Cell Analysis
Filter
Showing 61–90 of 175 results
| Brand | Axion BioSystems |
|---|---|
| Origin | USA |
| Manufacturer | Axion BioSystems, Inc. |
| Type | Imported Instrument |
| Model | Omni Pro 12 |
| Temperature Control Range | 5–40 °C |
| Humidity Control Range | 20–95% RH |
| Full-Plate Scan Time | ≤10 min per 384-well plate |
| Brand | Axion BioSystems |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Axion Exact FL |
| Pricing | Available Upon Request |
| Brand | Axion BioSystems |
|---|---|
| Origin | Netherlands |
| Manufacturer | Axion BioSystems |
| Product Type | Imported Instrument |
| Model | Omni |
| Temperature Control Range | 5–40 °C |
| Humidity Control Range | 20–95% RH |
| Imaging Speed | Full-plate brightfield/fluorescence scan in ≤10 minutes |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic |
| Model | CytoFLEX Flow Cytometer |
| Technical Approach | Analytical Flow Cytometry |
| Product Type | Flow Cytometry Analyzer |
| Application | Research Use Only (RUO) |
| Laser Configuration | Up to 3 Lasers (405 nm, 488 nm, 638 nm) |
| Detection Channels | 13–15 parameters (configurable) |
| Optical Resolution | Full-channel rCV < 3% |
| Sample Flow Rate | Fixed at 10, 30, or 60 µL/min |
| user-definable range | 10–240 µL/min |
| Fluorescence Sensitivity | FITC < 30 MESF |
| Event Acquisition Rate | 30,000 events/sec |
| Automated Sample Loading | Yes |
| Compensation | Fully automated digital compensation |
| Voltage Adjustment | Not required (fixed-optics architecture) |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | CytoFLEX LX |
| Technology Pathway | Analytical Flow Cytometry |
| Product Type | Flow Cytometry Analyzer |
| Primary Use Case | Research |
| Lasers | All channels support A (Area), H (Height), fixed W (Width), Time parameter, and absolute event count |
| Detection Channels | Full-channel rCV < 3% |
| Flow Rate | 10–240 µL/min |
| Fluorescence Sensitivity | ≤30,000 events per second (EPS) at 15-parameter acquisition |
| Cell Analysis Throughput | FITC < 30 MESF |
| Automated Sample Loading System | Yes |
| Acquisition Speed | Up to 30,000 events/second |
| Compensation Method | Fully automated, real-time digital compensation |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CytoFLEX mosaic |
| Technology Pathway | Analytical Flow Cytometry |
| Product Type | Spectral Flow Cytometer |
| Application Domain | Research |
| Lasers | 4–6 |
| Detection Channels | 63–88 |
| Optical Resolution | 80 nm |
| Fluorescence Sensitivity | FITC < 30 MESF, PE < 10 MESF |
| Acquisition Rate | 30,000 events/sec |
| Automated Sample Loading | Yes |
| Sample Flow Rate | 10–240 µL/min |
| Compensation Method | Real-time Automatic Compensation & On-the-fly Spectral Unmixing |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC-manufactured) |
| Model | CytoFLEX o |
| Technology Platform | Nanoscale Flow Cytometry |
| Product Category | Flow Cytometer |
| Primary Use Case | Research |
| Lasers | 405 nm, 488 nm, 561 nm, 638 nm |
| Fluorescence Detection Channels | 6 |
| Coefficient of Variation (rCV) | <10% |
| Fluorescence Sensitivity (8-peak calibration beads) | V447: 8 peaks |
| 8531 | 8 peaks |
| Y595 | 8 peaks |
| R670 | 6 peaks |
| R710 | 5 peaks |
| R792 | 4 peaks |
| Sample Acquisition Rate | 16,000 events/sec |
| Automated Sample Loading | Yes |
| Sample Flow Rate | 6 µL/min |
| Compensation Method | Automatic |
| Brand | Beckman Coulter |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | CytoFLEX o |
| Technology Platform | Nanoscale Flow Cytometry |
| Instrument Type | Flow Cytometer |
| Primary Use Case | Research |
| Lasers | 405 nm, 488 nm, 561 nm, 638 nm |
