| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Breeze™ 2 HPLC |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-Purpose Analytical & Semi-Preparative Use |
| Flow Rate Range | Analytical mode: 0–10 mL/min |
| Semi-preparative mode | 0–22.5 mL/min |
| Maximum Pressure | 6000 psi |
| Autosampler Capacity | 96 positions |
| Injection Volume Range | Analytical: 0.1–100 µL |
| Semi-preparative | 0–10 mL |
| Temperature Control | Optional column oven (configurable per system setup) |
| Wavelength Ranges | UV-Vis detector (2489): 190–700 nm |
| PDA detector (2998) | 190–800 nm |
| Fluorescence detector (2475) | Excitation 200–890 nm, Emission 210–900 nm |
| Data Acquisition Rate | 80 Hz |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Charged Aerosol Detector |
| Pricing | Upon Request |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Model | DESI XS |
| Compatibility | SELECT SERIES Cyclic IMS, SYNAPT XS, Xevo G2-XS QTof |
| Ionization Principle | Desorption Electrospray Ionization (DESI) |
| Environmental Sealing | Partially Enclosed Housing |
| Integrated Imaging | Side-View Camera for Spray-Sample Alignment |
| Motion Control | Stepper-Motor Stage with S-Curve Acceleration Algorithm |
| Automation | Auto-shutoff for Solvent Gas & High Voltage |
| Software Integration | HDI™ Software for High-Resolution Mass Spectrometry Imaging |
| Regulatory Context | Designed for GLP/GMP-compliant imaging workflows |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | e-SAT/IN |
| Condition | Refurbished & Fully Tested |
| Regulatory Status | CE-marked, Compliant with IEC 61000-6-3 EMI Standards |
| Interface | RS-232 / TTL-compatible digital output |
| Input Range | ±10 V analog input, 12-bit resolution |
| Sampling Rate | Up to 1 kHz (typical in legacy HPLC system integration) |
| Power Supply | +5 V DC (supplied via host chromatograph interface) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Empower 3 |
| Software Type | Chromatography Data System (CDS) |
| Regulatory Compliance | FDA 21 CFR Part 11, Annex 11, GLP/GMP-ready |
| Architecture | Modular, Scalable, Client-Server & Standalone Deployment Options |
| Instrument Control | ACQUITY UPLC, Alliance HPLC, Third-party HPLC/GC/PDA/MS Systems |
| Database | Embedded Relational SQL Database (Microsoft SQL Server) |
| Integration Capability | LIMS, ERP, ELN, and Enterprise IT Infrastructure |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Investigator SFC System |
| Application Level | Laboratory Grade |
| Instrument Type | Semi-Preparative Supercritical Fluid Chromatography System |
| Flow Rate Range | Up to 15 mL/min |
| Column Capacity | Up to 10 analytical columns or 6 preparative columns |
| Integrated Autosampler | Waters Alias |
| Software Platform | SuperChrom |
| Optional Detectors | 2998 Photodiode Array (PDA) Detector, 2424 Evaporative Light Scattering (ELS) Detector |
| Dimensions (H×L×W) | 92 cm × 98 cm × 68 cm |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | ionKey/MS |
| Category | Mass Spectrometry Integrated Microfluidic Separation Platform |
| Compatibility | Designed for Waters Xevo TQ-S, Xevo G2-XS QTof, and other Waters MS platforms with iKey-compatible ion sources |
| Column Format | Monolithic 150 µm ID microfluidic channel packed with 1.7 µm BEH particles |
| Equivalent Chromatographic Performance | Comparable to 2.1 mm ID UPLC columns |
| Sensitivity Enhancement | Up to 5–10× vs. conventional 2.1 mm ID UPLC-MS |
| Solvent Consumption | <5 µL/min typical flow rate |
| Interface Type | Integrated electrospray ionization (ESI) source with embedded heater, e-cord™ electronics, and plug-and-play fluidic/electrical coupling |
| Brand | Waters |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Models Supported | TQ Series (TQ-S, TQ-XS, TQ-Xe), 2695 Separations Module, e2695 Separations Module, Acquity UPLC Systems, Arc HPLC Systems, I-Class UPLC Systems, SFC Systems |
| Service Fee Range | USD 1,400–2,800 per incident (excl. parts) |
| Technician Experience | 5–10 years on Waters platforms |
| Response Time | ≤24 hours for emergency support |
| Geographic Coverage | Sichuan, Chongqing, Yunnan, Guizhou |
| Compliance Scope | Supports GLP/GMP-aligned maintenance documentation, ASTM E2500-based verification traceability, and ISO/IEC 17025-compliant service records |
| Software & Data Handling | Compatible with Empower 3, MassLynx, and UNIFI |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported LIMS Software |
| Model | NuGenesis |
