Chemical Analysis Instruments
Filter
Showing 3001–3030 of 4337 results
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Instrument Type | Powder X-ray Diffractometer |
| Model | SmartLab SE |
| X-ray Generator Power | 3 kW |
| Goniometer Radius Options | 185 mm (standard), 285 mm (optional), 280 mm (TTR configuration) |
| Optical Configurations | Automated切换 between Bragg-Brentano (focused beam) and parallel-beam geometries |
| Detector | Rigaku HyPix-400 or equivalent high-speed 2D photon-counting detector |
| Safety Enclosure | Interlocked, fail-safe shutter-equipped X-ray housing |
| Goniometer Orientation | Horizontal |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Supermini200 |
| Instrument Type | Scanning WDXRF |
| X-ray Tube Power | 200 W |
| Elemental Range | O (8) to U (92) |
| Cooling | Air-cooled (no liquid nitrogen or external water cooling required) |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | ZSX Primus II |
| Excitation Source | End-window Rh-target X-ray tube (3 kW or 4 kW) |
| High-voltage Generator | High-frequency inverter type |
| Max. Output | 60 kV / 150 mA (4 kW) |
| Stability | ±0.005% (against ±10% AC line fluctuation) |
| Cooling | Integrated water-cooling system |
| Sample Changer Capacity | Up to 48 positions |
| Sample Dimensions | Ø51 mm × 40 mm (H) |
| Analyzed Area | Up to Ø35 mm |
| Sample Rotation | 30 rpm |
| Primary Beam Filters | Al, Ti, Cu, Zr (4-position auto-switch) |
| Collimators | 6 automatic apertures (Ø35, 30, 20, 10, 1, 0.5 mm) |
| Divergence Slits | 3 types (standard, high-resolution, ultra-light-element option) |
| Receiving Slits | SC and F-PC compatible |
| Goniometer | Independent θ–2θ drive |
| Angular Range | SC: 5°–118°, F-PC: 13°–148° |
| Max. Scan Speed | 1400°/min (2θ) |
| Continuous Scan Rate | 0.1–240°/min |
| Crystal Changer | 10-position auto-exchange |
| Standard Crystals | LiF(200), Ge, PET, RX25 |
| Optional Crystals | LiF(220), RX4, RX9, RX35–RX80, RX61F, TAP |
| Vacuum System | Dual-chamber rapid evacuation (dual-pump configuration) |
| Detectors | SC scintillation counter (1000 kcps linearity) for heavy elements |
| Pulse Height Analyzer (PHA) | Auto-adjustment (PAS, Rigaku patent) |
| F-PC Anode Wire Cleaning | Automatic thermal cleaning (ACC, Rigaku patent) |
| Optional Accessories | He purge module (with baffle), temperature-controlled sample stage (36.5 °C), CCD-based micro-imaging (100 µm resolution, 0.5 mm micro-area analysis & mapping), r-θ sample stage (Rigaku patent) |
| Software | NEW SQX (qualitative ID, background subtraction, smoothing, peak deconvolution, calibration curve method per JIS, matrix correction, standardless quantification, EZ-scan templates, auto-aperture selection, precision testing, email reporting, multi-standard management) |
| Compliance | Designed for GLP/GMP environments |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ZSX Primus IV |
| Price Range | USD 210,000 – 280,000 (FOB Yokohama) |
| Instrument Type | Scanning WDXRF |
| X-ray Tube Power | 4 kW |
| Elemental Coverage | Beryllium (Be, Z=4) to Curium (Cm, Z=96) |
| Brand | ROOKO |
|---|---|
| Model | LX-9830GA |
| Type | Benchtop Voltage Drop Analyzer |
| Measurement Parameters | Contact Resistance, Voltage Drop, Current, Open-Circuit Voltage, Temperature |
| Current Range | 0–300 A (selectable ranges: 0–40 A / 0–60 A / 0–100 A / 0–200 A / 0–300 A) |
| Voltage Range (open-circuit) | 0–12 V / 0–24 V / 0–30 V (optional) |
| Voltage Drop Range | 0–199.99 mV |
| Resolution | 0.01 mV (voltage drop), 0.01 A (current), 0.01 V (voltage) |
