- All
- Favorite
- Popular
- Most rated
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACOS |
| Pricing | Upon Request |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | In-Line Laser Particle Size Analyzer |
| Measurement Range | Particle Size: 0.6 nm – 3 µm |
| Dynamic Concentration Range | 0.1 ppm – 40% (w/v) |
| Repeatability | Configurable per application protocol |
| Measurement Duration | User-Defined |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook 90Plus |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.3 nm – 15 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Temperature Control Range | −5 °C to 110 °C (±0.1 °C) |
| Sample Volume | 10–3000 µL |
| Laser Source | 40 mW Solid-State Laser |
| Detector | PMT or APD |
| Correlator | 4×10¹¹ Linear Channels, 4-Channel Input, Dual Cross-Correlation Support |
| Scattering Angles | 15° and 90° Options |
| Zeta Potential Option | Available |
| Software Compliance | 21 CFR Part 11 Audit Trail Mode |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Model | 173Plus |
| Particle Size Range | 0.3 nm – 10 μm |
| Concentration Range | 0.1 ppm – 40% w/v |
| Typical Accuracy | ±1% |
| Sample Volume | 10–3000 μL (with 10 μL & 50 μL micro-cells) |
| Molecular Weight Range | 342 – 2×10⁷ Da |
| Temperature Control | −5°C to 120°C (±0.1°C stability) |
| pH Range | 1–14 |
| Laser Source | 40 mW solid-state laser (optional 5 mW He-Ne) |
| Detector | Avalanche Photodiode (APD) |
| Correlator | 4×10¹¹ linear channels, dual-channel cross-correlation support |
| Scattering Angles | 13°, 90°, and 173° (motorized, software-selectable) |
| Optional Modules | Micro-rheology, Zeta Potential, In-line Process Monitoring, Automated Titrator, Dielectric Constant Meter, Viscometer, 21 CFR Part 11 Compliant Software |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NanoBrook 90plus PALS |
| Dispersion Method | Wet Dispersion |
| Particle Size Range | 0.3 nm – 15 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Zeta Potential Measurement Principle | Phase Analysis Light Scattering (PALS) |
| Temperature Control Range | −5 °C to 110 °C (±0.1 °C) |
| Scattering Angles | 15° and 90° |
| Laser Source | 40 mW Solid-State Laser (He-Ne Optional) |
| Detector | APD or PMT |
| Correlator | 4×10¹¹ linear channels, 4-channel input, dual cross-correlation support |
| Electrophoretic Mobility Range | 10⁻¹¹ – 10⁻⁷ m²/V·s |
| Conductivity Range | 0 – 30 S/m |
| pH Range | 1 – 14 |
| Sample Volume | 10 µL – 3 mL (with 10 µL & 50 µL micro-cells) |
| Molecular Weight Range | 342 – 2×10⁷ Da |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BI-DNDC |
| Pricing | Available Upon Request |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Model | BioDLS |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Particle Size Range | 0.5 nm – 3 µm (sample-dependent) |
| Molecular Weight Range | 4 × 10² – 2 × 10⁷ Da (sample-dependent) |
| Concentration Range | 0.1 – 100 mg/mL (sample-dependent) |
| Sample Volume | 2 µL |
| Throughput | Up to 768 samples per run (2 × 384-well plates) |
| Temperature Control | Sample cell: 5–90 °C |
| Storage plate | Ambient to 4 °C |
| Laser Source | 35 mW, 635 nm solid-state laser (optional 30 mW, 850 nm) |
| Scattering Angle | 90° |
| Detector | Avalanche Photodiode (APD) |
| Correlator | 522 physical channels, 10¹⁰ linear channels, dynamic sampling/delay range: 25 ns – 1310 s |
| Interface | USB 2.0 & 1.1 |
| Software | Windows XP/Vista compatible |
