| Brand | SSI |
|---|---|
| Origin | USA |
| Model | SeriesIII |
| Pump Type | Isocratic (Single-Solvent) HPLC Pump |
| Construction | Stainless Steel Flow Path with Optional PEEK Fittings |
| Pressure Protection | Dual High/Low-Pressure Limit Shutdown |
| Control Interface | Front-Panel Keypad + LED Display + RS-232 Serial Port |
| Self-Cleaning Capability | Integrated Pump Head Flush Function + Quick-Release Drain Valve |
| Flow Path Design | Dual Check Valve Architecture |
| Seal Maintenance | Tool-Free Seal Ring Replacement |
| Operational Duty | Continuous Duty Rated for Stable Flow Delivery |
| Brand | SRS/Stanford Research Systems |
|---|---|
| Origin | USA |
| Model | DS345 |
| Frequency Range | 1 µHz to 30.2 MHz |
| Frequency Resolution | 1 µHz |
| Waveforms | Sine, Square, Ramp, Triangle, Noise |
| Modulation Types | AM, FM, Phase Modulation, Burst, Linear/Logarithmic Sweep |
| Arbitrary Waveform Memory | 16,300 points |
| Sample Rate | 40 MSa/s |
| Reference Input | 10 MHz |
| Optional Interfaces | RS-232, GPIB |
| Brand | SRS/Stanford Research Systems |
|---|---|
| Origin | USA |
| Model | RGA1-100amu, RGA1-200amu, RGA1-300amu |
| Mass Range | 1–100 amu / 1–200 amu / 1–300 amu |
| Resolution | <0.5 amu (FWHM) |
| Detection Limit | 5 × 10⁻¹⁴ Torr (with EM detector) |
| Sensitivity | 2 × 10⁻⁴ A/Torr (Faraday cup) |
| Dynamic Range | 6 decades |
| Response Time | 1–2 s |
| Detector Options | Faraday Cup (standard), Electron Multiplier (optional) |
| Operating Pressure Range | 10⁻⁴ Torr to UHV (FC) |
| Max. Probe Temperature | 70 °C |
| Max. Bakeout Temperature | 300 °C (probe only, ECU excluded) |
| Interface | RS-232 |
| Brand | Starna |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Starna Standard & Specialized Quartz Cuvettes |
| Price Range | USD 0 – 999 |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | 884 |
| Price Range | USD 14,000–28,000 |
| Key Measurement Modes | DPV, NPV, DCV, SWV, ACV (1st & 2nd), CV, PSA, CCPSA, CVS, CPVS |
| Potential Range | ±5 V |
| Max Output Potential | ±12 V |
| Max Output Current | ±80 mA |
| Scan Rate | 1 mV/s–3 V/s (1 mV resolution) |
| Current Measurement Range | 10 nA–10 mA (7 decades) |
| Electrode Support | Metrohm Multi-Mode Electrode (MME), Rotating Disk Electrodes (Au, Pt, GC, Ag, Graphite) |
| Interface | USB |
| Compliance | GLP-ready with user authentication, audit trail, electrode self-test, and automated calibration logging |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Origin Category | Domestic (China) |
| Model | InnoCon 60C |
| Detection Parameters | Conductivity, Salinity, TDS, Resistivity, Temperature |
| Portability | Benchtop |
| Intended Use | Laboratory |
| Conductivity Range | 0–5.000 / 50.00 / 500.0 / 5000 µS/cm |
| TDS Range | 0–500 ppt |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–325 ppt |
| Temperature Range | 5–55 °C |
| Accuracy | ±1% of Full Scale |
| Minimum Resolution | 0.001 / 0.01 / 0.1 / 1 µS/cm |
| Temperature Compensation | Automatic (adjustable TC coefficient: 0.00–9.99%, factory default 2.00%) |
| Data Storage | 100 measurement records |
| Power Supply | Rechargeable Li-ion battery with AC adapter |
| Interface | USB-B for PC connectivity |
| Display | Backlit LCD with adjustable brightness and keypress tone |
| Electrode Diagnostics | Real-time electrode status indication |
| Auto Power-Off | Configurable timeout (default: 10 min) |
| Calibration | Manual 1–3 point calibration with user-defined standards |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SDW-4334 |
| Price Range | USD 2,800 – 7,000 |
| Heating Capacity | 4 independent stations (500 W each) |
| Max Operating Temperature | 400 °C |
| Compliance | GB/T 4334–2020 (including optional Method A) |
| Control System | PLC + PID temperature regulation |
| Cooling | Integrated reflux condensation system with auto-recirculation |
| Safety Features | Low-coolant alarm, auto-shutdown, power-interruption resume function |
