivalent) |
| Safety Certification | CE, RoHS, IEC 61000-6-3/6-4 compliant |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Models | SP88857106 / SP88854105 / SP88857105 |
| Instrument Type | Magnetic Hotplate Stirrer |
| Maximum Stirring Volume | 1 L / 4 L / 6 L |
| Speed Range | 50–1500 rpm |
| Temperature Range | 30–300°C (Aluminum Plate, 7″) / 30–400°C (Ceramic Plate, 10″) / 30–540°C (Ceramic Plate, 4″ & 7″) |
| Heating Time to Max Temp (No Load) | ≤8 min |
| Temperature Accuracy @100°C | ≤±5°C (center of top plate) |
| Temperature Uniformity @100°C | ≤±2°C (center of top plate) |
| Top Plate Material Options | Ceramic or Anodized Aluminum |
| Max Load Capacity | 11.3 kg (25 lbs) |
| Power Supply | 220–240 V AC, 1.6–4.6 A |
| Certifications | cCSAus, CE |
| Warranty | 3 years |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured under Thermo Fisher technology transfer) |
| Model | IQLAAAGADHFAMJMBIQ |
| Pricing | Available upon Request |