Chemical Analysis Instruments
Filter
Showing 421–450 of 10547 results
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | HLD MD30 |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | HLD MR15 |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | HLD MR30 |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | HLD PD03 |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | HLD PR02 |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | HP-5890 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | Ambient to 400 °C (oven), up to 400 °C (inlet) |
| Ramp Rate | 0.1–40 °C/min |
| Cool-Down Rate | 50 °C/min |
| Carrier Gas Flow Range & Control | 0–650 mL/min |
| Carrier Gas Pressure Range & Control | 0–8000 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 0–100 mL/min |
| Brand | Agilent |
|---|---|
| Origin | USA |
| Model | HP-5890 Series II |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Focus | Environmental Analysis |
| Detector Configuration | Dual FID (Flame Ionization Detector) |
| Injection System | Dual Capillary Inlet with Split/Splitless Mode |
| Software | Chinese-language GC Workstation |
| Column Included | One 30 m fused-silica capillary column |
| Regulatory Compliance | Designed for ASTM D1359, EPA Method 8020/8021, ISO 10378, and USP <621> applications |
| Temperature Control | Oven programmable from 35 °C to 400 °C |
| Ramp Rate | Up to 75 °C/min (typical) |
| Cool-down | Forced air cooling to ambient in <3.5 min (from 400 °C) |
| Carrier Gas Control | Electronic Pneumatic Control (EPC) for helium, hydrogen, or nitrogen |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Agilent HPLC-1220 Infinity II |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC-capable) |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 40 MPa (400 bar) |
| Sample Vial Capacity | 100 positions × 1.5 mL |
| Injection Volume Range | 1–50 µL |
| Column Oven Temperature Range | (Ambient −10 °C) to 60 °C |
| Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Agilent InfinityLab LC/MSD iQ |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Application Scope | General-Purpose LC/MS Analysis |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LC/MSD |
| Instrument Type | Single Quadrupole |
| Application Scope | General-Purpose |
| Mass Range | m/z 10–2000 |
| Scan Speed | 10,400 Da/s |
| Minimum SIM Dwell Time | 5 ms |
| Polarity Switching Time | < 300 ms |
| Ion Sources | ESI, APCI, Multi-Mode (ESI + APCI) |
| Dimensions (W × D × H) | 44.3 cm × 63.5 cm × 47.0 cm |
| Compatible Software | OpenLab CDS, OpenLab ChemStation, MassHunter WalkUp, MassWorks Software |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LC/MSD XT |
| Instrument Type | Single Quadrupole |
| Sensitivity | Sub-pg on-column detection limit (e.g., 500 fg injected for caffeine in ESI positive mode) |
| Ionization Sources | Electrospray Ionization (ESI), Atmospheric Pressure Chemical Ionization (APCI), Atmospheric Pressure Photoionization (APPI), Agilent Jet Stream (AJS) ESI/APCI, Dual-Mode Source |
| Mass Range | m/z 10–3000 |
| Scan Speed | Up to 10,000 Da/sec |
| Polarity Switching | < 200 ms |
| Software Platform | OpenLAB CDS (Chemical Workstation), compliant with FDA 21 CFR Part 11 and EU Annex 11 |
| Calibration Technology | MassWorks™ high-accuracy mass calibration (Cerno Bioscience integration) |
| Form Factor | Stackable module compatible with Agilent 1260/1290 Infinity II LC systems |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | InfinityLab Pro iQ / Pro iQ Plus |
| Instrument Type | Single-Quadrupole Mass Spectrometer |
| Application Scope | General-Purpose LC/MS Detection |
| Mass Range | m/z 2–1600 (Pro iQ) |
| Sensitivity | < 100 fg on-column (Pro iQ, ESI positive mode, reserpine) |
| Ion Sources | ESI, APCI, Dual ESI/APCI (MMI), AJS (Pro iQ Plus only) |
| Vacuum System | Agilent MS45 rotary vane pump |
| SIM Minimum Dwell Time | 1 ms |
| Polarity Switching Speed | < 15 ms |
| Dynamic Range | Up to 6 orders of magnitude (linear) |
| Dimensions (W × D × H) | 39.6 cm × 54.8 cm × 35.0 cm |
| Software Platform | OpenLab CDS (v2.8 FP2 and later), MassHunter WalkUp, MassWorks Oligonucleotide Analyzer, Deconvolution Accelerator for OpenLab CDS |
| Key Technologies | Cyclone Ion Guide, Hyperbolic Quadrupole Mass Analyzer, VacShield Vacuum Shield, SWARM Auto-Tuning, InfinityLab Assist Interactive Touch Interface |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | Intuvo 9000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Temperature Control Range | +10 °C above ambient to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cooling Performance | 450 °C to 50 °C in ≤3 min (ambient 22 °C) |