| Accuracy | ±1% of reading |
| Test Time Setting | 0.01 s – 99.99 h |
| Temperature Measurement Range | 0–25 °C (integrated sensor) |
| Compliance Standards | QC/T 29106–2004, QC/T 730–2005, ISO 6722:2002, GB/T 2951–1997, GB/T 3048–1994, QC/T 413–2002, SAE USCAR-38:2009 |
| Interface Options | RS-232, USB 2.0 |
| Data Management | Password-protected instrument configuration, pass/fail counting (0–99999), audible/visual alarm on limit violation |
| External Integration | PLC control interface, PC software (optional), printer support, custom fixture compatibility |
| Brand | Tlyon (Distributor) |
|---|---|
| Origin | Hungary |
| Manufacturer | RotaChrom GmbH |
| Instrument Type | Benchtop Centrifugal Partition Chromatograph |
| Software Components | CPC Simulator, CPC Visualizer |
| Flow Rate Range | 0.1–25 mL/min |
| Sample Load Capacity | 10 mg–5 g per cycle |
| Detection | UV-Vis (200–600 nm), optional ELSD/MS interface |
| Fraction Collection | Automated, timed or peak-triggered |
| Compliance | GLP-ready architecture, audit trail-capable software logging, ISO/IEC 17025-aligned operation |
| Brand | dc-energies |
|---|---|
| Disk Diameter | 5.61 mm |
| Ring Outer Diameter | 15.0 mm |
| Material | Glassy Carbon Disk / Platinum Ring |
| Insulator | PTFE Shroud |
| Max Rotation Speed | 3000 rpm |
| Collection Efficiency | 37% |
| Operating Temperature | ≤25 °C |
| Origin | Hubei, China |
| Instrument Type | Electrochemical Working Electrode |
| Brand | Antec |
|---|---|
| Origin | Netherlands |
| Model | ROXY™ EC |
| Application | Online Electrochemical Cell for LC-MS Coupling |
| Compatibility | Universal MS Interface (Agilent, Thermo Fisher, Waters, SCIEX, Shimadzu) |
| Configuration | Flow-through electrochemical flow cell with integrated electrode cartridge and MS-compatible solvent handling |
| Regulatory Context | Designed for GLP-compliant metabolic stability screening and oxidative stress simulation studies |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ROXY |
| Pricing | Available Upon Request |
| Potentiostat | ROXY Potentiostats DCC |
| Autosampler | AS 110 (Cool, Micro, 10-Position Vial) |
| LC Pump | LC 110 |
| Reactor Cell | Integrated with Multi-Electrode Detection (MD) and Gas Collection (GC) Electrodes |
| Organizer | OR 110 |
| Software | Clarity Chromatography Data System |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | RP-92 |
| Pricing | Upon Request |
| Instrument Type | Online/Field-Deployable |
| Analytical Principle | Cold Vapor Atomic Fluorescence Spectrometry (CV-AFS) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RQflex 20 |
| Price | Upon Request |
| Brand | Ruihai Photonics (Oceanhood) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | PL980 |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Spectral Resolution | ~4 nm @ 25 µm slit |
| Wavelength Accuracy | ≤3% peak-to-peak (@ 2 hrs) |
| Excitation Wavelength | 976 ± 3 nm, Linewidth < 0.2 nm |
| Laser Power Stability | ≤3% P-P (@ 2 hrs) |
| Laser Lifetime | 10,000 hrs |
| Output Power Range | 0–500 mW adjustable |
| Optical Density (OD) of Notch Filter | OD8 |
| Probe Working Distance | 7.5 mm |
| Probe Fiber Length | ~1.5 m |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 5–80% RH |
| Excitation Fiber Core | 105 µm VIS-NIR |
| Emission Collection Fiber Core | 200 µm VIS-NIR |
| Spectral Range | 1000–1700 nm |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable |
| Instrument Category | Fourier Transform |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | 0.01 cm⁻¹ |
| Scan Speed | 1 scan per 60 seconds |
