| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i5 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 / 5.0 nm (selectable) |
| Stray Light | ≤0.03% T |
| A/D Resolution | 24-bit |
| Baseline Flatness | ±0.001 A |
| Photometric Accuracy | ±0.3% T |
| Photometric Repeatability | ±0.15% T |
| Drift | ≤0.001 A/h (at 500 nm) |
| Noise | ≤0.0005 A |
| Photometric Range | 0–200% T, –0.3 to 3 A, 0–9999 C |
| Wavelength Setting | Automatic |
| Scan Speed | High/Medium/Low (user-selectable) |
| Display | 320 × 240 LCD |
| Light Sources | Imported Deuterium & Tungsten Lamps |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 460 × 380 × 180 mm |
| Weight | 20 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i6 |
| Optical Design | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm at D₂ line (656.1 nm), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 / 5.0 nm (selectable) |
| Stray Light | ≤0.03% T |
| Photometric Accuracy | ±0.2% T |
| Photometric Repeatability | ±0.15% T |
| Baseline Flatness | ±0.001 A |
| Drift | ≤0.001 A/h at 500 nm |
| Noise Level | ≤0.0005 A |
| Photometric Range | 0–200% T, –4.0 to +4.0 A, 0–9999 C |
| Wavelength Setting | Automatic |
| Scan Speed | High/Medium/Low (3-step selectable) |
| A/D Resolution | 24-bit |
| Display | 320 × 240 LCD |
| Light Sources | Imported deuterium lamp & tungsten-halogen lamp |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 470 × 370 × 180 mm |
| Weight | 20 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i7 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm at 656.1 nm (D₂ line), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm (user-selectable) |
| Stray Light | ≤0.03% T |
| Photometric Accuracy | ±0.2% T |
| Photometric Repeatability | ±0.15% T |
| Baseline Flatness | ±0.001 A |
| Drift | ≤0.001 A/h at 500 nm |
| Noise | ≤0.0005 A |
| Photometric Range | 0–200% T, –4.0 to +4.0 A, 0–9999 C |
| Wavelength Setting | Automatic |
| Scan Speed | High/Medium/Low (3 modes) |
| A/D Resolution | 24-bit |
| Display | 320 × 240 LCD |
| Light Sources | Imported Tungsten and Deuterium Lamps |
| Detector Type | Imported Silicon Photodiode |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 470 × 370 × 180 mm |
| Weight | 20 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i8 |
| Optical System | Dual-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.03% T |
| Photometric Accuracy | ±0.2% T |
| Photometric Repeatability | ≤0.15% T |
| Baseline Flatness | ±0.001 A |
| Drift | ≤0.0004 A/h (at 500 nm) |
| Noise | ≤0.0005 A |
| Photometric Range | 0–200% T, –4.0 to +4.0 A, 0–9999 C |
| Wavelength Setting | Automatic |
| Scan Speed | High/Medium/Low selectable |
| Data Interface | USB |
| Display | 320 × 240 pixel LCD |
| Light Sources | Imported tungsten and deuterium lamps |
| Detector Type | Imported silicon photodiode |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 625 × 430 × 210 mm |
| Weight | 28 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i9 |
| Optical System | Dual-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm @ 656.1 nm (D₂ line), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm (motorized, user-selectable) |
| Stray Light | ≤0.03% T |
| Photometric Accuracy | ±0.2% T |
| Photometric Repeatability | ≤0.15% T |
| Baseline Flatness | ±0.001 A |
| Drift | ±0.0004 A/h @ 500 nm |
| Noise | ±0.0005 A |
| Photometric Range | 0–200% T, –4.0 to +4.0 A, 0–9999 C |
| Wavelength Setting | Automatic |
| Scan Speed | High/Medium/Low (3 modes) |
| Data Interface | USB |
| Display | 320 × 240 pixel LCD |
| Light Sources | Imported deuterium and tungsten lamps |
