Empowering Scientific Discovery

Brookhaven Instruments Corporation

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookhaven
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelACOS
PricingUpon Request
Dispersion MethodDry & Wet Dispersion
Instrument TypeIn-Line Laser Particle Size Analyzer
Measurement RangeParticle Size: 0.6 nm – 3 µm
Dynamic Concentration Range0.1 ppm – 40% (w/v)
RepeatabilityConfigurable per application protocol
Measurement DurationUser-Defined
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookhaven
OriginUSA
ModelNanoBrook 90Plus
Dispersion MethodWet Dispersion
Measurement Range0.3 nm – 15 µm
Repeatability±1%
Measurement Time1–2 min
Temperature Control Range−5 °C to 110 °C (±0.1 °C)
Sample Volume10–3000 µL
Laser Source40 mW Solid-State Laser
DetectorPMT or APD
Correlator4×10¹¹ Linear Channels, 4-Channel Input, Dual Cross-Correlation Support
Scattering Angles15° and 90° Options
Zeta Potential OptionAvailable
Software Compliance21 CFR Part 11 Audit Trail Mode
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookhaven Instruments
OriginUSA
Model173Plus
Particle Size Range0.3 nm – 10 μm
Concentration Range0.1 ppm – 40% w/v
Typical Accuracy±1%
Sample Volume10–3000 μL (with 10 μL & 50 μL micro-cells)
Molecular Weight Range342 – 2×10⁷ Da
Temperature Control−5°C to 120°C (±0.1°C stability)
pH Range1–14
Laser Source40 mW solid-state laser (optional 5 mW He-Ne)
DetectorAvalanche Photodiode (APD)
Correlator4×10¹¹ linear channels, dual-channel cross-correlation support
Scattering Angles13°, 90°, and 173° (motorized, software-selectable)
Optional ModulesMicro-rheology, Zeta Potential, In-line Process Monitoring, Automated Titrator, Dielectric Constant Meter, Viscometer, 21 CFR Part 11 Compliant Software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookhaven
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelNanoBrook 90plus PALS
Dispersion MethodWet Dispersion
Particle Size Range0.3 nm – 15 µm
Repeatability±1%
Measurement Time1–2 min
Zeta Potential Measurement PrinciplePhase Analysis Light Scattering (PALS)
Temperature Control Range−5 °C to 110 °C (±0.1 °C)
Scattering Angles15° and 90°
Laser Source40 mW Solid-State Laser (He-Ne Optional)
DetectorAPD or PMT
Correlator4×10¹¹ linear channels, 4-channel input, dual cross-correlation support
Electrophoretic Mobility Range10⁻¹¹ – 10⁻⁷ m²/V·s
Conductivity Range0 – 30 S/m
pH Range1 – 14
Sample Volume10 µL – 3 mL (with 10 µL & 50 µL micro-cells)
Molecular Weight Range342 – 2×10⁷ Da
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelBI-DNDC
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookhaven Instruments
OriginUSA
ModelBioDLS
Dispersion MethodDry & Wet Dispersion
Instrument TypeOnline Laser Particle Size Analyzer
Particle Size Range0.5 nm – 3 µm (sample-dependent)
Molecular Weight Range4 × 10² – 2 × 10⁷ Da (sample-dependent)
Concentration Range0.1 – 100 mg/mL (sample-dependent)
Sample Volume2 µL
ThroughputUp to 768 samples per run (2 × 384-well plates)
Temperature ControlSample cell: 5–90 °C
Storage plateAmbient to 4 °C
Laser Source35 mW, 635 nm solid-state laser (optional 30 mW, 850 nm)
Scattering Angle90°
DetectorAvalanche Photodiode (APD)
Correlator522 physical channels, 10¹⁰ linear channels, dynamic sampling/delay range: 25 ns – 1310 s
InterfaceUSB 2.0 & 1.1
SoftwareWindows XP/Vista compatible
Dimensions (w/d/h)300 × 510 × 630 mm (28 kg, no storage cooler)
