Thermo Fisher Scientific
Filter
Showing 31–60 of 409 results
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA (Manufactured Globally per ISO 13485) |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | iBlot® 2 |
| Automation Level | Semi-Automated Western Blot Transfer System |
| Power Supply | Integrated 24 V DC internal power module |
| Dimensions (W × D × H) | 29.5 × 24.1 × 19.7 cm |
| Weight | 6.8 kg |
| Pre-Programmed Protocols | 12 built-in (including PVDF/Nitrocellulose, 1D/2D gels, low-MW/high-MW proteins) |
| Custom Protocol Storage | Up to 20 user-defined methods |
| Touchscreen Interface | 4.3-inch capacitive LCD with GLP-compliant audit trail logging |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Qubit 3.0 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured under Thermo Fisher specifications) |
| Model | Invitrogen™ EVOS™ S1000 |
| Pricing | Available upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | KingFisher Duo |
| Magnetic Head Configurations | 1×6 and 1×12 |
| Integrated Thermal Block | Yes |
| Regulatory Status | CE-IVD, FDA 510(k)-cleared for IVD use (when used with approved kits) |
| Compliance | ISO 13485–certified manufacturing |
| Software | Thermo Fisher Connect™ compatible |
| Data Integrity | Audit trail, user access control, electronic signatures per 21 CFR Part 11 requirements |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | LS-I72 / LS-I201 |
| Temperature Range | Ambient +5 °C to 60 °C |
| Temperature Uniformity | ±0.1 °C (at 37 °C setpoint) |
| Temperature Fluctuation | ±0.5 °C |
| Capacity | 72 L / 201 L |
| Internal Dimensions (W×D×H) | 41.5×41.5×41.5 cm / 58.0×58.0×60.0 cm |
| External Dimensions (W×D×H) | 52.5×51.5×75.0 cm / 69.0×68.0×95.5 cm |
| Power Consumption | 0.4 kW / 0.6 kW |
| Weight | 35 kg / 47 kg |
| Electrical Supply | 1.2 A / 2 A |
| Control System | PID-based digital temperature controller with LED display |
| Interior Material | Stainless steel (AISI 304) |
| Door Opening Angle | 180° |
| Air Circulation | Natural convection |
| Safety Features | Independent over-temperature protection, short-circuit protection |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Magnetic Bead-Based Nucleic Acid Purification System |
| Automation Level | Dedicated Fully Automated Platform |
| Compatible Kit Format | MagMAX™-branded and third-party magnetic bead-based nucleic acid isolation kits |
| Onboard Protocol Storage | Preloaded, user-editable scripts |
| Standalone Operation | Yes (no PC required) |
| PC Connectivity | Optional USB or serial interface |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Dimensions (W × D × H) | Approx. 36 × 42 × 38 cm |
| Weight | ~25 kg |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | NanoDrop Eight |
| Optical Design | Dual-beam |
| Detector | CCD Array |
| Wavelength Range | 190–850 nm |
| Wavelength Automation | Fully Automatic |
| Spectral Bandwidth | ≤1.8 nm |
| Wavelength Accuracy | ±1 nm |
| Stray Light | ≤0.01% T |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Nunc™ 300 cm² |
| Sterilization | Gamma-irradiated, Non-pyrogenic |
| Surface Treatment | Tissue Culture-Treated (TC-treated) |
| Total Capacity / Working Volume | 1900 mL / 400 mL |
| Cap Options | Vent Cap (透气盖), Plug Seal Cap (密闭盖), Filter Cap (0.2 µm PES membrane) |
| Packaging | 1 flask per pack, 12 packs per case |
| Stackable Design | Yes |
| Ergonomic Grip | Molded finger groove for secure handling |
| Surface Area | 300 cm² |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 2295 |
| Instrument Type | Online Analyzer |
