| Brand | Thermo Fisher |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | UltiMate 3000 RSLC |
| Instrument Category | Rapid Separation Liquid Chromatography (RSLC) |
| Maximum Pressure | 1034 bar (15,000 psi) |
| Maximum Flow Rate | 8 mL/min |
| System Configurations | Binary, Quaternary, or Dual Triple-Quaternary Pump Options |
| Column Particle Size Compatibility | Down to 1.7 µm |
| Software Platform | Chromeleon CDS (Chromatography Data System) with Method Transfer & Development Tools |
| Fitting Technology | Viper™ fingertight fittings |
| Separation Speed Gain vs. Conventional HPLC | Up to 50× |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | UltiMate 3000 RSLCo |
| Instrument Type | Nano-LC System |
| Flow Range | 50 nL/min – 50 µL/min (nano to capillary/micro) |
| Auxiliary Microflow Pump | up to 2500 µL/min |
| Maximum Pressure | 860 bar |
| Technology | ProFlow™ Nanoflow Control, oViper™ Hand-Tight Fitting, Dual Gradient Architecture (High-Pressure Binary + Microflow Ternary) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | U3000 Standard Binary System |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Maximum Flow Rate | 8 mL/min |
| Maximum Backpressure | 100 MPa (15,000 psi / 1000 bar) |
| Column Temperature Range | 5–110 °C |
| Gradient Delay Volume | Adjustable via SpinFlow™ Technology |
| Autosampler Carryover | < 0.001% |
| Detector Compatibility | UV-Vis (DAD, MWD, VWD), Fluorescence, CAD, RID, MS |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | UltiMate 3000 Standard Dual LC System |
| Price Range | USD $25,000–$65,000 |
| Instrument Type | Multidimensional Liquid Chromatograph |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | UltiMate 3000 Standard Quaternary System |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Maximum Backpressure | 62 MPa (9000 psi / 620 bar) |
| Flow Rate Range | Up to 10 mL/min |
| Solvent Channels | 4 integrated with degasser (LPG-3400SD) |
| System Delay Volume | Matched to UltiMate 3000 RS Quaternary System |
| Detector Compatibility | UV-Vis (DAD, MWD, VWD), Fluorescence, CAD, RID, MS |
| Autosampler Options | WPS-3000TSL (thermostatted) or WPS-3000SL (non-thermostatted) |
| Column Compartment | TCC-3000SD with dual field-upgradable column switching valves |
| Software Platform | Chromeleon CDS v6.x and v7.x (including eWorkflow™, audit trail, 21 CFR Part 11 compliance modules) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | UltiMate 3000 Ti |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Maximum Flow Rate | 8 mL/min |
| Maximum Backpressure | 100 MPa (15000 psi / 1000 bar) |
| Column Oven Temperature Range | 5–110 °C |
| Autosampler Carryover | < 0.001% |
| Gradient Delay Volume | Adjustable via SpinFlow™ Technology |
| Flow Accuracy | ≤ 0.1% RSD (Dionex SmartFlow™) |
| Detector Compatibility | UV-Vis (DAD, MWD, VWD), Fluorescence, CAD, RID, MS |
| Software Platform | Chromeleon CDS v6.x and v7.x (including eWorkflow, 21 CFR Part 11 compliance modules) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | UHPLC+ |
| Instrument Type | Conventional HPLC with Full UHPLC Compatibility |
| Maximum System Pressure | 620 bar (Standard Analytical), 1000 bar (RSLC), 800 bar (RSLCo Column Rating) |
| Flow Rate Range | 20 nL/min – 10 mL/min |
| Data Acquisition Rate | Up to 100 Hz |
| Detector Options | UV-Vis, Fluorescence, Refractive Index, Corona CAD, Coulometric Electrochemical, MS (via DCMSLINK™) |
| Brand | Thermo Fisher |
|---|---|
| Model | Ultimate |
| Type | Nano-LC / Capillary LC System |
| Flow Range | 50 nL/min – 10 µL/min |
| Column Compatibility | 50–360 µm ID capillary & nano columns |
| Detection Interface | ESI-MS, nano-ESI source compatible |
| Regulatory Compliance | GLP-ready architecture, 21 CFR Part 11–ready software options |
| Pump Technology | Dual high-precision micro-piston pumps with active solvent compressibility compensation |
| Injector | FAMOS autosampler with <100 nL injection precision |
| UV Detection | Scanning diode array detector (DAD), optional nano-flow UV cell (Z- or U-path, 10–50 nL volume) |
| Temperature Control | Optional thermostatted column compartment (4–80 °C) |
| Software Platform | Chromeleon CDS (Chromatography Data System), supporting audit trail, electronic signatures, and method validation workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | UltiMate® 3000 ECD-3000RS |
| Detection Principle | Amperometric & Coulometric Electrochemical Detection |