| Pricing | Available Upon Request |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | PATROL UPLC |
| Instrument Type | Real-time In-line/At-line UPLC-based PAT System |
| Regulatory Alignment | Designed for FDA QbD and ICH Guidelines |
| Deployment Mode | Integrated Process Analytical Technology (PAT) Platform |
| Operational Architecture | Fully Automated, 24/7 Unattended Operation |
| Diagnostics | On-board Self-Diagnostics with Remote Monitoring Capability |
| Connectivity | Ethernet/IP-enabled for Distributed Control System (DCS) and Manufacturing Execution System (MES) Integration |
| Software Compliance | Supports 21 CFR Part 11 Audit Trail, Electronic Signatures, and GLP/GMP Data Integrity Requirements |
| Sample Introduction | Configurable for At-line Flow-Through Cells or Direct In-line Probes (with Optional Valving & Filtration Modules) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Prep 100q SFC |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative SFC System |
| Flow Rate Range | Up to 100 mL/min |
| Mobile Phase | CO₂-based supercritical fluid (co-solvent compatible) |
| Fraction Collection | Automated open-loop collection with UV- or MS-triggered modes |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Separation Mode | Chiral and achiral preparative separations |
| Sample Scale | Milligram- to gram-scale purification |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Prep 150 |
| Application Level | Laboratory-grade |
| Instrument Type | High-pressure preparative LC |
| Pump Configuration | Binary or Quaternary (low-pressure solvent selection or high-pressure gradient mixing up to 150 mL/min) |
| Detector Options | 2489 UV/Vis or 2998 Photodiode Array (PDA) |
| Column Compatibility | Up to 50 mm internal diameter |
| Sample Load Range | Milligram- to gram-scale purification |
| Software | ChromScope™ for method development, fraction simulation, and GLP-compliant data handling |
| Compliance | Designed to support 21 CFR Part 11–ready workflows with audit trail and electronic signature capability (when configured with appropriate IT infrastructure) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Prep SFC 150 AP System |
| Instrument Type | Preparative |
| Detector Types | None |
| Maximum Pressure | Not Specified |
| Flow Rate Range | Not Specified |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Prep SFC 150 Mgm |
| Type | Preparative |
| Maximum CO₂ Flow Rate | 150 mL/min |
| Modifier Flow Range | Up to 150 mL/min |
| Fraction Collection Positions | 6 × 2 L |
| Operating System | Windows 10 |
| Control Software | Waters ChromScope 2.0 SFC |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Preparative Supercritical Fluid Chromatography (SFC) System |
| Model Variants | 80, 200, 350 |
| Application Level | Laboratory-Scale Purification |
| Regulatory Context | Designed for GLP-compliant workflows and compatible with FDA 21 CFR Part 11–enabled software environments |
| Compliance Framework | Supports ASTM D7894–21 (Standard Guide for SFC Method Development), ISO 17025–2017 (Testing Laboratory Competence), and USP <621> Chromatography guidelines |
| Software Platform | SuperChrom v3.x (with audit trail, electronic signatures, and method versioning) |
| Detection | UV-Vis absorbance detection (dual-wavelength capability) |
| Fraction Collection | Automated, timed or peak-triggered, with solvent compatibility up to 100% CO₂-expanded liquids and polar modifiers (e.g., methanol, ethanol, isopropanol) |
| Back Pressure Control | Active Automatic Back Pressure Regulator (ABPR) with ±0.2 bar pressure stability |
| Solvent Delivery | Dual-pump architecture — primary CO₂ pump (supercritical phase delivery) and auxiliary modifier pump (liquid-phase co-solvent gradient) |
| System Architecture | Modular, rack-mounted configuration with integrated safety interlocks, CO₂ phase monitoring, and real-time density compensation |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Model | RADIAN ASAP |
| Ionization Principle | Atmospheric Pressure Solid Analysis Probe (ASAP) |
| Mass Analyzer | Single Quadrupole |
| Detection Mode | Full Scan / Selected Ion Monitoring (SIM) |
| Sample Introduction | Direct Solid & Liquid Analysis |
| Software Platform | LiveID, IonLynx, OpenLynx |
| Compliance Support | FDA 21 CFR Part 11 (audit trail, electronic signature), GLP/GMP-ready workflows |
| Dimensions | Compact benchtop footprint (< 60 cm width) |
