Chemical Analysis Instruments
Filter
Showing 7741–7770 of 10669 results
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Gas Chromatography Interface |
| Mass Range | 1–1200 m/z |
| Resolution | 0.7–4 amu (full width at half maximum, FWHM) |
| Detection Limit (IDL) | <1 fg (octafluoronaphthalene, OFN) |
| Scan Speed | ≥14,000 amu/sec |
| Oven Ramp Rate | ≥125 °C/min |
| Pressure Control Accuracy | ±0.001 psi |
| Ion Source | High-Temperature Inert Dual-Filament Electron Ionization Source |
| Pre-filter | Dual-Axis Pre-quadrupole |
| Detector | Long-Life Extended-Dynamic-Range Electron Multiplier |
| Vacuum System | High-Capacity Turbomolecular Pump (≥300 L/s N₂) |
| Flow Control | Digital Electronic Flow Control (EFC) on All Inlets and Detectors |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | 456i |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | –100 °C to 450 °C |
| Maximum Ramp Rate | 150 °C/min |
| Maximum Cool-Down Rate | 150 °C/min |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Brand | SCION |
|---|---|
| Origin | Netherlands |
| Manufacturer | SCION Instruments B.V. |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient to 450 °C |
| Maximum Ramp Rate | 170 °C/min |
| Maximum Cooling Rate | 150 °C/min |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Brand | Scion |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 8500-GC |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient to 450 °C |
| Maximum Ramp Rate | 170 °C/min |
| Maximum Cooling Rate | 150 °C/min |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Brand | SCION |
|---|---|
| Origin | Netherlands |
| Manufacturer | SCION Instruments |
| Instrument Type | Single Quadrupole GC-MS |
| GC Platform Options | SCION 8300 / 8500 |
| Mass Range | 1–1200 Da |
| Resolution | 0.7–4 Da (FWHM) |
| Sensitivity (EI Full Scan) | ≥1500:1 S/N for 1 pg Octafluoronaphthalene |
| Scan Speed | 20,000 Da/s |
| Oven Ramp Rate | Up to 180 °C/min |
| Pressure Control Accuracy | ±0.001 psi |
| Ion Source | Axially Oriented, Ultra-Inert Design |
| Vacuum System | High-Capacity Turbo-Molecular Pump (Standard) |
| Brand | SCION |
|---|---|
| Origin | Netherlands |
| Manufacturer | SCION Instruments (a part of Antec Scientific Group) |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary GC-Coupled |
| Mass Range | 1–1200 Da |
| Resolution | 0.7–4.0 Da (full width at half maximum, FWHM) |
| Sensitivity | ≥1500:1 S/N for 1 pg Octafluoronaphthalene (OFN) at m/z 272 |
| Scan Speed | 30,000 Da/s |
| Oven Ramp Rate | Up to 180 °C/min |
| Pressure Control Precision | ±0.001 psi |
| Brand | SCION |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Artemis 6000 |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.01–10.0 mL/min |
| Maximum Pump Pressure | 40 MPa |
| Autosampler Injection Volume | 0–500 µL |
| Autosampler Temperature Control | Yes |
| Post-Column Reactor Temperature Range | Ambient to 180 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic |
| Model | Compass CDS |
| Price Range | USD 35,000 – 85,000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-Purpose Analytical HPLC |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Pressure | 60 MPa |
| Flow Accuracy | ≤0.05% RSD |
| Injection Positions | 100 × 2 mL vials |
| Injection Volume | 0.1–50 µL (standard), 5–2250 µL (optional) |
| Column Oven Temperature Range | Ambient to 85 °C |
| UV-Vis Wavelength Range | 190–600 nm |
| Data Acquisition Frequency | 100 Hz |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | Primaide / Chromaster |
| Pricing | Available Upon Request |
| Brand | SCION |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | HT3 |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automated |
| Vial Heating Range | Up to 300 °C, 1 °C Incremental Control |
| Valve & Transfer Line Temperature Range | Up to 300 °C, 1 °C Incremental Control |
| Temperature Control Accuracy | ±0.05 °C |
| Sample Loop Volume | 1 mL Silco-coated loop standard |
| optional loops | 100 μL, 250 μL, 300 μL, 500 μL, 2 mL, 3 mL, 5 mL |
| Vial Capacity | 60 positions |