| Fluorescence Detection Channels | 6 |
| Side Scatter (SSC) Detection Channels | 5 |
| Particle Size Detection Range | 40 nm – 1 µm |
| Automated Sample Loading | Yes |
| Compensation Method | Fully Automated |
| Sorting Capability | Optional |
| Sorting Output Ports | 6-way |
| Voltage Adjustment Required | No |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CytoFLEX S Series |
| Technology Pathway | Analytical Flow Cytometry |
| Product Type | Flow Cytometry Analyzer |
| Primary Use Case | Research |
| Laser Configuration | Up to four spatially separated lasers (375 nm, 405 nm, 488 nm, 561 nm) |
| Fluorescence Detection Channels | Up to 13 parameters with full-channel rCV < 3% |
| Optical Resolution | Side Scatter (488 nm) < 300 nm, Violet Side Scatter (405 nm) < 80 nm (vs. polystyrene beads) |
| Sample Flow Rate | 10–240 µL/min (user-selectable in 10/30/60 µL/min presets or fully adjustable) |
| Fluorescence Sensitivity | ≤30 MESF (FITC), ≤10 MESF (PE) at 15-parameter configuration |
| Event Acquisition Rate | Up to 30,000 events/sec (continuous, software-adjustable) |
| Automated Sample Loading | Integrated plate-based autosampler optional |
| Compensation Method | Real-time automatic compensation with saved compensation matrices |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Sorting Flow Cytometer |
| Application Domain | Research |
| Laser Configuration | Up to 4 Lasers (405 nm, 488 nm, 561 nm, 638 nm) |
| Fluorescence Detection Channels | 15 Total (Configurable BPF Filters) |
| Optical Precision | rCV < 3% across all channels |
| Side Scatter Resolution | < 300 nm (488 nm excitation), < 200 nm (405 nm excitation) |
| Sample Flow Rate | 10–100 µL/min |
| FITC Sensitivity (488 nm) | < 30 MESF |
| Cell Acquisition Rate | 40,000 events/sec |
| Sorting Throughput | 30,000 cells/sec |
| Nozzle Diameter | 100 µm |
| Droplet Frequency | 35 kHz |
| Sorting Logic | Quadruple-Stream Sorting with Mixed-Mode and Discard-Capture Capability |
| Compensation | Fully Automated Real-Time Compensation |
| Sample Loading | Integrated Auto-Sampler (40,000 events/sec loading speed) |
| Voltage Adjustment Required | No |
| Biosafety Options | Optional Aerosol Containment Cabinet or Standalone Aerosol Exhaust System |
| Software Platform | CytExpert for CytoFLEX SRT (FDA 21 CFR Part 11–Ready Audit Trail, GLP/GMP-Compliant Data Integrity Features) |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic IVD Instrument |
| Model | DxFLEX |
| Product Category | Clinical Flow Cytometry System |
| Application Domain | In Vitro Diagnostic (IVD) Laboratories |
| Laser Configuration | 3 Lasers / 13 Fluorescence Parameters |
| Fluorescence Sensitivity | ≤30,000 Equivalent Stained Particles (ESPs) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Navios EX |
| Technology Platform | Spectral Flow Cytometry |
| Instrument Type | Clinical-Grade Flow Cytometer |
| Laser Configuration | Up to 3 Lasers |
| Detection Channels | 12 |
| Forward Scatter (FSC) Collection Modes | Wide (1–18°), Narrow (1–8°), Wide Enhanced (optimized for submicron particles) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Navios |
| Product Category | Flow Cytometry Analyzer |
| Intended Use | Clinical Diagnostics |
| Lasers | 405 nm (violet), 488 nm (blue), 638 nm (red) |
| Detection Channels | Up to 10-color capability |
| Fluorescence Sensitivity | <112 MESF (FITC), <78 MESF (PE), <15 MESF (PC5) |
| Forward & Side Scatter Detection | Photodiode-based FSC/SSC |
| Fluorescence Detection | Photomultiplier Tube (PMT)-based |
| Optical System | Solid-state diode lasers with integrated flow cell |
| Flow Cell Dimensions | 150 µm × 460 µm rectangular quartz cuvette |
