| Brand | Aligned Genetics |
|---|---|
| Origin | South Korea |
| Model | L10001 |
| Counting Time | <10 s (manual focus), <15 s (auto-focus) |
| Cell Concentration Range | 5 × 10⁴ – 1 × 10⁷ cells/mL |
| Cell Size Range | 3–60 µm (optimal: 8–30 µm) |
| Viability Range | 0–100% |
| Image Resolution | 5 MP |
| Output Formats | TIFF (annotated), PDF reports |
| Dimensions (W×D×H) | 16 × 18 × 28 cm |
| Weight | 1.6 kg |
| Power Input | 100–240 VAC, 50/60 Hz |
| DC output | 12 VDC, 3.3 A |
| Brand | Aligned Genetics |
|---|---|
| Origin | South Korea |
| Model | L30001 |
| Detection Time | 30–60 s |
| Cell Concentration Range | 5 × 10⁴ – 1 × 10⁷ cells/mL |
| Sample Volume | 10 µL |
| Detectable Cell Size Range | 1–90 µm |
| Excitation Wavelength | 470 ± 20 nm |
| Emission Wavelengths | 530 ± 25 nm and 600 nm (long-pass) |
| Light Source | LED |
| Image Resolution | 5 MP |
| Display | 800 × 480 pixels |
| Dimensions (W×D×H) | 22 × 21 × 9 cm |
| Weight | 1.8 kg |
| Brand | Axion BioSystems |
|---|---|
| Model | Maestro Z / ZHT |
| Origin | USA |
| Manufacturer | Axion BioSystems, Inc. |
| Category | Imported |
| Pricing | Available Upon Request |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | guava easyCyte 6HT-2L |
| Pricing | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | CytoDirect |
| Sample Volume | 20 µL |
| Pixel Size | 1.1 µm × 1.1 µm |
| Cell Diameter Range (Counting) | 2–80 µm |
| Display Resolution | 1280 × 800 px |
| Screen Size | 7 in |
| Dimensions (H×W×D) | 60 mm × 128 mm × 260 mm |
| Weight | 1.11 kg |
| Detection Technology | Digital Holographic Microscopy |
| Autofocus | Yes |
| Processing Time | < 15 s |
| Total Imaging Area | 31.28 mm² |
| Sensor Count | 2 |
| Battery | Rechargeable Li-ion |
| Power Input | USB-C |
| Connectivity | Wi-Fi, Ethernet |
| Data Export Formats | CSV, PDF, PNG, RAW |
| Sterilizable | Yes |
| Portability | Yes |
| CV (at > 5 × 10⁶ cells/mL) | ≤ 5% |
| Cell Types Supported | B cells, CHO, HEK293, HeLa, MSC, NK cells, PBMC, RBC, Sf9, T cells, iPSC, monocytes, granulocytes, *Saccharomyces cerevisiae*, oval/round plant cells |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Model | Scepter 3.0 |
| Measurement Time | ≤30 s per sample |
| Sample Volume | 5 µL |
| Cell Size Detection Range | 10–30 µm |
| Cell Concentration Range | 1×10⁴–1×10⁷ cells/mL |
| Throughput | Up to 100 samples per day |
| Principle | Electrical Impedance (Coulter Principle) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Miltenyi Biotec |
|---|---|
| Origin | Germany |
| Model | autoMACS® Pro |
| Automation Level | Fully Automatic |
| Sample Throughput | Up to 6 × 5 mL, 5 × 15 mL, or 3 × 50 mL tubes per run |
| Max Total Cells per Sample | 4 × 10⁹ |
| Max Magnetically Labeled Cells per Sample | 2 × 10⁸ |
| Sample Volume Range | 0.2–50 mL |
| Compatible Starting Materials | Whole blood, PBMCs, bone marrow, dissociated tissues, tumor digests, cultured cells (primary & cell lines) |
| Species Compatibility | Human, mouse, rat, non-human primates, and others via indirect MicroBeads |
| Column Types | Reusable autoMACS Columns (single or dual configuration) |
| Separation Modes | Positive selection, untouched isolation, depletion |
| Regulatory Compliance | Designed for GLP-compliant workflows |
| Dimensions (w × d × h) | 605 × 343 × 392.5–454 mm (with MiniSampler: 605 × 455 × 392.5–454 mm) |
| Cooling System | Integrated Chill Racks (2–8 °C sample/ reagent storage) |
| Brand | Miltenyi Biotec |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | MACSima |
| Pricing | Upon Request |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CellXpress.ai |
| Pricing | Upon Request |
| Temperature Control | Yes |
| Humidity Control | Yes |
| Incubation Capacity | Up to 44 microplates (2 stackers) or 154 microplates (7 stackers) |
