BrandBrookfield
OriginUSA
Manufacturer TypeManufacturer
Origin CategoryImported
Model651
Instrument TypeOnline Gas Monitor
Target GasHydrogen Sulfide (H₂S)
Response Time≤60 s
Measurement Accuracy±0.005 ppm
Measurement Range3 ppb (0.003 ppm) to 50 ppm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookfield
OriginUSA
Manufacturer TypeManufacturer
Origin CategoryImported
ModelJ405
Instrument TypePortable
Target GasElemental Mercury Vapor (Hg⁰)
Response Time2 seconds
Measurement Accuracy±0.01 µg/m³ (±0.00001 mg/m³)
Measurement Range0.5–999 µg/m³
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookfield
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelJ605
Instrument TypePortable Gas Analyzer
Target GasHydrogen Sulfide (H₂S)
Response Time12–27 s (Survey Mode)
Measurement Accuracy±1 ppb at 5 ppb, ±3 ppb at 50 ppb, ±0.03 ppm at 0.5 ppm, ±0.3 ppm at 5.0 ppm
Measurement Range3 ppb (0.003 ppm) to 10 ppm
Resolution20 ppt (0.02 ppb)
Gas Flow Rate150 mL/min
Data Storage Capacity20,000 samples with timestamp and up to 80 location tags
Battery Life18 h (rechargeable NiMH), 3 h charge time
Operating Temperature0–40 °C, non-condensing, non-explosive environment
CertificationsTÜV 61010, CE, ISO 9001:2015
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookfield
OriginUSA
Manufacturer TypeManufacturer
Origin CategoryImported
Model631-X
Instrument TypePortable
Target GasHydrogen Sulfide (H₂S)
Response Time3–20 seconds
Measurement Accuracy±0.003 ppm
Measurement Range0.003 ppm to 50 ppm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookfield
OriginUSA
Manufacturer TypeManufacturer
Origin CategoryImported
ModelJ505
Instrument TypePortable
Target GasElemental Mercury Vapor (Hg⁰)
Response Time8 s (Search Mode)
Measurement Accuracy±15% at 0.3 µg/m³
Measurement Range0.05 µg/m³ to 500 µg/m³
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookfield
OriginUSA
ManufacturerAMETEK Arizona
TypeOnline Fixed-Station Monitor
Target GasElemental Mercury Vapor (Hg⁰)
Response Time≤60 s
Measurement Accuracy±0.001 mg/m³
Measurement Range0.003–0.999 mg/m³
Sensor TechnologyGold Film Amalgamation
Environmental RatingIP65 Enclosure
Operating Temperature–20 °C to +50 °C
Data OutputModbus RTU/TCP, Ethernet, Optional 4G LTE
Alarm OutputsRelay + Email/SMS Notification
ComplianceOSHA PEL (0.1 mg/m³), NIOSH REL (0.05 mg/m³), ACGIH TLV (0.025 mg/m³), MSHA Standards