Chemical Analysis Instruments
Filter
Showing 9511–9540 of 9903 results
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | FP6432 |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Ba | 0–3000 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Flow Rate | < 6 mL/min |
| Wavelength Accuracy | K/Li/Ca/Ba ≤ ±7 nm |
| Bandwidth (FWHM) | ≤ 15 nm for all elements |
| Background Transmittance | ≤ 0.5% |
| Power Supply | AC 220 ± 22 V, 50 ± 1 Hz |
| Rated Power | 30 W |
| Display | 7-inch capacitive touch LCD |
| Data Storage | 10-point calibration curves (max), 200 sample records |
| Connectivity | USB port, U-disk export, cloud-enabled interface |
| Safety Features | Flame-out detection, gas leak alarm |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | FP6440 |
| Detection Elements | K, Na, Li, Ca |
| Detection Limits | K: 0.001 mmol/L |
| Na | 0.001 mmol/L |
| Li | 0.005 mmol/L |
| Ca | 0.01 mmol/L |
| Response Time | <8 s |
| Repeatability | RSD ≤1.5% |
| Nebulization Flow Rate | 6–8 mL/min |
| Display | 7-inch capacitive touch LCD |
| Safety Features | Flame-out protection, gas leakage alarm |
| Data Interface | USB port, U-disk export, PC connectivity |
| Cloud Connectivity | Yes |
| Calibration Function | Automatic correlation coefficient calculation |
| Optional Accessory | Thermal printer |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | FP6450 |
| Detection Elements | K, Na, Li, Ca, Ba |
| Detection Limits | K: 0.001 mmol/L |
| Na | 0.001 mmol/L |
| Li | 0.005 mmol/L |
| Ca | 0.01 mmol/L |
| Ba | 0.02 mmol/L (typical) |
| Response Time | <8 s |
| Repeatability | RSD ≤1.5% |
| Sample Uptake Rate | 6–8 mL/min |
| Display | 7-inch capacitive touchscreen LCD |
| Data Storage | Up to 10-point calibration curves and 200 sample results |
| Connectivity | USB port, USB flash drive export, cloud-enabled data synchronization |
| Safety Features | Automatic flame-out detection, gas leak alarm |
| Calibration Modes | Linear and piecewise linear (broken-line) |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Rated Power | 30 W |
| Printer | Optional external thermal printer |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | i-301 |
| Portability | Portable |
| Intended Use | Laboratory |
| Conductivity Range | 0.000 µS/cm to 200 mS/cm |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–10 MΩ·cm |
| Salinity Range | 0–80 ppt |
| Temperature Range | −5 to 55 °C |
| Accuracy | ±0.5% FS (conductivity), ±0.1 °C (temperature) |
| Minimum Resolution | 0.01 µS/cm (conductivity), 0.1 °C (temperature) |
| Display | 7-inch color TFT capacitive touchscreen |
| Calibration | Auto-identification of standard solutions |
| cell constant options | 0.01, 0.1, and 1.0 cm⁻¹ |
| Compliance | IP54 ingress protection |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | i3 |
| Optical System | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 360–900 nm (Visible) |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ≤1 nm |
| Stray Light | ≤0.5% T at 420 nm (NaNO₂) |
| Display | 7-inch TFT touchscreen (1024 × 768) |
| Photometric Range | 0–200% T, –0.3 to 3.0 A |
| Wavelength Setting | Automatic |
| Light Source | Dual-lamp system with long-life halogen and deuterium lamps (optional UV extension) |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2, RS-232 |
| Software Functions | Wavelength scanning, kinetic analysis, quantitative analysis, nucleic acid/protein assay, spectral overlay, derivative/integration processing |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | i4 |
| Instrument Architecture | Single-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ≤1 nm |
| Spectral Bandwidth | 4 nm |
| Stray Light | ≤0.5% T at 420 nm (NaNO₂) |
| Photometric Range | 0–200% Transmittance, –0.3 to 3.0 Absorbance |
| Display | 7-inch capacitive touchscreen (1024 × 768 resolution) |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2, RS-232 |
| Software Functions | Wavelength Scanning, Kinetic Measurement, Quantitative Analysis, Nucleic Acid & Protein A260/A280 Assay, Multi-Wavelength Overlay, First-Order Derivative, Integration |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | i5 |
| Quotation | Upon Request |
| Optical Design | Single-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 360–900 nm (Visible Region) |
| Wavelength Scanning | Automatic |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ≤1 nm |
