Cell Analysis
Filter
Showing 151–180 of 367 results
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Type | Fully Automated |
| Model | Sefia™ Automated Cell Expansion System |
| Compliance | CE-marked (2006/42/EC), IEC 61010, IEC 61326, ICES-001 Class A, China RoHS SJ/T11364-2014 |
| Software Compliance | Chronicle™ Viewer validated per GAMP™5 and FDA 21 CFR Part 11 |
| Operating Environment | 15–25°C, 20–80% RH (non-condensing), 840–1060 mbar, indoor use only, max. altitude 2000 m |
| Consumables | Single-use FEP or silicone-based disposable kits (e.g., Cat. No. 29716713, 29739346) |
| Integration | Compatible with Chronicle™ Viewer for audit-trail-enabled data management and real-time process monitoring |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sepax C-Pro Cell Processor |
| Type | Fully Automated |
| Compliance | CE (2006/42/EC), IEC 61010, IEC 61326, IEC 62304 |
| Software Integration | Chronicle eSOP, GAMP 5-aligned, FDA 21 CFR Part 11-ready audit trail capability |
| Brand | Cytiva |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Omics Bundle |
| Separation Method | Automated |
| Cell Viability (%) | ≥90% |
| Compatibility | Requires Integration with VIA Freeze™ Uno Controlled-Rate Freezer |
| Intended Use | Research Use Only (RUO), Not for Diagnostic Purposes |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Model | VIA Freeze Uno |
| Type | Fully Automatic |
| Cooling Method | Conductive |
| Compliance | cGMP, 21 CFR Part 11, ISO 13485 (via system integration) |
| Sample Capacity | 24–192 cryovials, up to 250 mL cryobags, cryostraws (with interchangeable trays) |
| Calibration | Supplied with NIST-traceable calibration certificate |
| Qualification | IQ/OQ documentation included |
| Software Integration | Chronicle™ Automation Platform (optional standalone purchase) |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Model | VIA Thaw™ L1000 |
| Type | Fully Automated |
| Regulatory Classification | Import (CE-marked for IVD/medical device use in EU |
| Compliance | Designed to support GMP-compliant cell therapy manufacturing per ISO 13485, ASTM F3276-21 (Standard Guide for Cryopreserved Cellular Product Thawing), and 21 CFR Part 11–ready when used with Chronicle™ software |
| Brand | CytoBuoy (Netherlands) |
|---|---|
| Origin | Netherlands |
| Model | CytoBuoy |
| Application Platform | Buoy-Integrated Autonomous Monitoring System |
| Detection Principle | Pulse-Shape Analysis (PSA) + High-Speed Flow Imaging Cytometry |
| Optical Channels | FWS, SWS, FLR, FLY, FLO |
| Depth Rating | Up to 20 m (with CytoSub module) |
| Data Transmission | Wireless (GSM/3G/4G, optional satellite) |
| Compliance | Designed for GLP-aligned environmental monitoring workflows |
| Software | CytoUSB (acquisition), CytoClus & EasyClus (batch clustering & morphometric analysis) |
| Particle Size Range | 1–500 µm |
| Measurement Modes | In situ profiling (with CTD), vertical剖面, remote-controlled unattended operation |
| Brand | CytoBuoy (Netherlands) |
|---|---|
| Origin | Netherlands |
| Model | CytoSense XR |
| Detection Principle | Laser-scanning flow cytometry with hydrodynamic focusing and synchronized high-resolution imaging |
| Particle Size Range | 0.2–700 µm |
| Concentration Range | 10²–10¹¹ particles/L |
| Sheath Fluid System | Closed-loop recirculating |
| Optical Channels | Forward scatter (FWS), red fluorescence (FLRed, ~680 nm), side scatter (optional), multi-wavelength excitation (488 nm standard, optional 532/640 nm) |
| Imaging Mode | Pulse-profile scanning + triggered micrograph acquisition |
| Data Output | Per-particle parameter vectors (size, shape, pigment distribution, internal structure morphology), time-stamped event files, TIFF/JPEG image stacks |
| Compliance | Designed for GLP-compliant environmental monitoring |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | CytoFLEX nano |
