| Brand | Abner |
|---|---|
| Origin | Jiangsu, China |
| Model | ABN-SPEC-001 |
| Focal Length | 500 mm |
| Relative Aperture | f/8 |
| Spectral Range (with 600 g/mm grating) | 300–1100 nm |
| Extended Range (with grating exchange) | 150 nm–40 µm |
| Grating Size | 68 mm × 68 mm |
| Max. Installed Gratings | 3 |
| Flat-Field Focal Plane | 30 mm × 12 mm |
| Wavelength Accuracy | ±0.30 nm |
| Wavelength Repeatability | ±0.01 nm |
| Spectral Dispersion (@500 nm) | 1.5 nm/mm |
| Magnification | 1.0 |
| Output Port | Single exit slit |
| Scanning Speed | 150 nm/sec |
| Minimum Step Size | 0.01 nm |
| Interface | High-Speed USB |
| Dimensions (L×W×H) | 530 × 327 × 218 mm |
| Stray Light Level | <1×10⁻⁵ |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR-163 |
| Optical Design | Czerny-Turner |
| Focal Length | 163 mm |
| F/# | f/3.6 |
| Wavelength Range | 300–500 nm |
| Spectral Resolution | 0.08 nm @ 2400 grooves/mm, 300 nm |
| Wavelength Accuracy | ±0.25 nm |
| Wavelength Repeatability | ±0.05 nm |
| Stray Light | ≤0.3% T |
| Dispersion | 2.0 nm/mm (with specified grating) |
| Entrance Slit Options | Multiple fixed and adjustable slit widths |
| Grating Mount | Dual-grating turret (standard), up to 3 gratings optional |
| Detector Compatibility | Full integration with Andor CCD, ICCD, and EMCCD cameras |
| Imaging Plane Dimensions | 28 mm × 10 mm |
| Grating Size | 40 mm × 40 mm |
| Coupling Options | SMA fiber port, kinematic flange, motorized shutter, dynamic slit, silver-coated optics (SR-163-SIL variant) |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR-303i |
| Application Systems | Transmission & Reflectance Spectroscopy |
| Grating Turret | Triple-grating (motorized) |
| Spectral Resolution | 0.08 nm @ 2400 g/mm, 300 nm |
| Dispersion | 2.2 nm/mm |
| Wavelength Range | 303–800 nm |
| F-number | F/4 |
| Wavelength Accuracy | ±0.04 nm |
| Stray Light Rejection | ≤0.3% T (typical), <2.2×10⁻⁵ (peak-to-valley) |
| Focal Length | 303 mm |
| Image Plane Dimensions | 28 mm × 14 mm |
| Slit Width Range | Motorized dynamic slit, up to 12 mm |
| Weight | 20 kg |
| Dimensions (L×W×H) | 394 × 238 × 208 mm |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR-500i |
| Spectral Resolution | 0.05 nm |
| Wavelength Range | 180 nm – IR |
| Dispersion | 1.44 nm/mm |
| F/# | f/6.5 |
| Wavelength Accuracy | ±0.04 nm |
| Stray Light | 2.6 × 10⁻⁵ |
| Grating Configuration | Triple-grating turret |
| Focal Length | 500 mm |
| Entrance/Exit Ports | Up to 2 input and 2 output ports |
| Image Plane Dimensions | 28 mm × 14 mm |
| Physical Dimensions | 550 mm × 343 mm × 206.5 mm |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR-750 |
| Focal Length | 500 mm |
| F/# | F/9.7 |
| Wavelength Range | 300–500 nm |
| Spectral Resolution | 0.02 nm @ 2400 grooves/mm, 300 nm |
| Wavelength Accuracy | ±0.03 nm |
| Wavelength Repeatability | ±10 pm |
| Stray Light Suppression | ≤2.6×10⁻⁵ |
| Grating Size | 68 mm × 68 mm |
| Dispersion | 2.6 nm/mm (at 300 nm, 2400 g/mm) |
| Slit Input Options | 1 or 2 |
| Detector Output Ports | 1 or 2 CCD ports + optional slit output |
| 焦平面尺寸 | 28 mm × 14 mm |