| Column Dimensions | Standard 0.18–0.53 mm ID capillaries |
| Detector Compatibility | FID, TCD, ECD, NPD, PID, and GC/MS interfaces |
| GC/MS Integration | Compatible with Agilent 5977, 7000, and 7010 mass spectrometers |
| Retention Time Reproducibility | <0.008% RSD |
| Peak Area Reproducibility | <1% RSD |
| Pressure Control Resolution | 0.001 psi |
| Microfluidic Flow Technology | Integrated Chip-based Flow Path (CFT) with backflush and split capability |
| Environmental Certification | My Green Lab ACT Label (Accountability, Consistency, Transparency) |
| Power Consumption | <50% of conventional GC systems |
| Footprint | 27 cm W × 69 cm D × 51 cm H |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole (QQQ) |
| Model | LC-MS 1200-6410 |
| Mass Range | 10–3000 m/z |
| Sensitivity | S/N ≥ 100:1 (1 pg reserpine, ESI+) |
| Resolution | 0.5–0.7 m/z (FWHM) |
| Mass Accuracy | ±0.1 Da |
| Flow Rate Compatibility | 0.1–2.5 mL/min |
| Ion Source | Jet Stream Electrospray Ionization (ESI) |
| Optional Ion Sources | APCI, APPI |
| Software | MassHunter Workstation (Enhanced QQQ Edition) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Load Lock |
| Instrument Type | Dynamic Axial Compression (DAC) System |
| Power Requirement | Pneumatic (Compressed Air Only) |
| Column Compatibility | Three Standard Bore Sizes |
| Compression Mode | Dual-Mode DAC + Static Axial Compression (SAC) |
| Application Scale | Milligram to Multi-Kilogram Preparative Chromatography |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | micro-ECD |
| Compatible Instrument | Gas Chromatograph (GC) |
| Detector Type | Electron Capture Detector (ECD) |
| Detection Principle | Radioisotope-based electron capture |
| Minimum Detectable Level (MDL) for Lindane | 3.8 fg/mL |
| Linear Dynamic Range | 5 × 10⁴ (fg/mL to ng/mL) |
| Sampling Rate | 5–500 Hz |
| Compliance | U.S. EPA Contract Laboratory Program (CLP) Method 8081B/8270 for pesticide analysis |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Agilent Technologies (Shanghai) Co., Ltd. |
| Type | Nitrogen-Phosphorus Detector (NPD) |
| Compatible Instrument | Gas Chromatograph (GC) |
| Bead Material | High-Performance Glass-Based Blos Rubidium Bead |
| Lifetime | ≥2× that of conventional ceramic rubidium beads |
| N-Compound Sensitivity | Comparable to ceramic beads |
| P-Compound Sensitivity | Enhanced vs. ceramic beads |
| Environmental Tolerance | High resistance to ambient humidity and moisture exposure |
| Regulatory Compliance | Designed for use in GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer | Agilent Technologies |
| Origin Category | Imported |
| Model | OLIGO PRO II |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Sample Type | Organic Analysis (Single-Stranded DNA/RNA Oligonucleotides) |
| Voltage | 100–240 VAC, 47–63 Hz |
| Power Consumption | 150 VA |
| Operating Temperature | 20–23 °C |
| Relative Humidity | 20–60 % |
| Dimensions (W × D × H) | 49 cm × 58 cm × 67 cm |
| Weight | 56 kg |
| Molecular Weight Range | Up to 60-mer (single-base resolution) |
| Capillary Array Options | 12-, 24-, or 96-capillary configurations |
| Sample Throughput | Up to 96 samples per run |
| Detection Method | Direct UV absorbance (260 nm), dye-free |
| Resolution | n−1 for ssDNA/ssRNA ≤60 nt |
| Brand | Agilent Technologies |
|---|---|
| Origin | Switzerland |
| Manufacturer | Agilent Technologies |
| Product Category | Imported Instrument |
| Model | PAL3 Series 2 |
| Instrument Type | Gas Chromatography Autosampler |
| Sample Capacity (2 mL vials) | up to 1458 (160 cm configuration) |
| Sample Capacity (10/20 mL vials) | up to 405 (160 cm configuration) |
| Compatible GC Platforms | Agilent 8890, 8860, Intuvo 9000, 7890, 7820 |
| Compatible Software | OpenLab CDS, MassHunter, ChemStation, EZChrom |
| Supported Sampling Modes | Liquid Injection, Static/Dynamic Headspace, SPME (Fiber & Arrow), RTC Tool Exchange |
| Integrated Sample Prep Functions | Dilution, Solvent Addition, Stirring, Centrifugation, Washing, Temperature-Controlled Handling |
| Consumables Intelligence | RFID/NFC-enabled smart chips for traceable usage history and automated reporting |
| Brand | Agilent Technologies |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | PHD-4 |
| Price Range | USD 13,500 – 40,500 |
| Brand | Agilent Technologies |
|---|---|
| Origin | United Kingdom |
| Model | PL-GPC 50 |
| Operating Temperature Range | Ambient to 50 °C |