| Detection Range | 0.2–50 ppm PO₄³⁻ (auto-ranging) |
| Reagent Consumption | 0.2 mL per reagent per analysis |
| Sample Temperature Control | Heated to 25 °C for low-temperature samples |
| Light Source | High-stability LED (no filters or optical fibers) |
| Pump Maintenance Interval | Every 6 months |
| Display | Backlit LCD with full status and measurement data |
| Data Storage | 31 days of calibration & analysis logs (timestamped, parameter-rich) |
| Enclosure Rating | NEMA 4 |
| Power Input | 100–240 VAC, 50–60 Hz |
| Installation | Panel-mount or wall-mount compatible |
| Auto-Restart Function | Configurable 30-minute timeout after STOP command |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 2295 |
| Instrument Type | Online Analyzer |
| Measurement Range | 0.2–50 ppm PO₄³⁻ (auto-ranging) |
| Reagent Consumption | 0.2 mL per reagent per analysis cycle |
| Sample Temperature Control | Integrated heater maintains sample at 25 °C ± 1 °C |
| Light Source | Solid-state LED (no filters, no optical fibers, maintenance-free) |
| Pumping System | High-reliability peristaltic pump with specialized tubing (replacement interval: 6 months) |
| Display | Backlit LCD with real-time status, measurement, and diagnostic information |
| Data Storage | 31-day internal log of calibration events, analysis results, timestamps, and system diagnostics |
| Enclosure Rating | NEMA 4 (dust-tight, splash-resistant) |
| Power Input | 100–240 VAC, 50–60 Hz |
| Auto-Restart Function | Configurable 30-minute timeout after STOP command |
| Sampling Mode | Optional grab-sample analysis capability |
| Mounting | Panel-mount or wall-mount compatible |
| Compliance | Designed for continuous operation in regulated industrial environments (supports GLP/GMP-aligned data integrity practices) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 23246 |
| Format | Ready-to-use liquid reagent |
| Detection Wavelength | 595 nm |
| Sample Volume | 10 µL (microplate format) |
| Incubation Time | 10 min at room temperature |
| Linear Range | 2–1500 µg/mL (with 1% Triton X-100 or NP-40) |
| Compatibility | Compatible with ≥1% nonionic detergents including Triton X-100, NP-40, Tween-20, and CHAPS |
| Standard Curve Required | Yes (BSA-based, supplied separately or user-prepared) |
| Measurement Platform | UV-Vis spectrophotometer or microplate reader |
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | A36228 |
| Format | Spin-column-based silica-membrane purification |
| Endotoxin Level | <1 EU/µg |
| Yield | Up to 1.5 mg high-purity plasmid DNA per prep |
| Processing Time | ~30 min |
| Required Equipment | Vacuum manifold (e.g., FastVac) or centrifuge (with optional adapter) |
| Buffer System | Colorimetric lysis and neutralization buffers |
| Intended Use | Transfection-grade plasmid isolation from E. coli cultures (up to 250 mL) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Radiation and Contraband Detection System |
| Model | RadEye CD |
| Detector Type | RadEye SX with NaI(Tl) Scintillation Detector |
| Measurement Capability | Simultaneous detection of concealed contraband (e.g., tobacco, explosives, alcohol) and radioactive materials |
| Measurement Range | 5–10 cps (background), 50–100 cps (contraband presence) |
| Sensitivity | ≥5 cps minimum detectable signal above background |
| Analysis Channels | Dual-channel spectral analysis |
| Typical Background Count Rate | 5 cps |
| Effective Measurement Time | 1 second per acquisition |
