Chemical Analysis Instruments
Filter
Showing 9601–9630 of 10582 results
| Brand | TE/Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | Xprep C-IC |
| Instrument Type | Laboratory |
| Category | Ion Chromatography Sample Prep System |
| Sample Introduction Modes | Liquid direct injection & Quartz boat solid injection |
| Fraction Collector Capacity | 65 positions |
| Compatibility | Universal IC interface (vendor-neutral) |
| Combustion Capability | Solids, liquids, gases, and LPG |
| Reagent Dispensing | Integrated precision metering system |
| Compliance Context | Designed for ASTM D7359, ISO 14912, USP <643>, and EPA Method 1694-compliant workflows |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | TRQ-600 |
| Type | Online Dew Point Meter |
| Principle | Ceramic Capacitive Sensor (Not Semiconductor — Corrected per Technical Specification) |
| Operating Temperature | -20 to +50 °C |
| Accuracy | ±1 °C dp (at +20 to -60 °C) |
| Repeatability | 0.5 °C dp |
| Response Time (T95) | 5 min (dry-to-wet) |
| Measurement Range | -100 to +20 °C dew point |
| Moisture Output Range | 0–3000 ppmv |
| Analog Output | 4–20 mA (2-wire, current loop) |
| Supply Voltage | 12–28 V DC |
| Max Load Resistance | 250 Ω @ 12 V |
| Max Current Consumption | 23 mA |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TRQ-600 |
| Product Type | Online Dew Point Analyzer |
| Measurement Principle | Ceramic Capacitive Sensor (Hygrometric Impedance) |
| Operating Temperature | -20 °C to +50 °C |
| Accuracy | ±1 °C dew point (+20 °C to −60 °C) / ±2 °C dew point (−60 °C to −100 °C) |
| Repeatability | 0.5 °C dew point |
| Response Time (T95) | 5 min (dry-to-wet transition) |
| Dew Point Range | −100 °C to +20 °C |
| Output Signal | 4–20 mA (2-wire, loop-powered) |
| Supply Voltage | 12–28 V DC |
| Max. Load Resistance | 250 Ω @ 12 V / 500 Ω @ 24 V |
| Current Consumption | ≤23 mA |
| Moisture Output Options | dew point (°C), ppmv H₂O (0–3000 ppmv) |
| Sample Compatibility | Oil-tolerant ceramic sensing element with integrated hydrophobic particulate and molecular sieve filtration |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | DT-230A |
| Temperature Range | Ambient to 100 °C |
| Temperature Stability | ±0.1 °C |
| Temperature Accuracy | ±0.5 °C at 50 °C |
| Repeatability | ±0.1 °C |
| Power Supply | 220 V, 50 Hz |
| Heating Chamber Dimensions (L×W×H) | 350 × 50 × 50 mm |
| Display | Dual-line LED with touch-sensitive controls |
| Safety Features | Over-temperature alarm and automatic power cutoff |
| Mounting Flexibility | Vertical or horizontal orientation |
| Viewing Window | Transparent front panel for real-time column observation |
| Lid Mechanism | Magnetic latch closure |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | KDN-103F |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Semi-Automatic |
| Nitrogen Determination Range | 0.1–200 mg N |
| Steam Distillation Rate | 25 mL/min |
| Repeatability (RSD) | ≤0.2% |
| Sample Mass | 0.3–8 g (solid) or 5–30 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 1200 W |
| Dimensions (L×W×H) | 360 × 300 × 700 mm |
| Weight | 27 kg |
| Operating Voltage | 220 V ±10%, 50–60 Hz |
| Alkali Addition Volume per Cycle | 150 mL |
| Condensate Reception Volume | 400 mL |
| Acid/Alkali-Resistant Splash Guard Material | High-Performance Molded Polymer |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | KDN-2008 |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–200 mg N |
| Sample Capacity | 8 samples per run |
| Steam Distillation Rate | 25 mL/min |
| Relative Standard Deviation (RSD) | ≤1% |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 1200 W |
| Dimensions (L×W×H) | 310 × 300 × 690 mm |
| Net Weight | 28 kg |
| Compliance | ASTM D1142, ISO 8968-1, AOAC 981.10, GB/T 6423–2022 |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | KF-4 |