| Power Supply | 2000 W total |
| Optional Modules | ICT-W closed-loop chiller, ICT-M Wi-Fi remote monitoring, ICT-S SMS-based remote control, ICT-A sensitization test kit, acid fume extraction cabinet |
| Brand | StellarNet |
|---|---|
| Origin | USA |
| Model | Blue-Wave |
| Spectral Range | 280–900 nm |
| Detector Type | CCD |
| Optical Resolution | 0.75–6 nm (FWHM) |
| Sensitivity | 100 photons/count at 400 nm |
| Signal-to-Noise Ratio | 1000:1 (full well) |
| Dynamic Range | 2000:1 (6 decades) |
| Stray Light | 0.02% at 435 nm |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | CamScan1000 |
| Measurement Principle | Magnetic Barkhausen Noise (MBN) |
| Cycle Time | 6–8 seconds per lobe |
| Channel Configuration | Single- or Multi-channel |
| Detection Type | Non-destructive, quantitative surface burn assessment |
| Alarm Threshold | User-definable |
| Compliance | Designed for ISO/IEC 17025-aligned QA environments |
| Application Scope | In-line and off-line camshaft inspection |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | CrankScan200 |
| Detection Principle | Magnetic Barkhausen Noise (MBN) |
| Measurement Type | Non-Destructive, Surface & Near-Surface Integrity Assessment |
| Channel Configuration | Single- or Multi-Channel Probe Support |
| Probe Compatibility | Curved-Surface Optimized Sensors for Journal, Fillet, Flank, and Crankweb Geometry |
| Alarm Thresholding | User-Configurable Signal Amplitude & Statistical Deviation Limits |
| Compliance Framework | Supports ISO 28671 (Non-destructive testing — Magnetic Barkhausen noise testing — General principles), ASTM E3094 (Standard Guide for MBN Testing of Ferromagnetic Materials), and GLP/GMP-aligned data traceability |
| Brand | Stresstech Oy |
|---|---|
| Country of Origin | Finland |
| Model | G2 |
| Portability | Field-deployable, integrated water-cooled X-ray generator |
| Safety Compliance | EN 61000-6-4, EN 61000-6-2, IEC 61000-4-3, CE-marked for industrial use |
| Detector Type | High-resolution silicon strip detector (SSD) or CCD-based imaging detector (configurable) |
| X-ray Source | Microfocus tungsten anode tube, 30–50 kV adjustable, <100 µm focal spot |
| Measurement Method | Sin²ψ technique with automated ψ-tilt stage (±45° range) |
| Data Acquisition | Real-time diffraction pattern capture, peak fitting via pseudo-Voigt deconvolution |
| Software Platform | RoboScan™ v5.x with GLP-compliant audit trail and 21 CFR Part 11-ready user access control |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | GearScan |
| Measurement Principle | Barkhausen Noise Analysis (BNA) |
| Diameter Range | 5–2000 mm |
| Module Range | 1–70 |
| Measurement Time per Tooth | 2–30 s (dependent on geometry and surface condition) |
| Motion Control | Computer-controlled precision DC servo motor with linear-bearing-driven probe |
| Compliance | Designed for ISO 13302, ASTM E2964, and EN 10327-based residual stress and grinding burn assessment workflows |
| Software | RoboScan™ PC-based acquisition and analysis suite with audit trail, user access levels, and GLP/GMP-ready reporting |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | Rollscan 250 |
| Type | Non-Destructive Surface Integrity Analyzer |
| Measurement Principle | Magnetic Barkhausen Noise (MBN) Analysis |
| Compliance | ISO 28640, ASTM E3147 (under development), EN 10327 (applicable for grinding burn assessment) |
| Sensor Interface | Plug-and-play modular connector |
| Motion Control | Motorized X/Z linear axes + A/T rotational axes |
| Software Platform | EasyGear v5.x (Windows-based, FDA 21 CFR Part 11 compliant configuration available) |
| Data Output | ASCII, CSV, XML |
| Cabinet Integration | Integrated control cabinet with main isolator switch, LED status indicators, emergency stop, door interlock, and Ergotron-display mounting |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | XStress 3000 |
| Application | Residual stress measurement via X-ray diffraction (XRD) |