| Dimensions (w/d/h) | 300 × 510 × 630 mm (28 kg, no storage cooler) |
| Operating Environment | 10–75 °C, 0–95% RH (non-condensing) |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NanoDLS |
| Dispersion Method | Wet & Dry Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Measurement Range | 0.5 nm – 3 µm (refractive index dependent) |
| Repeatability | ≤1% (typical) |
| Measurement Time | <10 s per acquisition (configurable) |
| Sample Volume | 2.5 µL |
| Max Operating Pressure | 400 bar (5,880 psi) |
| Concentration Range | 0.1–100 mg/mL |
| Temperature Control Range | 25–80 °C |
| Laser Source | 35 mW, 638 nm solid-state laser |
| Detector | Avalanche Photodiode (APD) |
| Scattering Angle | 90° |
| Interface | USB 2.0 & 1.1 |
| Data Output | Hydrodynamic diameter distribution (intensity-, number-, and volume-weighted), Gaussian & multimodal fitting, real-time aggregation kinetics plots |
| Operation Mode | Auto-sampling or manual injection |
| Optional Integration | BI-MwA multi-angle static light scattering module for SEC-MALS coupling |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | BI-MwA |
| Molecular Weight Range | 500–10⁹ Da |
| Hydrodynamic Size Range | 10–1000 nm |
| Scattering Volume | 20 nL |
| Sample Cell Volume | 100 µL |
| Maximum Back Pressure | 3.5 MPa (500 psi) |
| Detection Angles | 8 fixed angles (35°, 50°, 75°, 90°, 105°, 130°, 145° + reference angle) |
| Detector | High-Sensitivity CCD |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook ZetaPALS |
| pH Range | 1–14 |
| Temperature Range | −5 to 110 °C |
| pH Resolution | 0.1 |
| Temperature Resolution | 0.1 °C |
| Accuracy | ±1% |
| Repeatability | ±1% |
| Electrophoretic Mobility Range | 1×10⁻¹¹ to 1×10⁻⁷ m²/V·s |
| Particle Size Range (optional DLS) | 0.001–100 µm |
| Sample Volume | 0.018–1.5 mL |
| Conductivity Range | 0–30 S/m |
| Electric Field Strength | 0–3.2 kV/m |
| Laser Source | 40 mW solid-state laser (wavelength & power customizable) |
| Detector | PMT or APD |
| Electrode Material | Palladium (corrosion-resistant open-cell capillary electrode optional) |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Model | BI-200SM |
| Particle Size Range | 1 nm – 6 µm |
| Molecular Weight Range | 500 – 10⁹ Da |
| Hydrodynamic Size Range | 10 – 1000 nm |
| Scattering Angle Range | 8°–162°, ±0.01° |
| Temperature Control Range | −20 °C to 80 °C (optional −20 °C to 150 °C), ±0.1 °C |
| Laser Wavelength Options | 632.8 nm, 532 nm, 514.5 nm, 488 nm |
| Aperture Wheel Sizes | 100 µm, 200 µm, 400 µm, 1 mm, 2 mm, 3 mm |
| Correlator | TurboCorr digital photon correlator |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BI-ZTU |
| Pricing | Available Upon Request |
| pH Range | 2–12 |
| Sample Cell Option | Flow-Through Cell |
| Pump Tubing | 1 mm (0.04") ID, Compatible with Teflon®, PEEK®, and EPDM® |
| Included Accessories | Integrated pH Electrode + Four 100 mL Reagent Bottles |
| Drive System | Four Independent Peristaltic Pumps |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NanoBrook 90Plus Zeta |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Size Range | 0.3 nm – 15 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FOQELS |
| Pricing | Upon Request |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook Omni |
| Dispersion Method | Wet Dispersion |
| Particle Size Range | 0.3 nm – 15 µm |
| Repeatability | <1% |
| Measurement Time | 1–2 min |
| Scattering Angles | 13°, 90°, 173° |