| Detector | Imported silicon photodiode |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 625 × 430 × 210 mm |
| Weight | 28 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K1100 |
| Instrument Type | Kjeldahl Nitrogen Analyzer |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–240 mg N |
| Sample Weight Capacity | ≤5 g (solid), ≤20 mL (liquid) |
| Repeatability | ≤0.5% RSD |
| Recovery Rate | ≥99.5% |
| Steam Generation Control | Adjustable flow with real-time distillate temperature monitoring |
| Distillation Time | Programmable |
| Titration Resolution | 1.0 µL/step |
| Cooling Water Consumption | 1.5 L/min |
| Data Storage Capacity | 1800 test records |
| Power Supply | 220 V AC ±10%, 50 Hz |
| Rated Power | 2 kW |
| Dimensions (L×W×H) | 455 mm × 391 mm × 730 mm |
| Net Weight | 38 kg |
| Compliance | GB, NY, HJ, Chinese Pharmacopoeia, AOAC Official Methods, ISO 8968 & ISO 5983 |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K1100 / K1100F |
| Nitrogen Range | 0.1–200 mg |
| Repeatability | ±0.5% |
| Sample Weight | ≤5 g (solid) / ≤20 mL (liquid) |
| Recovery Rate | ≥99.5% |
| Power Consumption | 2 kW |
| Dimensions (L×W×H) | 455 × 391 × 730 mm |
| Titration Resolution | 1.0 µL/step |
| Distillation Time | 5–10 min per sample |
| Data Storage Capacity | 1,000 (K1100) / 1,800 (K1100F) methods |
| Cooling Water Flow | 1.5 L/min |
| Operating Voltage | 220 VAC ±10%, 50 Hz |
| Net Weight | 38 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K1160 + K1124 |
| Instrument Type | Fully Automated Kjeldahl Nitrogen Analyzer |
| Nitrogen Determination Range | 0.1–240 mg N |
| Distillation Time | 2.8–3 min per sample |
| Repeatability (RSD) | ≤0.5% |
| Sample Weight Capacity | ≤5 g (solid), ≤20 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Titration Resolution | 0.2 / 0.4 / 1.0 µL/step (selectable) |
| Power Consumption | 2 kW |
| Dimensions (L×W×H) | 460 × 360 × 725 mm |
| Net Weight | 38 kg |
| K1124 Autosampler | 24-position, 300 mL digestion tube capacity, integrated CAN interface, 24 VDC, 40 W, 920 × 625 × 908 mm, 80 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K1160 / K1160 + K1124 |
| Nitrogen Range | 0.1–240 mg |
| Distillation Time | 5–10 min/sample |
| Repeatability | ≤0.5% RSD |
| Sample Weight | ≤5 g (solid) or ≤20 mL (liquid) |
| Recovery Rate | ≥99.5% |
| Titration Resolution | 0.2, 0.4, or 1.0 µL/step (selectable) |
| Cooling Water Consumption | 0.5 L/min (at 15 °C inlet) |
| Power | 2 kW (K1160) |
| Dimensions (K1160) | 460 × 360 × 725 mm |
| Dimensions (K1124) | 920 × 625 × 908 mm |
| Net Weight (K1160) | 38 kg |
| Net Weight (K1124) | 80 kg |
| Data Storage | 1 million records (local), unlimited (cloud) |
| Compliance | FDA 21 CFR Part 11, GMP-aligned audit trail |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K9840 |
| Nitrogen Determination Range | 0.1–240 mg N |
| Distillation Time | 0–60 min |
| Repeatability | ±0.5% |
| Sample Weight Capacity | ≤6 g (solid) / ≤16 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 1.3 kW |
| Dimensions (L×W×H) | 400 × 385 × 735 mm |
| Net Weight | 30 kg |
| Compliance | GB, NY, HJ, Chinese Pharmacopoeia, AOAC Official Methods, ISO 8968 & ISO 5983 |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K9860 |
| Nitrogen Determination Range | 0.1 mg – 200 mg |
| Distillation Time | 5–10 min per sample |
| Repeatability | ±0.5% RSD |
| Sample Weight Capacity | ≤5 g (solid), ≤20 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 2 kW |
| Dimensions (L×W×H) | 455 mm × 391 mm × 730 mm |
| Touchscreen | 5.6-inch color LCD |
| Titration Resolution | 2.0 µL/step |
| Cooling Water Flow | 1.5 L/min |
| Data Storage | 1000 methods/results |
| Voltage | 220 VAC ±10%, 50 Hz |