| Imaging Speed | 3.5 minutes per 96-well plate (single channel, single field of view) |
| Environmental Control | CO₂, temperature, and humidity regulation |
| Excitation Wavelengths | 7 LED sources, 365–730 nm |
| Camera Resolution | 24 MP |
| Objective Lenses | 2×, 4×, 10×, 20×, 40× |
| Imaging Channels | Brightfield + up to 6 fluorescence channels |
| AI Decision Engine | Rule-based machine learning for real-time morphological assessment |
| Air Filtration | HEPA filtration + integrated UV sterilization |
| Predefined & Custom Protocols | Yes |
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ImageXpress HCS.ai |
| Pricing | Available upon Request |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | IXM-4 |
| Temperature Control | 30–40 °C ±0.5 °C |
| Brand | POWCLIN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MSFLO |
| Pricing | Upon Request |
| Technology Platform | Mass Cytometry (ICP-TOF) |
| Instrument Type | Flow Cytometer for Single-Cell Metal Isotope Detection |
| Primary Use Case | Academic & Translational Research |
| Brand | MSHOT |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MCS21 |
| Pricing | Upon Request |
| Imaging Modes | Brightfield, Phase Contrast, Fluorescence (Dual-Channel: Blue 475/30 nm & Green 560/40 nm) |
| Light Source | 625 nm Red LED for Phase Contrast |
| Objective | 10×/0.25 Phase Contrast |
| Z-Axis Focus | Motorized Autofocus |
| Camera | 5 MP, 2/3" CMOS, 40 fps |
| Software Architecture | Client/Server (C/S), Remote Control Enabled |
| Environmental Range | 5–42 °C, 5–95% RH |
| Power & Data | USB + DC Input |
| Brand | Dolomite Bio |
|---|---|
| Model | Nadia Innovate |
| Origin | United Kingdom |
| Instrument Type | Microfluidic Droplet-Based Single-Cell Capture Platform |
| Throughput | Up to 50,000 cells per run (max. 6,000 cells per sample) |
| Parallel Channels | 1–8 independent microfluidic lanes |
| Temperature Control Range | 4–40 °C (±0.5 °C stability) |
| Pressure Control | Digital pneumatic regulation (0–300 kPa, resolution 1 kPa) |
| Stirring Speed | 0–1,200 rpm (magnetic bead suspension optimization) |
| Real-Time Imaging | Integrated high-resolution CMOS camera (1280 × 960 px, 30 fps), calibrated for droplet size and monodispersity assessment |
| Compatibility | Mammalian cells (5–40 µm), nuclei, spheroids, and agarose-encapsulated samples |
| Software Interface | Nadia Instrument Control Suite v3.2 (Windows-based, audit-trail enabled) |
| Brand | NanoEntek |
|---|---|
| Origin | South Korea |
| Model | ExTransfection |
| Type | Fully Automated |
| Compliance | CE-IVD, ISO 13485–certified manufacturing environment |
| Application Focus | Primary cells, stem cells, CRISPR RNP delivery, GMP-compatible process development |
| Brand | Axion BioSystems |
|---|---|
| Origin | Netherlands |
| Manufacturer | Axion BioSystems |
| Product Type | Imported Instrument |
| Model | Omni |
| Cell Analysis Speed | Full-plate brightfield/fluorescence scan in ≤10 minutes |
| Brand | On-chip |
|---|---|
| Origin | Japan |
| Type | Fully Automated |
| Sorting Speed | 1,000 events/sec |
| Sortable Cell Range | 100 – 10,000,000 cells |
| Minimum Sorting Pressure | 0.3 PSI |
| Droplet Volume | Picoliter-scale |
| Compatible Sheath Fluids | Aqueous buffer or oil |
| Max Particle Diameter | >100 µm |
| On-Chip Integration | Detection, Separation, Recovery |
| Chip Format | Disposable, Single-Use Microfluidic Cartridge |
| Brand | On-chip |
|---|---|
| Origin | Japan |
| Model | On-chip SPiS |
| Separation Method | Fully Automated |
| Maximum Sample Diameter | 200 µm |
| Dispensing Accuracy | >90% |
| Consumable | Disposable Tips |
| Imaging System | Integrated CCD Camera |
| Dilution Capability | On-board Automatic Dilution |
