- All
- Favorite
- Popular
- Most rated
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACOS |
| Pricing | Upon Request |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | In-Line Laser Particle Size Analyzer |
| Measurement Range | Particle Size: 0.6 nm – 3 µm |
| Dynamic Concentration Range | 0.1 ppm – 40% (w/v) |
| Repeatability | Configurable per application protocol |
| Measurement Duration | User-Defined |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook 90Plus |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.3 nm – 15 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Temperature Control Range | −5 °C to 110 °C (±0.1 °C) |
| Sample Volume | 10–3000 µL |
| Laser Source | 40 mW Solid-State Laser |
| Detector | PMT or APD |
| Correlator | 4×10¹¹ Linear Channels, 4-Channel Input, Dual Cross-Correlation Support |
| Scattering Angles | 15° and 90° Options |
| Zeta Potential Option | Available |
| Software Compliance | 21 CFR Part 11 Audit Trail Mode |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NanoBrook 90plus PALS |
| Dispersion Method | Wet Dispersion |
| Particle Size Range | 0.3 nm – 15 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Zeta Potential Measurement Principle | Phase Analysis Light Scattering (PALS) |
| Temperature Control Range | −5 °C to 110 °C (±0.1 °C) |
| Scattering Angles | 15° and 90° |
| Laser Source | 40 mW Solid-State Laser (He-Ne Optional) |
| Detector | APD or PMT |
| Correlator | 4×10¹¹ linear channels, 4-channel input, dual cross-correlation support |
| Electrophoretic Mobility Range | 10⁻¹¹ – 10⁻⁷ m²/V·s |
| Conductivity Range | 0 – 30 S/m |
| pH Range | 1 – 14 |
| Sample Volume | 10 µL – 3 mL (with 10 µL & 50 µL micro-cells) |
| Molecular Weight Range | 342 – 2×10⁷ Da |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Model | BioDLS |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Particle Size Range | 0.5 nm – 3 µm (sample-dependent) |
| Molecular Weight Range | 4 × 10² – 2 × 10⁷ Da (sample-dependent) |
| Concentration Range | 0.1 – 100 mg/mL (sample-dependent) |
| Sample Volume | 2 µL |
| Throughput | Up to 768 samples per run (2 × 384-well plates) |
| Temperature Control | Sample cell: 5–90 °C |
| Storage plate | Ambient to 4 °C |
| Laser Source | 35 mW, 635 nm solid-state laser (optional 30 mW, 850 nm) |
| Scattering Angle | 90° |
| Detector | Avalanche Photodiode (APD) |
| Correlator | 522 physical channels, 10¹⁰ linear channels, dynamic sampling/delay range: 25 ns – 1310 s |
| Interface | USB 2.0 & 1.1 |
| Software | Windows XP/Vista compatible |
| Dimensions (w/d/h) | 300 × 510 × 630 mm (28 kg, no storage cooler) |
| Operating Environment | 10–75 °C, 0–95% RH (non-condensing) |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NanoDLS |
| Dispersion Method | Wet & Dry Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Measurement Range | 0.5 nm – 3 µm (refractive index dependent) |
| Repeatability | ≤1% (typical) |
| Measurement Time | <10 s per acquisition (configurable) |
| Sample Volume | 2.5 µL |
| Max Operating Pressure | 400 bar (5,880 psi) |
| Concentration Range | 0.1–100 mg/mL |
| Temperature Control Range | 25–80 °C |
| Laser Source | 35 mW, 638 nm solid-state laser |
| Detector | Avalanche Photodiode (APD) |
| Scattering Angle | 90° |
| Interface | USB 2.0 & 1.1 |
| Data Output | Hydrodynamic diameter distribution (intensity-, number-, and volume-weighted), Gaussian & multimodal fitting, real-time aggregation kinetics plots |
| Operation Mode | Auto-sampling or manual injection |
| Optional Integration | BI-MwA multi-angle static light scattering module for SEC-MALS coupling |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NanoBrook 90Plus Zeta |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Size Range | 0.3 nm – 15 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FOQELS |
| Pricing | Upon Request |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook Omni |
| Dispersion Method | Wet Dispersion |
| Particle Size Range | 0.3 nm – 15 µm |
| Repeatability | <1% |
| Measurement Time | 1–2 min |
| Scattering Angles | 13°, 90°, 173° |
| Zeta Potential Technique | Hardware-Based Phase Analysis Light Scattering (PALS) |
| Concentration Range | 0.1 ppm – 40% w/v |
| Temperature Control | −5 °C to 120 °C (±0.1 °C) |
| Sample Volume | 10 µL – 3 mL |
| Laser Source | 40 mW Solid-State Laser (optional 5 mW He-Ne) |
| Detector | APD |
| Correlator | 4×10¹¹ linear channels, 4-channel input, dual cross-correlation support |
| Electrophoretic Mobility Range | 10⁻¹¹ – 10⁻⁷ m²/V·s |
| Conductivity Range | 0 – 30 S/m |
| pH Range | 1 – 14 |
| Molecular Weight Range | 342 – 2×10⁷ Da |
| Optional Compliance | 21 CFR Part 11 Software Module |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook 173Plus |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Size Analyzer |
| Measurement Range | 0.3 nm – 10 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Scattering Angles | 15°, 90°, 173° |
| Concentration Range | 0.1 ppm – 40% w/v |
| Temperature Control | −5 °C to 120 °C (±0.1 °C) |
| Laser Source | 40 mW Solid-State Laser (optional 5 mW He-Ne) |
| Detector | APD |
| Correlator | 4×10¹¹ Linear Channels, Dual-Channel Cross-Correlation Support |
| Sample Volume | 0.01–3 mL (with optional 50 µL and 10 µL micro-cells) |
| Molecular Weight Range | 342–2×10⁷ Da |
| pH Range | 1–14 |
| Software Compliance | 21 CFR Part 11 Ready |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EyeTech |
| Price Range | USD 110,000–138,000 |
| Dispersion Method | Dry & Wet |
| Measurement Range | 0.01–3600 µm |
| Repeatability | <1% RSD |
| Measurement Time | 10–60 s |
| Concentration Range | ~10⁹ particles/mL |
| Light Source | Stabilized He–Ne Laser (632.8 nm) |
| Laser Resolution | 0.33% of full scale |
| Detector | Silicon PIN Photodiode |
| Stroboscopic Illumination | Adjustable intensity & pulse duration |
| Camera | High-resolution monochrome CCD |
| Shape Parameters | 40 ISO-compliant morphological descriptors |
| Sample Introduction | Liquid suspension, dry powder, microscope slide-mounted |
| Software Compliance | FDA 21 CFR Part 11 (audit trail, user roles, electronic signatures) |