| Stray Light | ≤0.5%T at 420 nm (NaNO₂ reference) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | i6 |
| Optical System | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ≤1 nm |
| Stray Light | ≤0.5% T at 420 nm (NaNO₂) |
| Photometric Range | 0–200% T, –0.3 to 3.0 A |
| Display | 7-inch capacitive touchscreen (1024 × 768 px) |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2, RS-232 |
| Auto Functions | Automatic wavelength calibration, automatic lamp switching (D₂/WS), T/A mode toggle, real-time baseline correction |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L-211 |
| Form Factor | Benchtop |
| Intended Use | Laboratory |
| Conductivity Range | 0.01 μS/cm to 100 mS/cm |
| TDS Range | 0.01 mg/L to 100 g/L |
| Resistivity Range | 0.01 Ω·cm to 100 MΩ·cm |
| Salinity Range | 0.01 ‰ to 100 ‰ |
| Temperature Range | 0–100 °C |
| Accuracy | ±1% FS (conductivity), ±0.5 °C (temperature) |
| Minimum Resolution | 0.01 μS/cm (conductivity), 0.1 °C (temperature) |
| Display | 7-inch color capacitive touchscreen |
| Calibration | Auto-recognition of 8 standard solutions (including ISO/ASTM-compliant KCl standards), single-point or multi-point calibration |
| Compensation | Automatic and manual temperature compensation (ATC/MTT) |
| Data Management | Statistical analysis (mean, SD, min/max), audit-trail-capable storage, print-ready export, GLP/GMP-compliant metadata tagging |
| Protection Rating | IP54 |
| Electrode Compatibility | Standard 1.0 cm⁻¹ cell (optional 0.1 or 0.01 cm⁻¹ cells for low-conductivity samples) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L-311 |
| Portability | Portable |
| Intended Use | Laboratory |
| Conductivity Range | 0.000 µS/cm to 200 mS/cm |
| TDS Range | 0 to 100 g/L |
| Resistivity Range | 0 to 10 MΩ·cm |
| Salinity Range | 0 to 80 ppt |
| Temperature Range | −5 to 55 °C |
| Accuracy | ±0.5% FS (conductivity), ±0.1 °C (temperature) |
| Minimum Resolution | 0.01 µS/cm (conductivity), 0.1 °C (temperature) |
| Display | 7-inch color TFT capacitive touchscreen |
| Compliance | IP54 |
| Calibration | Auto-recognition of 8 standard solutions (including ISO and GB standards), single-point or multi-point calibration supported |
| Electrode Constant Options | 0.01, 0.1, 1.0 cm⁻¹ (1.0 cm⁻¹ electrode supplied) |
| Data Management | Statistical analysis (min/max/avg/stdev), storage ≥1000 data points, print-ready output, audit-trail-capable logging, firmware upgradability, power-failure recovery, factory reset |
| Temperature Compensation | Automatic (linear & non-linear NIST/ISO models) and manual modes |
| Language Support | English & Chinese UI |
| Environmental Rating | IP54 |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L-3700 |
| Optical System | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.03% (at 220 nm, using NaI solution) |
| Display | 8-inch capacitive touchscreen (1024 × 800 resolution) |
| Internal Storage | 5000 absorbance measurements or 500 calibration curves |
| Data Export Formats | *.csv, *.qua, *.txt, *.bmp |
| Compliance | GLP/GMP-aligned software architecture with user management, audit trail, and electronic signature support |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | L-3700S |
| Instrument Architecture | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 1 nm (standard), adjustable to 0.5/2.0/4.0/5.0 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.03% at 220 nm (using NaI solution) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L-3800 |
| Optical System | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% (at 220 nm, using NaI) |
| Display | 8-inch capacitive touchscreen (1024 × 800 resolution) |
| Light Source | Imported deuterium and tungsten lamps |
| Internal Data Storage | Up to 5000 absorbance measurements or 500 calibration curves |
| Scan Speed | Full-spectrum scan in <1.5 s |
| Auto-functions | Automatic wavelength calibration, source switching, zero adjustment, and baseline correction |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | L-3800S |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm (fixed), with optional 0.5/2.0/4.0/5.0 nm selectable via software |
| Stray Light | ≤0.03% T at 220 nm (NaI) |
| Absorbance Range | –4 to +4 Abs |
| Display | 8-inch capacitive touchscreen (1024 × 800 resolution) |