Operating Environment10–75 °C, 0–95% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookhaven Instruments
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelNanoDLS
Dispersion MethodWet & Dry Dispersion
Instrument TypeOnline Laser Particle Size Analyzer
Measurement Range0.5 nm – 3 µm (refractive index dependent)
Repeatability≤1% (typical)
Measurement Time<10 s per acquisition (configurable)
Sample Volume2.5 µL
Max Operating Pressure400 bar (5,880 psi)
Concentration Range0.1–100 mg/mL
Temperature Control Range25–80 °C
Laser Source35 mW, 638 nm solid-state laser
DetectorAvalanche Photodiode (APD)
Scattering Angle90°
InterfaceUSB 2.0 & 1.1
Data OutputHydrodynamic diameter distribution (intensity-, number-, and volume-weighted), Gaussian & multimodal fitting, real-time aggregation kinetics plots
Operation ModeAuto-sampling or manual injection
Optional IntegrationBI-MwA multi-angle static light scattering module for SEC-MALS coupling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookhaven
OriginUSA
ModelBI-MwA
Molecular Weight Range500–10⁹ Da
Hydrodynamic Size Range10–1000 nm
Scattering Volume20 nL
Sample Cell Volume100 µL
Maximum Back Pressure3.5 MPa (500 psi)
Detection Angles8 fixed angles (35°, 50°, 75°, 90°, 105°, 130°, 145° + reference angle)
DetectorHigh-Sensitivity CCD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookhaven
OriginUSA
ModelNanoBrook ZetaPALS
pH Range1–14
Temperature Range−5 to 110 °C
pH Resolution0.1
Temperature Resolution0.1 °C
Accuracy±1%
Repeatability±1%
Electrophoretic Mobility Range1×10⁻¹¹ to 1×10⁻⁷ m²/V·s
Particle Size Range (optional DLS)0.001–100 µm
Sample Volume0.018–1.5 mL
Conductivity Range0–30 S/m
Electric Field Strength0–3.2 kV/m
Laser Source40 mW solid-state laser (wavelength & power customizable)
DetectorPMT or APD
Electrode MaterialPalladium (corrosion-resistant open-cell capillary electrode optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookhaven Instruments
OriginUSA
ModelBI-200SM
Particle Size Range1 nm – 6 µm
Molecular Weight Range500 – 10⁹ Da
Hydrodynamic Size Range10 – 1000 nm
Scattering Angle Range8°–162°, ±0.01°
Temperature Control Range−20 °C to 80 °C (optional −20 °C to 150 °C), ±0.1 °C
Laser Wavelength Options632.8 nm, 532 nm, 514.5 nm, 488 nm
Aperture Wheel Sizes100 µm, 200 µm, 400 µm, 1 mm, 2 mm, 3 mm
CorrelatorTurboCorr digital photon correlator
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelBI-ZTU
PricingAvailable Upon Request
pH Range2–12
Sample Cell OptionFlow-Through Cell
Pump Tubing1 mm (0.04") ID, Compatible with Teflon®, PEEK®, and EPDM®
Included AccessoriesIntegrated pH Electrode + Four 100 mL Reagent Bottles
Drive SystemFour Independent Peristaltic Pumps
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookhaven
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelNanoBrook 90Plus Zeta
Dispersion MethodWet Dispersion
Instrument TypeLaboratory Laser Particle Size Analyzer
Size Range0.3 nm – 15 µm
Repeatability±1%
Measurement Time1–2 min
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookhaven
OriginUSA
ModelNanoBrook Omni
Dispersion MethodWet Dispersion
Particle Size Range0.3 nm – 15 µm
Repeatability<1%
Measurement Time1–2 min
Scattering Angles13°, 90°, 173°
Zeta Potential TechniqueHardware-Based Phase Analysis Light Scattering (PALS)
Concentration Range0.1 ppm – 40% w/v
Temperature Control−5 °C to 120 °C (±0.1 °C)
Sample Volume10 µL – 3 mL