| Typical Analysis Time | < 30 seconds per sample |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SELECT SERIES Cyclic IMS |
| Pricing | Upon Request |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | SELECT SERIES MRT |
| Mass Analyzer Type | Multi-Reflecting Time-of-Flight (MRT-TOF) |
| Instrument Class | High-Resolution Accurate-Mass (HRAM) LC-MS/MS System |
| Application Scope | Universal (Life Sciences, Clinical Research, Forensics, Materials Surface Analysis) |
| Pressure Range | Not Applicable (Vacuum-operated analyzer) |
| Ion Sources Supported | DESI XS, SELECT SERIES MALDI, Electrospray (ESI), APCI |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Waters SQD |
| Mass Range | m/z 50–1000 |
| Ionization Sources | ESI and APCI |
| Detection Modes | Full Scan, SIM, SIR |
| Software | MassLynx v4.2 or later |
| Dynamic Range | 10⁶–10⁷ |
| Compliance | Designed for GLP/GMP environments |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | SQD2 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Chromatography Compatibility | UPLC, HPLC, UPC², SFC, Prep-LC, Prep-SFC, ASAP Direct Analysis |
| Ionization Modes | ESI, APCI, UniSpray, ZSpray |
| Mass Range | 0–3000 m/z |
| Software Platform | MassLynx, OpenLynx Open Access, AutoPurification Integration |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SYNAPT XS |
| Instrument Type | Ion Mobility Mass Spectrometer |
| Application Scope | Universal |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Mass Range | m/z 10–2000 |
| Ionization Sources | ESI & APCI |
| Scan Modes | Full Scan, SIM, MRM |
| MRM Acquisition Rate | Up to 1000 transitions/sec |
| Dynamic Range | 10⁶–10⁷ |
| Detection Limit | Low pmol/L (ESI-MRM) |
| Software | MassLynx v4.2 or later |
| Compliance | Designed for GLP/GMP environments |
| Typical Service Life | 3–5 years (verified operational history, full service logs available upon request) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | TQD |
| Mass Range | m/z 10–2000 |
| Ionization Sources | ESI & APCI |
| Scan Modes | Full Scan, SIM, MRM |
| MRM Transition Rate | Up to 1000 transitions/sec |
| Dynamic Range | 10⁶–10⁷ |
| Detection Limit | Low pmol/L (ESI) |
| Software | MassLynx v4.2 or later |
| Compliance | ASTM D7598, USP <1225>, FDA 21 CFR Part 11 (with audit trail enabled) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | UNIFI |
| Pricing | Available Upon Request |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | UPLC + Xevo TQD |
| Price Range | USD $26,000 – $39,000 (FOB) |
| Operational Age | 3–5 years |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Xevo CDMS |
| Pricing | Available Upon Request |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Model | Xevo G3 QTof |
| Application Scope | Universal LC-MS/MS Platform |
| Mass Range | Not specified in source data |
| Resolution | Not specified in source data |
| Mass Accuracy | Not specified in source data |
| Sensitivity | Not specified in source data |
| Pressure Range | Not specified in source data |
| Compliance Context | Designed for GLP/GMP-aligned laboratories |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Xevo MRT |
| Instrument Type | Time-of-Flight (TOF) |
| Application Scope | General-Purpose |
| Resolution | 100,000 FWHM at 100 Hz |
| Mass Accuracy | <500 ppb |
| m/z Range | Broad, consistent across full scan range |
| Analyzer Architecture | Multi-Reflecting Time-of-Flight (MRT) with 4-meter effective flight path and 8 reflections |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Model | Xevo TQ Absolute |
| Instrument Type | Triple Quadrupole (TQ) |
| Application Scope | Universal LC-MS/MS Quantitation |
| Mass Range | Not specified by manufacturer in public datasheets |
| Sensitivity | Up to 15× higher for challenging negative-ion-mode analytes vs. prior-generation TQ systems |
| Resolution | Unit mass resolution standard for SRM/MRM transitions |
| Mass Accuracy | Not specified (typical for QqQ: ±0.1–0.2 Da under routine conditions) |
| Operating Pressure Range | Vacuum system maintained at <1×10⁻⁶ mbar in analyzer region |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Model | Xevo TQ Absolute XR |
| Instrument Type | Tandem Quadrupole (Triple Quadrupole) |
| Application Scope | Universal LC-MS/MS Analysis |
| Mass Range | Not Specified by Manufacturer |
| Sensitivity | Not Specified by Manufacturer |
| Resolution | Not Specified by Manufacturer |
| Mass Accuracy | Not Specified by Manufacturer |
| Operating Pressure Range | Not Specified by Manufacturer |