| Internal Storage | 5000 absorbance measurements or 500 calibration curves |
| Data Export Formats | CSV, QUA, TXT, BMP |
| Compliance | GLP/GMP-ready software architecture with user management, audit trail, and electronic record retention |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | L1 |
| Instrument Architecture | Single-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm (UV-Vis) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ≤0.5 nm |
| Spectral Bandwidth | 2 nm (standard), 4 nm (default per spec sheet) |
| Stray Light | ≤0.5% T at 420 nm (NaNO₂ method) |
| Display | 7-inch color TFT-LCD touchscreen (1024 × 768 resolution) |
| Data Storage | 2000 spectra or absorbance readings |
| Connectivity | USB 2.0 port, integrated Wi-Fi module, Bluetooth 5.0 module |
| Software Compatibility | Yokelab PC software (optional), cloud sync via YOKE@Cloud Data app |
| Data Export | CSV/Excel-compatible format via USB flash drive |
| Compliance | Designed to support GLP-compliant workflows with timestamped audit trails, user-access logging, and exportable metadata |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L2 |
| Optical System | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ≤0.5 nm |
| Spectral Bandwidth | 2 nm (standard), 4 nm (optional) |
| Stray Light | ≤0.5% T at 420 nm (NaNO₂) |
| Display | 7-inch color TFT-LCD (1024 × 768) with capacitive touch |
| Data Storage | 2000 spectra + 96 calibration curves |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2 |
| Software Interface | Yokelab PC software (optional), YOKE@Cloud Data mobile app (QR-code enabled) |
| Output Format | CSV/Excel-compatible export via USB drive |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L3 |
| Optical Design | Single-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 320–1100 nm |
| Spectral Bandwidth | 4 nm (2 nm optional) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ≤±0.5 nm |
| Stray Light | ≤0.1% T at 420 nm (NaNO₂) |
| Photometric Range | 0–200% T, –3 to +3 A |
| Photometric Accuracy | ±0.5% T / ±0.004 A (0–0.5 A), ±0.008 A (0.5–1 A) |
| Photometric Repeatability | ±0.5% T / ±0.004 A (0–0.5 A), ±0.008 A (0.5–1 A) |
| Baseline Stability | ±0.002 A (500 nm, 3 min) |
| Noise Level | ≤0.15% T |
| Grating | Holographic Blazed Grating, 1200 lines/mm |
| Display | 7-inch TFT-LCD Touchscreen (1024 × 768) |
| Connectivity | USB 2.0, Wi-Fi (standard), Bluetooth 4.2 (standard) |
| Data Storage | 2000 spectra + 96 calibration curves |
| Software | YokeLab PC software (optional), YOKE@Cloud IoT platform (standard) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L4 |
| Optical System | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.5 nm |
| Spectral Bandwidth | 4 nm (2 nm optional) |
| Stray Light | ≤0.1% T |
| Display | 7-inch color TFT LCD (1024 × 768) |
| Data Storage | 2000 spectra + 96 calibration curves |
| Scan Speed | up to 3000 nm/min |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2 |
| Software Compatibility | Yokelab PC Suite (optional), cloud-integrated via YOKE@Cloud Data app |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | L5 |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm (UV-Vis) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ≤0.5 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.5% T at 420 nm (NaNO₂) |
| Automation Level | Automatic Wavelength Selection & Lamp Switching |
| Data Storage Capacity | 500 spectra, 30 calibration curves |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2 |
| Software Compatibility | Yokelab PC Suite (optional), Excel-compatible CSV export |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L6 |
| Optical Design | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% at 220 nm (NaI) |
| Automation Level | Automatic Wavelength Scanning & Lamp Switching |
| Connectivity | USB 2.0, Wi-Fi Module, Bluetooth 4.2 |
| Data Storage Capacity | 500 spectra, 30 calibration curves |
| Software Compatibility | Yokelab PC Suite (optional), Excel-compatible CSV export |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | L8 Series |
| Price | USD 2,500 (FOB Shanghai) |
| Optical Design | Dual-Beam Ratio System |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% T (at 220 nm, using NaI solution) |
| Display | 10-inch capacitive touchscreen (1024 × 800 resolution) |
| Data Storage | Internal memory for up to 5,000 absorbance readings or 500 calibration curves |