Laser Source40 mW Solid-State Laser (optional 5 mW He-Ne)
DetectorAPD
Correlator4×10¹¹ linear channels, 4-channel input, dual cross-correlation support
Electrophoretic Mobility Range10⁻¹¹ – 10⁻⁷ m²/V·s
Conductivity Range0 – 30 S/m
pH Range1 – 14
Molecular Weight Range342 – 2×10⁷ Da
Optional Compliance21 CFR Part 11 Software Module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookhaven
OriginUSA
ModelNanoBrook ZetaPlus
Zeta Potential Range±500 mV
pH Range1–14
Temperature Range−5 to 110 °C
pH Resolution0.1
Temperature Resolution0.1 °C
Accuracy±1%
Repeatability±1%
Particle Size Range (Electrophoretic Mode)0.001–100 µm
Sample Volume0.18–1.5 mL
Conductivity Range0–20 S/m
Electrophoretic Mobility Range1×10⁻¹⁰ to 1×10⁻⁷ m²/V·s
Electric Field Strength0–3.2 kV/m
Electrode MaterialPalladium (corrosion-resistant, open-cell design)
Laser Source35 mW solid-state laser (optional 5 mW He–Ne)
DetectorPMT or APD
Automated Trend Analysistime-, temperature-, pH-, and conductivity-dependent
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookhaven Instruments
OriginUSA
ModelBI-870
Measurement Range1–20 and 1–200
Accuracy±2%
Repeatability & Linearity±0.2%
Max Sample Conductivity1 µS/cm (for range 1–20), 10 µS/cm (for range 1–200)
Minimum Sample Volume25 mL
Probe MaterialStainless Steel & PTFE
Excitation SignalLow-distortion 10 kHz sine wave (7 Vrms for 1–20 range
DisplayLCD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookhaven Instruments
OriginUSA
ModelBI-DCP / BI-XDC
Measurement PrincipleCentrifugal & Gravitational Sedimentation
Repeatability1%
Accuracy±2%
Particle Size Range (BI-DCP)0.01–45 µm
Particle Size Range (BI-XDC)0.01–100 µm
Detection MethodVisible Light (BI-DCP) / X-ray (BI-XDC)
Sample IntroductionLayered (LIST mode) or Homogeneous (HOST mode)
Rotational Speed Range500–15,000 rpm (BI-DCP)
Speed Stability±0.01%
Disk MaterialStandard PMMA or Corrosion-Resistant Alternative
Data StorageBuilt-in extinction curve database (BI-DCP)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookhaven
OriginUSA
ModelNanoBrook 173Plus
Dispersion MethodWet Dispersion
Instrument TypeLaboratory Laser-Based Particle Size Analyzer
Measurement Range0.3 nm – 10 µm
Repeatability±1%
Measurement Time1–2 min
Scattering Angles15°, 90°, 173°
Concentration Range0.1 ppm – 40% w/v
Temperature Control−5 °C to 120 °C (±0.1 °C)
Laser Source40 mW Solid-State Laser (optional 5 mW He-Ne)
DetectorAPD
Correlator4×10¹¹ Linear Channels, Dual-Channel Cross-Correlation Support
Sample Volume0.01–3 mL (with optional 50 µL and 10 µL micro-cells)
Molecular Weight Range342–2×10⁷ Da
pH Range1–14
Software Compliance21 CFR Part 11 Ready
Added to wishlistRemoved from wishlist 0
Add to compare
OriginNetherlands
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelEyeTech
Price RangeUSD 110,000–138,000
Dispersion MethodDry & Wet
Measurement Range0.01–3600 µm
Repeatability<1% RSD
Measurement Time10–60 s
Concentration Range~10⁹ particles/mL
Light SourceStabilized He–Ne Laser (632.8 nm)
Laser Resolution0.33% of full scale
DetectorSilicon PIN Photodiode
Stroboscopic IlluminationAdjustable intensity & pulse duration
CameraHigh-resolution monochrome CCD
Shape Parameters40 ISO-compliant morphological descriptors
Sample IntroductionLiquid suspension, dry powder, microscope slide-mounted
Software ComplianceFDA 21 CFR Part 11 (audit trail, user roles, electronic signatures)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0