Empowering Scientific Discovery

Bruker Daltonics Inc.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Modelcompact
Instrument TypeQuadrupole-Time-of-Flight (QTOF)
Application ScopeUniversal LC-MS/MS Platform
Key Specifications50 GBit/sec acquisition rate
ResolutionUltra-High Resolution TOF (UHR-TOF)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModeltimsTOF Pro 2
Instrument TypeTrapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer
Application DomainSpecialized Omics Research (Proteomics, Lipidomics, Phosphoproteomics, Clinical Biomarker Discovery)
Regulatory ContextCompliant with GLP/GMP data integrity requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Instrument TypeTime-of-Flight (TOF)
ConfigurationDual-Source GC-MS (EI + CI)
Ionization ModesElectron Ionization (EI) and Chemical Ionization (CI) with Helical Resonant Plasma (HRP) source
Resolution>40,000 FWHM (m/z 200)
Mass Accuracy<1 ppm RMS (calibrated)
Scan RateUp to 50 spectra/sec (full-spectrum, high-res)
CI Reagent GasesN₂H⁺, H₃O⁺, H(H₂O)ₙ⁺, NH₄⁺ (software-switchable, no hardware intervention)
ComplianceFully compatible with GLP/GMP workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Instrument TypeTandem Quadrupole (Triple Quad)
ModelEVOQ® DART-TQ+
Application ScopeGeneral-purpose small-molecule screening and quantitation
Ionization ModesFully integrated DART (Direct Analysis in Real Time), swappable with VIP-HESI (Heated Electrospray Ionization) and APCI sources
MRM Transition RateUp to 1,000 transitions/sec
Scan SpeedUp to 30,000 Da/sec
DetectorEDR™ Electron Multiplier with real-time gain optimization
Software PlatformtqControl™ with MRM Builder, automated tuning, daily performance verification, and rule-based data review
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Instrument TypeTrapped Ion Mobility Spectrometry–Time-of-Flight Mass Spectrometer (TIMS-TOF)
ModeltimsTOF SCP
Application DomainSpecialized Single-Cell Proteomics, Immunopeptidomics, PTM Analysis, Epigenoproteomics
Ion SourceOptimized Dual-Orthogonal Reflectron Ion Source with 1-mm Transfer Capillary
Vacuum Architecture8-stage Differential Vacuum System
Acquisition Modedia-PASEF® (Data-Independent Acquisition Parallel Accumulation–Serial Fragmentation)
CCS CapabilityYes, Collision Cross Section–enabled Ion Mobility Separation
Scan Speed>120 Hz MS/MS
Software PlatformtimsControl, PaSER (Real-time Parallel Database Search Engine), Compatible with MaxQuant/Perseus, PEAKS Studio
Data FormatOpen .d Format (Bruker)
Regulatory ComplianceSupports 21 CFR Part 11–compliant workflows (audit trail, electronic signatures, data integrity controls)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModeltimsTOF HT
Instrument TypeTrapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer
TechnologyParallel Accumulation–Serial Fragmentation (PASEF®), CCS-enabled 4D-Proteomics
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Instrument TypeTandem Quadrupole (Triple Quad)
ConfigurationLC-MS/MS
Application ScopeUniversal Quantitative Analysis
Regulatory ComplianceDesigned for GLP/GMP environments, compatible with 21 CFR Part 11 audit trail requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Instrument TypeQuadrupole-TOF
Application ScopeUniversal LC-MS/MS
Optional FeaturesETD, HighMass Mode
Resolution (FSR)>80,000 at full sensitivity
Mass Accuracy<1 ppm RMS (calibrated, typical)
Mass RangeUp to 20,000 m/z (HighMass mode)
Isotopic Pattern FidelityTrue Isotopic Pattern (TIP) enabled
Software PlatformCompass DataAnalysis, Compass AutoPrep, SmartFormula™, SmartFormula 3D™
Regulatory ComplianceFDA 21 CFR Part 11 compliant workflows available
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Instrument TypeFTMS (Fourier Transform Mass Spectrometry)
ModelscimaX™
ResolutionR > 20,000,000 (at m/z 400)
Cooling SystemHelium-gas-cooled Maxwell™ superconducting magnet (cryogen-free)
Ion SourcesDual ESI/MALDI with automated switching
Fragmentation ModesECD, EID, ETD, CID, EDD, SORI-CID, MALDI-ISD, NETD
Acquisition ModeCASI (Collision-Activated Selective Ion accumulation)
Application ScopeUniversal — petroleumomics, phenomics, metabolomics, native proteomics, label-free MSI, fragment-based drug discovery
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModelsolariX
Instrument TypeFTMS (Fourier Transform Mass Spectrometer)
Magnetic Field Strength Options7T, 12T, 15T
Ionization ModesESI and MALDI (dual-source configurable)
Detection TechnologyParaCell detector with AMP (Absorption Mode Processing)
Software PlatformBruker Compass suite including SmartFormula
Compliance FrameworkDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: Bruker
OriginGermany
ModelPepSep™ C18
TypeReversed-phase analytical column for nano/micro-flow LC-MS
Packing MaterialSurface-modified silica with endcapping
Particle Size1.6 µm (typical for PepSep™ series)
Pore Size100 Å
Column ID75 µm × 25–50 cm (standard configurations)
Pressure Rating≤1000 bar
Compatible WithNanoLC, microLC, and timsTOF platforms (e.g., timsTOF Pro, timsTOF SCP)
Surface ChemistryC18 bonded phase with low silanol activity
Batch-to-batch reproducibility≤3% RSD in retention time (n=5 injections, standard peptide mix)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Instrument TypeIon Mobility Mass Spectrometer
ModeltimsTOF fleX with MALDI-2
Application ScopeUniversal (Biological Tissue Imaging, Lipidomics, Metabolomics, Drug Distribution Studies)