| Temperature Control | Integrated thermal regulation for optical path stability |
| Data Processing | Real-time digital signal processing |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Regulatory Certification | China NMPA Import Registration No. 20172401770 |
| Compliance | Designed for CLIA- and CAP-aligned clinical laboratories |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Vi-CELL BLU |
| Assay Time | Fast Mode 80 s/sample, Standard Mode 110 s/sample |
| Cell Concentration Range | 2 × 10⁴ to 1.5 × 10⁷ cells/mL |
| Sample Volume | Fast Mode 170 µL, Standard Mode 200 µL |
| Throughput | 96 samples per run |
| Detectable Cell Size | 2–60 µm |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | S3e |
| Product Type | Flow Cytometric Cell Sorter |
| Lasers | 3 lasers (405 nm, 488 nm, 640 nm) |
| Fluorescence Detection Channels | 6 parameters (4 fluorescence + FSC + SSC) |
| Coefficient of Variation (CV) | ≤2.5% for FITC beads |
| Sorting Speed | Up to 100,000 events/sec |
| Sensitivity | ≥125 MESF (Molecules of Equivalent Soluble Fluorochrome) for FITC |
| Sample Temperature Control | 4–35 °C adjustable, ±0.5 °C stability |
| Nozzle Sizes | 70 µm, 85 µm, 100 µm |
| Auto-Calibration | Fully automated hydrodynamic and optical alignment via AutoGimbal™ system |
| Biosafety Compatibility | Certified for operation inside Class I biosafety cabinets |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | TC20 |
| Measurement Time | 30 s |
| Cell Concentration Range | 5 × 10⁴ – 1 × 10⁷ cells/mL |
| Sample Volume | 10 µL |
| Throughput | 2 samples per run |
| Detectable Cell Diameter | 6–50 µm |
| Data Storage | Internal memory for 100 assays |
| Dimensions (W × D × H) | 19 × 15 × 25.4 cm |
| Weight | 2.2 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | ZE5 |
| Product Type | Flow Cytometer |
| Application | Research |
| Lasers | 5 lasers |
| Detection Parameters | 30 parameters |
| Coefficient of Variation (CV) | ≤3% |
| Sample Flow Rate | 3.5 µL/min |
| Fluorescence Sensitivity | ≤10 MESF (Molecules of Equivalent Soluble Fluorochrome) for FITC |
| Event Acquisition Rate | Up to 100,000 events/sec |
| Maximum Data Storage per Acquisition | 100 million events |
| Throughput | 96-well plate in ≤12 minutes |
| Fluidic Velocity | 8 m/sec |
| Software | Everest Flow Cytometry Software |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | ZOE |
| Product Category | Integrated Fluorescent Cell Imaging System |
| Excitation/Emission Filters (Blue Channel) | 355/40 nm / 433/36 nm |
| Excitation/Emission Filters (Green Channel) | 480/17 nm / 517/23 nm |
| Excitation/Emission Filters (Red Channel) | 556/20 nm / 615/61 nm |
| Imaging Sensor | 5 MP, 12-bit CMOS monochrome camera |
| Display | 10.1-inch high-resolution LCD touchscreen (1280 × 768) |
| Objective | 20× achromatic, wide-field mounting (0.70 mm² FOV, ~180% larger than standard 20×) |
| Stage | Motorized XY stage with ±6 mm travel, touch-controlled navigation |
| Illumination | LED-based brightfield (adjustable green LED ring with quadrant masking for oblique illumination) and fluorescence excitation (no warm-up, >10,000 h lifetime) |
| Image Storage | 16 GB internal memory (~2,500 JPEG images) |
| Output Formats | JPEG, TIFF, RAW |
| Software Features | Real-time gain, exposure time, LED intensity, and contrast adjustment |
| Brand | BMG LABTECH |
|---|---|
| Origin | Germany |
| Model | CLARIOstar ACU Ischemia-Reperfusion Research System |
| Application | High-throughput, real-time intracellular oxygen monitoring under physiologically relevant O₂/CO₂-controlled conditions |