| Portability | Field-deployable, battery-optional operation |
| Power Requirement | Single AC source (100–240 V, 50/60 Hz) |
| Setup Time | ≤10 minutes |
| Communication Interface | Ethernet, USB, and embedded Windows-based controller |
| Compliance | Designed for ISO 21940, ASTM E915, and EN 15305-compliant residual stress evaluation |
| Brand | STT |
|---|---|
| Origin | Beijing, China |
| Manufacturer | STT Senfu Technology |
| Model | EQ-STT-5000 |
| Detection Limit | 0.1 ppb (benzene) |
| Weight | 2.2 kg |
| Dimensions | 267 × 197 × 308 mm |
| Column | Microfabricated GC column with 10.6 eV PID detector |
| Power | Built-in rechargeable battery (>9 h operation) |
| Carrier Gas | Ambient air (filtered via activated carbon + molecular sieve) |
| Measurement Range | 0.1–300 ppb or 50 ppb–10 ppm (benzene) |
| Accuracy | ±1% FS |
| Sample Matrices | Air, water (with optional headspace module), soil (with optional thermal desorption unit) |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SULFUVL |
| Pricing | Upon Request |
| Brand | SUNJUNE |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | VP-TA2 Pro |
| Price Range | USD 8,500 – 17,000 |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SUPEC 5220 |
| Instrument Type | Triple Quadrupole (QqQ) |
| Application Scope | General-Purpose LC-MS/MS Platform |
| Configuration | Integrated Online SPE-LC-MS/MS |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Instrument |
| Model | SUPEC 7000 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory-Based Analysis |
| Key Features | High-Temperature Gas Flow Control, Multi-Stage Gradient Vacuum System, High-Efficiency Ion Interface, Distributed Collision/Reaction Cell, Temperature- and Humidity-Stable Quadrupole Mass Analyzer |
| Compliance Context | Designed for GLP/GMP-aligned laboratories |
| Software Platform | EXPEC ICP-MS Control Suite v3.2 (with method validation templates, QC flagging, and raw data integrity logging) |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Model | SUPEC 7010 |
| Instrument Type | Quadrupole ICP-MS |
| Application Domain | Laboratory & Environmental Monitoring |
| Compliance | HJ 700–2014 |
| Automation Level | Fully Automated Sample Intake, Filtration, Pre-treatment, Analysis, QC, and Data Transmission |
| Detection Scope | Multi-element (As, Cd, Cr, Cu, Hg, Ni, Pb, Zn, etc.) in Surface Water, Groundwater, Drinking Water, and Seawater |
| Measurement Time per Sample | <5 min |
| Interference Resistance | High (immune to color, turbidity, matrix-induced polyatomic interferences via collision/reaction cell technology) |
| Environmental Profile | Low reagent consumption, no electrode wear, near-zero liquid waste generation |
| Regulatory Alignment | Designed for GLP-compliant operation |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Automation Level | Full End-to-End Sample-to-Result Automation |
| Sample Forms Supported | Solid and Liquid Matrices |
| Acid Compatibility | HNO₃, HCl, HF, HClO₄ |
| Volumetric Accuracy | <0.025 mL (5–50 mL range) |
| Sample Introduction | Integrated Auto-Sampling with In-Line Filtration |
| Safety Features | Auto-Ignition, Auto-Optimization, Auto-Quenching, Acid-Fume Extraction, Corrosion-Resistant Fluidic Pathways |
| Calibration & QC | Auto-Standard Curve Generation, Multi-Point QC Triggering (LOD, Blank, CRM), Adaptive Response Logic (Re-run / Skip / Abort) |
| Data Interface | Real-Time CPS/Concentration/RSD Dashboard, Interactive Calibration Plotting, Outlier Flagging |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SUPEC 7030 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory & Continuous Ambient Air Monitoring |
| Detection Mode | Online Automated ICP-MS Analysis with Integrated Sample Preparation |
| Brand | Supernova / EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | EXPEC 6500 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit | Not Specified |
| Precision (RSD) | <1% @ 8 h |