| Detector Options | UV, PL-RI (Refractive Index), PL-BV400RT (Viscometer), Multi-Angle Light Scattering (MALS) |
| Solvent Delivery System | High-Precision Isocratic Pump |
| Autosampler | Integrated Six-Position Valve-Based Injector |
| Compliance | Designed for ISO 16014, ASTM D5296, and USP <621> SEC/GPC Method Requirements |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ProStar/PrepStar/SepTech Skid |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Flow Rate Range | 0.001–3200 mL/min |
| Maximum Pressure | 8700 psi (600 bar) |
| UV-Vis Detector Wavelength Range | 190–700 nm |
| UV-Vis Detector Noise | ±5 × 10⁻⁶ AU |
| Compliance | GLP, ISO 9001, cGMP (design-qualified), FDA 21 CFR Part 11-ready software architecture |
| Brand | Agilent Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | RapID |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Discontinued Date | 1 August 2025 |
| Brand | Agilent Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Resolve |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| IP Rating | IP67 |
| Laser Wavelength | 830 nm |
| Maximum Laser Power | 475 mW |
| Dimensions (W × H × D) | 155 mm × 290 mm × 73 mm |
| Weight | 2.2 kg |
| Power Supply | Rechargeable Lithium-ion Battery with AC Adapter |
| Connectivity | USB 2.0, Optional Wi-Fi Module |
| Operating Modes | Through-Packaging SORS, Surface Raman, Glass Bottle Mode |
| Analysis Time (Typical) | ~60 s for Solids, Powders, Liquids, and Mixtures |
| Supported Languages | English, Korean, German, Chinese, French, Portuguese, Japanese, Spanish, Czech |
| Onboard Library Tiers | Standard, Toxic & Hazardous Materials, Comprehensive |
| Library Update Frequency | Biannual |
| Software Platform | Agilent Command Instrument Group Management Software |
| Regulatory Compliance | Designed to support GLP/GMP workflows |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Revident LC/Q-TOF |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Application Field | General-Purpose Small-Molecule Analysis |
| Mass Range | m/z 20–10,000 |
| Sensitivity | <40 fg on-column reserpine (positive mode), <40 ppt (S/N ≥ 1000:1 for 1 pg on-column) |
| <40 fg on-column chloramphenicol (negative mode), <40 ppt (S/N ≥ 750 | 1 for 1 pg on-column) |
| Resolution | TOF mass resolution (FWHM) >60,000 at m/z 2722, acquisition-rate independent |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | SD-1 |
| Instrument Type | Ultra-High Performance Liquid Chromatography–Online Solid-Phase Extraction (UHPLC–Online SPE) Coupled Purification System |
| Flow Rate Range | 1–200 mL/min (upgradable to 500 mL/min or 800 mL/min) |
| Maximum Pressure Rating | 400 bar |
| Sample Injection Volume | 0.1–10 mL (via manual loop or Agilent 410 Autosampler) |
| Temperature Control Range | Ambient to 80 °C (column oven optional) |
| Wavelength Range | 190–800 nm (Agilent 325 UV-Vis Detector) |
| Data Acquisition Rate | Up to 100 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Markes International (OEM for Agilent) |
| Instrument Type | Thermal Desorption Autosampler for Gas Chromatography |
| Compatibility | Fully Integrated with Agilent GC and GC/MS Systems |
| Carrier Gases | Hydrogen, Helium, Nitrogen |
| Sample Capacity | Up to 100 Sorbent Tubes |
| Automation Mode | Stacked Tube Processing |
| Gas Configuration Options | 14-channel, 4-channel, or 3-channel online gas manifold |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5975 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Chromatography Type | Conventional Gas Chromatography-Mass Spectrometry |
| Mass Range | 1.5–1050 amu |
| Resolution | 1000–2000 (FWHM at m/z 502) |
| Sensitivity | >300:1 (Signal-to-Noise Ratio, SIM mode, m/z 502, 100 fg injected) |
| Scan Speed | 10,000 u/s |
| Includes | Agilent 7820A GC, Agilent 5975(G3175A) MSD, Agilent 7693A Autosampler (150-position tray), Turbomolecular Vacuum Pump, Dedicated PC with ChemStation Software |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | TCD for GC Systems |
| Compatible Instruments | Agilent Intuvo 9000, 8890, 8860, and 7890 Gas Chromatographs |
| Detector Type | Universal Thermal Conductivity Detector |
| Baseline Drift | Ultra-low drift enabled by proprietary fluid-switching architecture with rapid post-startup stabilization |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrumentation |
| Model Series | Lumin, AQUATek 100, Atomx |
| Instrument Type | Gas Chromatography (GC) Purge-and-Trap Sample Introduction System |
| Compliance | Designed for ASTM D5024, D6227, EPA Methods 502.2, 524.2, 624, 8260D, and ISO 15681-2 |