| Instrument Type | Electrochemical Detector (ECD) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | UltiMate3000 |
| Price Range | USD 42,000 – 56,000 (FOB) |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Maximum Operating Pressure | 620 bar |
| Data Acquisition Rate | 100 Hz |
| Maximum Flow Rate | 10 mL/min |
| Pump Configuration Options | 7 single-pump and 5 dual-pump modular combinations |
| Dimensionality Support | 1D, 2D, and multi-dimensional LC workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | UltiMate3000-Ti |
| Instrument Type | Fast Liquid Chromatograph |
| Construction Material | Titanium pump heads, ceramic components, PEEK fluidic path |
| Brand | Thermo Fisher |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic HPLC System |
| Model | Vanquish Access HPLC System |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Application Scope | General-Purpose Analytical Use |
| Flow Rate Range | 0–10 mL/min |
| Maximum Operating Pressure | 500 bar |
| Injection Volume Range | Standard: 0.01–100 µL |
| Optional | 0.01–1000 µL |
| Pump Technology | Thermo Scientific SmartFlow™ |
| Workflow Automation | eWorkflow™ |
| Data System Integration | Compatible with Thermo Scientific Chromeleon™ CDS and other compliant Chromatography Data Systems (CDS) |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Vanquish Duo |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Configurations | Dual-Gradient LC, Tandem LC, LC-MS Coupling, Back-Flush Gradient LC |
| Software Platform | Thermo Scientific Chromeleon CDS (FDA 21 CFR Part 11 Compliant) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Vanquish Flex Quaternary UHPLC System |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | Dedicated Analytical Instrument |
| Maximum Pressure | 1000 bar (15,000 psi) |
| Flow Rate Range | Up to 8 mL/min |
| Solvent Channels | 4 (Quaternary Low-Pressure Gradient Mixing) |
| Injector Capacity | 208 injections (single vial) |
| Column Oven Temperature Range | 5–120 °C (dual-zone gas-heated & pressurized air system) |
| Detection Options | Diode Array Detector (DAD) with LightPipe™ technology, Fluorescence Detector (FLD), Electrospray Ionization Mass Spectrometry (ESI-MS) compatible interface |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Vanquish Neo UHPLC |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph |
| Application Scope | General-Purpose LC-MS Platform |
| Flow Rate Range | 100 nL/min–100 µL/min |
| Maximum Operating Pressure | 150 MPa |
| Flow Precision | ≤0.2% RSD or ≤0.1 µL/min SD (whichever is greater), validated per IQ protocol using Cytochrome C tryptic digest peptides (TGQAPGFSYTDANK) |
| Injection Volume Range | 100 nL–100 µL |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Vanquish |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Operating Pressure | 150 MPa (22,000 psi) |
| Sample Capacity | 8832 positions |
| Injection Volume Range | 0.01–100 µL |
| Column Oven Temperature Range | 5–120 °C |
| Data Acquisition Rate | 200 Hz |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Handheld Raman Spectrometer |
| Model | 1064Defender |
| Spectral Range | 200–2500 cm⁻¹ |
| Spectral Resolution | 8–13 cm⁻¹ |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Repeatability | ±0.1 cm⁻¹ |
| IP Rating | IP68 |
| Compliance | MIL-STD-810H |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 253 Plus |
| Instrument Type | Stable Gas-Source Isotope Ratio Mass Spectrometer |
| Key Technology | 10 kV IRMS Platform |
| Amplifier Resistance | 10¹³ Ω |
| Detector Configuration | Dual-Path, Semi-Mass Baseline Monitoring |
| Magnet Design | High-Stability Electromagnet with Optimized Pole Geometry |
| Workflow Integration | Built-in LIDI (Long Integration Dual-Inlet) Protocol |
| Sample Utilization Efficiency | Up to 3× Higher vs. MAT 253 |
| Minimum Sample Requirement | Reduced by up to 67% vs. MAT 253 |
| Signal-to-Noise Ratio | Enhanced for Low-Abundance Ions (e.g., m/z 47, 48, 49) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Accela |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Maximum Operating Pressure | 1250 bar (18,130 psi) |
| Flow Rate Range | 0.001–2.000 mL/min |
| Gradient Delay Volume | ≤70 µL |
| Flow Accuracy | ≤±0.5% |
| Gradient Accuracy | ≤±0.5% |
| Pressure Ripple | <0.5 bar (peak-to-peak) |
| Typical Peak Width (FWHM) | <1 s |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | ARGUS VI |