| Wavelength Range | 160–900 nm |
| Optical Resolution | Not Specified |
| RF Power Range | 500–1600 W (Digital Self-Excited Solid-State Generator) |
| Observation Mode | Dual-View Vertical Torch (Axial & Radial) |
| Detector | Custom Large-Area E-CCD |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GMA3500 |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1 / 0.2 / 0.4 / 0.7 / 1.0 / 2.0 nm (6-step auto-switching) |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Model | GMA3860 |
| Price Range | USD 42,000 – 56,000 |
| Compliance | GB/T 42027-2022, HJ 195-2023, HJ 200-2023, HJ/T 198-2005, HJ/T 197-2005, HJ 199-2023 |
| Light Source | Deuterium Lamp (with optional element lamps for Hg analysis) |
| Detector | CCD Diode Array |
| Key Features | Integrated UV digestion-dilution module for total nitrogen, on-line oxidation for ammonia-N, cold trap + auto-dehydration system, auto-rinsing during NO₃⁻/TN analysis, programmable dilution, optional autosampler (7- or 60-position) |
| Brand | SYSTEA |
|---|---|
| Origin | Italy |
| Model | EASYCHEM PLUS |
| Product Type | Discrete Analyzer |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 60 positions (18-sample carousel + auxiliary racks) |
| Reagent Positions | 18 |
| Flow Cell Path Length | 10 mm |
| Light Source | 6 V / 10 W Halogen Lamp with UV-Visible Spectral Output |
| Detection Principle | Photometric Colorimetry (Static Reaction in Flow-Through Cuvette) |
| Compliance | Designed for ASTM D129, ISO 6878, ISO 15681, USP <621>, EPA Methods 353.2, 365.2, 4500-NH₃ F, 4500-NO₂⁻ B, 4500-P E, and GLP/GMP-aligned workflows |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm |
| Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 176–2500 cm⁻¹ |
| Spectral Resolution | 10 cm⁻¹ |
| Minimum Wavenumber | 176 cm⁻¹ |
| Spectral Reproducibility | <1 cm⁻¹ |
| Laser Wavelength | 1064 nm |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TB-2 |
| Price Range | USD 140–700 (FOB) |
| Instrument Type | TLC Scanner Accessory |
| Wavelength Range | 190–700 nm (multi-band selectable) |
| Calibration Wavelengths | UV 254 nm, UV 365 nm, and White Light |
| Plate Size Capacity | 50 × 50 mm to 200 × 200 mm |
| Adjustability | Horizontal Leveling ±0.1°, Width Adjustment Range: 50–220 mm |
| Construction | Anodized Aluminum Frame with Tempered Glass Doors & Stainless Steel Shelves |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Line | DHS Series |
| Heating Method | Infrared |
| Max Capacity | 61 g / 100 g / 120 g |
| Readability | 0.1 mg / 0.001% (HR models), 1 mg / 0.01% |
| Display | Backlit LCD with 5-key interface |
| Temperature Range | 50–160 °C (DHS-16A), 50–200 °C (DHS-20A) |
| Temperature Increment | 1 °C (from 50 °C) |
| Heating Time Setting | 0–99 min (1-min steps) |
| Termination Modes | Auto (weight stability), Timed, Manual |
| Built-in Methods | 50 user-programmable protocols |
| Output Parameters | Initial mass (g), Residual mass (g), Moisture content (% w/w), Dry matter (%), Moisture loss (%), Regain (%), Wet basis moisture (%), Heating mode, Set temperature, Duration |
| Calibration | External weight calibration (100 g standard |
| Interface | RS232 |
| Compliance Support | IQ/OQ/PQ documentation templates available |
| Power Supply | 220 VAC (±15% / −10%), 50 Hz |
| Power Consumption | 400 W |
| Operating Environment | 5–40 °C, 25–85% RH (non-condensing) |
| Optimal | 15–30 °C, 50–75% RH (non-condensing) |
| Dimensions (W×D×H) | 510 × 353 × 333 mm |
| Weight | 8.9 kg |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Wavelength Dispersion Element | Holographic Grating |
| Slit Width (Spectral Bandpass) | 1.0–20.0 nm |
| Optical Resolution | 0.2 nm |
| Sensitivity | 1200:1 (RMS), 15,000:1 (RMS with Background Subtraction) |
| Wavelength Accuracy | ±2 nm |
| Excitation Source | Pulsed Xenon Arc Lamp |
| PMT Detection Range | Up to 900 nm |
| Maximum Scan Speed | 30,000 nm/min |
| Software | FL Analyst (English & Chinese GUI) |