| Titration Method | Fully Automatic Volumetric Titration |
| Principle | Volumetric Karl Fischer Titration |
| Moisture Range | 10 ppm to 100% H₂O |
| Resolution | 0.1 µL (volumetric) |
| Accuracy | ±0.01% (relative) |
| Minimum Dispensing Volume | 0.005 mL |
| Titration Precision | ±0.1% RSD |
| Stirring Control | Multi-stage Adjustable |
| Display | Large LCD with Real-time Process Monitoring |
| Data Storage | Internal Memory + RS-232/USB Output |
| Dimensions (W×D×H) | 260 × 330 × 170 mm |
| Weight | 3.0 kg |
| Power Supply | AC 220 V, 50/60 Hz |
| Compliance | Designed for GLP-compliant environments |
| Brand | Truelab |
|---|---|
| Origin | Beijing, China |
| Model | LC-3020 |
| Instrument Type | High-Pressure Preparative HPLC System |
| Flow Rate Range | 0.01–9.99 mL/min (analytical mode) |
| Flow Accuracy | ±0.14% (1 mL/min, deionized water, RT) |
| Flow Precision | 0.03% RSD (1 mL/min, deionized water, RT) |
| Max Pressure | 0–45 MPa (analytical) |
| Wavelength Range | 190–700 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±1 nm |
| Baseline Noise | 2×10⁻⁵ AU (254 nm, 1 mL/min, methanol) |
| Drift | 1×10⁻⁴ AU/h (254 nm, 1 mL/min, methanol) |
| Detection Limit | 4.7×10⁻⁹ g/mL (naphthalene, 254 nm, 1 mL/min, methanol) |
| Data Acquisition Rate | 5 Hz |
| Gradient Accuracy | ±1% |
| Detector Optical Path | 10 mm (standard), optional 2 mm / 1.25 mm / 0.5 mm flow cells |
| Pump Architecture | Dual-piston serial configuration with electronic pressure pulsation suppression |
| Control Interface | RS-232 and RS-485 |
| Software | Fully remote-controllable chromatography workstation with instrument parameter setting, method development, data acquisition, peak integration, and report generation |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SZC-C |
| Instrument Type | Soxhlet Fat Extractor (not Kjeldahl Nitrogen Determinator — note correction per technical classification) |
| Automation Level | Manual (user-controlled heating, timing, and solvent management) |
| Fat Determination Range | ≥0.5% (crude fat in grains, foods, feeds, oils, and lipid products) |
| Sample Capacity | 6 positions simultaneously |
| Extraction Time | ~3.5 min per cycle (dependent on solvent boiling point and sample matrix) |
| Repeatability | Relative standard deviation ≤3% |
| Parallel Precision | ≤0.3% absolute difference between duplicates |
| Solvent Recovery Rate | ≥80% |
| Recovery Efficiency | ≥99% (under standardized conditions: reflux rate 120 drops/min, coolant inlet temperature ≤30 °C) |
| Heating Range | Ambient to 200 °C (digital PID-controlled) |
| Temperature Accuracy | ±1 °C |
| Heating Method | Fully enclosed aluminum alloy heating plate |
| Sealing Material | PTFE gaskets |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Rated Power | 300 W |
| Dimensions (L×W×H) | 590 × 390 × 625 mm |
| Net Weight | 25 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UV-2800 / UV-2800PC |
| Optical Design | Dual-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.15 nm |
| Stray Light | ≤0.05% T |
| Baseline Flatness | ±0.001 A |
| Baseline Drift | ≤0.0005 A/h |
| Photometric Accuracy | ±0.3% T |
| Photometric Repeatability | ±0.15% T |
| Display | 320 × 240 LCD |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UV-752 |
| Wavelength Range | 200–1000 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±2.0 nm |
| Wavelength Repeatability | ±1.0 nm |
| Stray Light | ≤0.5% T (at 220 nm and 340 nm) |
| Photometric Accuracy | ±0.5% T |
| Photometric Repeatability | ±0.2% T |
| Baseline Drift | ±0.003 A/h |
| Detector | Photodiode Array |
| Optical Design | Dual-Beam |
| Wavelength Resolution | 0.1 nm step |
| Display | 128×64 LCD |
| Dimensions | 456 × 375 × 220 mm |
| Data Interface | USB |