| Instrument Category | Stable Gas Isotope Ratio Mass Spectrometer |
| Measurement Precision | High Precision |
| Analyte Range | Noble Gases (He, Ne, Ar, Kr, Xe) |
| Mass Range | Full Mass Range for Noble Gases (m/z 2–132) |
| Resolution | High Mass Resolution (M/ΔM > 300 at 10% valley) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ARL 9900 |
| Instrument Type | Floor-standing |
| X-ray Tube Power Options | 1.2 kW, 2.5 kW, 3.6 kW, 4.2 kW |
| Elemental Range | Be to U (with appropriate analyzing crystals) |
| Sample Introduction | 8-position, 12-position or 98-position autosampler |
| Weight | ~750 kg |
| Max. Power Consumption | 4.8 kVA |
| Configuration | Scanning-type WDXRF spectrometer with optional simultaneous XRD channel |
| Brand | Thermo Fisher |
|---|---|
| Origin | France |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Powder X-ray Diffractometer |
| Model | ARL EQUINOX 100 |
| Power Stability | < 0.0001 (unitless relative stability, typical for high-stability X-ray tube power supply) |
| Detector | Integrated EQUINOX curved position-sensitive detector (CPSD) |
| Cooling | Fully integrated internal water-cooling system |
| Sample Handling | Optional 6-position autosampler, transmission powder holders, thin-film accessories |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ARL EQUINOX Pro |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | 3000 W |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Floor-standing |
| Excitation Source | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 1000 mm |
| Grating Line Density | 1080, 1667, and 2160 lines/mm |
| Wavelength Range | 200–760 nm |
| Number of Analytical Channels | 80 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | ARL Optim’X |
| Instrument Type | Floor-standing |
| X-ray Tube Power | 50 W / 200 W (equivalent via UCCO™ technology) |
| Elemental Range | F to U (73 elements) |
| Analysis Mode | Simultaneous (fixed-channel) and Sequential (scanning) |
| Cooling | Air-cooled, no external water circulation required |
| Sample Handling | Standard 1-position manual loader |
| Software | Thermo Scientific OXSAS with OptiQuant™ quantitative package |
| Compliance | Designed to meet ASTM E1361, ISO 2936, ISO 8258, and GLP/GMP data integrity requirements (21 CFR Part 11-ready audit trail) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ARL PERFORM'X Sequential |
| Price Range | USD 135,000–205,000 (FOB) |
| Instrument Type | Sequential WDXRF |
| X-ray Tube Power | 1.5 kW (ARL PERFORM'X 1500W), 2.5 kW (ARL PERFORM'X 2500W), 4.2 kW (ARL PERFORM'X 4200W) |
| Elemental Range | F (Z=9) to U (Z=92), plus C (Z=6) |
| Detection Limit | Sub-ppm for most elements in optimized matrices |
| Angular Positioning Accuracy | ≤0.0005° (Moiré fringe encoder-based goniometer) |
| Sample Form | Solids (pressed pellets, fused beads), Liquids (sealed cells), Powders, Coatings |
| Automation | Integrated XYZ sample changer with up to 120-position capacity |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Thermo Scientific BioMate 3S |
| Optical Design | Double-Beam |
| Detector | Photodiode Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | <0.08% T |
| Automation | Automatic Wavelength Selection |
| Compliance | Meets pharmacopeial requirements (USP <857>, EP 2.2.25, JP 2.04) for routine quality control assays |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | ConFlo IV |
| Instrument Type | Continuous-Flow Interface for Stable Gas Isotope Ratio Mass Spectrometry |
| Measurement Precision | High-Precision Isotopic Ratio Detection |
| Reference Gas Compatibility | CO₂, N₂, CO, H₂, SO₂ (≥5 independent reference gas lines) |
| Automation Features | Auto-switching between external analyzers and working gases, real-time H₃⁺ factor monitoring and correction, fully automated gas dilution (1–100% range, extendable) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Stable Gas Isotope Ratio Analyzer |
| Model | Delta Ray |
| Measurement Targets | δ¹³C and δ¹⁸O in CO₂ |
| Precision | < 0.05‰ (1σ) for both δ¹³C and δ¹⁸O |
| Dynamic Range | 200 ppm to 100% CO₂ |
| Calibration Interface | Universal Reference Inlet (URI) with automated reference gas delivery and real-time calibration |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DELTA V Advantage |
| Instrument Type | Stable Gas-Source Isotope Ratio Mass Spectrometer |
| Measurement Precision | High Precision |
| Price Range | USD 260,000 – 390,000 (based on configuration and regional duties) |