| Net Weight | 38 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | N110 |
| Instrument Type | Portable NIR Spectrometer |
| Principle | MEMS-based Micro-Grating Monochromator with Array Detector |
| Wavelength Range | 640–1050 nm (Reflectance), 340–750 nm (Transmittance) |
| Optical Resolution | ≤20 nm (Reflectance), ≤14 nm (Transmittance) |
| Wavelength Repeatability | ±0.5 nm |
| Noise Level | ≤60 µAU |
| Signal-to-Noise Ratio | ≥7500 |
| Operating Temperature | 5–40 °C |
| Relative Humidity | <85% RH (recommended <75% RH) |
| Dimensions (L×W×H) | 179 × 126.5 × 52.6 mm |
| Weight | 215 g |
| Power Supply | DC 5 V / 1000 mA |
| Tungsten Lamp Current | 400 mA × 2 |
| Sampling Modes | Reflectance Ratio, Transmittance |
| Data Acquisition Interval | Configurable via Hanir Software |
| Scan Speed | Up to 10 spectra/sec (typical, dependent on integration time) |
| Software Platform | Android-based Hanir v3.x with GLP-compliant audit trail logging |
| Chemometrics Engine | Integrated MEMS-optimized PLS and PCA algorithms |
| Compliance | Supports ASTM E1655, ISO 12099, and USP <857> spectral data handling conventions |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | N500 |
| Instrument Type | Portable |
| Principle | Micro-Electro-Mechanical Systems (MEMS)-based Fabry–Pérot Interferometer (FPI) |
| Wavelength Range | 1750–2150 nm (extendable to 2450 nm) |
| Detector | InGaAs |
| Wavelength Resolution (FWHM) | ≤20 nm (≤1% of operating wavelength) |
| Wavelength Accuracy | ±1 nm |
| Signal-to-Noise Ratio (SNR) | ≥3000 |
| Sample Measurement Time | <30 s |
| Light Source Lifetime | 5000 h |
| Measurement Mode | Diffuse Reflectance |
| Dimensions (L×W×H) | 395 × 280 × 215 mm |
| Weight | 5.5 kg |
| Included Computing Platform | Microsoft Surface tablet |
| Software | MEMS Chemometrics Suite |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | N500 |
| Instrument Type | Portable |
| Measurement Principle | MEMS-based Micro-FPI (Fabry–Pérot Interferometer) |
| Wavelength Range | 1750–2150 nm |
| Sampling Mode | Diffuse Reflectance |
| Detector Type | InGaAs |
| Spectral Resolution (FWHM) | ≤20 nm (≤1% of center wavelength) |
| Wavelength Accuracy | ±1 nm |
| Signal-to-Noise Ratio (SNR) | ≥3000 |
| Measurement Time per Sample | <30 s |
| Light Source Lifetime | 5000 h |
| Dimensions (L×W×H) | 395 × 280 × 215 mm |
| Weight | 5.5 kg |
| Integrated Computing Platform | Microsoft Surface Tablet |
| Software Suite | MEMS Chemometrics Platform (Model Management, Quantitative Analysis, Audit Trail, User Permissions) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | N550 |
| Instrument Type | Laboratory NIR Spectrometer |
| Principle | MEMS Micro-Electro-Mechanical Systems Spectral Modulation |
| Wavelength Range | 900–1700 nm |
| Detector | Thermoelectrically Cooled InGaAs Array (256 pixels) |
| Slit Width | 50 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Signal-to-Noise Ratio | ≥3000 |
| Measurement Time per Sample | <30 s |
| Sampling Mode | Diffuse Reflectance |
| Sample Holders | 10 cm wide-mouth cup & 3 cm powder cup |
| Dimensions (L×W×H) | 450 × 280 × 228 mm |
| Weight | 15 kg |
| Compliance | ASTM E1655, ISO 12099, USP <857>, GLP/GMP-ready software architecture |
| Chemometrics Software | MEMS Quantitative Analysis Suite |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | N70 |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform Interferometry |
| Wavenumber Range | 3750–12500 cm⁻¹ |
| Scan Speed | <1 s (at 8 cm⁻¹ resolution) |
| Data Sampling Intervals | 2, 4, 8, or 16 cm⁻¹ |
| Measurement Modes | Integrating Sphere Diffuse Reflectance / Transflectance |
| Chemometrics Software | PLSQ — Partial Least Squares Spectral Modeling System |