Regulatory ComplianceDesigned for GLP/GMP-aligned workflows
Software PlatformSCiLS Lab, DataAnalysis, and TIMS Control integrated in Compass 6.0 suite
Ionization ModesMALDI and MALDI-2 (laser post-ionization), ESI (via LC coupling)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Instrument TypeTrapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer
ModeltimsMetabo™
Application ScopeUniversal (Metabolomics, Lipidomics, Untargeted Small-Molecule Analysis)
Regulatory ComplianceDesigned for GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Instrument TypeTrapped Ion Mobility Spectrometry (TIMS)–based Mass Spectrometer
ModeltimsOmni
Application ScopeUniversal for native and denatured proteoforms, intact proteins, oligonucleotides, PTMs, small molecules, and multi-specific biologics
Regulatory ComplianceDesigned for GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModeltimsUltra AIP
Instrument TypeTrapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer
Application ScopeSpecialized Proteomics & Multi-Omics Platforms
Software IntegrationTIMS PASEF®, TIMScore™, DIA-NN 4D-Proteomics™, Spectronaut® 20, ICC 2.0
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelIon Source
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Modelautoflex maX
Instrument TypeTOF-TOF
Application ScopeUniversal
Laser Repetition Rateup to 2 kHz
Mass Resolutionup to 26,000 (m/z 1,000–5,000)
Mass Accuracysub-ppm (calibrated)
Detection Sensitivitylow amol (for peptides)
Ion SourcePerpetual™ laser-cleanable MALDI source
DetectorFlashDetector™ with 10-bit digitizer
Software SuiteCompass (flexControl, flexAnalysis, BioTools, GlycoWorkbench, Polymerix)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Instrument TypeTime-of-Flight (TOF)
ConfigurationBenchtop MALDI-TOF
Operating ModesLinear & Reflectron
ResolutionUp to 15,000 (m/z 1,000–2,000, reflectron mode)
LaserNitrogen laser, 337 nm, adjustable repetition rate up to 60 Hz
Ion SourcemicroScout™ pulsed ion extraction source
DetectorMicrochannel plate (MCP)
Vacuum SystemOil-free, maintenance-free turbomolecular pump with WhisperMode™ acoustic dampening
Sample TargetAnchorChip™ patterned stainless steel target
Software PlatformCompass Suite (including ProteinScape™, BioTools™, Polymerix™)
Regulatory Compliance OptionCompass Security Pack (21 CFR Part 11 compliant audit trail, electronic signatures, user access control)
Sample ThroughputHigh-speed automated acquisition enabled by precise AnchorChip™ spot positioning and integrated autoPSD (automated post-source decay) capability
Ionization ModePositive/Negative selectable
Mass RangeBroad dynamic range suitable for small molecules (e.g., lipids, additives), peptides, oligonucleotides, and synthetic polymers
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModelultrafleXtreme
Instrument TypeTOF-TOF
Application DomainUniversal
CategoryBiomass Spectrometer
Distribution StatusAuthorized Distributor (Imported)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Manufacturer TypeAuthorized Distributor
Product CategoryImported Instrument
ModeltimsTOF fleX™
Instrument TypeTrapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer
Application ScopeUniversal Platform for Spatial Omics and Molecular Imaging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Instrument TypeTrapped Ion Mobility Spectrometry–Time-of-Flight Mass Spectrometer (TIMS-TOF MS)
Ionization ModesDual MALDI/ESI
Application FocusLabel-free Ultra-High-Throughput Screening (uHTS) in Drug Discovery
Software PlatformMALDI PharmaPulse® 2023
Compliance ReadyGLP/GMP-aligned data handling, 21 CFR Part 11–compatible audit trail (via optional software configuration)
ThroughputUp to 3 samples/sec on 1536-well plates
CCS CalibrationYes, with internal standards
MALDI Source10 kHz smartbeam™ 3D laser, MALDI-2 option available
Sample HandlingRobotic MALDI target auto-loader, disposable targets (96–1536-well compatible)
Data ExportNative support for Genedata Screener®, Assay Explorer, and other HTS informatics platforms
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModelSPR #64
Instrument TypeSurface Plasmon Resonance (SPR)
Channel Configuration8-Channel Orthogonal Flow Cell with 64 Sensor Spots
Fluidic FlexibilityUp to 8 Simultaneous Buffer Streams
Automation InterfaceRESTful API & Robotic Integration Ready
Sample Format Support96-well & 384-well Microplates, Reagent Reservoirs, External Cooling-Compatible Stage
Cleaning MechanismIntegrated Dual-Prism Cartridge with Auto-Clean Protocol
Data Output FormatOpen HDF5, CSV, and JSON
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Instrument TypeTOF-TOF
Application DomainUniversal
ModelneofleX™
CategoryBiomass Spectrometer
Import StatusImported
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
ModelEVOQ GC-TQ
Instrument TypeTriple Quadrupole Mass Spectrometer
Chromatography ConfigurationConventional Gas Chromatography–Mass Spectrometry (GC-MS/MS)
Ionization ModesElectron Ionization (EI) and Negative Chemical Ionization (NCI)
Vacuum SystemHigh-Capacity Turbo-Molecular Pump
DetectorExtended Dynamic Range (EDR) Detector Integrated with Quadrupole Assembly
Ion OpticsLens-Free Ion Path
q0 Collision CellHelium-Gas-Assisted Active Ion Focusing
Ion Transmission ArchitectureElliptical Ion Channel
Method SetupAutomated MRM Transition Library Lookup by Compound Name
Compliance ReadinessDesigned for GLP/GMP environments
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0