| Vial Size | 22 mL |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | LC6000 |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-purpose analytical platform |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Operating Pressure | 60 MPa |
| Flow Precision | <0.05% RSD |
| Autosampler Capacity | 200 positions (1.5 mL vials) |
| Optional Configurations | 128 positions (4 mL vials) |
| Injection Volume Range | 0.1–100 µL (standard) |
| Wavelength Ranges | UV-Vis: 190–900 nm |
| DAD | 190–900 nm |
| Fluorescence (FL) | Ex 200–850 nm / Em 250–900 nm |
| Data Acquisition Rate | Multi-step selectable |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | LC6000-DAD |
| Instrument Category | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-purpose analytical platform |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Pressure Rating | 60 MPa |
| Flow Precision | <0.05% RSD |
| Sample Tray Capacity | 200 positions (1.5 mL vials) |
| Optional Trays | 128 positions (4 mL vials), 288 positions (96-well microplate), 1152 positions (384-well microplate) |
| Injection Volume Range | 0.1–100 µL (standard) |
| DAD Wavelength Range | 190–900 nm |
| Spectral Acquisition Rate | Multi-step adjustable |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic UHPLC System |
| Model | LC6000-FLD |
| Instrument Type | Ultra-High Performance Liquid Chromatograph with Fluorescence Detection |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Pressure | 60 MPa |
| Flow Precision | <0.05% RSD |
| Sample Tray Capacity | 200 positions (1.5 mL vials) |
| Optional | 128 positions (4 mL vials), 288 positions (96-well microplate), 1152 positions (384-well microplate) |
| Injection Volume Range | 0.1–100 µL (standard) |
| Excitation Wavelength Range | 200–850 nm |
| Emission Wavelength Range | 250–900 nm |
| Data Acquisition Frequency | Multi-step adjustable |
| Brand | SCION |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Versa |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Vial Heating Range | 200 °C, Temperature Increment: 1 °C, Stability: ±0.1 °C |
| Valve Oven Temperature Range | 200 °C, Increment: 1 °C |
| Sample Loop Volume | 1 mL Silco-coated loop (optional loops: 100 μL, 250 μL, 300 μL, 500 μL, 2 mL, 3 mL, 5 mL) |
| Vial Capacity | 20 positions |
| Vial Size | 22 mL |
| [Brand | SciTec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Environmental Air Monitoring |
| Oven Temperature Range | Ambient + 5°C to 400°C |
| Oven Ramp Rate | 0.1–39.9°C/min |
| Oven Cool-Down | 300°C to 50°C in <9 min |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–0.4 MPa |
| Injector Max Temp | 400°C |
| Injector Pressure Setpoint Range | 0–0.4 MPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Temperature Control Precision | ±0.01°C |
| EPC/EFC Pressure Accuracy | 0.001 psi |
| EPC/EFC Flow Accuracy | 0.001 mL/min |
| Retention Time RSD | <0.008% |
| Peak Area RSD | <1.0% |
| Detector Options | TCD, FID, ECD, FPD |
| Max Oven Cooling Rate | >120°C/min (with motorized door) |
| Programmable Temperature Steps | Up to 16 standard steps (expandable) |
| Data Interface | RJ45 Ethernet (TCP/IP), native support for multi-instrument network control] |
| Brand | SciTech |
|---|---|
| Model | Direct-Tube Activator |
| Origin | Shanghai, China |
| Manufacturer | SciTech Instruments Co., Ltd. |
| Type | Benchtop Thermal Desorption Tube Activator |
| Temperature Range | 0–400 °C |
| Control Precision | ±0.1 °C |
| Tube Capacity | 5 / 10 / 15 / 20 Straight Adsorption Tubes (ID 6 mm, OD 8 mm) |
| Dimensions (W×D×H) | 350 × 260 × 270 mm |
| Weight | 15 kg |
| Max Power | 500 W |
| Supply | 220 V ±10%, 50 Hz ±5% |
| Operating Environment | 5–35 °C, ≤85% RH |
| Brand | SciTech |
|---|---|
| Model | GC2002 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Petroleum & Petrochemical Industry |
| Detection Modes | TCD (for %–ppm range), FPD (for sub-ppm to ppm-level sulfur) |
| Column Compatibility | Packed & Capillary Columns (sulfur-deactivated) |
| Injection System | VICI pneumatic valve with inertized quantitative loops (0.2–2.0 mL) |
| Oven Temperature Range | Ambient +5°C to 420°C |
| Max Programmed Ramps | 8-stage |