| Detector | TEC-cooled InGaAs (2-stage thermoelectric cooling) |
| Resolution | <2 cm⁻¹ @ 7306.74 cm⁻¹ |
| Wavenumber Accuracy | <0.1 cm⁻¹ @ 7306.74 cm⁻¹ |
| Wavenumber Reproducibility | <0.04 cm⁻¹ @ 7306.74 cm⁻¹ |
| Inter-instrument Wavenumber Reproducibility | <0.05 cm⁻¹ @ 7306.74 cm⁻¹ |
| Absorbance Precision | ±0.1% T |
| Sample Measurement Time | <30 s |
| Dimensions | 445 × 237 × 320 mm |
| Weight | 20 kg |
| Power Consumption | 60 W |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T860 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | mV: −2000.0 to +2000.0 mV |
| pH | −20.000 to +20.000 pH |
| Temperature | −5 to 120 °C |
| Meter Accuracy | ±0.1 mV, ±0.003 pH, ±0.1 °C |
| High-Resolution Mode (Optional) | 0.05 mV, 0.0001 pH |
| Meter Resolution | 0.1 mV, 0.001 pH, 0.1 °C |
| Titration Accuracy | ±0.2% |
| Titration Resolution | 1/48,000 |
| Burette Options | Standard 10 mL |
| Burette Refill Time | 16 s (at 100% fill rate) |
| Stirring Method | Magnetic stirring |
| Electrode Interfaces | mV/pH input, reference electrode input, PT1000 temperature probe input |
| Communication Ports | 2× USB, RS232, power interface |
| Data Storage | 4 GB internal flash memory with multi-level search capability |
| User Management | Four-tier permission system with customizable access rights, electronic signature support, audit-trail-enabled data integrity controls, password policy enforcement (complexity, aging, expiration) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T860 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | ±1,999 mV / 0.00–14.00 pH |
| Potentiometric Accuracy | ±0.2 mV / ±0.02 pH |
| Resolution | 0.1 mV / 0.01 pH |
| Titration Repeatability | ≤0.2% |
| Temperature Measurement Range | 0–100 °C (PT1000) |
| Resolution | 0.1 °C |
| Max Error | ±0.2 °C |
| Burette Capacities | 15 mL (±0.025 mL tolerance), 25 mL (±0.035 mL tolerance) |
| Display | 7-inch color TFT touchscreen |
| Power Supply | 110–240 V AC, 50/60 Hz |
| Weight | 10 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T910 |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-purpose |
| Measurement Range | 0–300 mg KOH/100 g dry matter |
| mV Range | −2000.0 to +2000.0 mV |
| pH Range | −20.000 to +20.000 pH |
| Electrode Readout Accuracy | RSD ≤ 0.3% |
| Resolution | 0.01 mg KOH/100 g dry matter |
| Titration Resolution | 1/1,500,000 |
| Temperature Range | −5 to 120 °C |
| Temp. Accuracy | ±0.1 °C |
| Titration Tube Options | 1 mL / 5 mL / 10 mL / 25 mL |
| Refill Time (100% fill) | 16 s |
| Communication Interfaces | Dual USB, RS-232, Ethernet, CAN bus |
| Electrode Ports | mV/pH input, reference electrode port, PT1000 temperature probe port |
| Audit Trail | FDA 21 CFR Part 11 compliant |
| Electronic Signature | Supported |
| Data Integrity | Immutable export with checksum verification |
| User Management | Role-based, multi-level permissions |
| Sample Handling | Standalone station or optional auto-samplers (16×100 mL, 12×250 mL, 18×50 mL) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T930 |
| Titration Method | Fully Automated Volumetric Karl Fischer |
| Moisture Range | 0.001–100% (recommended: 0.1–100%) |
| Polarization Current Range | 1–24 µA |
| Polarization Current Resolution | 0.01 µA |
| Polarization Current Accuracy | ±0.05 µA |
| Voltage Range | 0–1999 mV |
| Voltage Resolution | 0.1 mV |
| Voltage Accuracy | ±0.2 mV |
| Titration Control Precision | 1/1,500,000 |
| Minimum Dispense Volume | 0.0001 mL |
| Standard Burette Capacity | 5 mL (optional: 1 mL or 10 mL) |
| Burette Accuracy | ±0.01 mL (1 mL), ±0.01 mL (5 mL), ±0.02 mL (10 mL) |
| Drift Resolution | 0.1 µg/min |