| Connectivity | RS-232C (printer), USB Device (PC connection), USB Host (U-disk support) |
| File Export Formats | CSV, QUA, TXT, BMP |
| Optional Accessories | 8-position automated cuvette changer, integrated flow cell module |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | M5 |
| Optical System | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 0.1 / 0.2 / 0.5 / 1 / 2 / 4 / 5 nm (adjustable) |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ≤1 nm |
| Stray Light | ≤0.5% (at 220 nm, using NaI solution) |
| Photometric Resolution | 0.00001 Abs |
| Display | 11-inch 2.8K tablet with touch interface |
| Light Sources | Deuterium lamp + Tungsten-halogen lamp |
| Connectivity | Bluetooth, Wi-Fi, IoT-enabled remote monitoring |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | M600 |
| Optical System | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% (at 220 nm, using NaI) |
| Absorbance Resolution | 0.00001 Abs |
| Photometric Range | –4 to +4 Abs |
| Light Sources | Deuterium lamp (UV), Tungsten-halogen lamp (Vis) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | M6S |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm (standard), adjustable from 0.1 to 5 nm |
| Stray Light | ≤0.03% at 220 nm (using NaI solution) |
| Photometric Resolution | 0.00001 Abs |
| Auto-Wavelength Scanning | Yes |
| Light Sources | Deuterium Lamp + Tungsten-Halogen Lamp |
| Display | Integrated 11-inch 2.8K tablet with Bluetooth connectivity |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments, supports GLP/GMP data integrity requirements including user-level access control and audit trail-ready operation |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | M700S |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% at 220 nm (using NaI solution) |
| Photometric Range | –4 to +4 Abs |
| Photometric Resolution | 0.00001 Abs |
| Wavelength Scanning Automation | Fully Automatic |
| Display Interface | 11-inch 2.8K resolution tablet with integrated Bluetooth connectivity |
| Software Language Support | Auto-switching between English and Chinese |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | M8 |
| Optical System | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% T (at 220 nm, NaI solution) |
| Absorbance Resolution | 0.00001 Abs |
| Absorbance Range | –4 to +4 Abs |
| Light Sources | Deuterium lamp + Tungsten-halogen lamp |
| Automation | Motorized wavelength scanning, auto-zero, auto-calibration |
| Connectivity | Bluetooth 5.0, Wi-Fi, cloud-enabled IoT architecture |
| Display | Integrated 11-inch 2.8K resolution tablet with touch interface |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | M900 |
| Optical System | Dual-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% (at 220 nm, using NaI) |
| Photometric Range | –4 to +4 Abs |
| Photometric Resolution | 0.00001 Abs |
| Light Sources | Deuterium Lamp & Tungsten Halogen Lamp |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | RG-3604AA |
| Wavelength Range | 190–900 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Wavelength Accuracy | ±0.1 nm |
| Photometric Range (Absorbance) | 0–2.0 A |
| Optical System | Single-beam |
| Lamp Positions | 4 |
| Background Correction | Combined D₂ Lamp + Self-Reversal Full-Spectrum Background Correction |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | RG-3608AA |
| Wavelength Range | 190 nm – 900 nm |
| Wavelength Repeatability | ≤ 0.05 nm |
| Wavelength Accuracy | ±0.1 nm |
| Photometric Range (Absorbance) | 0 – 2.0 A |
| Background Correction | Deuterium Lamp + Self-Reversal Full-Spectrum Correction |
| Lamp Holder | 8-position, 360° Rotating, Compatible with High-Performance Hollow Cathode Lamps |
| Optical System | Single-Beam, All-Reflective Optics |
| Atomizer Type | Flame-Based Atomization System |
| Software Platform | RG-WinAAS Workstation (Windows OS) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | RG-3618AA |
| Wavelength Range | 190–900 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Wavelength Accuracy | ±0.1 nm |
| Photometric Range | 0–2.0 A (Absorbance) |
| Optical System | Dual-Beam |
| Lamp Positions | 8-position rotating turret (compatible with high-performance hollow cathode lamps) |
| Background Correction | Combined deuterium lamp and self-reversal (SR) full-spectrum background correction |