| Particle Detection Range | 40 nm – 1 µm |
| Fluorescence Channels | 6 |
| Scatter Channels | 6 |
| Automated Sample Loading | Yes |
| Software | FCMpass (licensed) |
| Carryover Rate | <1% |
| Intended Use | Research-Grade Nanoparticle & Submicron Vesicle Analysis |
| Regulatory Context | Designed for GLP-compliant lab environments |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China (Manufactured under Beckman Coulter’s global quality system) |
| Type | Analytical Flow Cytometer |
| Laser Configuration | 1–3 lasers (violet 405 nm, blue 488 nm, red 638 nm) |
| Detection Channels | Up to 13 parameters (including FSC, SSC, and fluorescence) |
| Optical Resolution | rCV < 3% across all channels |
| side scatter resolution | < 300 nm (488 nm laser), < 80 nm (405 nm laser) vs. polystyrene beads |
| Flow Rate | Fixed settings at 10, 30, and 60 µL/min |
| user-defined range | 10–240 µL/min |
| Fluorescence Sensitivity | ≤30 MESF (FITC), ≤10 MESF (PE) at 15-parameter configuration |
| Throughput | Up to 30,000 events per second (EPS) |
| Automation | Integrated autosampler with plate loader (96-/384-well compatible) |
| Compensation | Real-time automated compensation (spillover matrix-based) |
| Sorting Capability | Optional integrated cell sorting module (12-way sorting) |
| Voltage Control | User-adjustable PMT voltage per detector |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | CytoFLEX SRT |
| Price Range | USD $15,000–$120,000 (FOB) |
| Technology Platform | Sorting Flow Cytometry |
| Product Type | High-Performance Benchtop Flow Cytometer with Integrated Cell Sorting |
| Intended Use | Research-Only |
| Sample Delivery Rate | 10–100 µL/s (continuously adjustable) |
| Sorting Output | 4-way electrostatic sorting |
| Voltage Adjustment Required | Yes |
| Optical Configuration | V-B-Y-R (Violet-Blue-Yellow-Green-Red) up to 15 fluorescence detectors |
| Biosafety Options | Optional aerosol containment system compatible with Class II biological safety cabinets |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | CytoFLEX SRT |
| Laser Configuration | Up to 4 lasers |
| Fluorescence Channels | Up to 15 parameters |
| Nozzle Size | 100 µm |
| Sheath Pressure Range | As low as 15 psi |
| Sorting Purity | >99% |
| Plate Format Compatibility | 96-well plates |
| Time-to-Ready | ≤21 minutes from power-on to sort-ready state |
| Sorting Modes | Four-way sorting with hybrid (purity/enrichment) mode support |
| Sorting Orientation | Vertical drop-based sorting architecture |
| Brand | Cytosurge |
|---|---|
| Origin | Switzerland |
| Model | FluidFM OMNIUM |
| Type | Fully Automated |
| Category | Life Science Instrumentation / Cell Analysis / Single-Cell Manipulation Platform |
| Brand | CytoTronics |
|---|---|
| Model | Pixel Primo / Pixel Octo |
| Origin | USA |
| Instrument Type | Impedance-Based Real-Time Cellular Analysis Platform |
| Plate Formats | 96-well & 384-well microplates |
| Dimensions (Primo) | 38.1 cm × 14.6 cm × 8.9 cm |
| Dimensions (Octo) | 60.0 cm × 32.5 cm × 58.5 cm |
| Environmental Control (Octo) | Temperature, CO₂/O₂, and Humidity |
| Electrode Channels | Up to 4 programmable electrochemical channels |
| Spatial Resolution | 15 µm |
| Data Acquisition Interval | As low as 15 minutes |
| Detection Principle | Multi-frequency impedance spectroscopy + integrated electrochemical sensing |
| Brand | CytoTronics |
|---|---|
| Model | Pixel Primo |
| Origin | USA |
| Import Status | Imported Instrument |
| Key Specifications | 138,000 microelectrodes per well |
| Spatial resolution | 15 µm |
| Data acquisition interval | as low as 15 min |
| Measurement modalities | label-free impedance imaging, electrophysiology, redox electrochemistry |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | Daxluot-MC |