| Signal-to-Noise Ratio (SNR) | 45,000:1 |
| Wavenumber Accuracy | ≤0.5 cm⁻¹ |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Instrument Type | Portable Handheld Raman Spectrometer |
| Model | AT-RS200 |
| Spectral Range | 200–3200 cm⁻¹ (Raman), 190–1100 nm (UV-Vis) |
| Spectral Resolution | ≤1 cm⁻¹ (Visible Raman), ≤2 cm⁻¹ (UV Raman) |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Repeatability | ≤±0.15 cm⁻¹ |
| Detection Modalities | Surface-Enhanced Raman Scattering (SERS), UV-Vis Absorption Spectrophotometry, Colloidal Gold Immunochromatographic Assay (CGIA) |
| Total Assay Coverage | ~600 analytes across food safety, environmental monitoring, and veterinary medicine |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Excitation Wavelength | 785 nm |
| Spectral Range | 200–3350 cm⁻¹ |
| Spectral Resolution | 4.5–10 cm⁻¹ (best ≤4.5 cm⁻¹ at 912 cm⁻¹) |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.15 cm⁻¹ |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Pilot600 |
| Instrument Type | Dynamic Axial Compression (DAC) System |
| Pump Material | 316L Stainless Steel (PEEK optional) |
| Flow Rate Range | 0.01–600.00 mL/min (gradient mode) |
| Flow Accuracy | ±0.5% |
| Maximum Pressure | 10 MPa |
| Pressure Pulsation | ≤0.2 MPa |
| Gradient Types | Step, Linear, Real-time Adjustable |
| Minimum Gradient Increment | 1% |
| Detection Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Absorbance Range | 0–2 AU |
| UV-Vis Light Source | Imported Deuterium + Tungsten Lamps |
| Sample Injection | Manual 10 mL loop (customizable loops available) |
| Injection Modes | Solid or Liquid Loading |
| Power Supply | 220 V ±10%, 50 Hz |
| Control Interface | Graphical UI via USB/RS-232 |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | QP-0010 |
| Instrument Type | Quaternary Pump |
| Maximum Pressure | 42 MPa |
| Flow Rate Range | 0.001–10 mL/min |
| Flow Accuracy | ±0.1% |
| Flow Precision (RSD) | ≤0.1% |
| Brand | Sanotac |
|---|---|
| Model | S-0150 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Isocratic Pump |
| Max. Operating Pressure | 50 MPa (7,250 psi) |
| Flow Rate Range | 0.001–10 mL/min |
| Flow Accuracy | ±0.1% |
| Flow Precision (RSD) | ≤0.1% |
| Pressure Pulsation | ≤0.1 MPa |
| Flow Increment | 0.001 mL/min |
| Fluid Path Materials | 316L Stainless Steel, Sapphire, PTFE, Ceramic |
| Connection | 1/16″ Standard Fittings |
| Display | 256×64 Dot Matrix LCD with Backlight |
| Communication | RS232 & USB (standard), RS485/RS422 (optional) |
| Protocols | Sanotac Proprietary, Modbus RTU/ASCII |
| Power Supply | 85–264 VAC, 50 Hz |
| Dimensions | 370 × 240 × 152 mm |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | SP1020 |
| Max. Operating Pressure | 20 MPa |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Increment | 0.01 mL/min |
| Flow Accuracy | ±0.5% |
| Flow Precision (RSD) | ≤0.1% |
| Pressure Pulsation | ≤0.2 MPa |
| Display | 256×64 dot-matrix backlit LCD |
| Control Interface | Front-panel keypad + RS232/USB open communication protocol compliant with ASTM E1381 and FDA 21 CFR Part 11 audit trail requirements |
| Brand | Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Vial Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve & Transfer Line Temperature Range | 40–220 °C |
| Temperature Control Accuracy | ±1 °C |
| Quantitative Loop Volume | 1 mL |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Sampling Time | 0–30 min |
| Pressurization Time | 0–999 s |
| Injection Time | 0–999 s |
| Bake-out Time | 0–30 min |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | 5041 |