| Regulatory Compliance | Designed for customs, border security, and port-of-entry applications in accordance with IAEA TS-G-1.2 and ANSI N42.34 standards |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Model Variants | DXF40040V / DXF24040V / DXF32040V |
| Temperature Range | –10°C to –40°C |
| Internal Volume | 490 L (17.3 cu ft) |
| Vial Capacity | 32,000 × 2 mL |
| Shelf Load Capacity | 68 kg (150 lb) per Shelf |
| Insulation | 127 mm Polyurethane Foam |
| Refrigerant | R404A |
| Electrical | 230 V, 50 Hz, 12 A |
| Certifications | cULus, CE, UL, FDA Class I |
| Door Configuration | Single outer door, 5 independent inner doors (standard on DXF32040V) |
| Optional Backup | CO₂ or LN₂ cascade system |
| Data Output | Dry contacts (standard), PT100 probe (optional) |
| Warranty | Region-specific — contact local Thermo Fisher support |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Refrigeration Equipment |
| Models | REC3004V, REC7504V |
| Price Range | USD $12,500 – $37,500 (FOB US Port) |
| Temperature Range | 1°C to 8°C (factory preset at 4°C) |
| Uniformity | ±0.5°C across all shelves (under steady-state conditions) |
| Airflow | Positive-pressure forced-air circulation |
| Defrost System | Adaptive probe-controlled automatic defrost |
| Display Resolution | 0.1°C |
| Alarm Thresholds | High-temp alarm ≥ +5.5°C, Low-temp alarm ≤ +1.5°C |
| Construction | Cold-rolled steel interior & exterior with impact-resistant powder coating |
| Access Ports | Two 2″ (5.1 cm) diameter hinged access ports |
| Door Options | Sliding glass doors (REC7504V, 45.8 cu.ft.), keyed rotary doors with 90° spring-assisted opening (REC3004V) |
| Lighting | Internal lamp with independent switch (REC7504V), externally controlled lamp (REC3004V) |
| Power Outlets | GFCI-protected, moisture-resistant, fog-proof receptacles |
| Shelving | Adjustable epoxy-coated wire shelves |
| Mobility | Dual-swivel casters with locking mechanism |
| Refrigerant | Non-CFC, environmentally compliant (R-404A or R-507, per model configuration) |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Model | Legend Micro 17 / Legend Micro 17R / Legend Micro 21 / Legend Micro 21R |
| Max RCF | 17,000 × g / 21,000 × g |
| Max Speed | 13,300 rpm / 14,800 rpm |
| Capacity | 24 × 1.5 mL / 2.0 mL tubes |
| Drive System | Brushless frequency-sensing direct-drive motor |
| Temperature Range (Refrigerated models) | –9 °C to 40 °C |
| Noise Level | ≤56 dB(A) |
| Acceleration/Deceleration Time | 11–13 s |
| Safety Features | Automatic rotor recognition, lid interlock, imbalance detection, self-diagnostic system, electronic circuit protection |
| Compliance | IEC 61010-1, EN 61326-1 (EMC), FDA 21 CFR Part 11-ready software architecture |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model Numbers | 50135643, 50135648 |
| Instrument Type | Floor-Model Ultracentrifuge |
| Speed Range | Up to 150,000 rpm (Model-Dependent) |
| Maximum RCF | 1,048,000 × g |
| K-Factor Range | As low as 14–35 (Rotor-Dependent) |
| Noise Level | <45 dBA |
| Footprint | 0.53 m² (5.7 ft²) |
| Rotor Compatibility | Fixed-angle, swinging-bucket, vertical rotors |
| Tube Capacity | 0.2–30 mL |
| Sample Types | Viruses (HIV, SRSV, rotavirus), organelles (ribosomes, mitochondria, microsomes), lipoproteins, nanoparticles, nucleic acids |
| Drive System | Brushless DC motor with imbalance detection and auto-shutdown |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Model | Sovall X4R Pro-MD |
| Configuration | Floor-standing or benchtop, refrigerated |
| Maximum RCF (fixed-angle) | >25,000 × g |
| Maximum RCF (swing-bucket) | >7,000 × g |
| Capacity | 1.6 L (4 × 400 mL) or 4 L (4 × 1000 mL) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | SPECTRONIC 200 |