| Detection Time (Brightfield) | <3 sec |
| Cell Concentration Range | 7×10²–2.5×10⁷ cells/mL |
| Adjustable Sample Height | 50 µm (5 µL), 100 µm (10 µL), 400 µm (40 µL) |
| Cell Diameter Range | 4–400 µm |
| Imaging Resolution | 5 MP brightfield |
| Excitation/Filter | AO 530 nm, PI 620 nm |
| Illumination | LED-based brightfield |
| Sample Stage Material | Hydrophilic quartz glass |
| Focus | Auto- and manual-focus modes |
| Power Supply | 12 V DC |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DEN-1 |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | TAXIScan-FL |
| Price Range | USD 140,000 – 280,000 (FOB Japan) |
| Product Category | Live-Cell Chemotaxis Analysis System |
| Application Domain | Academic & Preclinical Research |
| Excitation Source | None (Requires External Fluorescence Illumination) |
| Detection Channels | 1 (Single-Channel Fluorescence + Brightfield) |
| Spatial Resolution | ≤30 µm |
| Fluorescence Sensitivity | ≥0.1 ng/mL (FITC-equivalent) |
| Imaging Throughput | Up to 12 Concurrent Assays |
| Sample Requirement | As Few as 100 Viable Cells per Assay |
| Temperature Control Range | RT + 3°C to 40°C |
| Microchannel Depths | 4, 5, 6, or 8 µm |
| Objective Lenses | 10×, 20×, 40×, 100× (Oil Immersion Compatible) |
| Filter Sets | Standard B/G/R Cube Configuration |
| Data Output Format | TIFF/AVI Time-Lapse Sequences with Metadata Embedding |
| Software Compliance | FDA 21 CFR Part 11–Ready Audit Trail, GLP-Compliant Experiment Logging |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LC-AMF System |
| Product Category | Live-Cell Time-Lapse Imaging & Electromagnetic Field Exposure Platform |
| CO₂ Input | 5% (v/v) |
| Recirculating Water Bath Flow Rate | 320 mL/min |
| Temperature Stability | ±0.2 °C |
| Max Frequency | 951.5 kHz (at 13.2 mT) |
| Min Frequency | 128.8 kHz (at 20 mT) |
| Dimensions | 127 × 85 × 26 mm |
| Compatible Vessel | 35 mm Tissue Culture Dish |
| Frequency Tuning Range | 128.8–951.5 kHz (dependent on inductance/capacitance matching) |
| Brand | Eureka Bio |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | CellSep Pro |
| Price Range | USD 70,000 – 140,000 (approx.) |
| Type | Fully Automated |
| Sample Volume | 10 mL – 500 mL |
| Cell Processing Capacity | Configurable per protocol (e.g., PBMC isolation from 30–150 mL whole blood |
| Temperature Control | Ambient (no active thermal regulation) |
| Maximum Culture Volume | Customizable upon request |
| Gas Pressure Control | Not applicable |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FFX-TG |
| Price Range | USD 13,500 – 40,500 (FOB Hamburg) |
| Separation Method | Fully Automated |
| Leukocyte (Nucleated Cell) Recovery Rate | ≥95% |
| Cell Viability | ≥90% |
| Sample Throughput | Up to 4 independent tissue samples per run |
| Tissue Input Mass | 10–300 mg |
| Processing Time | 2–3 minutes per sample |
| Rotor-Stator Gap | 100 µm |
| Brand | FlowCam |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowCam 8000 |
| Pricing | Available Upon Request |
| Brand | Fluicell |
|---|---|
| Origin | Sweden |
| Model | Fluiwell-BioPen |
| Flow Precision (PRIME chip) | 7–25 nL/s |
| Solution Switching Speed | Sub-second (<1 s) |
| Nozzle Compatibility | Universal microscope integration (standard inverted & upright configurations) |
| Chip Types | PRIME (high-precision, low-volume) and FLEX (modular, multi-channel) disposable chips |
| Control Interface | PC-based Fluicell Control Software v3.x |
| Regulatory Compliance | CE-marked for research use only (RUO), compliant with ISO 13485 design controls for medical device components |
| Brand | FuTech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | SN415 |
| Pricing | Upon Request |
| Technology Platform | Nanoscale Flow Cytometry |
| Instrument Type | High-Parameter Flow Cytometer with Sorting Capability |
