Chemical Analysis Instruments
Filter
Showing 9421–9450 of 10621 results
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP306 |
| Pricing | Upon Request |
| Display | 5.0-inch color touchscreen (Chinese UI) |
| Measurement Principle | Photometric colorimetry based on molybdenum blue reduction method |
| Measuring Range | 0–200 µg/L and 0–2000 µg/L (selectable) |
| Accuracy | ±2% FS |
| Resolution | 0.1 µg/L |
| Repeatability | ≤1% |
| Stability | ±1% FS/4h |
| Light Source | Imported monochromatic cold LED |
| Environmental Operating Temperature | 5–45 °C |
| Humidity Limit | ≤90% RH (non-condensing) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤30 W |
| Dimensions | 260 × 200 × 180 mm |
| Weight | 3.2 kg |
| Data Storage | Cyclic memory for up to 256 records |
| Calibration | Blank calibration + optional curve calibration |
| Compliance | Implements national standard silica determination method (molybdenum blue spectrophotometry) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Region | Domestic (China) |
| Model | TP307 |
| Pricing | Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP307 |
| Pricing | Available Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP307 |
| Pricing | Available Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TP307 |
| Pricing | Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP307 |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TP308 |
| Pricing | Available Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | TP311 |
| Instrument Type | Benchtop |
| Parameter Capability | Multi-parameter |
| Measurement Accuracy | ±0.02 pH |
| pH Range | 0.00–14.00 pH |
| Resolution | 0.01 pH |
| Calibration Standard | NIST-traceable buffer solutions |
| Input Impedance | ≥1 × 10¹² Ω |
| Repeatability | ≤1% |
| Stability | ±1% F.S./4 h |
| Response Time (T90) | <1 min at 25 °C |
| Temperature Compensation Range | 0–60 °C |
| Temperature Sensor | Pt1000 |
| Operating Temperature | 5–60 °C (sample), 5–45 °C (ambient) |
| Relative Humidity | ≤90% RH (non-condensing) |
| Storage/Transport Temp | −25–55 °C (electrode excluded |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤5 W |
| Dimensions | 200 × 200 × 85 mm |
| Weight | 2.1 kg |
| Display | 5.0-inch color touchscreen LCD with Chinese UI |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | TP320 |
| Detection Parameter | Single-Parameter (Conductivity) |
| Form Factor | Benchtop |
| Conductivity Range | 0–30,000 mS/cm |
| TDS Range | 0–100 g/L |
| Resistivity Range | Up to 1 × 10¹² Ω·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | 0.0–99.9 °C |
| Accuracy | ±1% F.S. |
| Minimum Resolution | 0.01 µS/cm |
| Display | 5.0-inch Color Touch LCD (Chinese UI) |
| Temperature Sensor | Pt1000 |
| Auto-Temperature Compensation | 0–60 °C |
| Repeatability | ≤1% |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤5 W |
| Dimensions | 200 × 200 × 85 mm |
| Weight | 2.1 kg |
| Data Retention | >10 years (non-volatile memory) |
| Electrode Options | K=0.01, 0.1, 1.0, and 10.0 cm⁻¹ conductivity cells (platinum black or stainless steel) |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TP320 |
| Price | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TP320 |
| Detection Parameter | Single-parameter (Conductivity) |
| Form Factor | Benchtop |
| Conductivity Range | K=0.01 cm⁻¹: 0.000–3.000 µS/cm and 0.00–30.00 µS/cm |
| K=0.10 cm⁻¹ | 0.00–30.00 µS/cm and 0.0–300.0 µS/cm |
| K=1.00 cm⁻¹ | 0.0–300.0 µS/cm and 0–3000 µS/cm |
| K=10.0 cm⁻¹ | 0–3000 µS/cm and 0–30,000 µS/cm |
| TDS Range | 0–100 g/L |
| Resistivity Range | Same as conductivity ranges per cell constant |
| Salinity Range | 0–100 ppt |
| Temperature Range | 0–60 °C |
| Accuracy | ±2.5% of Full Scale |
| Minimum Resolution | 0.001 µS/cm |
| Brand | Timepower |