| Regulatory Status | Research Use Only (RUO), not for clinical diagnostic use |
| Compliance | Designed to support GLP-compliant workflows and FDA 21 CFR Part 11–ready software configurations (with optional audit trail and user access control) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ECM 399 |
| Price Range | USD $13,500 – $40,500 (FOB) |
| Product Type | Electroporation System for Cell Transfection and Transformation |
| Brand | CARE |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | IBTC-100S |
| Stretch Rate | 1–15% strain per cycle |
| Stretch Frequency | 0.2–5 Hz |
| Waveform | Sinusoidal |
| Static & Dynamic Stretch Modes | Yes |
| Custom Strain Profile Support | Yes |
| Microscopy-Compatible Substrate | Transparent bottom for live-cell imaging |
| Strain Uniformity Across Culture Area | ≥95% |
| Measurement Uncertainty | <1% (engineering strain output) |
| Brand | CARE |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | IBTC-10S |
| Quotation | Upon Request |
| Stretching Frequency Range | 0.2–5 Hz |
| Elongation Range | 1–15% |
| Brand | Chuanyi Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Qi3531 |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Sample Throughput | Up to 20 cell types per analysis session |
| Power Supply | Dual-mode (AC adapter + internal rechargeable battery) |
| Display | Integrated LCD screen with real-time classification summary |
| Brand | KELLER HCW |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SAMPLER1 |
| Pricing | Available Upon Request |
| Product Type | Flow Cytometer |
| Spectral Detection Range | 420–832 nm |
| Dynamic Range | 10⁷·² (log scale) |
| Fluorescence Sensitivity | High |
| Resolution | High |
| Linearity | ≥0.99 |
| Continuous Sample Loading Duration | Up to 30 min |
| Temperature Control | Precise |
| Vibration Damping | Integrated |
| Optical-Electronic Module | Modular Design |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | COUNTESS® II FL |
| Price Range | USD 7,000 – 14,000 (FOB US) |
| Brand | Applitech |
|---|---|
| Model | BF 100 |
| Principle | Trypan Blue Exclusion with Digital Image Analysis |
| Throughput | 8 samples per run |
| Sample Volume per Channel | 15 µL |
| Analysis Time | ≤90 sec for 8 samples |
| Focus | Auto-focus optical system |
| Compliance | FDA 21 CFR Part 11, GMP-aligned user management and audit trail |
| Software | Integrated analysis suite with multi-field imaging, dilution compensation, growth curve generation, and PDF/Excel/TIFF export |
| Consumable | FL8-slide (8-channel disposable chamber slide) |
| Regulatory Support | IQ/OQ/PQ documentation package included |
| Brand | Applitech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | FL 2000 |
| Pricing | Upon Request |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Mira BF |
| Detection Time | 20–50 s |
| Cell Concentration Range | 1×10⁴ – 3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Diameter | 2 – 180 µm |
| Brand | Curiox |
|---|---|
| Origin | South Korea |
| Model | HT2100 |
| Nozzle Flow Rate | 5–20 µL/s |
| Maximum Droplet Volume | 80 µL |
| Microplate Format | 96-well Laminar Wash Plate |
| Total Infusion Flow Rate | 300 mL/min |
| Dilution Factor per Wash Cycle | 3.5× |
| Brand | Curiox |
|---|---|
| Model | Pluto |
| Origin | Jiangsu, China |
| Instrument Type | Automated Liquid Handling & Cell Processing System |
| Plate Compatibility | Standard 96-well plates, 96-well deep-well plates |
| Intended Use | Research-grade flow cytometry sample preparation |
| Configuration Options | Three throughput tiers (Low/Medium/High) with modular accessory support |
| Regulatory Context | Designed for GLP-compliant research environments |