| Grating Turret | 3-position, fully documented per unit |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR193i |
| Spectral Range | 200–1100 nm |
| F/# | 3.6 |
| Spectral Resolution | 0.21 nm @ 1200 g/mm, 500 nm |
| Dispersion | 2.6 nm/mm |
| Wavelength Accuracy | ±0.2 nm |
| Stray Light | 1.5 × 10⁻⁴ |
| Grating Configuration | Dual-grating turret with RFID-enabled auto-identification |
| Optical Design | Imaging-corrected with toroidal mirrors |
| Detector Interfaces | Dual-output ports for simultaneous UV–NIR CCD/EMCCD/ICCD and InGaAs array or single-point detectors |
| Optional Coating | Silver-coated optics for enhanced NIR/SWIR throughput |
| Interface | USB 2.0, plug-and-play |
| Software Integration | Micro-Manager SDK-compatible spectral acquisition and analysis suite |
| Brand | Andor |
|---|---|
| Origin | Israel |
| Model | SR193i |
| Application Systems | Transmission & Reflection Spectroscopy |
| Grating Configuration | Dual-grating turret |
| Spectral Resolution | 0.21 nm @ 1200 g/mm, 500 nm |
| Dispersion | 2.6 nm/mm |
| Wavelength Range | 200–1100 nm |
| F/# | 3.6 |
| Wavelength Accuracy | ±0.2 nm |
| Stray Light | 1.5 × 10⁻⁴ |
| Focal Length | 193 mm |
| Imaging Optics | Aplanatic toroidal mirrors |
| Spectral Reproducibility | ±75 pm |
| Grating Turret | RFID-enabled, quick-release dual-grating turret |
| Detector Compatibility | Dual-output port for simultaneous CCD/EMCCD or sCMOS detector coupling |
| Slit Output Option | Configurable monochromator mode |
| Microscope Integration | C-mount and SM1-threaded interfaces compliant |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR303i |
| Spectral Range | 303–800 nm |
| F/# | F/4 |
| Wavelength Accuracy | ±0.04 nm |
| Wavelength Repeatability | ±0.004 nm |
| Spectral Resolution | 0.08 nm @ 2400 grooves/mm, 300 nm |
| Dispersion | 2.2 nm/mm |
| Stray Light Suppression | ≤2.2×10⁻⁵ |
| Grating Configuration | Triple-grating turret |
| Input/Output Ports | Configurable (1 or 2 CCD outputs, motorized slit) |
| 焦平面尺寸 | 28 mm × 14 mm |
| Grating Size | 68 mm × 68 mm |
| Slit Width | Dynamic, up to 12 mm |
| Brand | Gangdong |
|---|---|
| Origin | Tianjin, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | WGD-8 / WGD-8A |
| Application System | Emission Spectroscopy |
| Grating Configuration | Dual-grating turret |
| Spectral Resolution | ≤0.1 nm (WGD-8), ≤0.06 nm (WGD-8A) |
| Wavelength Range | 200–800 nm (PMT) |
| F-number | F/4 |
| Wavelength Accuracy | ±0.4 nm (WGD-8), ±0.2 nm (WGD-8A) |
| Wavelength Repeatability | 0.2 nm (WGD-8), 0.1 nm (WGD-8A) |
| Stray Light | ≤10⁻³ |
| Slit Width Adjustment | 0–2 mm, 0.01 mm resolution |
| Focal Length | 500 mm |
| Relative Aperture | D/F = 1/7 |
| Dimensions | 560 × 380 × 230 mm |
| Weight | 30 kg |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | C14384MA-01 |
| Application System | Universal |
| Grating Configuration | Integrated Grating Stage |
| Spectral Resolution (FWHM) | 17 nm typ. / 20 nm max. |
| Wavelength Range | 640–1050 nm |
| Wavelength Accuracy | 20 nm typ. / 25 nm max. (640–800 nm) |
| Stray Light | −23 dB |
| Detector | High-Sensitivity CMOS Linear Image Sensor with Integrated Slit |