| Intended Use | Research-Only |
| Laser Configuration | Up to 4 Lasers |
| Detection Channels | 2 Scatter (FSC/SSC) + Up to 13 Fluorescence Parameters |
| Acquisition Rate | 10,000 Events per Second |
| Compensation | Automated and Manual Compensation Support |
| Nozzle Sizes | 70 µm, 85 µm, 100 µm, 130 µm |
| Sorting Capability | Yes |
| Sorting Throughput | 10,000 Events per Second |
| Sorting Output | 4-Way Sorting |
| Voltage Adjustment Required | Yes |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Fully Automated Cell Processing System |
| Model | CTS Rotea |
| Sample Volume Range | 50 mL – 20 L |
| Output Volume Range | As low as 5 mL |
| Sterility | Closed, Single-Use Disposable Kit Based |
| Regulatory Designation | Designed for Clinical and Commercial cGMP Manufacturing of Cell Therapies |
| Software Compliance | Supports 21 CFR Part 11–compliant audit trails and electronic signatures (when configured with Thermo Fisher’s DeltaV-integrated digital platform) |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Model | DEN-1 |
| Light Source | LED (565 ± 15 nm) |
| Measurement Range | 0.3–15.0 McFarland Units |
| Accuracy | ±3% |
| Standard Deviation (3.0 McF) | ±0.1 McF |
| Measurement Time | 1 s |
| Sample Tube OD | 18 mm (16 mm with D16 adapter) |
| Sample Volume | ≥2 mL |
| Display | 2-digit LED |
| Power Supply | 12 V, 300 mA |
| Operating Temperature | 4–45 °C |
| Dimensions (W×D×H) | 165 × 115 × 75 mm |
| Weight | 0.9 kg |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Gravite® |
| Price | Upon Request |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | easyCyte 8 |
| Product Category | Flow Cytometer |
| Laser Configuration | Dual-laser (488 nm blue + 635 nm red) |
| Fluorescence Channels | 6 (Green, Yellow, Red1, Red2, NIR1, NIR2) + 2 Scatter (FSC, SSC) |
| Sample Format | 1.2 mL or 1.5 mL microtubes |
| Software Platform | guava InCyte v3.x |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer | Merck KGaA, Darmstadt, Germany |
| Product Type | Benchtop Flow Cytometer |
| Laser Configuration | 488 nm Blue Laser + 638 nm Red Laser |
| Fluorescence Channels | 6 (Green, Yellow, Red1, Red2, NIR1, NIR2) + 2 Scatter (FSC, SSC) |
| Detection Optics | High-Transmission Bandpass Filters (e.g., 525/30 nm, 583/26 nm, 692/46 nm, 661/19 nm, 785/70 nm ×2) |
| Sample Format | 96-Well Microplate (Standard ANSI/SLAS), 1.2–1.5 mL Tubes |
| Automation | Integrated 96-Well Plate Autoloader |
| Software | Guava InCyte v3.x (FDA 21 CFR Part 11–Ready, Audit Trail Enabled, GLP/GMP-Compatible Workflow Support) |
| Brand | Hanuo |
|---|---|
| Model | HN-6020SE |
| Origin | Shanghai, China |
| Application | Research-grade |
| Temperature Range | +5°C to 60°C (above ambient) |
| Temperature Accuracy | ≤ ±0.5°C |
| Temperature Uniformity | ≤ ±0.5°C |
| Display Resolution | 0.1°C |
| Timer Range | 1 min – 99 h 59 min |
| Oscillation Speed | 50–300 rpm |
| Horizontal Amplitude | 20 mm |
| Platform Dimensions | 230 × 230 mm |
| Chamber Height | 182 mm |
| Max Load Capacity | 4.0 kg |
| Heating Time (to 60°C) | ≤ 15 min |
| Power Input | AC 220 V, 50–60 Hz |
| Rated Power | 350 W |
| Fuse | 250 V, 3 A, Φ5 × 20 mm |
| Dimensions (W × D × H) | 420 × 320 × 338 mm |
| Weight | Not specified |
| Safety Features | Dual (hardware + software) overtemperature protection, lid-open auto-pause, power-loss auto-resume, built-in temperature calibration |
| Motor Type | Brushless DC motor |
| Noise Level | Low |
| Compliance | Designed for GLP-aligned research environments |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | HI-9 |
| Compatible Capillary Outer Diameter | 1.0 mm |
| Weight | 18.6 g |
| Length | 155 mm |
| Includes | Silicone Rubber Gasket (HI01PK01), Cleaning Rod |
| Mounting Type | Standard Connector-Based Fixture with Rotatable HIR Clamp |