Chemical Analysis Instruments
Filter
Showing 511–540 of 4337 results
| Brand | Amptek |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OEM System Package |
| Pricing | Upon Request |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | OEM Solution |
| Form Factor | Benchtop / Portable |
| Industry Focus | Electronics |
| Elemental Range | Na (11) – U (92) |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV FWHM at Mn Kα |
| Repeatability | ≤0.1% RSD |
| Detector Type | X-ray Detector (Si-PIN, SDD, or CdTe) |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Model | PA-210/PA-230 |
| Power Supply Requirements | +5 VDC @ 15 mA, −5 VDC @ 15 mA |
| HV Input Range | +100 to +200 V (Si-PIN), −90 to −260 V (SDD/CdTe) |
| TEC Drive | +3.5 VDC @ 350 mA |
| Temperature Monitoring | 160 µA-biased silicon diode output |
| Signal Output | Negative pulse (Si-PIN), Positive pulse (SDD/CdTe) |
| Connector | 10-pin micro-DIN (1.0 mm pitch) |
| Thermal Control Capability | Closed-loop stabilization down to 230 K (−43 °C) |
| Compliance | Designed for integration into ISO/IEC 17025-compliant XRF, XRD, and EDX systems |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Model | PA-210/PA-230 |
| Power Supply Requirements | +5 VDC / −5 VDC (±50 mV ripple, 15 mA each) |
| HV Input Range | +100 to +200 V (Si-PIN), −90 to −260 V (SDD/CdTe) |
| TEC Drive | 3.5 V / 350 mA (max), <0.1 Vpp noise |
| Temperature Sensing | 160 µA-biased diode output (calibrated to 230 K minimum operating point) |
| Connector | 10-pin micro coaxial (0.025" pitch) |
| Mechanical Form Factors | Cylindrical (PA-210, Ø18 mm × 40 mm) and Flexible PCB-mount (PA-230) |
| Compliance | Designed for OEM integration into ISO/IEC 17025-compliant XRF, XRD, and EDX systems |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Model | XRT-450 |
| Target Anode | Ag (customizable) |
| Window | Be, 125 µm |
| Focal Spot Size | <150 µm FWHM |
| Beam Divergence | 120° |
| Operating Voltage | 5–50 kV |
| Max Tube Current | 250 µA |
| Max Output Power | 6 W |
| Input Voltage | 20 VDC |
| HV Polarity | Anode Grounded |
| Cooling | Conduction or Convection |
| Mounting | Threaded Nozzle |
| Weight | 400 g |
| Operating Temperature | –10 °C to +50 °C |
| Radiation Shielding Compliance | IEC 62495 |
| RoHS Compliance | RoHS3 |
| Warranty | 2 years or 4000 operating hours |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Model | X-123 |
| Form Factor | Benchtop/Portable |
| Element Range | Na (11) – U (92) |
| Detection Limit | 1 ppm – 99.99% |
| Energy Resolution | 139–260 eV @ 5.9 keV |
| Repeatability | 0.1% |
| Detector | Si-PIN with Two-Stage Thermoelectric Cooling |
| Effective Area | 6–25 mm² |
| Thickness | 500 µm |
| Be Window | 12.5–25 µm |
| Operating Temperature Range | −30 °C to +80 °C |
| Power Consumption | 2.5 W (5 VDC, 300–800 mA) |
| Weight | 180 g |
| Dimensions | 70 × 100 × 25 mm |
| Interface | USB 2.0 (12 Mbps), RS-232 (115.2 kbps), Ethernet (10BASE-T) |
| Compliance | RoHS-compliant, UL 61010-1:2009, CAN/CSA-C22.2 No. 61010-1, TÜV Certified (CU 72101153 01) |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Model | X-123 |
| Detector Type | Si-PIN |
| Active Area | 6–25 mm² |
| Thickness | 300–500 µm |
| Energy Range | 1.5–40 keV |