| Brand | ZhiGuang Biotech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OptoBot®1000 |
| Type | Fully Automated System |
| Dimensions (W×D×H) | 120 × 65 × 177 cm |
| Net Weight | 500 kg |
| Brand | PrismTech |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | LS450 |
| Pricing | Available Upon Request |
| Brand | Aligned Genetics |
|---|---|
| Origin | South Korea |
| Model | Q10001 |
| Detection Time | 30 s |
| Cell Concentration Range | 2 × 10⁵ to 1 × 10⁹ cells/mL |
| Sample Loading Volume | 5–6 µL |
| Measured Volume per Analysis | 0.09 µL (across 10 fields of view) |
| Detectable Cell Size Range | 0.3–50 µm |
| Brand | Raymetech |
|---|---|
| Model | RM-M01G |
| Origin | Jiangsu, China |
| Category | Domestic |
| Distribution Type | Authorized Distributor |
| Pricing | Upon Request |
| Brand | Raymetech |
|---|---|
| Model | SCA Series |
| Origin | Jiangsu, China |
| Instrument Type | Real-time in situ single-cell biochemical analyzer |
| Sample Format | Live cells, tissue sections, in vivo preparations |
| Detection Modalities | Electrochemical, optical (fluorescence/absorbance), and hybrid dual-signal readout |
| Compliance Context | Designed for GLP-compliant research environments |
| Software Interface | Windows-based acquisition and analysis suite with timestamped metadata logging, ROI-based quantification, and kinetic trace export (CSV, HDF5) |
| Brand | Sartorius |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CellCelector Flex |
| Separation Method | Fully Automated Image-Guided Microaspiration |
| Brand | Sartorius |
|---|---|
| Origin | Shanghai, China |
| Model | CellCelector Flex |
| Separation Method | Fully Automated |
| Regulatory Compliance | GLP/GMP-Compliant Workflow Architecture |
| Imaging Modes | Brightfield, Phase Contrast, Fluorescence |
| Throughput | Up to 100+ single-cell picks per hour |
| Pick Accuracy | >95% for targeted subpopulations |
| Viability Post-Pick | ≥95% for monoclonal applications |
| Minimum Dispense Volume | ~1 nL |
| Compatible Vessels | Standard microplates (6–1536-well), Petri dishes, slides, filters, chips, PCR tubes, custom substrates |
| Brand | Sartorius |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Incucyte® CX3 |
| Temperature Control | 37 °C |
| Humidity Control | >90% RH |
| Imaging Mode | Spinning-Disk Confocal (optional) |
| Throughput | Up to 6 microplates simultaneously |
| Temporal Resolution | Configurable per experimental protocol |
| Software License | Unlimited Concurrent Users |
| Brand | Sartorius |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Incucyte S3 |
| Pricing | Available Upon Request |
| Imaging Throughput | Experiment-Dependent |
| Brand | Sartorius |
|---|---|
| Origin | USA |
| Model | Incucyte S3, Incucyte SX1, Incucyte SX5 |
| Imaging Modes | Phase Contrast, Green Fluorescence (e.g., GFP), Red Fluorescence (e.g., RFP/mCherry) |
| Objective Lenses | 4×, 10×, 20× motorized auto-focus |
| Throughput | Up to 6 multiwell plates (96-well or 384-well) per run |
| Environmental Integration | Designed for continuous operation inside standard CO₂ incubators (37 °C, 5% CO₂, humidified) |
| Software Platform | Incucyte® Base Software v2023.1+ with VesselView™, PlateGraph™, and Mask-based analysis modules |
| Compliance | Supports audit trails, user access control, and electronic signatures compliant with FDA 21 CFR Part 11 and GLP/GMP workflows |
| Data Output | Time-lapse image stacks, quantitative metrics (confluence %, object count, neurite length, spheroid area/volume, migration distance), exportable to CSV, PNG, TIFF, and PDF |
| Brand | Sartorius |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Incucyte® SX1 |
| Pricing | Available Upon Request |
| Imaging Throughput | Experiment-Dependent |