| Dynamic Delivery Rate | 0.02 µL/s to 0.1 mL/s (auto-switching) |
| Sample Cell Volume | 120 mL |
| Stirring | Integrated Magnetic Stirrer (manual/automatic modes) |
| Display | 10-inch capacitive TFT touchscreen |
| Data Storage | 8 GB internal flash memory |
| Export Formats | Excel, PDF |
| Communication Interfaces | Wi-Fi, USB, RS-232, BNC |
| Power Input | 100–240 V AC ±10%, 50–60 Hz |
| Compliance | FDA 21 CFR Part 11 (audit trail, role-based access control, electronic signatures) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T931 |
| Titration Method | Fully Automatic Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Moisture Measurement Range | 10 µg H₂O to 200 mg H₂O |
| Water Content Range | 0.0001%–100% (w/w) |
| Measurement Resolution | 0.001 µg H₂O (0.093 µg H₂O detection limit) |
| Current Resolution | 0.01 µA |
| Polarization Current Range | 1–24 µA |
| Polarization Current Accuracy | ±0.05 µA |
| Voltage Range | 0–1999 mV |
| Voltage Resolution | 0.1 mV |
| Voltage Accuracy | ±0.2 mV |
| Electrolysis Current Options | 1, 2, 5, 10, 20, 50, 100, 200, 400 mA |
| Max. Electrolysis Rate | 37.34 µg H₂O/s (2240 µg H₂O/min) |
| Titration Control Precision | 1/1,500,000 |
| Minimum Dispense Volume | 0.001 mL |
| Power Input | 100–240 V AC ±10%, 50–60 Hz |
| Output Voltage | 24 V DC |
| Data Storage | 8 GB internal flash memory |
| Display | 10-inch capacitive TFT touchscreen (Android-based UI) |
| Compliance | FDA 21 CFR Part 11, audit trail, four-tier user permission system, electronic signature, data integrity controls |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T960 |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-purpose |
| mV Measurement Range | −2000.0 mV to +2000.0 mV |
| mV Resolution & Accuracy | 0.1 mV resolution, ±0.1 mV ± 0.03% accuracy |
| pH Measurement Range | −20.000 to +20.000 pH |
| pH Resolution & Accuracy | 0.001 pH resolution, ±0.003 pH accuracy |
| Temperature Measurement Range | −5 °C to 120 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Burette Resolution | 1/1,500,000 |
| Burette Volume Options | 1 mL / 5 mL / 10 mL / 25 mL |
| Auxiliary Reagent Channels | Up to 4+4 (8-channel synchronized dosing) |
| Electrode Interfaces | mV/pH, reference, PT1000 temperature, optional polarographic |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T960 |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-purpose |
| mV Measurement Range | −2000.0 to +2000.0 mV |
| mV Resolution & Accuracy | 0.1 mV |
| pH Measurement Range | −20.000 to +20.000 pH |
| pH Resolution | 0.001 pH |
| pH Accuracy | ±0.003 pH |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±0.1 °C |
| Titration Tube Options | 5 mL / 10 mL / 25 mL |
| Maximum Simultaneous Dosing Channels | 4 (expandable to 6) |
| Titration Tube Resolution | 1/48,000 steps |
| Refill Time (100% fill) | 16 s |
| Electrode Interfaces | pH/mV input, reference electrode port, PT1000 temperature probe port |
| Communication Interfaces | Dual USB, RS-232, Ethernet |
| Cloud Connectivity | Yes (secure, role-based, audit-ready) |
| Brand | Haoyuan |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | DS-21L |
| X-ray Tube Power | 3000 W |
| 2θ Angular Range | 105°–170° (continuously adjustable) |
| ψ Angular Range | −57° to +57° |
| Available Anode Target Materials | Cr, Cu, Mn, Ti, Co, V, Fe |
| Minimum Focal Spot Size | 0.1 mm |
| Detector Configuration | Dual Linear Semiconductor Array Detectors |
| Individual Detector 2θ Coverage | 35° |
| Detector Linear Count Rate | >10⁹ CPS |
| Positioning System | Integrated Laser Displacement Sensor + Motorized Z-axis (600 mm travel) + Manual/Automatic XYZΦ Sample Stage (X: 300 mm, Y: 200 mm, Φ: 0–360°) |