| Resolution (FWHM @ 5.9 keV) | 145–230 eV |
| Max Count Rate | 2 × 10⁶ cps |
| Power Consumption | 2.5 W (typ.) |
| Dimensions | 70 × 100 × 25 mm |
| Weight | 180 g |
| Cooling | Two-stage thermoelectric (ΔT ≤ 85 °C) |
| Interface | USB 2.0, RS-232, Ethernet (10BASE-T) |
| Compliance | RoHS, UL 61010-1:2009, CAN/CSA C22.2 No. 61010-1 |
| Brand | AMPTEK |
|---|---|
| Origin | USA |
| Model | X-123 FAST SDD C-Series Window |
| Detector Type | Silicon Drift Detector (SDD) with Si₃N₄/Al Thin-Film Window |
| Application Context | Low-Energy X-ray Detection (down to ~100 eV), Vacuum-Compatible & Ambient-Pressure Configurations |
| Compliance | ASTM E1598, ISO 21434 (X-ray instrumentation framework), Compatible with IEC 61000-4 Electromagnetic Immunity Standards |
| Software Interface | USB 2.0 / Ethernet |
| Brand | AMPTEK |
|---|---|
| Origin | USA |
| Model | X-123 FAST SDD C2 Window |
| Detector Type | Silicon Drift Detector (SDD) |
| Window Material | Ultra-thin Si₃N₄ (C2 series) |
| Elemental Detection Range | C (4.9 keV) to U (98 keV) |
| Energy Resolution | ≤125 eV at Mn Kα (5.9 keV), typical |
| Count Rate Capability | Up to 10⁶ counts/second |
| Vacuum Compatibility | Yes, integrated vacuum interface |
| Standard Interface | USB 2.0 and digital pulse processing |
| Compliance | CE, RoHS, FCC Class A |
| Brand | AMPTEK |
|---|---|
| Origin | USA |
| Model | X-123FAST SDD (70 mm²) |
| Resolution | 123 eV FWHM @ 5.9 keV |
| Max Count Rate | >1,000,000 cps |
| Peak-to-Background Ratio | 26,000:1 |
| Window Options | 0.5-mil Be or Si₃N₄ (C2) |
| Cooling ΔT | >85 K |
| Preamplifier Output Pulse Width | <60 ns |
| Active Si Thickness | 500 µm |
| Collimated Effective Area | 50 mm² |
| Total Sensitive Area | 70 mm² |
| Brand | AMPTEK |
|---|---|
| Origin | USA |
| Model | X-123FAST SDD (70 mm²) |
| Element Range | C (Z=6) to U (Z=92) with C₂ window |
| Detection Limit | 1 ppm – 99.99% |
| Energy Resolution | 123 eV FWHM at 5.9 keV |
| Count Rate Capability | >1,000,000 cps |
| Peak-to-Background Ratio | 26,000:1 |
| Window Options | 0.5-mil Be or C₂ (Si₃N₄) |
| Cooling ΔT | >85 K |
| Rise Time | <60 ns |
| Active Si Thickness | 500 µm |
| Collimated Effective Area | 50 mm² |
| Vacuum Compatibility | Yes |
| OEM Integration | Fully supported for XR100FAST, PX5, and X-123 platform configurations |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Model | XR-100CR |
| Detector Type | Si-PIN |
| Active Area | 6–25 mm² |
| Thickness | 300 or 500 µm |
| Be Window | 12.5 or 25 µm |
| Energy Resolution | 145–230 eV FWHM (@ 5.9 keV, ⁵⁵Fe) |
| Cooling | Two-stage thermoelectric (TEC), operating temp ≈ −55 °C |
| Power Consumption | <1 W |
| Housing | TO-8 hermetic package |
| Compliance | UL 61010-1:2004, CAN/CSA-C22.2 No. 61010-1:2004, TUV Certified (CU 72072412 01) |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | XR-100CR |
| Pricing | Upon Request |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Model | XR-100FastSDD-70 |
| Active Area | 70 mm² (effective to 50 mm²) |
| Energy Resolution | 123 eV FWHM @ 5.9 keV |
| Max Count Rate | >2,000,000 cps |
| Peak-to-Background Ratio | >26,000:1 |
| Window Options | Be (12.5 µm) or Si₃N₄ (C₂) |
| Detector Thickness | 500 µm |
| Cooling ΔT | >85 K |
| Preamplifier Rise Time | <60 ns |