|---|---|
| Model | TP 330 |
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Category | Domestic |
| Price | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TP330 |
| Pricing | Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | TP330 |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TP330 |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP330 Power Plant Sodium Ion Analyzer |
| Price | Upon Request |
| Brand | Timepower |
|---|---|
| Model | TP3301 |
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance | HJ 637–2018 |
| Measurement Principle | Infrared Spectrophotometry (Triple-Wavenumber Absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 3030 cm⁻¹) |
| Sample Preparation | Tetrachloroethylene Extraction + Magnesium Silicate Adsorption |
| Output | Total Extractable Hydrocarbons, Petroleum Hydrocarbons, and Animal/Vegetable Oils (by difference) |
| Operational Mode | Standalone with Onboard Data Processing |
| Calibration | Reference Coefficient-Based (No Calibration Curve Required) |
| Wavenumber Accuracy | < 1 cm⁻¹ (Secant-Mode Scanning) |
| Optical System | Integrated Beam Path with Pulsed IR Source, Active Narrowband Filtering, and Digital Lock-in Amplification |
| Zero Adjustment | Real-time Auto-zero During Source Off-Cycle |
| Display & Interface | Chinese GUI, Touchscreen or Keypad Navigation |
| Data Handling | Onboard Storage, Statistical Analysis, Spectrum Visualization, Thermal Printing |
| Brand | TimePower |
|---|---|
| Model | TP340 |
| Origin | Beijing, China |
| Manufacturer | TimePower (Producer) |
| Type | Conductivity-Based Acid-Base Concentration Analyzer |
| Measurement Principle | Conductometric titration / Specific conductivity correlation with concentration |
| Measuring Range | HCl (0–10.00%), NaOH (0–10.00%), H₂SO₄ (0–20.00%), NaCl (0–20.00%), HNO₃ (0–15.00%), Na₂CO₃ (0–10.00%) |
| Accuracy | ±2% F.S. |
| Resolution | 0.01% |
| Repeatability | ≤1% |
| Stability | ±1% F.S./4 h |
| Temperature Compensation | PT1000 sensor, 0–60 °C |
| Sample Temp. | 5–50 °C |
| Ambient Temp. | 5–45 °C |
| Humidity | ≤90% RH (non-condensing) |
| Storage Temp. | −25–55 °C |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤5 W |
| Dimensions | 200 mm × 200 mm × 85 mm |
| Weight | 2.1 kg |
| Display | 5.0″ color TFT touchscreen, Chinese UI |
| A/D Converter | 24-bit |
| Electrode | Corrosion-resistant conductometric cell |
| Brand | Timepower |
|---|---|
| Model | TP340 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Measurement Range (selectable) | HCl (0–10.00%), NaOH (0–10.00%), H₂SO₄ (0–20.00%), NaCl (0–20.00%), HNO₃ (0–15.00%), Na₂CO₃ (0–10.00%) |
| Accuracy | ±2% FS |
| Resolution | 0.01% |
| Repeatability | ≤1% |
| Stability | ±1% FS/4h |
| Temperature Compensation | Pt1000 sensor, 0–60 °C |
| Sample Temp. Range | 5–50 °C |
| Ambient Temp. Range | 5–45 °C |
| Humidity Limit | ≤90% RH (non-condensing) |
| Storage Temp. | −25–55 °C |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤5 W |
| Dimensions | 200 × 200 × 85 mm |
| Weight | 2.1 kg |
| Display | 5.0″ color touchscreen LCD with Chinese UI |
| A/D Conversion | 24-bit |
| Electrode | corrosion-resistant conductometric electrode |
| Brand | TimePower |
|---|---|
| Model | TP 340 |
| Origin | Beijing, China |
| Manufacturer | TimePower Instrument Co., Ltd. |
| Type | Non-contact Inductive Conductivity-Based Concentration Analyzer |
| Measurement Range | HCl (0–10.00%), NaOH (0–10.00%), H₂SO₄ (0–20.00%), NaCl (0–20.00%), HNO₃ (0–15.00%), Na₂CO₃ (0–10.00%) |
| Accuracy | ±2% F.S. |
| Resolution | 0.01% |
| Repeatability | ≤1% |
| Stability | ±1% F.S./4 h |
| Temperature Compensation | Pt1000 sensor, 0–60 °C |
| Sample Temp. | 5–50 °C |
| Ambient Temp. | 5–45 °C |
| Humidity | ≤90% RH (non-condensing) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤5 W |