| Pixel Count | 256 pixels (including optical black) |
| Operating Temperature | Typical at Ta = 25 °C |
| Cooling | Non-cooled |
| Dimensions (L×W×H, excluding flex cable) | 11.7 × 4.0 × 3.1 mm |
| Mass | 0.3 g |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PMA-50 Series |
| Pricing | Available Upon Request |
| Wavelength Range (BT-CCD) | 200–1100 nm |
| Detector Channels (BT-CCD) | 1024 ch |
| Wavelength Range (InGaAs System 1) | 900–1700 nm |
| Detector Channels (InGaAs System 1) | 512 ch |
| Wavelength Range (InGaAs System 2) | 1200–2600 nm |
| Detector Channels (InGaAs System 2) | 256 ch |
| Optical Design | Czerny-Turner |
| Focal Length | 250 mm |
| f-number | f/4 |
| Linear Dispersion | 2.5 nm/mm (at 1200 gr/mm) |
| Grating Capacity | Up to 3 interchangeable gratings (50–1200 gr/mm) |
| Spectral Bandwidth | 61–737 nm (BT-CCD), 46–384 nm (InGaAs) |
| Spectral Resolution | 0.21–2.5 nm (BT-CCD), 0.23–2.0 nm (InGaAs System 1), 0.36–3.0 nm (InGaAs System 2) |
| Detector Cooling | −15 °C (BT-CCD), −10 °C (InGaAs Sys 1), −20 °C (InGaAs Sys 2) |
| Read Noise | 10 e⁻ (BT-CCD), 12,500 e⁻ (InGaAs) |
| Dark Current | 75 e⁻/scan (BT-CCD, −15 °C, 20 ms), 6750 e⁻/scan (InGaAs Sys 1, −10 °C, 5 ms), 6.25×10⁶ e⁻/scan (InGaAs Sys 2, −20 °C, 5 ms) |
| Integration Time | 5 ms – 64 s |
| A/D Resolution | 16 bit |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FHR1000 |
| Application System | Universal |
| Grating Mount | Dual-Grating Turret |
| Spectral Resolution | 0.010 nm |
| Dispersion | 0.8 nm/mm |
| F-number | f/9.0 |
| Focal Length | 1000 mm |
| Wavelength Accuracy | ±0.05 nm |
| Wavelength Repeatability | ±0.015 nm |
| Maximum Scanning Speed | >300 nm/s |
| Grating Dimensions | Single grating: 110 mm × 110 mm |
| Dual-grating configuration | 80 mm × 110 mm each |
| Stray Light | <1×10⁻⁶ (typical, per ISO 14785) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | FHR640 / FHR1000 |
| Focal Length | 640 mm (FHR640) / 1000 mm (FHR1000) |
| f-number | f/5.4 (FHR640) / f/9.0 (FHR1000) |
| Spectral Resolution | 0.016 nm (FHR640) / 0.010 nm (FHR1000) |
| Spectral Dispersion | 1.2 nm/mm (FHR640) / 0.8 nm/mm (FHR1000) |
| Grating Size | 110 × 110 mm (single) / 80 × 110 mm (dual) |
| Wavelength Accuracy | ±0.05 nm |
| Wavelength Repeatability | ±0.015 nm |
| Scan Speed | >300 nm/s |
| Optical Design | Monolithic cast aluminum body with in-axis grating scanning mechanism |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | FHR640/FHR1000 |
| Focal Length | 640 mm (FHR640) / 1000 mm (FHR1000) |
| f-number | f/5.4 (FHR640) / f/9.0 (FHR1000) |
| Spectral Resolution | 0.016 nm (FHR640) / 0.010 nm (FHR1000) |
| Linear Dispersion | 1.2 nm/mm (FHR640) / 0.8 nm/mm (FHR1000) |
| Wavelength Accuracy | ±0.05 nm |
| Wavelength Repeatability | ±0.015 nm |
| Scanning Speed | >300 nm/s |
| Grating Mount | Dual-grating turret (up to two 110×110 mm or 80×110 mm gratings) |
| Output Ports | Dual simultaneous exit ports |
| Structural Design | Monolithic aluminum cast housing |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | H1034 (Dual-Stage) |
| Grating Configuration | Dual Grating |