| Package | TO-8 |
| Certifications | UL 61010-1:2009, CAN/CSA C22.2 No. 61010-1, TUV CU 72101153 01 |
| Brand | Amptek |
|---|---|
| Model | XR-100SDD |
| Detector Type | Silicon Drift Detector (SDD) |
| Active Area | 25 mm² |
| Silicon Thickness | 500 µm |
| Energy Resolution @ 5.9 keV (⁵⁵Fe) | 125–140 eV FWHM |
| Max Count Rate | 500,000 cps |
| Peak-to-Background Ratio | 8200:1 |
| Be Window Thickness | 12.5 µm |
| Operating Temperature | 0°C to +50°C |
| Power Consumption | <1 W |
| Weight | 125 g |
| Dimensions | 7.6 × 4.4 × 2.9 cm |
| Warranty | 1 year |
| Typical Lifetime | 5–10 years |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Model | XR-100SDD |
| Detector Type | Silicon Drift Detector (SDD) |
| Active Area | 25 mm² |
| Thickness | 500 µm |
| Energy Resolution | 125 eV FWHM @ 5.9 keV (11.2 µs peaking time) |
| Max Count Rate | 500,000 cps |
| Peak-to-Background Ratio | 20,000:1 (5.9 keV / 1 keV) |
| Be Window Thickness | 12.5 µm (0.5 mil) |
| Cooling Method | Two-stage thermoelectric (Peltier), no liquid nitrogen required |
| Operating Temperature | ~250 K (−23 °C) |
| Housing | TO-8 metal can |
| Compliance | UL 61010-1:2004, CAN/CSA-C22.2 No. 61010-1:2004, TUV Certified (CU 72072412 02) |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Model | XR-100SDD |
| Detector Type | Silicon Drift Detector (SDD) |
| Active Area | 25 mm² |
| Thickness | 500 µm |
| Energy Resolution | 125 eV FWHM @ 5.9 keV (11.2 µs peaking time) |
| Max Count Rate | 500,000 cps |
| Peak-to-Background Ratio | 20,000:1 (5.9 keV / 1 keV) |
| Be Window Thickness | 12.5 µm (0.5 mil) |
| Operating Temperature | ~250 K (−23 °C) |
| Cooling | Two-stage thermoelectric (Peltier), no liquid nitrogen required |
| Encapsulation | TO-8 metal can with vacuum-compatible Be window |
| Power Consumption | <1 W |
| Certifications | UL 61010-1:2004, CAN/CSA-C22.2 No. 61010-1:2004, TÜV Certificate #CU 72072412 02 |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Model | XRA-700 |
| Detector Channels | 7 |
| Cooling | Thermoelectric (Peltier) |
| Power Supply | Integrated regulated DC supply |
| Preamp | Low-noise charge-sensitive preamplifier per channel |
| Energy Range | 1 keV – 40 keV (dependent on detector configuration) |
| Compliance | RoHS, CE |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | OEM Solution |
| Pricing | Upon Request |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | FUTURA |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 200 positions / 5 racks |
| Reagent Positions | 104 or 360 |
| Flow Cell Path Length | 50 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Futura |
| Pricing | Upon Request |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | PROXIMA |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 104-position turntable autosampler (optional 360-position XYZ autosampler) |
| Reagent Positions | 36 |
| Flow Cell Path Length | 50 mm |
| Light Source | Tungsten-Halogen Lamp |
| Detection Limit | Sub-ppb level |
| Throughput | Up to 120 samples/hour |
| Pump Tubing | 52 channels (2 × 26) |
| Flow Rate Range | 50–3000 µL/min |
| A/D Resolution | 24-bit (1.68 × 10⁷) |
| Dimensions (Main Unit) | 75 × 50 × 42 cm |