| Dimensions | 200 × 200 × 85 mm |
| Weight | 2.1 kg |
| Brand | TimePower |
|---|---|
| Model | TP350 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Measurement Principle | Clark-type Membrane Electrode (Galvanic) |
| Display | 128×64 LCD, Chinese Interface |
| Measurement Ranges | 0.0–100 µg/L, 100–1000 µg/L, 1.00–20.00 mg/L (auto-ranging) |
| Resolution | 0.1 µg/L (0–100 µg/L), 1.0 µg/L (100–1000 µg/L), 0.01 mg/L (1.00–20.00 mg/L) |
| Accuracy | ±1.0% FS |
| Repeatability | ≤1% |
| Response Time (T90) | <5 min at 25 °C |
| Temperature Compensation Range | 0–60.0 °C |
| Sample Temperature Range | 5–45 °C |
| Ambient Operating Conditions | 5–45 °C, ≤90% RH (non-condensing) |
| Electrode Type | Galvanic DO sensor with Pt cathode and Pb/Al anode, PTFE/PE hydrophobic membrane |
| Built-in Temp Sensor | Pt1000 |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤1 W |
| Dimensions | 285 × 60 × 255 mm |
| Weight | 2.28 kg |
| IP Rating | IP65 |
| Battery Life | Up to 8 hours continuous operation (internal rechargeable battery) |
| Data Storage | Cyclic memory with >10-year data retention after power loss |
| A/D Converter | 24-bit |
| Circuit Architecture | High-integration SMT design with embedded MCU |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | TP350 |
| Measurement Principle | Clark-type Membrane Electrode (Galvanic or Polarographic, Configurable) |
| Detection Range | 0.0–100 μg/L, 100–1000 μg/L, 1.00–20.00 mg/L (Auto-ranging) |
| Resolution | 0.1 μg/L (≤100 μg/L), 1.0 μg/L (100–1000 μg/L), 0.01 mg/L (1.00–20.00 mg/L) |
| Accuracy | ±1.0% FS |
| Repeatability | ≤1% |
| Response Time (T90) | <5 min at 25 °C |
| Temperature Compensation | Pt1000 sensor, 0–60.0 °C |
| Sample Temp. Range | 5–45 °C |
| Operating Ambient | 5–45 °C, ≤90% RH (non-condensing) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤1 W |
| Display | 128×64 dot-matrix LCD, Chinese interface |
| Data Storage | Cyclic memory with >10-year data retention after power loss |
| Battery Life | Up to 8 hours continuous operation (internal rechargeable battery) |
| Enclosure Rating | IP65 |
| Dimensions | 285 × 60 × 255 mm |
| Weight | 2.28 kg |
| Electrode Configuration | Integrated galvanic DO sensor with PTFE/PE composite membrane, Pt cathode, Pb/Al anode, aqueous electrolyte |
| Brand | TimePower |
|---|---|
| Model | TP350 |
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Measurement Principle | Clark-type Membrane Electrode (Galvanic or Polarographic, Configurable) |
| Detection Range | 0.0–100 µg/L, 100–1000 µg/L, 1.00–20.00 mg/L (Auto-ranging) |
| Resolution | 0.1 µg/L (≤100 µg/L), 1.0 µg/L (100–1000 µg/L), 0.01 mg/L (1.00–20.00 mg/L) |
| Accuracy | ±1.0% FS |
| Repeatability | ≤1% |
| Response Time (T90) | <5 min at 25 °C |
| Temperature Compensation | Pt1000 sensor, 0–60.0 °C |
| Sample Temp. Range | 5–45 °C |
| Operating Ambient | 5–45 °C, ≤90% RH (non-condensing) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤1 W |
| Display | 128 × 64 dot-matrix LCD, Chinese interface |
| Dimensions | 285 × 60 × 255 mm |
| Weight | 2.28 kg |
| IP Rating | IP65 |
| Battery Life | Up to 8 hours continuous operation (rechargeable internal battery) |
| Data Storage | Cyclic memory with >10-year data retention after power loss |
| A/D Conversion | 24-bit high-resolution ADC |
| Circuit Architecture | Surface-mount technology (SMT), integrated modular design |
| Microcontroller | Low-power, high-performance embedded MCU |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Timepower Measurement & Control Co., Ltd. |
| Model | TP526 |
| Test Range | Ambient Temperature to –60 °C |
| Accuracy | ±1 °C |
| Resolution | 0.1 °C |
| Display | LCD |
| Cooling Method | Semiconductor-based Peltier |