| Spectral Resolution | ≤5 nm (with 100 µm slit) |
| Wavelength Range | 200–1200 nm (optional blaze wavelengths: 250 nm, 350 nm, 500 nm) |
| F/# | F/2.8 |
| Stray Light | < 0.1% (typical) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | H1034 (Single-Stage) |
| Grating Mount | Motorized 3-Grating Turret |
| Spectral Resolution | ≤5 nm (with 100 µm slit) |
| Wavelength Range | 200–1200 nm (optional blaze wavelengths: 250 nm, 350 nm, 500 nm) |
| F-number | F/2.8 |
| Stray Light | < 0.1% (typical) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | iHR320 / iHR550 |
| Application System | Universal |
| Grating Mount | Dual-grating turret (motorized, selectable) |
| Spectral Resolution | 0.06 nm (iHR320), 0.025 nm (iHR550) |
| Linear Dispersion | 2.31 nm/mm (iHR320), 1.34 nm/mm (iHR550) |
| Wavelength Range | 150 nm – 40 µm |
| F-number | f/4.1 (iHR320), f/6.4 (iHR550) |
| Wavelength Accuracy | ±0.20 nm |
| Stray Light | 1.5 × 10⁻⁴ (iHR320), 1.0 × 10⁻⁵ (iHR550) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | iHR320 / iHR550 |
| Focal Length | 320 mm (iHR320), 550 mm (iHR550) |
| f-number | f/4.1 (iHR320), f/6.4 (iHR550) |
| Spectral Resolution | 0.06 nm (iHR320), 0.025 nm (iHR550) |
| Linear Dispersion | 2.31 nm/mm (iHR320), 1.34 nm/mm (iHR550) |
| Grating Size | 68 mm × 68 mm (iHR320), 76 mm × 76 mm (iHR550) |
| Stray Light | 1.5×10⁻⁴ (iHR320), 1.0×10⁻⁵ (iHR550) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | H20-UVL |
| Spectral Range (Vacuum) | 100–400 nm (3–12.4 eV) |
| Spectral Range (Atmospheric) | 190–400 nm (3–6.5 eV) |
| Focal Length | 200 mm |
| f/# | f/4.2 |
| Grating Type | HJY4 aberration-corrected concave grating |
| Groove Density | 1200 gr/mm |
| Deviation Angle | 64° |
| Linear Dispersion at 100 nm | 3.6 nm/mm |
| Minimum Step Size | 0.06 nm |
| Scanning Speed | up to 400 nm/s |
| Wavelength Accuracy | ±0.2 nm (±0.06 nm with software calibration) |
| Repeatability | ±0.06 nm |
| Resolution (10 µm slit, 2 mm height, 121 nm) | <0.5 nm |
| Base Vacuum | ≤1×10⁻⁵ mbar (vacuum pump and gauge not included) |
| Vacuum Flange | DN40 KF (pump), DN25 KF (input/output) |
| Slit Width Range | 10 µm – 2 mm |
| Slit Height Options | 2, 4, or 6 mm |
| Optical Interfaces | Pre- and post-monochromator mirror chambers with toroidal mirrors |
| Sample Chamber | Accommodates up to four Ø25 mm samples |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | iHR320 / iHR550 |
| Application System | Fluorescence Spectroscopy |
| Grating Mount | Dual-grating turret |
| Stray Light | 1.5×10⁻⁴ (iHR320) / 1×10⁻⁵ (iHR550) |
| Focal Length | 320 mm (iHR320), 550 mm (iHR550) |
| f-number | f/4.1 (iHR320), f/6.4 (iHR550) |
| Spectral Resolution | 0.06 nm (iHR320), 0.025 nm (iHR550) |
| Linear Dispersion | 2.31 nm/mm (iHR320), 1.34 nm/mm (iHR550) |
| Grating Size | 68 mm × 68 mm (iHR320), 76 mm × 76 mm (iHR550) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | TGM300 |
| Spectral Range | 10–300 nm (configurable via interchangeable gratings) |
| Focal Length | 320 mm |
| f-number | f/10 |
| Optical Design | Monolithic toroidal grating monochromator with HJY aberration-corrected toroidal gratings |