| Measurement Methods | Sin²ψ (both side-inclination and co-inclination modes) |
| Residual Stress Repeatability (Fe powder reference) | < ±5 MPa (n = 5) |
| Radiation Shielding | Fully Enclosed Lead-Glass Enclosure Compliant with ANSI N43.2 |
| Standards Compliance | ASTM E915-2010, EN 15305:2008, GB/T 7704–2016 |
| Optional Target Materials | Cr, Mn, Cu, Co, Fe, V |
| Brand | Haoyuan |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DS-21P |
| X-ray Tube Power | 300 W |
| 2θ Angular Range | 105°–170° (continuously adjustable) |
| ψ Angular Range | −45° to +45° |
| Available Anode Target Materials | Cr, Cu, Mn, Ti, Co, V, Fe |
| Brand | Haoyuan |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DS-23MINI |
| X-ray Tube Power | 50 W |
| 2θ Angular Range | 140°–170° (continuously adjustable) |
| ψ Angular Range | −35° to +35° |
| Target Materials | Cr, Cu, Mn, Ti, Co, V, Fe |
| Detector | Dual semiconductor linear array (256 × 256 pixels), linear count rate > 10⁹ cps |
| Stress Measurement Repeatability (Fe powder) | < ±5 MPa (n = 5) |
| Compliance | ASTM E915-2010, EN 15305-2008, GB/T 7704-2017 |
| Brand | Haoyuan |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | DST-17 |
| X-ray Tube Power | 3000 W |
| 2θ Angular Range | 45°–170° (continuously adjustable) |
| ψ Angular Range | −25° to +50° |
| Target Materials | Cr, Cu, Mn, Ti, Co, V, Fe |
| Angular Resolution (2θ) | 0.0001° |
| 2θ Repeatability | < 0.003° |
| Stress Measurement Accuracy | ±5 MPa |
| Detector | High-resolution Silicon Drift Detector (SDD), linear array configuration |
| Sample Positioning | Laser displacement sensor with < 3 µm repeatability |
| Motion System | 4-axis motorized sample stage + 360° precision rotation stage |
| Radiation Shielding | Fully enclosed lead-glass enclosure compliant with ANSI N43.2 |
| Standards Compliance | ASTM E915-2010, EN 15305-2008, GB/T 7704-2016, ISO 9001 |
| Brand | Haoyuan |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DX-2700BH |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Floor-standing |
| X-ray Generator Power | 3 kW |
| Angular Accuracy | ±0.0001° |
| Resolution (FWHM) | SiO₂ ≤ 60% |
| Brand | Haoyuan |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DX-27mini |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Benchtop |
| Power Rating | 600 W (40 kV / 15 mA) or 1200 W (40 kV / 30 mA) |
| Angular Accuracy | 0.0001° |
| Resolution (FWHM) | SiO₂ ≤ 60% |
| X-ray Source | Metal-ceramic Cu-target tube, focal spot 1 × 10 mm |
| Goniometer Geometry | Horizontal θ–θ (sample-and-detector movement) |
| Radius of Diffraction Circle | 150 mm |
| Scan Modes | Continuous and Step Scanning |
| Angular Range (θs/θd coupled) | –3° to 150° |
| Minimum Step Size | 0.0001° |
| Angular Reproducibility | ±0.0005° |
| Angular Positioning Speed | 1500°/min |
| Detector Options | Sealed proportional counter or high-speed 1D semiconductor array |
| Energy Resolution | <25% (at Mn Kα) |
| Linear Count Rate | ≥5 × 10⁵ cps (proportional), ≥9 × 10⁷ cps (1D semiconductor) |
| Radiation Shielding | Lead + lead-glass enclosure |
| Overall System Stability | ≤1% RSD over 8 h |
| Sample Capacity | 6-position automated sample changer |
| Dimensions (W × D × H) | 600 × 410 × 670 mm |
| Cooling | Air or water (≥2.5 L/min) |
| Software Platform | Windows 7-based instrument control and data analysis suite |
| Brand | Haoyuan |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Floor-Standing |
| Angular Resolution | 0.001° |
| Angular Accuracy | ±0.0001° |
| Peak Resolution (FWHM) | SiO₂ ≤ 60% |
| Detector | High-Performance Semiconductor Array Detector |
| X-ray Source | Stabilized Cu Kα Sealed-Tube Source |