| Printer | Thermal, 36-character Chinese/English support |
| Ambient Operating Conditions | 10–40 °C, 30–80% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <300 W |
| Dimensions (W×D×H) | 475 × 360 × 495 mm |
| Weight | 21.3 kg |
| Compliance | Designed per GB/T 510 (Petroleum Products—Determination of Cloud Point) and GB/T 3535 (Petroleum Products—Determination of Pour Point) |
| Brand | Timepower |
|---|---|
| Model | TP526 |
| Origin | Beijing, China |
| Manufacturer | Timepower Measurement & Control Co., Ltd. |
| Test Range | Ambient Temperature to –60 °C |
| Accuracy | ±1 °C |
| Resolution | 0.1 °C |
| Display | LCD |
| Cooling Method | Semiconductor-based Peltier Cooling |
| Printer | Thermal, 36-character Chinese/English alphanumeric output |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <300 W |
| Dimensions (W×D×H) | 475 × 360 × 495 mm |
| Weight | 21.3 kg |
| Operating Environment | 10–40 °C, 30–80% RH |
| Compliance | Designed per GB/T 510, GB/T 3535, ASTM D97, ASTM D2500, ISO 3016, ISO 2084 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Water Content Range | 3 µg – 100 mg |
| Measurement Accuracy | ±0.3% (for samples >1000 µg water) / ±3 µg (for samples 10–1000 µg water) |
| Resolution | 0.1 µg |
| Titration Control Precision | 0.1 µg |
| Minimum Dispensing Increment | 1/1000 |
| Electrolysis Current Range | 0–400 mA |
| Power Supply | AC 220 V ±25 V, 50 Hz ±2.5 Hz |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Display | 128×64 dot-matrix LCD |
| Standby Power Consumption | 4 W |
| Dimensions (W×D×H) | 325×245×180 mm |
| Weight | 4.14 kg |
| Compliance Standards | GB/T 1600, GB 7600, GB/T 6283, GB/T 11133, SH/T 0246, SH/T 0255 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP553 |
| Pricing | Available Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP553 |
| Application | Universal Coulometric Moisture Analyzer for Liquids, Solids, and Gases |
| Measurement Principle | Coulometric Karl Fischer Titration (ASTM D6304, ISO 12937, USP <921>, GB/T 7600, GB/T 6283, SH/T 0246, SH/T 0255) |
| Display | 128×64 Graphic LCD |
| Data Storage | 256 Records with Timestamp (10-Year Non-Volatile Retention) |
| Resolution | 0.1 µg H₂O |
| Measurement Range | 3 µg – 100 mg H₂O |
| Accuracy | ±20% at 3 µg, ±10% at 10 µg, ±5% at 100 µg, ±0.5% above 100 µg (excluding sampling error) |
| Electrolysis Current | 0–400 mA |
| Max. Electrolysis Rate | 2.4 mg H₂O/min |
| Stirring Speed | 10 Adjustable Levels |
| Electrolysis Gain | 10 Adjustable Levels |
| Environmental Operating Conditions | 20–30 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤30 W |
| Dimensions | 320 × 240 × 200 mm |
| Weight | 5 kg |
| Compliance | GLP-ready architecture with audit-trail-capable data logging, RS232 interface for external data export and LIMS integration |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TP553 |
| Titration Method | Coulometric (Karl Fischer) |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 3 µg – 100 mg |
| Accuracy | ≤0.3% (for samples >1 mg) |
| Minimum Sample Injection Volume | 0.5 µL |
| Titration Control Precision | 0.1 µg |
| Electrolysis Current Range | 0–400 mA |
| Max. Electrolysis Rate | 2.4 mg/min |
| Operating Temperature | 20–30 °C |
| Relative Humidity Limit | ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤30 W |
| Dimensions | 320 × 240 × 200 mm |
| Weight | 5 kg |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower Measurement & Control Co., Ltd. |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Measurement Resolution | 0.1 µg H₂O |
| Moisture Range | 1 ppm to 100% w/w |
| Accuracy | ≤0.3% (relative) |
| Minimum Dispensing Increment | 1/2000 of burette volume |
| Titration Precision | ±20% for 3 µg H₂O |
| Compliance Standards | GB/T 7600, GB/T 6283, SH/T 0246, SH/T 0255 |