| Software | UV-Solution Workstation |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | TrueX 2020G |
| Form Factor | Handheld / Portable |
| Instrument Type | Conventional EDXRF Spectrometer |
| Application Scope | General-Purpose Elemental Analysis |
| Elemental Range | Al (13) to U (92) |
| Quantitative Detection Range | 1 ppm – 99.99 wt% |
| Energy Resolution | < 140 eV at Mn Kα |
| Repeatability (RSD) | ≤ 0.1% for major elements under standardized conditions |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TS-I |
| Price Range | USD 140–700 (FOB) |
| Instrument Type | TLC Spray Applicator |
| Scanning Method | Linear (N/A for spray applicator) |
| Wavelength Range | Not Applicable (Non-Optical Device) |
| Light Source | Not Applicable |
| Wavelength Accuracy | Not Applicable |
| Wavelength Repeatability | Not Applicable |
| Scan Speed | Not Applicable |
| Air Pressure Range | 10–30 psi |
| Nozzle Orifice Diameter | 0.2 mm |
| Spray Distance | 50 cm |
| Construction Material | Full Stainless Steel |
| Brand | TTI |
|---|---|
| Origin | USA |
| Model | FTE-7000 |
| Wavelengths | 850, 1300, 1310, 1550 nm ±20 nm |
| Dynamic Range | 27/26 dB (MM), 32/30 dB (SM) |
| Event Dead Zone | 2 m |
| Attenuation Dead Zone | 5 m |
| Distance Range | 1–64 km (MM), 1–240 km (SM) |
| Pulse Width | 20–10,000 ns |
| Resolution | 0.25–64 m |
| Distance Uncertainty | ±(0.75 m + 0.005% × distance + sampling resolution) |
| Sampling Rate | 4 Hz typical real-time refresh |
| Refractive Index Range | 1.024–2.048 |
| Linearity | ±0.05 dB/dB |
| Onboard Storage | 1,000 traces |
| Battery Life | 4 hours |
| Operating Temperature | −10 to 50 °C |
| Storage Temperature | −20 to 60 °C |
| Dimensions (L×W×H) | 194 × 99 × 40 mm |
| Weight | 0.73 kg |
| Interface | USB |
| Connector Types | Interchangeable FC/ST/SC |
| Included Software | Windows-based Telcordia SR-4731 compliant OTDR analysis suite |
| Brand | TTI |
|---|---|
| Origin | USA |
| Model | FTE-8000 |
| Wavelength Range | FTE-8000S: 1492–1528 nm (200.9–196.2 THz) |
| FTE-8000C | 1530–1561 nm (196.0–192.0 THz) |
| FTE-8000L | 1572–1608 nm (190.5–186.3 THz) |
| FTE-8000CWDM | 1271–1611 nm |
| Wavelength Accuracy | ±0.1 nm |
| Channel Spacing | 50 GHz, 100 GHz, or 20 nm (CWDM) |
| Power Range | +10 dBm to –50 dBm |
| Absolute Power Accuracy | ±1 dB |
| Resolution | 0.01 dB |
| Polarization-Dependent Loss (PDL) | ±0.15 dB |
| Optical Attenuation Ratio | 40 dBc (@50 GHz) |
| Sweep Time | <0.5 s |
| Return Loss | >40 dB |
| Optical Connector | Universal UPC (FC/SC compatible) |
| Display | 4-inch TFT color LCD |
| Dimensions | 19.7 × 11.45 × 5.6 cm |
| Weight | 0.91 kg |
| Battery | Rechargeable NiMH, 8-hour runtime |
| Operating Temperature | –10 °C to +50 °C |
| Storage Capacity | 1000 test records |
| Interface | USB host/device (for PC and USB flash drive) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TU-1810 |
| Quotation | Upon Request |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm (auto-calibrated at startup) |
| Wavelength Repeatability | 0.2 nm |
| Spectral Bandwidth | Fixed 2 nm |
| Stray Light | <0.3%T (220 nm, NaI |
| Photometric Modes | Transmittance (%T), Absorbance (Abs), Energy |
| Photometric Range | −0.3 to 3.0 Abs |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs) |
| Photometric Repeatability | 0.001 Abs (0–0.5 Abs) |
| Baseline Flatness | ±0.002 Abs (190–1100 nm) |
| Baseline Drift | 0.001 Abs/h (500 nm, 0 Abs, after 2 h warm-up) |
| Photometric Noise | ±0.001 Abs (500 nm, 0 Abs, 2 nm SBW) |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic (China) |
| Model | W Foil |
| Price Range | USD 0.15 – 1,500 (FOB) |
| Thickness | 0.01–1 mm (customizable) |
| Packaging | Vacuum-sealed in Class 100 cleanroom bags, stored and shipped from Class 1000 cleanroom environment |