| Vacuum Compatibility | UHV up to 1×10⁻⁹ mbar |
| Grating Options | Three standard gratings (550 gr/mm: 10–50 nm & 15–150 nm |
| 275 gr/mm | 50–300 nm) |
| Resolution | ≤0.4 nm (at 15 nm, using 550 gr/mm grating) |
| Slit Integration | Motorized or manual micrometer-driven entrance/exit slits |
| Grating Exchange | In-vacuum dual-grating turret |
| Optional Accessories | Pre-mirror chamber (2 toroidal mirrors), post-mirror chamber (2 toroidal mirrors), sample chamber (4× Ø25 mm positions), polarization insertion optics, 4 K cryostat, DN100LF vacuum flange, DN40KF vacuum gauge port |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | VHR640 / VHR1000 |
| Focal Length | 640 mm / 1000 mm |
| Input/Output Ports | Dual entrance & dual exit |
| Grating Mount | Turret with dual gratings |
| Optical Design | Czerny–Turner |
| Wavelength Range | 100 nm – 15 µm (grating-dependent) |
| Spectral Resolution (10 µm slit) | 0.016 nm (VHR640) / 0.010 nm (VHR1000) |
| Wavelength Accuracy | ±0.03 nm |
| Wavelength Repeatability | ±0.015 nm |
| Scanning Speed | >300 nm/s |
| Spectral Dispersion | 1.2 nm/mm (VHR640) / 0.8 nm/mm (VHR1000) |
| Entrance F/# | f/5.4 (VHR640) / f/9.0 (VHR1000) |
| Grating Size (single-grating mode) | 110 mm × 110 mm |
| Grating Size (dual-grating mode) | 80 mm × 110 mm |
| Slit Range | 0–2 mm (micrometer-adjustable) |
| Vacuum Compatibility | <1×10⁻⁵ mbar |
| Vacuum Flanges | DN25 KF (pump & gauge), DN63 LF (slit), DN100 LF (CCD), PC interface (RS232 to USB) |
| Dimensions (L×W×H) | 740×350×350 mm (VHR640) / 1160×430×350 mm (VHR1000) |
| Mass | 65 kg (VHR640) / 70 kg (VHR1000) |
| Optional Accessories | Pre-mirror chamber (two toroidal mirrors), Post-mirror chamber (two toroidal mirrors), Sample chamber (up to four 25 mm Ø samples), Polarizer inserts, 4 K cryostat, Vacuum pump |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | VS7000+ |
| Application System | Fluorescence Spectroscopy |
| Grating Mount | Motorized or Fixed Grating Turret (OEM Configurable) |
| Spectral Resolution | 0.33 nm/pixel (at 75 µm slit, 2048-pixel CCD, UV-VIS configuration) |
| Dispersion | ~1.6 nm/mm (typical, dependent on grating and focal length) |
| Wavelength Range | 200–1050 nm (configurable via grating & filter options) |
| F/# | f/2.8 |
| Wavelength Accuracy | ±0.2 nm (calibrated, traceable to NIST standards) |
| Stray Light | <0.04% (typical), <0.08% (max), measured with 300 µm UV-VIS CCD, 510 nm bandpass filter, 75 µm slit |
| Brand | HORIBA |
|---|---|
| Model | 1000M / 1250M |
| Focal Length | 1000 mm / 1250 mm |
| F-number | f/8 / f/9 |
| Spectral Resolution | 0.008 nm (1000M) / 0.006 nm (1250M) |
| Linear Dispersion | 0.8 nm/mm (1000M) / 0.65 nm/mm (1250M) |
| Grating Size | 110 mm × 110 mm |
| Wavelength Accuracy | ±0.05 nm |
| Wavelength Repeatability | ±0.005 nm |
| Slit Adjustment Range | 0–3 mm (2 µm step resolution) |
| Step Resolution | 0.00025 nm |
| Input/Output Ports | Dual entrance & dual exit with motorized mirror switching |
| Grating Mount | Manual or motorized interchangeable grating turret |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | MicroHR |