| Weight (Main Unit) | 45 kg |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | PROXIMAs |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Volume | 0.5 mL |
| Reagent Positions | 104 |
| Flow Cell Path Length | 5–50 mm |
| Light Source | Halogen Lamp |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | SmartChem 200 |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Test | 300 µL |
| Sample Positions | 126 |
| Reagent Positions | 200 (including refrigerated slots) |
| Cuvette Path Length | 10 mm |
| Light Source | LED and Halogen Tungsten Lamp (6 V / 10 W, 2000 h lifetime) |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | SmartChem 450 |
| Sample Capacity | 100 positions (standard configuration) |
| Reagent Positions | 72 (with optional refrigeration) |
| Wavelength Range | 340–880 nm |
| Cuvette Path Length | 6 mm |
| Light Source | 6 V / 10 W halogen lamp |
| Throughput | up to 450 determinations per hour (including ISE module) |
| Absorbance Range | 0.001–4.200 Abs |
| Resolution | 0.0001 Abs |
| Temperature Control | 37 °C ± 0.3 °C |
| Dimensions | 500 × 700 × 1050 mm (H × W × L) |
| Weight | 48 kg |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | Smartchem 450 |
| Sample Throughput | Up to 450 samples/hour (colorimetric), 150 samples/hour (ISE) |
| Reaction Temperature Range | 30–50 °C (adjustable, ±0.1 °C accuracy) |
| Optical System | Dual-beam, dual-wavelength photometer with 12 filters (340–880 nm), 10 mm pathlength cuvettes |
| Absorbance Linearity | 0.001–4.200 Abs |
| Resolution | 0.0001 Abs |
| Minimum Reaction Volume | 180 μL |
| Sample Capacity | 100 positions (5 rotating racks) |
| Reagent Capacity | 72 positions (refrigerated at 10 °C) |
| Dispensing Precision | 0.1 μL (1.0–900 μL sample |
| Dilution Ratio | Up to 100× |
| Cuvette Disk | 80 reusable quartz/glass cuvettes |
| Compliance | US EPA Method 353.2 (with Cd-column module), ISO/IEC 17025-compatible operation |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | SmartChem 600 |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 200 positions |
| Reagent Positions | 100 |
| Cuvette Pathlength | 6 or 10 mm |
| Light Source | LED |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | Smartchem 600 |
| Product Type | Discrete Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Cup | 300 µL |
| Sample Capacity | 126 positions |
| Reagent Positions | 600 |
| Cuvette Path Length | 10 mm |
| Light Source | LED and Halogen Lamp |
| [Brand | AMS Alliance |
|---|---|
| Origin | USA |
| Model | Smartchem 600 |
| Sample Capacity | 200 positions |
| Reagent Positions | 100 (with refrigeration) |
| Wavelength Range | 340–1100 nm |
| Cuvette Path Length | 10 mm (6 mm optional) |
| Detection Principle | Dual-beam, dual-wavelength photometry |
| Maximum Throughput | 600 samples/hour |
| Reaction Disc Capacity | 85 reusable cuvettes |
| Temperature Control | 37 °C ± 0.3 °C |
| Linear Absorbance Range | 0.00001–4.2 Abs |
| Resolution | 0.00001 Abs |
| Minimum Reaction Volume | 180 µL |
| Compliance | ISO, AOAC, US EPA, AFNOR, COFRAC, BATF] |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | Smartchem140 |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 330–840 nm |
| Sample Capacity | 64 positions |
| Reagent Positions | 24 + 10 |
| Cuvette Path Length | 6 mm |
| Light Source | Halogen Lamp |