| Zeta Potential Technique | Hardware-Based Phase Analysis Light Scattering (PALS) |
| Concentration Range | 0.1 ppm – 40% w/v |
| Temperature Control | −5 °C to 120 °C (±0.1 °C) |
| Sample Volume | 10 µL – 3 mL |
| Laser Source | 40 mW Solid-State Laser (optional 5 mW He-Ne) |
| Detector | APD |
| Correlator | 4×10¹¹ linear channels, 4-channel input, dual cross-correlation support |
| Electrophoretic Mobility Range | 10⁻¹¹ – 10⁻⁷ m²/V·s |
| Conductivity Range | 0 – 30 S/m |
| pH Range | 1 – 14 |
| Molecular Weight Range | 342 – 2×10⁷ Da |
| Optional Compliance | 21 CFR Part 11 Software Module |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook ZetaPlus |
| Zeta Potential Range | ±500 mV |
| pH Range | 1–14 |
| Temperature Range | −5 to 110 °C |
| pH Resolution | 0.1 |
| Temperature Resolution | 0.1 °C |
| Accuracy | ±1% |
| Repeatability | ±1% |
| Particle Size Range (Electrophoretic Mode) | 0.001–100 µm |
| Sample Volume | 0.18–1.5 mL |
| Conductivity Range | 0–20 S/m |
| Electrophoretic Mobility Range | 1×10⁻¹⁰ to 1×10⁻⁷ m²/V·s |
| Electric Field Strength | 0–3.2 kV/m |
| Electrode Material | Palladium (corrosion-resistant, open-cell design) |
| Laser Source | 35 mW solid-state laser (optional 5 mW He–Ne) |
| Detector | PMT or APD |
| Automated Trend Analysis | time-, temperature-, pH-, and conductivity-dependent |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Model | BI-DCP / BI-XDC |
| Measurement Principle | Centrifugal & Gravitational Sedimentation |
| Repeatability | 1% |
| Accuracy | ±2% |
| Particle Size Range (BI-DCP) | 0.01–45 µm |
| Particle Size Range (BI-XDC) | 0.01–100 µm |
| Detection Method | Visible Light (BI-DCP) / X-ray (BI-XDC) |
| Sample Introduction | Layered (LIST mode) or Homogeneous (HOST mode) |
| Rotational Speed Range | 500–15,000 rpm (BI-DCP) |
| Speed Stability | ±0.01% |
| Disk Material | Standard PMMA or Corrosion-Resistant Alternative |
| Data Storage | Built-in extinction curve database (BI-DCP) |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook 173Plus |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Size Analyzer |
| Measurement Range | 0.3 nm – 10 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Scattering Angles | 15°, 90°, 173° |
| Concentration Range | 0.1 ppm – 40% w/v |
| Temperature Control | −5 °C to 120 °C (±0.1 °C) |
| Laser Source | 40 mW Solid-State Laser (optional 5 mW He-Ne) |
| Detector | APD |
| Correlator | 4×10¹¹ Linear Channels, Dual-Channel Cross-Correlation Support |
| Sample Volume | 0.01–3 mL (with optional 50 µL and 10 µL micro-cells) |
| Molecular Weight Range | 342–2×10⁷ Da |
| pH Range | 1–14 |
| Software Compliance | 21 CFR Part 11 Ready |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EyeTech |
| Price Range | USD 110,000–138,000 |
| Dispersion Method | Dry & Wet |
| Measurement Range | 0.01–3600 µm |
| Repeatability | <1% RSD |
| Measurement Time | 10–60 s |
| Concentration Range | ~10⁹ particles/mL |
| Light Source | Stabilized He–Ne Laser (632.8 nm) |
| Laser Resolution | 0.33% of full scale |
| Detector | Silicon PIN Photodiode |
| Stroboscopic Illumination | Adjustable intensity & pulse duration |
| Camera | High-resolution monochrome CCD |
| Shape Parameters | 40 ISO-compliant morphological descriptors |
| Sample Introduction | Liquid suspension, dry powder, microscope slide-mounted |
| Software Compliance | FDA 21 CFR Part 11 (audit trail, user roles, electronic signatures) |
Show next