| Measurement Range | ±100 mV |
| Resolution | 1 mV |
| Accuracy | ±0.5% FS |
| Power Supply | Two AAA batteries (1.5 V × 2) |
| Dimensions | 39 × 25 × 176 mm |
| Weight | 95 g |
| IP Rating | IP57 |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Model | LabSen873 |
| Instrument Type | Pen-Style Electrode |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 1–13 pH |
| Resolution | 0.1 pH |
| Accuracy | ±0.1 pH |
| Calibration Buffers | pH 4.00, 7.00, 10.00 |
| Temperature Range | 0–80 °C |
| Body Material | Lead-Free Glass |
| Bulb Shape | Cylindrical |
| Reference System | Ag/AgCl |
| Junction Type | Dual-Liquid Junction with Movable Sleeve |
| Internal Reference Electrolyte | 3 M KCl (Gelled) |
| Salt Bridge Solution | 1 M LiCl |
| Soaking Solution | 3 M KCl |
| Dimensions | Φ12 × 130 mm |
| Connector | BNC |
| Cable | Φ3 mm × 1 m |
| Integrated Temperature Sensor | Yes (for Automatic Temperature Compensation) |
| Brand | SANXIN Peirui |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | −2.00 to 19.99 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Temperature Compensation Range | 0–110 °C (ATC) |
| Input Impedance | ≥1 × 10¹² Ω |
| Stability | ±0.01 pH / 3 h |
| Data Storage Capacity | 600 sets |
| Storage Content | Sample ID, pH value, temperature, ATC/MTC mode, date & time |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions & Weight | 160 × 190 × 70 mm / 880 g |
| Protection Rating | IP54 |
| Certifications | ISO 9001:2000, CE, CMC |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Model | MP512 |
| Instrument Type | Benchtop |
| Parameter Type | Single-Parameter (pH/mV/°C) |
| pH Range | −2.000 to 19.999 pH |
| pH Resolution | 0.001 pH |
| pH Accuracy | ±0.002 pH |
| mV Range | −1999.9 to +1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.03% FS |
| Temperature Range | −10 to 110 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.4 °C |
| Input Impedance | ≥3 × 10¹² Ω |
| Input Current | ≤1 × 10⁻¹² A |
| Stability | ±0.002 pH / 3 h |
| ATC Range | 0 to 110 °C |
| Data Storage | 600 sets |
| Storage Content | Measurement ID, pH/mV value, temperature, ATC/MTC status, date & time |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| IP Rating | IP54 |
| Certifications | ISO 9001:2000, CE, CMC |
| Operating Environment | 15–30 °C (for 0.001-level accuracy), ≤75% RH |
| Brand | Sanxin Peirui (SANXIN) |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop |
| Parameter Type | Single-parameter (pH/mV/°C) |
| pH Range | -2.000 to 19.999 pH |
| pH Resolution | 0.1 / 0.01 / 0.001 pH |
| mV Resolution | 0.1 mV |
| Temperature Resolution | 0.1 °C |
| pH Accuracy (Meter) | ±0.002 pH |
| (System w/ 2503-C electrode) | ±0.01 pH |
| mV Accuracy | ±0.03% FS |
| Temperature Accuracy | ±0.4 °C (5–60 °C), ±0.8 °C (other ranges) |
| Input Current | ≤1 × 10⁻¹² A |
| Input Impedance | ≥3 × 10¹² Ω |
| Stability | ±0.002 pH / 3 h |
| Temperature Compensation | Automatic or Manual, 0–100 °C |
| Buffer Recognition | 13 standard pH buffers (NIST, DIN, Chinese GB, and custom series) |
| Measurement Modes | Stable Read, Timed Read, Continuous Read |
| Special Modes | High-Purity Water pH, Ammoniated Pure Water pH, ORP (vs. SHE) |
| Data Storage | 600 records (ID, value, temperature, ATC/MTC status, date/time) |
| Interface | RS232 |
| Power | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| Environmental Rating | IP54 |
| Certifications | ISO 9001:2000, CE, CMC |
| Operating Conditions | 15–30 °C (for 0.001-class performance), ≤75% RH |