| Instrument Architecture | Single-beam |
| Detector Type | Photodiode Array |
| Wavelength Range | 340 nm – 1000 nm |
| Wavelength Scanning | Motorized Auto-wavelength Selection |
| Spectral Bandwidth | < 4 nm |
| Wavelength Accuracy | ±1.0 nm (typical, per ASTM E275) |
| Stray Light | < 0.1% T at 340 nm (as measured per ISO 9050) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 3500 / 3500xL |
| Instrument Type | First-Generation Sanger Sequencer |
| Throughput | 368 samples/day |
| Read Length | 1000 bp |
| Accuracy | 99.99% |
| Reproducibility | 90% |
| Run Time | 1000 bp per 125 min |
| Capillary Configuration | 8-capillary (3500) or 24-capillary (3500xL), field-upgradeable |
| Laser Source | 505 nm solid-state, air-cooled |
| Temperature Control Range | 18–70 °C |
| Electrophoresis Voltage | up to 20 kV |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Product Type | Pre-cast Polyacrylamide Gel System |
| Gel Chemistries | Bis-Tris and Tris-Acetate |
| Format Sizes | Mini (8 × 8 cm) and Midi (8 × 13 cm) |
| Shelf Life | Up to 2 months at 4 °C |
| Electrophoresis Time | As low as 35 minutes |
| Compatible Staining | Coomassie, Silver, Fluorescent dyes |
| Transfer Efficiency | Enhanced for Western blotting |
| pH Range | Neutral (pH ~7.0) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Model | PrintMate AS |
| Capacity Options | 150 (2-slot), 450 (6-slot), 900 (12-slot) |
| Cassette Load per Slot | 75 |
| Input Mechanism | Rotary Magazine Feeding |
| Compatible Cassette Type | Standard 45°-angled plastic tissue cassettes |
| Printing Technology | Thermal Foil Transfer with High-Durability Ribbons |
| Barcode/QR Support | Code 128, Code 39, Data Matrix, QR Code |
| Character Set | Unicode-compliant (Latin, Cyrillic, Greek, CJK Unified Ideographs), Windows TrueType Fonts |
| Interface | HL7, ASTM LIS/HIS Integration |
| Compliance | ISO 15189, CLIA, CAP, FDA 21 CFR Part 11 (audit trail & electronic signature ready) |
| Optional Module | Smart Sorting Drawer System (100-cassette simultaneous collection) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 17i |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Chemiluminescence (NO–O₃ Reaction) |
| Measurement Modes | NO, NOₓ, Nₜ |
| NH₃ Quantification Method | Stainless-Steel Catalytic Converter-Based Conversion to NO |
| Output Signals | Analog (0–10 V / 4–20 mA), Digital (Ethernet) |
| Data Storage | Internal Flash Memory |
| Remote Access | Yes, via Local Area Network |
| Compliance | Designed for EPA Reference Method Compliant Monitoring (e.g., EQOA-0038), Supports GLP/GMP Audit Trail Requirements (via optional software logging) |
| Operating Environment | Indoor/Outdoor Enclosure Rated NEMA 4X |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions | 48.3 cm W × 17.8 cm H × 55.9 cm D (19″ Rack Mountable) |
| Weight | 22.7 kg |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 17i NH₃ Analyzer |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Chemiluminescence Detection (CLD) |
| Measurement Range | 0–50, 100, 200, 500, 1,000, 2,000, 10,000, 20,000 ppb |
| Alternate Units | 0–100, 200, 500, 1,000, 2,000, 5,000, 10,000, 20,000, 30,000 µg/m³ |
| Zero Noise | 0.5 ppb RMS (120-s averaging time) |
| Limit of Detection (LOD) | 1 ppb |
| Zero Drift (24 h) | ≤1 ppb |
| Span Drift (30 days) | ≤1% of full scale |
| Analog Outputs | Independent isolated 0–10 V or 4–20 mA outputs for NO, NO₂, NH₃, and NOₓ |