| Temperature Precision | ±0.1% of setpoint |
| FPD Sensitivity | ≤1.0 pg/s (P), ≤10.0 pg/s (S) |
| TCD Sensitivity | ≥10,000 mV·mL/mg (HTCD) |
| Baseline Noise (FPD) | ≤30 µV |
| Linear Dynamic Range | 10⁴ (FPD), 10⁵ (TCD) |
| Data Interface | RJ45 Ethernet (remote control & audit-ready data streaming) |
| Software | Embedded workstation with bidirectional instrument control, GLP-compliant event logging, and 253-unit network scalability |
| Brand | SciTech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Category | Laboratory Gas Chromatograph for Environmental Monitoring |
| Model | GC2002 Networked GC + KC Series Automated Gas Sampler |
| Temperature Control Range | Ambient +5°C to 450°C |
| Oven Ramp Rate | 0–40°C/min |
| Cooling Time | ≤4 min (from 450°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | FID with Detection Limit ≤3.0×10⁻¹² g/s (n-Hexadecane), Baseline Noise ≤1.0×10⁻¹³ A, Drift ≤5.0×10⁻¹³ A (30 min), Linear Range 10⁷ |
| Sample Capacity | 16–85 positions (field-upgradable) |
| Injection Precision | RSD <0.5% (n=10, total hydrocarbons & methane peak areas) |
| Injection Volume Options | 1, 2, or 3 mL quantitative loop |
| Sampling Pump | Max flow 10 L/min, ultimate vacuum –80 kPa |
| Tubing Material | PTFE |
| Calibration Function | Automated 8-point standard curve generation |
| Brand | SciTech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Power Industry–Specific DGA |
| Temperature Control Range | +5 °C to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | 300 °C → 50 °C in ≤4 min |
| Carrier Gas Flow Range & Control | 0–350 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–300 mL/min |
| Brand | SciTech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC9800 Base |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 10 °C to 400 °C |
| Oven Ramp Rate | 0.1–39 °C/min |
| Oven Cooling Rate | 400 °C → 50 °C in ≤4 min |
| Carrier Gas Flow Range & Control | 0–100 mL/min |
| Carrier Gas Pressure Range & Control | 0–250 kPa |
| Injector Maximum Operating Temperature | 300 °C |
| Injector Pressure Setting Range | 0–250 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Column Oven Dimensions | 250 × 250 × 180 mm |
| Temperature Control Accuracy | ±0.5% of setpoint |
| Temperature Display Resolution | 0.1 °C |
| Programmable Temperature Steps | 3-step |
| Programmed Temperature Reproducibility | ≤1% RSD |
| Detector Options | TCD, FID, ECD, FPD |
| TCD Sensitivity | ≥3000 mV·mL/mg (benzene) |
| FID Detection Limit | ≤1 × 10⁻¹¹ g/s (n-hexadecane) |
| ECD Detection Limit | ≤1 × 10⁻¹³ g/mL (γ-HCH) |
| FPD (P) Detection Limit | ≤5 × 10⁻¹² g/s |
| FPD (S) Detection Limit | ≤5 × 10⁻¹¹ g/s |
| TCD Baseline Noise | ≤10 µV |
| FID Baseline Noise | ≤1 × 10⁻¹³ A |
| ECD/FPD Baseline Noise | ≤40 µV |
| TCD Baseline Drift | ≤60 µV/30 min |
| FID Baseline Drift | ≤6 × 10⁻¹³ A/30 min |
| ECD/FPD Baseline Drift | ≤100 µV/30 min |
| TCD/FID/ECD/FPD Linear Dynamic Ranges | 10⁵, 10⁷, 10⁴, 10⁴ respectively |
| Detector Stabilization Time | ≤2 h (TCD/ECD), ≤1 h (FID/FPD) |
| Instrument Dimensions | 500 × 540 × 480 mm |
| Net Weight | 35 kg |
| Power Consumption | 1500 W |
| Brand | SciTech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Dedicated to High-Purity Gas Analysis |
| Oven Temperature Range | 8 °C above ambient to 400 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | 400 °C → 50 °C in ≤4 min |
| Carrier Gas Flow Control Range | 0–100 mL/min |
| Carrier Gas Pressure Control Range | 0–250 kPa |
| Injector Maximum Temperature | 300 °C |
| Injector Pressure Setting Range | 0–250 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector Configuration | TCD (TC-1H) + FID + Ni Methanizer + Gas Sampling System + Capillary/Packed Column System |
| Temperature Control Accuracy | ±0.5% of setpoint |
| Programmable Temperature Steps | 8 |
| Linear Range (FID) | 10⁷ |
| Linear Range (TCD) | 10⁵ |
| FID Detection Limit | ≤1×10⁻¹¹ g/s (n-hexadecane) |
| TCD Sensitivity | ≥3000 mV·mL/mg (benzene) |
| FID Baseline Noise | ≤1×10⁻¹³ A |
| TCD Baseline Noise | ≤10 µV |
| FID Baseline Drift | ≤6×10⁻¹³ A/30 min |