| Focal Length | 140 mm |
| f/# | f/3.88 |
| Linear Dispersion | 5.25 nm/mm |
| Grating Format | Dual-position motorized or manual turret (32 mm × 32 mm) |
| Spectral Range | 180 nm – 20 µm (dependent on grating and detector selection) |
| Detector Interface | Compatible with CCD, PMT, and other single-channel detectors |
| Application Modes | Transmission, Reflection, Fluorescence, Laser Spectroscopy, In-situ & Field Deployment |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | PGS/PGM 1000 |
| Application Modes | Transmission/Reflection Spectroscopy |
| Optical Configuration | Aberration-Corrected Plane Grating + Toroidal Mirror |
| Focal Length | 1000 mm |
| F-number | f/48 |
| Vacuum Compatibility | UHV up to 1×10⁻⁹ mbar |
| Wavelength Range | 4–125 nm (10–310 eV) |
| Resolution (typ.) | 0.02–0.3 nm (dependent on grating selection) |
| Grating Options | 550, 1800, 3600 grooves/mm |
| Exit Slit Interface | Adjustable micrometer slits, DN100 CF/ICF152 detector flange |
| Input/Output Flanges | DN63 LF (pump), DN100 CF (UHV pump), DN40 CF (vacuum gauge) |
| Motorized Wavelength Drive | Stepper motor with USB 2.0 interface |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | VS20 |
| Optical Configuration | Czerny–Turner with concave holographic grating |
| Spectral Range | 200–1700 nm |
| Spectral Resolution | 6.5 nm (FWHM, typical) |
| Dispersion | 90 nm/mm |
| F/# | 2.7 |
| Wavelength Accuracy | < ±0.5 nm |
| Stray Light | < 0.25% @ 260 nm |
| Thermal Drift | < 0.03 nm/°C |
| Dimensions | 15 × 22 × 35 mm |
| Detector Compatibility | CMOS, CCD, InGaAs (e.g., Hamamatsu S837X, S390X, S1011X |
| Application Modes | Transmission & Reflection Spectroscopy |
| Compliance | RoHS-compliant optical housing, ISO 9001 manufacturing environment |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | MicOS |
| Pricing | Available Upon Request |
| Spectrometer Models | iHR320 / iHR550 |
| Spectral Range | 190–1600 nm (with multi-detector configuration) |
| Spectral Resolution | ≤0.1 nm (with 1200 g/mm grating & open-electrode CCD) |
| Detector Options | CCD (1024 × 256), InGaAs (512 × 256), Single-Channel PMT |
| Excitation Wavelengths | 325 nm, 405 nm, 488 nm, 532 nm, 633 nm, 785 nm |
| Objective Lenses | 10×, 50×, 100× (standard) |
| Microscope Configurations | Vertical (objective-down) or lateral (side-objective) |
| Sample Stage | Manual or motorized XYZ stage (optional mapping capability) |
| Integrated Imaging | Built-in digital camera for real-time sample visualization |
| Control Software | LabSpec 8 (FDA 21 CFR Part 11 compliant audit trail, GLP/GMP-ready) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | MicroHR |
| Pricing | Available Upon Request |
| Focal Length | 140 mm |
| f-number | f/3.88 |
| Spectral Dispersion | 5.25 nm/mm |
| Grating Dimensions | 32 mm × 32 mm |
| Spectral Range | 180 nm – 20 µm |
| Detector Compatibility | CCD, PMT, and other single-channel detectors |
| Grating Turret | Manual or motorized dual-grating turret |
| Optical Design | Optimized toroidal focusing mirrors |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MicroHR |
| Price | Upon Request |