| Diagnostic Capability | Real-time status monitoring, remote performance diagnostics, built-in fault detection and logging |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 17i |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Chemiluminescence (NO + O₃ → NO₂* + hν) with Catalytic Conversion for NH₃ and NO₂ |
| Measurement Modes | NO, NOₓ, Nₜ |
| Output Signals | Analog (0–10 V / 4–20 mA), Digital (Ethernet), RS-232/RS-485 |
| Range Options | 0–50 to 0–20,000 ppb |
| Zero Noise | 0.5 ppb RMS (120 s averaging) |
| LOD | 1 ppb |
| Zero Drift (24 h) | ≤1 ppb |
| Span Drift (30 days) | ≤1% FS |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Industrial Process Analyzer |
| Model | 2102PH |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 310 Series |
| Temperature Range | 5°C above ambient to 50°C |
| Temperature Uniformity (at 37°C) | ±0.2°C |
| Temperature Accuracy | ±0.1°C |
| CO₂ Range | 0–20% |
| CO₂ Control Accuracy | Better than ±0.1% |
| Relative Humidity (at 37°C) | Ambient RH to 95% |
| Humidification Pan Capacity | 3.0 L (standard) |
| Internal Volume | 184.1 L |
| Internal Dimensions (W×H×D) | 544 × 681 × 508 mm |
| External Dimensions (W×H×D) | 663 × 978 × 627 mm |
| Input Pressure | 15 PSIG |
| CO₂ Sensor Type | Thermal Conductivity (T/C) or Infrared (IR) |
| Standard/Maximum Shelving | 4 / 17 shelves |
| Net Weight | 96 kg |
| Air Filtration | HEPA Filter, Class 100 Internal Environment |
| Control System | Enviro-Scan™ Microprocessor-Based Environmental Monitoring and Control System |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 3110 Series |
| Chamber Volume | 184.1 L |
| Water Jacket Capacity | 43.5 L |
| Temperature Range | Ambient +5°C to 55°C |
| Temperature Uniformity (at 37°C) | ±0.2°C |
| Temperature Accuracy | ±0.1°C |
| CO₂ Range | 0–20% |
| CO₂ Control Accuracy | Better than ±0.1% |
| O₂ Range | 1–20% |
| O₂ Sensor Type | Fuel Cell |
| Relative Humidity (at 37°C) | Ambient to 95% RH |
| Humidification Pan Capacity | 3.0 L |
| Internal Dimensions (W×H×D) | 544 × 681 × 508 mm |
| External Dimensions (W×H×D) | 668 × 1003 × 635 mm |
| Standard Shelving | 4 shelves (max 17) |
| Net Weight | 120 kg |
| HEPA Filtration | Class 100 internal environment |
| Power Input Pressure | 15 PSIG |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 3951 |
| Temperature Range | Ambient +5°C to 60°C |
| CO₂ Range | 0–20% |
| CO₂ Control Accuracy | ±0.1% |
| Temperature Uniformity (at 37°C) | ±0.3°C |
| Temperature Control Accuracy | ±0.1°C |
| Humidity Options | Off / Medium (>80%) / High (>90%) |
| Internal Volume | 821.2 L |
| Internal Dimensions (W×H×D) | 787 × 1524 × 686 mm |
| External Dimensions (W×H×D) | 965 × 2032 × 838 mm |
| Shelf Capacity | 5 standard / up to 27 stainless steel shelves |
| Total Shelving Area | 13.5 m² |
| Humidity Reservoir Volume | 15.1 L |
| CO₂ Sensor Type | Thermal Conductivity (T/C) |
| Input Gas Pressure | 15 PSIG |
| Heated Inner Glass Door | Yes |
| Dual External Port Access (Left/Right) | Yes |
| Power Fail Memory for Setpoints & Calibration Values | Yes |
| Automatic CO₂ Cut-off on Outer Door Opening | Yes |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 410i |
| Instrument Type | Online Analyzer |
| Target Analyte | CO₂ (single-component gas) |
| Measurement Range (Standard) | 0–200 ppm |
| Resolution | 0.2 ppm |
| Repeatability | ±1.0% of reading |
| Zero Drift (24 h) | ±1.0 ppm |
| Span Drift | <0.5% of reading per 24 hours |
| Linearity Error | ±1.5% of full scale |
| Response Time (t₉₀) | 90 seconds (typical average: 30 seconds) |
| Zero Noise (300 s avg) | 0.1 ppm RMS |
| Detection Limit (Standard Range) | 1 ppm |
| Warm-up Time | <1 hour to operational stability |