| Brand | Tuohé |
|---|---|
| Origin | Shanghai, China |
| Model | SPX-100 |
| Temperature Control | Heating-only (no refrigeration) |
| Temperature Range | Ambient to 99.9°C |
| Temperature Stability | ±0.1°C |
| Repeatability | ±0.1°C |
| Chamber Dimensions | 80 × 40 × 400 mm |
| External Dimensions | 110 × 120 × 480 mm |
| Power Supply | AC 220 V, 50 Hz |
| Weight | 4 kg |
| Display | LCD 12864 with blue backlight and white characters |
| Brand | TuoPu (TP) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Spectral Range | 7800–375 cm⁻¹ |
| Spectral Resolution | 1.0 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 15,000:1 |
| Brand | Wooking |
|---|---|
| Model | 2D-HPLC |
| Type | Multidimensional Liquid Chromatograph |
| Origin | Shandong, China |
| Supplier Type | Authorized Distributor |
| Regional Classification | Domestically Manufactured Instrument |
| Pricing | Available Upon Request |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | U-12C |
| Mounting Compatibility | 6 mm diameter support rod (e.g., URC-1 stand) |
| Adjustment Mechanism | Coarse X-axis translation (14 mm), pivot-and-tilt fine positioning |
| Dimensions (W×D×H) | 40 × 30 × 42 mm |
| Weight | 47 g |
| Material | Precision-machined stainless steel and brass components |
| Drive Type | Manual mechanical adjustment via knurled knobs and friction-based locking |
| Compliance | Designed for laboratory-grade micro-positioning in electrochemical and electrophysiological setups |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | U-31CF |
| Gross Movement Range (X/Y/Z) | 9 mm / 14 mm / 14 mm |
| Fine Adjustment Range (X/Y/Z) | 5 mm / 500 µm / 500 µm |
| Rotation | Full 360° via knurled knob |
| Mounting | Compatible with 6 mm diameter support rods (e.g., URC-1 stand) |
| Dimensions (W×D×H) | 73 × 18 × 62 mm |
| Weight | 91 g |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | U-3C |
| Mounting Options | Ø6 mm rod (URC-1) or M3 screw |
| Travel Range (Coarse) | X: 14 mm, Y: 14 mm, Z: 14 mm |
| Dimensions (W×D×H) | 52 × 35 × 64 mm |
| Weight | 74 g |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Z4 |
| Price | USD 1,400 (FOB) |
| Brand | Ulink Optoelectronics |
|---|---|
| Origin | Beijing, China |
| Model | UC-3220 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–9.999 mL/min |
| Pump Configuration | Dual-piston serial design with electronic pressure pulsation suppression |
| Flow Accuracy | <0.4% RSD at 1 mL/min (deionized water, 25°C) |
| Flow Precision | 0.1% RSD at 1 mL/min (deionized water, 25°C) |
| Maximum Pressure | 40 MPa at 1 mL/min (deionized water, 25°C) |
| Pressure Pulsation | <0.05 MPa at 1 mL/min (deionized water, 25°C) |
| Gradient Accuracy | ±1% (optional binary low-pressure gradient module) |
| Wavelength Range | 190–740 nm |
| Light Source | Deuterium lamp |
| Wavelength Accuracy | ±1 nm |
| Spectral Scanning Mode | Stop-flow automatic scan |
| Baseline Noise | 2×10⁻⁵ AU at 240 nm (25°C) |
| Baseline Drift | 15×10⁻⁵ AU/h at 240 nm (25°C) |
| LOD | 5×10⁻⁹ g/mL (naphthalene standard, methanol mobile phase, 254 nm, 25°C) |
| Control Interface | RS-232 for full bidirectional computer control |
| Display | 2×16-character LCD (English) |
| Power Supply | 220 V AC, 3 A, 200 W |
| Dimensions (L×H×D) | 306×210×420 mm |
| Weight | 12 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | UC-3220A |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Pump Configuration | Dual-piston serial design with electronic pressure pulsation suppression |
| Flow Accuracy | <0.4% RSD (1 mL/min, deionized water, 25 °C) |
| Flow Precision | 0.1% RSD (1 mL/min, deionized water, 25 °C) |
| Maximum Pressure | 40 MPa (1 mL/min, deionized water, 25 °C) |
| Pressure Pulsation | <0.05 MPa (1 mL/min, deionized water, 25 °C) |