| TCD Baseline Drift | ≤60 µV/30 min |
| Brand | SciTech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Laboratory Gas Chromatograph |
| Model | GC9800-N/FH |
| Instrument Type | Laboratory Gas Chromatograph |
| Primary Application | Dedicated High-Purity Gas Analysis |
| Oven Temperature Range | 8 °C above ambient to 400 °C |
| Oven Ramp Rate | 0.1–39 °C/min (adjustable in 0.1 °C increments) |
| Oven Cooling Rate | 400 °C → 50 °C in ≤4 min |
| Carrier Gas Flow Range & Control | 0–100 mL/min |
| Carrier Gas Pressure Range & Control | 0–250 kPa |
| Injector Maximum Operating Temperature | 300 °C |
| Injector Pressure Setting Range | 0–250 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| FID Detection Limit | ≤8.0×10⁻¹² g/s (n-hexadecane) |
| FID Baseline Noise | ≤1×10⁻¹³ A |
| FID Baseline Drift | ≤7×10⁻¹³ A / 30 min |
| FID Linear Dynamic Range | 10⁷ |
| Temperature Control Accuracy | ±0.5% of setpoint |
| Max. Temperature Program Steps | 8 |
| Temperature Program Reproducibility | ≤1% RSD |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer | LANScientific |
| Type | Benchtop/Floor-Standing Hybrid |
| Configuration | Conventional ED-XRF System |
| Application Sector | Non-Ferrous Metals Recycling |
| Elemental Range | Al (13) to U (92) |
| Detection Limit | Sub-ppm to % level (matrix-dependent) |
| Safety Compliance | IEC 62495, GB/Z 25480, EN 61000-6-3 |
| Software | ScopeX Analyze v3.2 with Audit Trail & CFR Part 11 Ready Mode |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Benchtop/Floor-Standing ED-XRF |
| Model | ScopeX 980CS / ScopeX 980CSR |
| Elemental Range | Na (11) to U (92) |
| Detection Limit | 1 ppm (typical, matrix-dependent) |
| Energy Resolution | <125 eV at Mn Kα (5.89 keV) |
| Repeatability | ≤0.1% RSD (for major elements under optimized conditions) |
| Detector | Peltier-cooled Silicon Drift Detector (SDD) |
| Sample Chamber | Dual-mode (air/vacuum) with motorized sample stage |
| Excitation Source | Rhodium-anode microfocus X-ray tube |
| Collimators | 5 mm, 3 mm, 1 mm, 0.5 mm (motorized auto-switching) |
| Filters | Multi-position filter wheel (Al, Cu, Ti, none) |
| Data Interface | USB 3.0, Wi-Fi 5 (802.11ac), Bluetooth 5.0 |
| Report Output | Customizable Excel/PDF templates with spectral overlays, logo embedding, and metadata fields |
| Safety Compliance | Fully shielded metal enclosure with interlocked vacuum door |
| Brand | SDL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic |
| Model | MODEL 3080GC-MS |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Gas Chromatograph |
| Mass Range | 41–300 AMU |
| Scan Speed | 1000 AMU/s |
| Detector | Quadrupole Mass Analyzer |
| Pressure Control Accuracy | Not Specified |
| Resolution | Not Specified |
| Sensitivity | Not Specified |
| Mass Accuracy | Not Specified |
| Oven Ramp Rate | Not Specified |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | AA100 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 250–1000 nm |
| Sample Capacity | Configurable (via rotary autosampler) |
| Reagent Positions | Unlimited (modular reagent rack support) |
| Flow Cell Path Length | 10 mm |
| Light Source | High-Stability LED |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | AA100 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 25–1000 nm |
| Sample Capacity | Configurable (via rotary autosampler) |
| Reagent Positions | Unlimited (modular reagent rack support) |
| Cuvette Path Length | 10 mm |
| Light Source | High-Stability LED |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | AA100 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 180 positions / 120 cups |
| Reagent Positions | 17 |
| Flow Cell Path Length | 10–50 mm |
| Light Source | LED |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | AA3 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–900 nm |
| Sample Capacity | 120 / 180 / 270 positions |
| Reagent Positions | Unlimited |
| Cuvette Path Length | 10 mm, 30 mm, 50 mm |
| Light Source | High-Pressure Krypton Lamp / LED |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | AA3 |
| Product Type | Continuous Flow Analyzer |