| Brand | SANXIN Peirui |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MP513 |
| Detection Parameter | Single-Parameter (Conductivity) |
| Portability | Benchtop |
| Application Environment | Laboratory |
| Conductivity Range | 0–200 mS/cm (5 auto-ranging segments) |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | −10 to +110 °C |
| Accuracy | ±1.0% FS (Conductivity), ±1.5% FS (Overall Specification) |
| Minimum Resolution | 0.001 µS/cm |
| Temperature Compensation | Automatic (0–50 °C), ATC-enabled electrode |
| Data Storage | 100 sets |
| Interface | RS232 with GLP-compliant software |
| IP Rating | IP54 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions & Weight | 160 × 190 × 70 mm / 880 g |
| Brand | Sanxin Peirui |
|---|---|
| Origin | Shanghai, China |
| Model | MP525 |
| Instrument Type | Laboratory-grade pH/ORP/Dissolved Oxygen Analyzer |
| Measurement Principles | Potentiometric pH/ORP, Polarographic Dissolved Oxygen |
| Compliance | GLP-compliant design, IP54 rated, ISO 9001:2008 certified, CE & CMC marked |
| Power Supply | DC 9 V / 300 mA |
| Interface | RS232 serial output |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| Data Storage | 900 sets with timestamp, temperature, ATC/MTC status, and measurement mode |
| Brand | SANXIN Peri |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | PC5 |
| Pricing | Upon Request |
| Measurement Parameters | Single-Parameter (pH + Conductivity/TDS/Salinity/Resistivity) |
| Form Factor | Pen-Style Portable |
| Intended Use | Field & On-Site Applications |
| Conductivity Range | 0–2000 µS/cm |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | 0–50 °C |
| Accuracy | ±1% FS |
| Minimum Resolution | 0.001 µS/cm |
| pH Range | –2.00 to 16.00 pH |
| pH Accuracy | ±0.01 pH |
| Temperature Compensation | Automatic (0–50 °C) |
| Calibration | 1–3 Point Auto-Calibration (pH), Conductivity Auto-Calibration |
| Display | Dual-Color Backlit LCD with Auto-Off Setting |
| Power Source | AAA Batteries |
| Enclosure Rating | IP67 |
| Accessories Included | Rugged Carrying Case, Calibration Solutions (pH 4.01/7.00/10.01, 1413 µS/cm KCl), Sample Vials, Electrode Cap |
| Brand | SANXIN Peirui |
|---|---|
| Origin | Shanghai, China |
| Model | PG100 |
| Instrument Type | Multiparameter Process Controller |
| Measurement Accuracy | ±0.02 pH / ±2 mV |
| pH Range | 0.00–14.00 |
| ORP Range | −1999 to +1999 mV |
| pH Resolution | 0.01 pH |
| ORP Resolution | 1 mV |
| Calibration Solutions | NIST-traceable pH buffer standards (pH 4.00, 6.86, 9.18) |
| Input Signals | 0–5 V DC, 1–5 V DC, 0–10 mA DC, 4–20 mA DC |
| Output Signals | 0–10 V DC, 4–20 mA DC |
| Alarm Outputs | 2 independent relay outputs (configurable as high/low limit with adjustable hysteresis) |
| Control Output | 1 SPST switch output (ON/OFF, selectable direct/reverse action) |
| Power Supply | 90–260 V AC, 50/60 Hz |
| Operating Environment | 0–50 °C, 35–85 % RH (non-condensing) |
| Weight | 0.25 kg |
| Compliance | Designed for industrial process monitoring per IEC 61000-6-2 (EMC immunity) and IEC 61000-6-4 (EMC emissions) |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Model | PHB-3 |
| Instrument Type | Pen-style pH Meter |
| Measurement Range | 0.0–14.0 pH |
| Resolution | 0.1 pH |
| Accuracy | ±0.01 pH |
| Calibration | Single-point (pH 7.00) |
| Temperature Compensation | None |
| Power Supply | Two AAA batteries (1.5 V × 2) |
| Dimensions | 176 × 25 × 39 mm |
| Weight | 95 g |
| IP Rating | IP57 |
| Calibration Solution Compatibility | USA-standard pH buffers (e.g., pH 4.01, 7.00, 10.01) |