| Gradient Accuracy | ±1% |
| Autosampler | XYZ robotic arm configuration (standard) |
| Sample Capacity | 120 × 1.8 mL vials |
| Sample Tray Temperature Control | 4–40 °C |
| Injection Precision | 0.5% RSD (254 nm, 20 µL naphthalene standard in methanol, 1 mL/min) |
| UV-Vis Wavelength Range | 190–740 nm |
| Light Source | Deuterium lamp |
| Wavelength Accuracy | ±1 nm |
| Spectral Scanning Mode | Stop-flow automatic scan |
| Baseline Noise | 2 × 10⁻⁵ AU (254 nm, 25 °C) |
| Baseline Drift | 15 × 10⁻⁵ AU/h (254 nm, 25 °C) |
| LOD | 5 × 10⁻⁹ g/mL (254 nm, naphthalene standard in methanol, 25 °C) |
| Communication Interface | RS-232 for full bidirectional instrument control |
| Display | 4.3-inch TFT color touchscreen |
| Power Supply | 220 V AC, 3 A |
| Dimensions (W × H × D) | 320 × 430 × 430 mm |
| Weight | 25 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | UC-3230A |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Pump Configuration | Dual-piston series design with electronic pressure pulsation suppression |
| Flow Accuracy | <0.4% RSD at 1 mL/min (deionized water, 25°C) |
| Flow Precision | ≤0.1% RSD at 1 mL/min (deionized water, 25°C) |
| Maximum Pressure | 40 MPa at 1 mL/min (deionized water, 25°C) |
| Pressure Pulsation | <0.05 MPa peak-to-peak at 1 mL/min (deionized water, 25°C) |
| Autosampler | XYZ robotic arm configuration (standard) |
| Sample Capacity | 120 × 1.8 mL vials |
| Sample Tray Temperature Control | 4–40°C (Peltier-cooled, optional) |
| Injection Repeatability | ≤0.5% RSD (254 nm, 20 µL naphthalene standard in methanol, 1 mL/min) |
| UV-Vis Detector Wavelength Range | 190–740 nm |
| Light Source | Deuterium lamp |
| Wavelength Accuracy | ±1 nm |
| Spectral Scan Mode | Stop-flow automated scanning |
| Baseline Noise | ≤2 × 10⁻⁵ AU at 254 nm (25°C, 1 s response) |
| Baseline Drift | ≤15 × 10⁻⁵ AU/h at 254 nm (25°C, 1 h) |
| LOD (Naphthalene) | 5 × 10⁻⁹ g/mL at 254 nm (methanol mobile phase, ambient temperature) |
| Communication Interface | RS-232 (full bidirectional instrument control) |
| Display | 4.3-inch TFT true-color touchscreen |
| Power Supply | 220 V AC, 3 A |
| Dimensions (W×H×D) | 390 × 800 × 430 mm |
| Weight | 35 kg |
| Brand | Youlian Optoelectronics |
|---|---|
| Origin | Beijing, China |
| Model | UC-3232 |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Pressure | 42 MPa |
| Wavelength Range | 190–740 nm |
| Data Acquisition Frequency | 10 Hz |
| Flow Accuracy | <0.4% RSD (at 1 mL/min, deionized water, 25°C) |
| Flow Precision | 0.1% RSD (at 1 mL/min, deionized water, 25°C) |
| Pressure Pulsation | <0.05 MPa (at 1 mL/min, deionized water, 25°C) |
| Gradient Accuracy | ±1% |
| Wavelength Accuracy | ±1 nm |
| Baseline Noise | 2×10⁻⁵ AU (240 nm, 25°C) |
| Baseline Drift | 15×10⁻⁵ AU/h (240 nm, 25°C) |
| LOD | 5×10⁻⁹ g/mL (naphthalene, 254 nm, methanol mobile phase, 25°C) |
| Brand | Youlian Optoelectronics |
|---|---|
| Origin | Beijing, China |
| Model | UC-3265 |
| Instrument Type | HPLC Autosampler |
| Sample Capacity | Up to 120 vials (configurable trays) |
| Injection Volume Range | 3–250 µL |
| Precision | RSD < 0.5% (peak area, typical) |
| Carryover | < 0.02% |
| Wash Volume | 0–250 µL (adjustable) |
| Wash Cycles | 1–9 (user-selectable) |
| Syringe Capacity | 250 µL |
| Gradient Accuracy | ±1% |
| Operating Temperature | 10–30 °C |
| Sample Cooling Range | 4–40 °C (±2 °C stability) |
| Display | 4.3-inch TFT LCD touchscreen |
| Controller | 32-bit ARM7 embedded microprocessor |
| Communication | RS-232 / RS-485 |
| Injection Mode | X-Y-Z robotic motion with repeat-injection capability (1–99× per vial) |
| Brand | Youlian Optoelectronics |
|---|---|
| Origin | Beijing, China |
| Model | UC-3268 |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Pricing | Available Upon Request |